• 제목/요약/키워드: Passive/Active System

검색결과 755건 처리시간 0.029초

Off-hooked 트레일러 시스템의 궤적 추종 (Path following of the passive off-hooked trailer system)

  • 이재형;박명국;정우진;김문상;송재복
    • 대한기계학회논문집A
    • /
    • 제27권11호
    • /
    • pp.1831-1839
    • /
    • 2003
  • This paper deals with design and control of passive multiple trailer systems fer practical applications. Due to cost and complexity of trailer mechanism, passive systems are preferred to active systems in this research. The control objective is to minimize trajectory tracking errors of passive multiple trailers. Three types of passive trailer systems-direct-hooked, three-point, and off-hooked- are discussed in this paper. Trajectory tracking performance and stability issues under constant velocity motion are carried out for three types. Various simulations and experiments have been also performed for these three types. It is shown that the proposed off-hooked trailer system produces better tracking performance than the other types.

초정밀작업을 위한 제진시스템의 동역학 모델링 연구 (A Study on Dynamic Modeling of the Vibration Isolation System for the Ultra Precision Measurement)

  • 손성완;장성호;백재호;전종균;권영철
    • 한국산학기술학회논문지
    • /
    • 제10권1호
    • /
    • pp.25-31
    • /
    • 2009
  • 공기스프링을 감쇠기로 사용하는 방진대는 넓은 주파수대역에서 우수한 진동 절연성능을 가짐으로 널리 사용되어 왔다. 하지만 공기스프링은 구조적으로 저강성, 저감쇠의 특성을 가지고 있으므로 외란에 의해 쉽게 가진되어 안정성이 떨어지는 문제가 있다. 이에 공기스프링과 같은 수동소자만을 이용한 수동제어 형식의 보완을 위해 능동 및 반능동 방식의 감쇠기가 제안되고 연구되고 있다. 따라서 본 연구에서는 이러한 수동형 제진대의 능동 및 반능동제어를 위한 동역학적 해석에 관하여 연구하였다. 제진대의 제어시스템 구현을 위하여 6 자유도 제진대의 물리적인 특성에 기초한 동역학적 모델을 정립하고 해석 및 실험을 통해 동역학 모델의 적용가능성을 검증하였다.

Developing a smart structure using integrated DDA/ISMP and semi-active variable stiffness device

  • Karami, Kaveh;Nagarajaiah, Satish;Amini, Fereidoun
    • Smart Structures and Systems
    • /
    • 제18권5호
    • /
    • pp.955-982
    • /
    • 2016
  • Recent studies integrating vibration control and structural health monitoring (SHM) use control devices and control algorithms to enable system identification and damage detection. In this study real-time SHM is used to enhance structural vibration control and reduce damage. A newly proposed control algorithm, including integrated real-time SHM and semi-active control strategy, is presented to mitigate both damage and seismic response of the main structure under strong seismic ground motion. The semi-active independently variable stiffness (SAIVS) device is used as semi-active control device in this investigation. The proper stiffness of SAIVS device is obtained using a new developed semi-active control algorithm based on real-time damage tracking of structure by damage detection algorithm based on identified system Markov parameters (DDA/ISMP) method. A three bay five story steel braced frame structure, which is equipped with one SAIVS device at each story, is employed to illustrate the efficiency of the proposed algorithm. The obtained results show that the proposed control algorithm could significantly decrease damage in most parts of the structure. Also, the dynamic response of the structure is effectively reduced by using the proposed control algorithm during four strong earthquakes. In comparison to passive on and off cases, the results demonstrate that the performance of the proposed control algorithm in decreasing both damage and dynamic responses of structure is significantly enhanced than the passive cases. Furthermore, from the energy consumption point of view the maximum and the cumulative control force in the proposed control algorithm is less than the passive-on case, considerably.

공기스프링을 이용한 방진테이블의 능동 제어 (Active Control of Vibration Isolation Table Using Air-spring)

  • 안채헌;임광혁;진경복;임경화
    • 한국소음진동공학회논문집
    • /
    • 제17권7호
    • /
    • pp.565-571
    • /
    • 2007
  • In the process of accurate manufacture and measurement, it is necessarily required to isolate external or internal vibration due to external disturbance and internal actuators. The higher vibration isolation system gets damping around resonance, the better it is generally. This paper analyzes the performance of an existing passive air-spring for vibration isolation table by using experiment and simulation. Optimal design for a passive air spring can be obtained by tuning the size of the orifice. Also design for an active isolation system is carried out by applying PID controller and considering non-linearity of pneumatic characteristics with help of look-up table. We have developed the active vibration isolation table with the better isolation performance.

공기스프링을 이용한 방진 테이블의 능동 제어 (Active Control of Vibration Isolation Table Using Air-spring)

  • 안채헌;임광혁;권혁진;정진훈;배윤화;진경복;임경화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.831-836
    • /
    • 2006
  • In the process of accurate manufacture and measurement, it is necessarily required to isolate external or internal vibration due to external disturbance and internal actuators. The higher vibration isolation system gets damping around resonance, the better it is generally. This paper analyzes the performance of an existing passive air-spring for vibration isolation table by using experiment and simulation. Optimal design for a passive air spring can be obtained by tuning the size of the orifice. Also design for an active isolation system is carried out by applying PID controller and considering non-linearity of pneumatic characteristics with help of look-up table. We have developed the active vibration isolation table with the better isolation performance.

  • PDF

전류 고조파와 불평형 전원 전압 보상을 위한 직렬형 능동전력필터에 관한 연구 (A Study on the Series Active Power Filter for Harmonic Reduction and Unbalanced Source Voltage Compensation)

  • 오재훈;한윤석;김영석;원충연;최세완
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.191-194
    • /
    • 2001
  • In this paper, we propose a series active power filter control method to compensate current harmonics and unbalanced source voltage. The system is composed of series active power filter and shunt passive filer that are tuned 5th and 7th harmonics. In this conventional system, series active power filter complements drawbacks of the shunt passive filter, namely improves harmonic compensation characteristics, and compensates unbalanced source voltage. In the proposed algorithm, compensation voltage for harmonic reduction is calculated by performance function, and compensation voltage for unbalanced source voltage is calculated in based on a synchronous reference frame. So, ultimate compensation voltage is sum of those two compensation voltages. By computer simulation, we verify the excellency of proposed method.

  • PDF

수동어탐의 가능성과 전망 (Passive acoustic fish detection analysis and its feasible aspects)

  • 장지원
    • 수산해양기술연구
    • /
    • 제22권4호
    • /
    • pp.98-103
    • /
    • 1986
  • The passive acoustic system only has generally used in fish detection. But the passive acoustic system has not been tried in fishing since Freytag has proposed a possibilities of the passive detection of fishes in 1963. This paper describes the .feasible aspects of fish detection by listening of the sound they make. The passive acoustic system accompanied the active acoustic system may expand the range of detection and compensate for lack of capabilities each other, but there are some difficulties in noise rejection because the fre9uency range of ship noises covers the whole range vf biological sounds. The attempt to collect useful informations from underwater would be greatly contributed in fisheries.

  • PDF

대형 구조물의 진동제어를 위한 반능동형 댐퍼의 설계 (Design of Semi-Active Tendon for Vibration Control of Large Structures)

  • 김상범;윤정방;구자인
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.282-286
    • /
    • 2000
  • In this paper, magneto-rheological(MR) damper is studied for vibration control of large infra structures under earthquake. Generally, active control devices need a large control force and a high power supply system to reduce the vibration effectively. Large and miss tuned control force may induce the dangerous situation such that the generated large control force acts to amplify the structural vibration. Recently, to overcome the weaknesses of the active control, the semi-active control method is suggested by many researchers. Semi-active control uses the passive control device of which the characteristics can be modified. Control force of the semi-active device is not generated from the actuator with power supply. It is generated as a dynamic reaction force of the device same as in the passive control case, so the control system is inherently stable and robust. Unlike the case of passive control, control force of semi-active control is adjusted depending on the measured response of the structure, so the vibration can be reduced more effectively against various unknown environmental loads. Magneto-rheological(MR) damper is one of the semi-active devices. Dynamic characteristics of the MR material can be changed by applying the magnetic fields. So the control of MR damper needs only small power. Response time of MR to the input voltage is very short, so the high performance control is possible. MR damper has a high force capacity so it is adequate to the vibration control of large infra structure. Because MR damper has a nonlinear property, normal control method used in active control may not be effective. Clipped optimal control, modified bang-bang control etc. have been suggested to MR damper by many researchers. In this study, sliding mode fuzzy control(SMFC) is applied to MR damper. Genetic algorithm is used for the controller tuning. To verify the applicability of MR damper and suggested algorithm, numerical simulation on the aseismic control is carried out. Simulation model is three-story building structure, which was used in the paper of Dyke, et al. The control performance is compared with clipped optimal control. The present results indicate that the SMFC algorithm can reduce the earthquake-induced vibration very effectively.

  • PDF

RF-ID 스마트 카드 시스템의 설계 및 분석 (Design and Analysis of RF Smart Card System)

  • 양경록;진인수;류형선;김양모
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(5)
    • /
    • pp.203-206
    • /
    • 2000
  • Depending upon the existence of the battery, transponder is divided into active and passive transponder. The passive transponder operates without the inner battery and so has no limitation in its operating range and life time. But the power consumption in the smartcard should be low. In this paper, the analysis and design of the passive smartcard system oerated at 125kHz is presented and is confirmed by simulation and experiment.

  • PDF

PERFORMANCE ANALYSIS OF A STATISTICAL MULTIPLEXER WITH THREE-STATE BURSTY SOURCES

  • Choi, Bong-Dae;Jung, Yong-Wook
    • 대한수학회논문집
    • /
    • 제14권2호
    • /
    • pp.405-423
    • /
    • 1999
  • We consider a statistical multiplexer model with finite buffer capacity and finite number of independent identical 3-state bursty voice sources. The burstiness of the sources is modeled by describing both two different active periods (at the rate of one packet perslot) and the passive periods during which no packets are generated. Assuming a mixture of two geometric distributions for active period and a geometric distribution for passive period and geometric distribution for passive period, we derive the recursive algorithm for the probability mass function of the buffer contents (in packets). We also obtain loss probability and the distribution of packet delay. Numerical results show that the system performance deteriorates considerably as the variance of the active period increases. Also, we see that the loss probability of 2-state Markov models is less than that of 3-state Markov models.

  • PDF