• Title/Summary/Keyword: Pass-by 방법

Search Result 512, Processing Time 0.031 seconds

Analysis of Phase Noise in Frequency Synthesizer with DDS Driven PLL Architecture (DDS Driven PLL 구조 주파수 합성기의 위상 잡음 분석)

  • Kwon, Kun-Sup;Lee, Sung-Jae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.11
    • /
    • pp.1272-1280
    • /
    • 2008
  • In this paper, we have proposed a phase noise model of fast frequency hopping synthesizer with DDS Driven PLL architecture. To accurately model the phase noise contribution of noise sources in frequency hopping synthesizer, they were investigated using model of digital divider for PLL, DAC for DDS and Leeson's model for reference oscillator and VCO. Especially it was proposed that the noise component of low pass filter was considered together with the phase noise of VCO. Under assuming linear operation of a phase locked loop, the phase noise transfer functions from noise sources to the output of synthesizer was analyzed by superposition theory. The proposed phase noise prediction model was evaluated and its results were compared with measured data.

Suppression Control of the Drivetrain-Oscillations of an Electric Vehicle Using Taguchi Method (다구찌 방법을 이용한 전기자동차 구동계의 진동 억제 제어)

  • Kim, Ho-Gi
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.5
    • /
    • pp.463-468
    • /
    • 2009
  • Torsional oscillations of the drivetrain in electric vehicles are generated under rapid driving conditions. These lead to an uncomfortable jerking of the vehicle and an increased stress of the mechanical components. To suppress torsional oscillations, the low pass and notch filters between the torque command from the acceleration pedal and electric motor input torque are suggested. The filter parameters are optimized based on Taguchi method with $L_{18}(3^5)$ orthogonal array. The signal to noise (S/N) ratio mainly depends on slew rate of motor input torque, damping ratio and natural frequency of notch filter. With the proposed suppression control scheme, the S/N ratio is shown to be increased by 4.7dB and the torque overshoot of the drive shaft is reduced to 30%.

Performance Degradation for a Data timing error and a Receiver filtering effect on Digital mobile system (디지털 이동통신 시스템에서 데이터 타이밍 오차와 수신 대역 필터에 의한 성능 열화)

  • 김남수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.10
    • /
    • pp.1598-1605
    • /
    • 1993
  • In this paper, the performance degradation caused by the band pass filter and the data sampling timing error which are generally considered ideal for the simplicity was analyzed. The well known intersymbol interference theory can be applicable to calculate only the upper bound of a system performance. Therefore to obtain the average error probability, a method average intersymbol interference was proposed. This method can be applicable to obtain average error probablity with a computer simulation and with a measured value in test lab. easily.

  • PDF

A Study of DEM Generation in the Ganghwado Southern Intertidal Flat Using Waterline Method and InSAR (수륙경계선 방법과 위상간섭기법을 이용한 강화도 남단 갯벌의 DEM 생성 연구)

  • Lee, Yoon-Kyung;Ryu, Joo-Hyung;Hong, Sang-Hoon;Won, Joong-Sun;Yoo, Hong-Rhyong
    • Journal of Wetlands Research
    • /
    • v.8 no.3
    • /
    • pp.29-38
    • /
    • 2006
  • Digital Elevation Model (DEM) of intertidal flat can be widely used not only for scientific fields, coastal management, fisheries, ocean safety, military, but also for understanding natural and artificial topographic changes of the tidal flat. In this study, we generated DEM of the Ganghwado southern intertidal flat, the largest tidal flat in the west coast of the Korean Peninsula, using waterline method and interferometric synthetic aperture radar (InSAR). Constructed DEM which applied waterline method to the Landsat-5 TM and Landsat-7 ETM+ images closely expresses overall topographic relief of tidal flat. We found that the accuracy was determined by the number of waterlines which reflect various tidal conditions. The application of InSAR to the ERS-1/2 and ENVISAT images showed that only ERS-1/2 tandem pairs successfully generated DEM in the part of northern Yeongjongdo, but construction of DEM in the other areas was difficult due to the low coherence caused by a lot of surface remnant waters. In the near future, Kompsat-2 will provide satellite images having multi-spectral and high spatial resolution within a relatively short period at different sea levels. Application of waterline method to these images will help us construct a high precision tidal flat DEM. Also, we should develop DEM generation method using single-pass microwave satellite images.

  • PDF

Adaptive Row Major Order: a Performance Optimization Method of the Transform-space View Join (적응형 행 기준 순서: 변환공간 뷰 조인의 성능 최적화 방법)

  • Lee Min-Jae;Han Wook-Shin;Whang Kyu-Young
    • Journal of KIISE:Databases
    • /
    • v.32 no.4
    • /
    • pp.345-361
    • /
    • 2005
  • A transform-space index indexes objects represented as points in the transform space An advantage of a transform-space index is that optimization of join algorithms using these indexes becomes relatively simple. However, the disadvantage is that these algorithms cannot be applied to original-space indexes such as the R-tree. As a way of overcoming this disadvantages, the authors earlier proposed the transform-space view join algorithm that joins two original- space indexes in the transform space through the notion of the transform-space view. A transform-space view is a virtual transform-space index that allows us to perform join in the transform space using original-space indexes. In a transform-space view join algorithm, the order of accessing disk pages -for which various space filling curves could be used -makes a significant impact on the performance of joins. In this paper, we Propose a new space filling curve called the adaptive row major order (ARM order). The ARM order adaptively controls the order of accessing pages and significantly reduces the one-pass buffer size (the minimum buffer size required for guaranteeing one disk access per page) and the number of disk accesses for a given buffer size. Through analysis and experiments, we verify the excellence of the ARM order when used with the transform-space view join. The transform-space view join with the ARM order always outperforms existing ones in terms of both measures used: the one-pass buffer size and the number of disk accesses for a given buffer size. Compared to other conventional space filling curves used with the transform-space view join, it reduces the one-pass buffer size by up to 21.3 times and the number of disk accesses by up to $74.6\%$. In addition, compared to existing spatial join algorithms that use R-trees in the original space, it reduces the one-pass buffer size by up to 15.7 times and the number of disk accesses by up to $65.3\%$.

Study on Flowmeter Proving Errors of a Small Volume Prover (소형 푸루버의 유량계 검증 오차 연구)

  • 백종승;임기원;최용문
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.1
    • /
    • pp.259-266
    • /
    • 1990
  • Leaks at the piston seal and the by-pass port of a small volume prover have relatively large influence on the proving accuracy in comparison with a conventional ball prover. The pulse interpolator, which is to increase the discrimination, is affected by the characteristic of the flowmeter signal. In this study, a small volume prover of the double cylinder type was designed in order to study the pulse interpolation error as well as the leak error. The basic volume of the prover determined by a water draw method was about 9.68L. Experimental results revealed that interpolation data attained by the repeated piston pass for turbine meters at a fixed flowrate may be treated effectively by applying a statistical method. It was possible to limit the pulse interpolation error less than .+-. 0.02% at the 95% confidence level. However, in the case of the bulk meter, if failed to achieve the required repeatability level because of the pulse characteristics. The basic volume change appeared to be independent of the piston velocity within the .+-. 0.05% of tolerance.

New Variable Step-size LMS Algorithm with Low-Pass Filtering of Instantaneous Gradient Estimate (순시 기울기 벡터의 저주파 필터링을 사용한 새로운 가변 적응 인자 LMS 알고리즘)

  • 박장식;문건락;손경식
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.3
    • /
    • pp.230-237
    • /
    • 2001
  • Adaptive filters are widely used for acoustic echo canceler, adaptive equalizer and adaptive noise canceler. Coefficients of adaptive filters are updated by NLMS algorithm. However, Coefficients are misaligned by ambient noises when they are adapted by NLMS algorithm. In this Paper, a method determined the adaptation constant by low-pass filtered instantaneous gradient vector of LMS algorithm using orthognality principles of optimal filter is proposed. At initial states, instantaneous gradient vector, that is the cross-correlation of input signals and estimation error signals, has large value because input signals are remained in estimation error signals. When an adaptive filter is conversed, the cross-correlation will be close to zero. It isn's affected by ambient noises because ambient noises are uncorrelated with input signals. Determining adaptation constant with the cross-correlation, adaptive filters can be robust to ambient noises and the convergence rate doesn't slower As results of computer simulations, it is shown that the performance of proposed algorithm is betted than that of conventional algorithms.

  • PDF

Design of a Waveguide Band-Pass Filter Using a Modified H-type Resonant Iris (변형된 H-형 공진 아이리스를 이용한 도파관 대역통과 여파기 설계)

  • Park, Kyoung-Je;Choi, Tae-Ho;Lee, Jong-Ig;Kim, Byung-Mun;Cho, Young-Ki
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.347-353
    • /
    • 2018
  • In this paper, we studied a design method for a band-pass waveguide filter with a modified H-type resonant iris (RI) placed in a thin transverse wall of a rectangular waveguide. The horizontal straight gap at the center of a conventional H-shaped iris is modified to a U-shaped one to increase the equivalent capacitance, and the equivalent inductance is improved by changing the vertical two straight slots into C-shaped ones. From some simulation results for the frequency response of the proposed RI, it was observed that the proposed iris was advantageous for reducing its size and having better cutoff, compared to typical H-shaped one. Equivalent inductance, capacitance, and quality factor of the proposed RI were extracted to analyze its performance. A third-order band pass filter using the proposed modified H-shaped iris was designed and, it was observed that the filter operated in the frequency range of 9.18-9.84 GHz with its insertion loss of 0.3 dB and return loss of 14 dB.

Multi-Pole Low Pass Filter Embedded K-Band LTCC Upconverter (다중 폴 저역 통과 여파기가 내장된 K-대역 LTCC 주파수 상향 변환기)

  • Jeong, Jin-Cheol;Yom, In-Bok;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.6
    • /
    • pp.621-629
    • /
    • 2008
  • This paper presents a low temperature co-fire ceramics(LTCC) Upconverter for a Ka-band OBS satellite transponder in order for size reduction which is one of the most important requirement for satellite components. A S-band low-pass filter(LPF), a K-band band-pass filter(BPF), and an upconverting MMIC mixer are embedded in the multi-layer structure of the upconverter. All spurious can be selectively rejected by employing a modified Elliptic low pass filter with a multi-pole structure for the S-band LPF. Also an improved performance of out-of-band rejection can be obtained. At the K-band BPF design a layer coupled configuration is employed. The upconverting mixer is an MMIC diode mixer with a double-balanced configuration. Conversion loss and isolation of the upconverter are 9 dB and 51 dBc, respectively. The size of the LTCC upconverter is only $8{\times}7{\times}0.6mm^3$ which is one-third for the thin-film based upconverter.

Direct Pass-Through based GPU Virtualization for Biologic Applications (바이오 응용을 위한 직접 통로 기반의 GPU 가상화)

  • Choi, Dong Hoon;Jo, Heeseung;Lee, Myungho
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.2 no.2
    • /
    • pp.113-118
    • /
    • 2013
  • The current GPU virtualization techniques incur large overheads when executing application programs mainly due to the fine-grain time-sharing scheduling of the GPU among multiple Virtual Machines (VMs). Besides, the current techniques lack of portability, because they include the APIs for the GPU computations in the VM monitor. In this paper, we propose a low overhead and high performance GPU virtualization approach on a heterogeneous HPC system based on the open-source Xen. Our proposed techniques are tailored to the bio applications. In our virtualization framework, we allow a VM to solely occupy a GPU once the VM is assigned a GPU instead of relying on the time-sharing the GPU. This improves the performance of the applications and the utilization of the GPUs. Our techniques also allow a direct pass-through to the GPU by using the IOMMU virtualization features embedded in the hardware for the high portability. Experimental studies using microbiology genome analysis applications show that our proposed techniques based on the direct pass-through significantly reduce the overheads compared with the previous Domain0 based approaches. Furthermore, our approach closely matches the performance for the applications to the bare machine or rather improves the performance.