• Title/Summary/Keyword: Particulate removal

Search Result 245, Processing Time 0.023 seconds

Serial Particle Size Fractionation and Water Quality in a Recirculating Aquaculture System for Eel

  • Lee, Jin-Hwan
    • Fisheries and Aquatic Sciences
    • /
    • v.13 no.2
    • /
    • pp.133-139
    • /
    • 2010
  • The effects of suspended solids size on culture water quality were determined in a commercial recirculating aquaculture system (RAS) for Japanese eel, Anguilla japonica. The particulate phase of the culture water was serially divided into six size fractions using 300, 200, 100, 75, 45, and 26 ${\mu}m$ pore size stainless sieves. The total, dissolved, and particulate nitrogen and phosphorus, and suspended solids for each fraction were determined. The concentration ranges in the fractions were: total nitrogen, 164-148 mg $L^{-1}$; total phosphorus, 20.4-15.5 mg $L^{-1}$; and total suspended solids, 8.1-6.1 mg $L^{-1}$. The concentration of total nitrogen and total phosphorus decreased significantly (P<0.05) with a 26 ${\mu}m$ and 200 ${\mu}m$ filter pore size, respectively. Nutrients from dissolved organic substances were much higher than from particulates. Analysis of particle size fractionation and its effects on water quality is useful to estimate removal efficiencies of a commercial effluent screening device for solid management and development of solid removal systems.

Efficiency of Removal of Indoor Pollutants by Pistia stratiotes, Eichhornia crassipes and Hydrocotyle umbellata

  • Park, Hye-Min;Lee, Ae-Kyung
    • Journal of People, Plants, and Environment
    • /
    • v.23 no.1
    • /
    • pp.15-21
    • /
    • 2020
  • In this study, we compared efficiency of different aquatic plants in removing indoor pollutants and examined their potential to purify indoor air. Two liter of water in chamber was used as the control, while the other chambers containing water lettuce (Pistia stratiotes), water hyacinth (Eichhornia crassipes), and water coin (Hydrocotyle umbellata) were used as treatment groups. Temperatures inside all the chambers were maintained between 20 ℃ and 23 ℃. Humidity in the chambers with aquatic plants increased by 30% and 50% control respectively. The removal of formaldehyde per unit leaf area was examined in each aquatic plant. It turned out that water hyacinth removed the highest amount of formaldehyde, followed by water lettuce and water coin. Both water hyacinth and water lettuce increased the amount of removal of formaldehyde until the end of the experiment. In the case of airborne dust (PM 10) and fine dust (PM 2.5), water coin, which had the highest number of leaves, removed more PM 10 and PM 2.5 than the other aquatic plants, with statistically significant difference. In addition, both water coin and water hyacinth smoothly opened and closed stomata before and after the experiment. Consequently, as the aquatic plants were effective in controlling humidity and removing pollutants, they can be used as air purifying plants.

Some Factors Affecting on the Redeposition of Particulate Soil (고형오염의 재침착에 영향을 미치는 제인자)

  • Bae Hyun Sook;Kim Sung Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.6 no.2
    • /
    • pp.33-40
    • /
    • 1982
  • The removal and redeposition of particulate soil occur simultaneously during the washing process. In order to investigate variables which affect on the redeposition of particulate soil, cotton lawn was soiled in the ion oxide black suspension using Launder-O meter. The amount of deposited soil was estimated by means of the spectrometric analysis of iron on the fabric after soiled. The results are as follows: 1. The presence of surfactants b suspension decreased the deposition of particulate soil and the most effective surfactant was soap and the descending order was NaDBS>CTAB>PONPE. 2. The influnce of temperature on soil deposition was considerable, soil deposition was gradually increased with elevating temperature in ionic surfactants solution such as NaDBS and CTAB but that was decreased above $40^{\circ}C$ in nonionic surfactant solution. 3. The tendency of soil deposition was dwindled by adding electrolytes especially in case of polyvalent anions. 4. From the results of the experiments redeposition of particulate soil was related with suspending power of surfactants and was influenced by factors varing zeta potential.

  • PDF

The Effect of Particle Size on the Detergency of Particulate Soil (고형오구 입자크기가 고형오구의 세척성에 미치는 영향)

  • Mun, Mi-Hwa;Kang, In-Sook
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.4
    • /
    • pp.653-662
    • /
    • 2010
  • This study investigates the effect of particle size on the detergency of particulate soil using an $\alpha-Fe_2O_3$ particle as the model. Monodispersed spherical $\alpha-Fe_2O_3$ particles were prepared by the hydrothermal aging of an acidic $FeCl_3$ and HCl solution. The $\xi$-potential of PET fiber was measured by the streaming potential method. The potential energy of interaction between the particle and fiber was calculated using the heterocoagulation theory for a sphere-plate model. The $\xi$-potential of PET fiber and potential energy of interaction between particles and fiber increased with a decreasing particle size in a DBS solution. However, in the nonionic surfactant solution, the $\xi$-potential signs of PET fiber and $\alpha-Fe_2O_3$ particles were (-) and (+), respectively; there was no repulsive power between the particles and substrate. The adhesion of particles to the fabric increased with increasing particle size in the anionic surfactant solution and their removal from the fabric increased with a decreasing particle size. The adhesion of particles to the fabric and their removal from the fabric was biphasic with a maximum and minimum at 0.1% concentration of the surfactant solution. In the nonionic surfactant solution the adhesion of particles to fabric and their removal from the fabric were greater than the ones in the anionic surfactant DBS solution.

A feasibility study of a pilot scale two-phase anaerobic digestion with ultra filtration for the treatment of garbage leachate (음식물 탈리액 처리를 위한 파일럿 규모의 막결합형 2상 혐기성 소화 공정 가능성 평가)

  • Lee, Eun-young;Heo, Ahn-hee;Kim, Hyung-kuk;Kim, Hee-jun;Bae, Jae-ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.539-545
    • /
    • 2009
  • A feasibility of a pilot scale two-phase anaerobic digestion with ultra filtration system treating garbage leachate were evaluated. The treatment system consisted of a thermophilic acidogenic reactor, a mesophilic methanogenic reactor, and an UF membrane. The average COD removal efficiency of the treatment system was 95% up to the OLR of 3.1 g COD/L/d. The higher COD removal efficiency with membrane unit resulted from the removal of some portion of soluble organics by membrane as well as particulate materials. When the membrane unit was in operation, bulk liquid in acidogenic and methanogenic reactors was partially interchanged, which maintained the acidogenic reactor pH over 5.0 without external chemical addition. Also, with the production of methane in the acidogenic reactor, the organic loading rate of the methanogenic reactor reduced. The initial flux of the membrane unit was $50{\sim}60L/m^2/hr$, but decreased to $5 L/m^2/hr$ after 95 days of operation due to clogging caused by particulate materials such as fibrous materials in garbage leachate. To prevent clogging caused by particulate materials, a pretreatment system such as screening is required. With the improvement with membrane unit operation, the two-phase anaerobic digestion with ultra filtration system is expected to have the possibility of treating garbage leachate.

Optimization of an Ozone-based Advanced Oxidation Process for the Simultaneous Removal of Particulate Matters and Nitrogen Oxides in a Semiconductor Fabrication Process (반도체 제조공정 미세먼지-질소산화물 동시 저감을 위한 오존 고속산화공정 최적화 연구)

  • Uhm, Sunghyun;Lee, Seung Jun;Ko, Eun Ha;Hong, Gi Hoon;Hwang, Sangyeon
    • Applied Chemistry for Engineering
    • /
    • v.32 no.6
    • /
    • pp.659-663
    • /
    • 2021
  • 10 m3/min (CMM) multi-pollutants abatement system was successfully developed by effectively integrating ozone oxidation, wet scrubbing, and wet electrostatic precipitation for the simultaneous removal of particulate matters (PMs) and NOx in a semiconductor fabrication process. The sophisticated control and optimization of operating parameters were conducted to maximize the destruction and removal efficiency of NOx. In particular, the stability test of a wet electrostatic precipitator was carried out in parallel for 30 days to validate the reliability of core parts including a power supply. An O3/NO ratio, which is the most important operating parameter, was optimized to be about 1.5 and the optimization of wet scrubbing with a reducing agent made it possible to analyze the contribution of neutralization reaction.

Removal Potential of Particulate Matter of 12 Woody Plant Species for Landscape Planting

  • Kwon, Kei-Jung;Urrintuya, Odsuren;Kim, Sang-Yong;Yang, Jong-Cheol;Sung, Jung-Won;Park, Bong-Ju
    • Journal of People, Plants, and Environment
    • /
    • v.23 no.6
    • /
    • pp.647-654
    • /
    • 2020
  • Background and objective: Particulate matter (PM) is one of the serious environmental problems and threatens human health. Plants can clean the air by removing PM from the atmosphere. This study was carried out to investigate the PM removal efficiency of 12 species of woody plants. Methods: Actinidia arguta, Dendropanax morbiferus, Fraxinus rhynchophylla, Parthenocissus tricuspidata, Pittosporum tobira, Rhaphiolepis indica, Rhapis, Salix integra, Salix koreensis, Schisandra chinensis, Viburnum odoratissimum var. awabuki, and Vitis coignetiae were used as plant material. Six 15 cm (D) pots were placed in an acrylic chamber of 800 (D) × 800 (W) × 1000 (H) mm. The LED panel was used as a light source. The reduction of PM10, PM2.5, and PM1 for 300 minutes after the injection of PM was automatically measured. Results: The leaf area and the amount of PM in the chamber showed a negative correlation. 12 species of plants were compared by dividing the plants into 3 groups according to their characteristics: vines, trees, and shrubs and small trees. In the vine plant group, the averages of PM10, PM2.5, and PM1 were 7.917%, 8.796%, and 30.275%, respectively. In the shrubs and small trees group, the average of PM10, PM2.5, and PM1 were 10.142%, 11.133%, and 36.448%, respectively. In the trees group, the average of PM10, PM2.5, and PM1 were 11.475%, 12.892%, and 40.421%, respectively. When the initial concentration was 100%, PM10, PM2.5, and PM1 of Viburnum odoratissimum var. awabuki with the largest leaf area were 5.6%, 6.3%, and 21.0% after 5 hours, respectively, the best results among 12 species of plants. Conclusion: The vine plant group was more effective in removing PM than the other two groups. In the tree groups, the fact that the leaf development was relatively inactive at a plant height of 30 cm was considered to have an effect on the removal of particulate matter.

Experimental Evaluation of Particulate-matter Filtration Performance of a Bottom Ash-Silica Sand Mixture (석탄 저회-규사 필터의 입자상물질 여과 성능 실험적 평가)

  • Lee, Dong-Hyun;Lee, Hong-Kyoung;Lee, Yun-Jae;An, Jaehun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.6
    • /
    • pp.41-47
    • /
    • 2022
  • Permeable pavement technology allows the penetration of rainfall into the roadbed, thereby reducing surface runoff and enhancing water quality. The water quality can be improved by adding a filter layer to the permeable pavement. This study analyzes the permeability performance and particulate-matter removal efficiency of a bottom ash-silica sand filter. The performances of five filters with bottom ash and silica sand as the basic materials were evaluated on particulate matter sized 60 ㎛ or smaller. The pure silica sand sample and pure bottom ash sample delivered an average removal efficiency of around 70%. The removal efficiency of the mixed sample was approximately 90%, exceeding the recommended reduction rate (80%) at non-point pollution reduction facilities. In future work, the filter performance should be further verified on permeable pavement.

A Study on the Fine Dust Removal Equipment of Pressurized Water type for the Removal of Exhaust Gas Fine Dust and Volatile Organic Compounds from the Non-industrial combustion plant (비산업 연소 사업장 배출 가스상 미세먼지와 휘발성 유기 화합물 제거를 위한 가압수식 미세먼지 제거 장치 연구)

  • Youn, Jae-Seo;Kim, Sang-Min;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.11
    • /
    • pp.506-512
    • /
    • 2018
  • The fine dust generated in the home and restaurant business occupies a low ratio of about 4% of the total fine dust emissions. However, at the foodservice business, the rate of change of the pollutant concentration is very high, so that the temporary fine dust concentration can be measured up to 60 times. The pollutants generated from non-industrial combustion plants consist of particulate fine dust and gaseous organic compounds. To remove these pollutants, cleaning dust collection system, which is an effective system for simultaneous removal of gaseous and particulate matter, is applied. This is a method of increasing the probability of diffusion capture of the Brownian motion by pressurized liquid injection method using the atomizing nozzle. The dust removal efficiency of the fine dust collecting system was analyzed by nozzle spraying air pressure condition and angle using the manufactured fine dust removing system. As a result, it was confirmed that the efficiency of removal of fine dust and gaseous organic compounds was more than 90%. The developed system is expected to be highly usable in the future because it can remove particulate dust from the existing plant hood system without any installation cost.

Application of Cyclone to Removal of Hot Particulate in Hot Cell (Hot Cell 내의 고방사능 분진 제거를 위한 사이클론 적용 실험)

  • Kim Gye Nam;Lee Sung Yeol;Won Hui Jun;Jung Chong Hun;Oh Won Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.67-75
    • /
    • 2005
  • The size and main ingredient of hot particulate generated during the nuclide experiment in hot cells of nuclear facilities were 0.5300 $\mu$m and UO$\_2$. A cyclone filter equipment which consists of a cyclone and Bag/HEPA filter was devised to remove hot particulate generated during the nuclide experiment in hot cells of nuclear facilities. The experimental conditions to maximize the collection efficiency of hot particulate were suggested through experiments done with the cyclone filter equipment. With the large size of simulated particulate, the collection efficiency of the particulate was high. When the size of simulated particulate was more than 5 $\mu$m, the collection efficiency of the particulate was more than $80\%$ and when the size of simulated particulate was less than 1.0 urn, the collection efficiency decreased by less than $70\%$. If the inflow velocity of simulated particulate was increased, the collection efficiency of the particulate was also increased. When the inflow velocity of simulated particulate was more than 12m/sec, the collection efficiency was higher than $70\%$, but after 17 m/sec inflow velocity, no change observed. The collection efficiency of the simulated particulate can be enhanced with the length of vortex finder inside the chamber. With the length of vortex finder, 7.2cm, the observed collection efficiency of the particulate was the maximum. Moreover, when the sub-cone was attached under the cyclone, the collection efficiency of cyclone increased $2\%$. It was found that effect by attachment of sub-cone was not serious.

  • PDF