• Title/Summary/Keyword: Partition of energy

Search Result 121, Processing Time 0.031 seconds

Energy Partition to Workpiece in Creep feed Grinding (크맆피드연삭에서 공작물로 유입되는 에너지 비율)

  • 홍순익
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.6
    • /
    • pp.42-48
    • /
    • 1998
  • This paper is concerned with the heat flux distribution and energy partition for creep-feed grinding. From measurements of transient grinding temperatures in the workpiece sub-surface using an embedded thermocouple, the overall energy partition to the workpiece was estimated from moving heat source theory for a triangular heat flux distribution as 3.0% for down grinding and 4.5% for up grinding. The higher energy partition for up grinding can be attribute to the need to satisfy thermal compatibility at the grinding zone. The influence of cooling outside the grinding zone can be analytically taken into account by specifying convective heat transfer coefficients on the workpiece surface ha ahead of the heat source (grinding zone) and hb behind the heat source. The smaller energy partition together with slightly lower grinding power favors down grinding over up grinding.

  • PDF

Energy Partition to Workpiece in Creep feed Grinding (크리피드연삭에서 공작물로 유입되는 에너지 비율)

  • 김남경;박호성;홍순익;송지복
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.799-804
    • /
    • 1997
  • This paper is concerned with the heat flux distribution and energy partition for creep-feed grinding. Form measurements of transient grinding temperatures in the workpiece sub-surface using an embeded thermocouple, the overall energy partition to the workpiece was estimated form moving heat source theory for a triangular heat flux distribution as 3.0% for down grinding and 4.5% for up grinding. The higher energy partition for up grinding can be attributed to the need to satisfy thermal compatibility at the grinding zone. The influence of cooling outside the grinding zone can be analytically taken into account by specifying convective heat transfer coefficients on the workpiecs surface h /sab a/ heat source (grinding zone) and h /sab b/ behind the heat source. The smaller energy patition together with slightly lower grinding power favors down grinding over up grinding.

  • PDF

Evaluation of Cooling Energy Saving through Applying Aisle Partition System on a Data Center Server Room (파티션 시스템 적용을 통한 기존 데이터센터 서버실의 냉방 에너지 절감 성능평가)

  • Park, Jong-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.726-733
    • /
    • 2016
  • In this study, a computer simulation of the three types of air distribution systems, open type system, aisle partition system and aisle containment system, to evaluate the applicability of the aisle partition system on a data center server room. The variables of the simulation were the height and location of the partition fixed on the top server rack. The energy efficiency of the air distribution systems were confirmed to be excellent in the order of the aisle containment system, aisle partition system, and open type system. In the cold aisle partition system, the height of the partition that can be effective in saving cooling energy by obstructing sufficient air recirculation was found to be more than 0.9m. In the hot aisle partition system, the height of the partition was found to be more than 0.8m.

A Computational Study of Natural Convection in Vertical Rectangular Enclosures with Partiton Plates of Finite Thermal Conductivity (유한열전도율(有限熱傳導率)의 격판(隔板)을 갖는 수직구형(垂直矩形) 밀폐공간(密閉空間)에서의 자연대류(自然對流)에 관(關)한 수치적(數値的) 연구(硏究))

  • Park, Man-Heung;Lee, Jae-Heon
    • Solar Energy
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 1982
  • A theoretical study by numerical method has been performed on the natural convection of an air contained in enclosures. The enclosures have rectangular cross section with one vertical wall heated and the other cooled, and with two horizontal partition plates of finite thermal conductivity. Steady two-dimensional flow was assumed. The computation was executed by means of the Implicit Alternating Direction (I.A.D) finite-difference method. Two partition plates of Aluminium whose thickness were 0.05mm was employed in computation. Isothemals, streamlines, local Nusselt numbers and mean Nusselt numbers were obtained for various Grashof numbers and aspect ratio and these results were compared with those in the case of the enclosure with two horizontal insulated plates. From the present results, the heat transfer in the case of partition plates was greater than that in the case of insulation. This study suggests a method to measure the overall heat-transfer of coefficient in double walls which supported by partition plates for insulative construction.

  • PDF

Bayesian analysis of random partition models with Laplace distribution

  • Kyung, Minjung
    • Communications for Statistical Applications and Methods
    • /
    • v.24 no.5
    • /
    • pp.457-480
    • /
    • 2017
  • We develop a random partition procedure based on a Dirichlet process prior with Laplace distribution. Gibbs sampling of a Laplace mixture of linear mixed regressions with a Dirichlet process is implemented as a random partition model when the number of clusters is unknown. Our approach provides simultaneous partitioning and parameter estimation with the computation of classification probabilities, unlike its counterparts. A full Gibbs-sampling algorithm is developed for an efficient Markov chain Monte Carlo posterior computation. The proposed method is illustrated with simulated data and one real data of the energy efficiency of Tsanas and Xifara (Energy and Buildings, 49, 560-567, 2012).

Determination and Temperature Dependence of n-Octanol/Water Partition Coefficients for Seven Sulfonamides from (298.15 to 333.15) K

  • Congliang, Zhang;Yan, Wang;Fuan, Wang
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.7
    • /
    • pp.1183-1186
    • /
    • 2007
  • A shake-flask method was used to determine the n-octanol/water partition coefficients of sulfamethazine, sulfadimethoxine, sulfamethoxydiazine, sulfamonomethoxine, sulfamethoxazole, sulfaquinoxaline and sulfachloropyrazine from (298.15 to 333.15) K. The results showed that the n-octanol/water partition coefficient of each sulfonamide decreased with the increase of temperature. Based on the fluid phase equilibrium theory, the thermodynamic relationship of n-octanol/water partition coefficient depending on the temperature is proposed, and the changes of enthalpy, entropy, and the Gibbs free energy function for sulfonamides partitioning in n-octanol/ water are determined, respectively. Sulfonamides molecules partitioning in n-octanol/water is mainly an enthalpy driving process, during which the order degrees of system increased. The temperature effect coefficient of n-octanol/water partition coefficient is discussed. The results show that its magnitude is the same as that of values in the literature.

A Study on Heat Source Model to High Efficiency Speed Grinding (고능률 고속연삭에서 열원 모델에 관한 연구)

  • 김남경
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.3
    • /
    • pp.1-6
    • /
    • 2001
  • An analytical thermal model of HESG(higt efficiency speed grinding) is presented, in which the heat flux to workpiece in grinding zone is modeled as time dependent and moves along a slope decided by contact chord(approximation of con-tact arc). By matching the maximum surface temperature of workpiece derived from this model to the maximum surface temperature of grinding wheel composite as done in Lavins simple thermal model, the relation of maximum surface tem-perature and energy partition of workpiece to grinding speed is obtained. In high speed grinding, as wheel speed increases, energy partition decreases with no regard to table speed.

  • PDF

A Non-Uniform Network Split Method for Energy Efficiency in a Data Centric Sensor Network (데이타 중심 센서 네트워크에서 에너지 효율성을 고려한 비균등 네트워크 분할 기법)

  • Kang, Hong-Koo;Kim, Joung-Joon;Han, Ki-Joon
    • Journal of Korea Spatial Information System Society
    • /
    • v.9 no.3
    • /
    • pp.35-50
    • /
    • 2007
  • In a data centric sensor network, a sensor node to store data is determined by the measured data value of each sensor node. Therefore, if the same data occur frequently, the energy of the sensor node to store the data is exhausted quickly due to the concentration of loads. And if the sensor network is extended, the communication cost for storing data and processing queries is increased, since the length of the routing path for them is usually in the distance. However, the existing researches that generally focus on the efficient management of data storing can not solve these problems efficiently. In this paper, we propose a NUNS(Non-Uniform Network Split) method that can distribute loads of sensor nodes and decrease the communication cost caused by the sensor network extension. By dividing the sensor network into non-uniform partitions that have the minimum difference in the number of sensor nodes and the splitted area size and storing the data which is occurred in a partition at the sensor nodes within the partition, the NUNS can distribute loads of sensor nodes and decrease the communication cost efficiently. In addition, by dividing each partition into non-uniform zones that have the minimum difference in the splitted area size as many as the number of the sensor nodes in the partition and allocating each of them as the processing area of each sensor node, the NUNS can protect a specific sensor node from the load concentration and decrease the unnecessary routing cost.

  • PDF

A Study on Heat Source Model to Creep Feed Grinding (크?피드 연삭에서 열원 모델에 관한 연구)

  • Jeong, Jong-Dal;Jeong, Hae-Do;Choe, Heon-Jong;Kim, Nam-Gyeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.2
    • /
    • pp.171-176
    • /
    • 2001
  • This study focuses on the energy partition and heat flux distribution in creep-feed grinding. From the measurements of transient grinding temperature in the workpiece which the thermocouple was embedded, the overall energy partition to the workpiece was estimated with moving heat source theory using the developed scalene triangle heat model. The energy partition was calculated as 3.75% in down grinding smaller than 5.3% in up grinding. Also, the scalene triangle heat model was confirmed as the most optional heat model in correspond to the experimental data. Then, the heat flux distribution was calculated from temperature responses. The heat flux is negative behind the grinding zone where fluid was applied. In this experimental result, the total heat flow to the workpiece per unit width obtained by integrating the positive heat flux was 0,7W/mm for down grinding.

  • PDF

Dynamic Island Partition for Distribution System with Renewable Energy to Decrease Customer Interruption Cost

  • Zhu, Junpeng;Gu, Wei;Jiang, Ping;Song, Shan;Liu, Haitao;Liang, Huishi;Wu, Ming
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.6
    • /
    • pp.2146-2156
    • /
    • 2017
  • When a failure occurs in active distribution system, it will be isolated through the action of circuit breakers and sectionalizing switches. As a result, the network might be divided into several connected components, in which distributed generations could supply power for customers. Aimed at decreasing customer interruption cost, this paper proposes a theoretically optimal island partition model for such connected components, and a simplified but more practical model is also derived. The model aims to calculate a dynamic island partition schedule during the failure recovery time period, instead of a static islanding status. Fluctuation and stochastic characteristics of the renewable distributed generations and loads are considered, and the interruption cost functions of the loads are fitted. To solve the optimization model, a heuristic search algorithm based on the hill climbing method is proposed. The effectiveness of the proposed model and algorithm is evaluated by comparing with an existing static island partitioning model and intelligent algorithms, respectively.