• Title/Summary/Keyword: Particulate filtration

Search Result 110, Processing Time 0.035 seconds

ENHANCED REMOVAL OF RESIDUAL ALUMINUM AND TURBIDITY IN TREATED WATER USING POLYMERS

  • Kim, Seung-Hyun
    • Environmental Engineering Research
    • /
    • v.10 no.4
    • /
    • pp.155-164
    • /
    • 2005
  • This study investigated the possibility of reducing the residual aluminum (Al) in the treated water using polymers. Two raw waters (lake and river water) and three kinds of polymers (coagulant, flocculant, and filtration aids) were used for this purpose. This study found that coagulation at the high dose did not necessarily lead to the high concentration of the residual Al in the treated water. The coagulation efficacy was found more important in determining the residual Al than the coagulant dose. The use of a polymer enhanced the removal of turbidity as well as the residual Al. The coagulant aid removed the dissolved Al as well as the particulate Al by helping the coagulation and the solid-liquid separation. The flocculant aid and the filtration aid preferentially removed the particulate Al while helping the solid-liquid separation. The filtration aid reduced the residual Al substantially more effectively than the flocculant aid. The polyamine-based coagulant aid (FL) showed the better performance in reducing the residual Al and turbidity than DADMAC (WT). The cationic flocculant aid with weak charge density and the medium molecular weight (SC-020) showed the best performance in reducing the residual Al.

An Experimental Study on the Smoke Filtration System Using Water Injection and Vacuum Pump driven by Exhaust Gas (물 분사 및 배기가스 구동형 진공펌프를 이용한 매연여과장치에 대한 실험적 연구)

  • Lee, Han-Sung;Kim, Kyong-Hyon;Jung, Suk-Ho;Koh, Dae-Kwon
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.17-22
    • /
    • 2013
  • Diesel particulate filter has been adopted in new vehicle with diesel engine. Since the flow of exhaust gas was clogged as particulate matters were deposited in the filter, it have bad effects on a fuel consumption and power. It was investigated that a particulate filtering system with vacuum pump in the exhaust gas line could be free from clogging in previous research. In this study, the effects of water injection and position of inlet port in filtering system on reducing in particulate matter were investigated. It was noticed that particulate matter were decreased remarkable by water injection and moving the position of inlet port.

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

Experimental determination of design parameters for filtration trench using phosphorus removal granular materials (인 제거 입상소재를 적용한 여과수로 설계인자의 실험적 결정)

  • Jang, Yeoju;Lim, Hyunman;Jung, Jinhong;Ahn, Kwangho;Chang, Hyangyoun;Park, Nari;Kim, Weonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.9-16
    • /
    • 2019
  • The algal blooms in stagnant streams and lakes have caused many problems. Excessive algae leads to disturbance of ecosystem and overload of water treatment processes. Therefore, phosphorus(P), source of algal blooms, should be controlled. In this study, a filtration trench has been developed to convert dissolved phosphorus into hydroxyapatite(HAP) so that it could be crystallized on the surface of 'phosphorus removal granular material'; and residual particulate phosphorus could be removed by additional precipitation and filtration. The front and rear parts of filtration trench consisted of 'phosphorus removal granular material contact bed' and 'limestone filtration bed', respectively. As a result of the column test using phosphorus removal granular material and limestone serially, $PO_4-P$ was removed more than 90% when EBCT(empty bed contact time) of the contact bed was over 20 minutes; and T-P represented 60% of removal efficiency when total EBCT was over 1.5 hours. The results of column tests to figure out the sedimentation characteristics showed that more than 90% of particulate phosphorus could be removed within 24 hours. It was necessary to optimize the filtration part in order to increase removal efficiency of T-P additionally. Also, it was confirmed through the simulation of Visual MINTEQ that most of particulate phosphorus in the column tests is the form of HAP. Based on the results of the study, it could be suggested that the design parameters are over 0.5 hour of EBCT for phosphorus removal granular material contact bed and over 1.5 hours of EBCT for limestone filtration bed.

A Detailed Examination of Various Porous Media Flow Models for Collection Efficiency and Pressure Drop of Diesel Particulate Filter (DPF의 PM 포집효율 예측을 위한 다양한 다공성 매질 유동장 모델 해석)

  • Jung, Seung-Chai;Yoon, Woong-Sup
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.78-88
    • /
    • 2007
  • In the present study a detailed examination of various porous media models for predicting filtration efficiency and pressure drop of diesel particulate filter (DPF), such as sphere-in-cell and constricted tube models, are attempted. In order for demonstrating their validities of correct estimation on permeability, geometry of property configurations common in commercial cordierite DPFs are correlated to the porous media flow models, and validations of predicted filtration efficiencies due to the use of different unit collectors are made with experiments. The result shows that the porosity, pore size and permeability of cordierite DPF can be successfully correlated by Kuwabara flow field with correction factor of 0.6. The unit collector efficiency predicted by sphere-in-cell model agrees very well with measurements in accumulation mode, whereas that by constricted tube model with significant prediction error.

Enhancement of filtration efficacy for particulate matters using β-glucan coated commercial masks

  • Muthuramalingam, Karthika;Kim, Young Mee;Cho, Moonjae
    • Journal of Applied Biological Chemistry
    • /
    • v.64 no.1
    • /
    • pp.1-4
    • /
    • 2021
  • Ambient air pollution, in particular, particulate matter (PM) pollution imposes serious health concerns such as hospitalization and premature deaths, worldwide. While commercial breathing masks are in use for protection against this hazardous issue, yet their efficiency in filtering PM was not up to the par, besides several other discomforts such as poor breathability due to reduced air flow, sweat production etc. In this study, commercial face mask coated with β-glucan, a high molecular weight polymer is tested for its efficacy in filtering PM. Quantification of PM before and after filtration and microscopic observation (using scanning electron microscopy (SEM)) of the fabric used in filtering the dust pollutants (generated from wood chips and cigarette) showed that β-glucan coated fabric were significantly efficient in capturing PM (size of 10 and 2.5 ㎛ in diameter) than that of the untreated control fabric, wherein the former had filtration efficacy with fold increase of 11.6 and 2.6 towards capturing PM2.5 and PM10 respectively than the latter. Thus, β-glucan coated fabric was found to be effective in filtering PM.

The Separation of Particulate within PFC Decontamination Wastewater Generated by PFC Decontamination (PFC 제염 후 발생된 제염폐액 내 오염입자의 제거)

  • Kim Gye-Nam;Lee Sung-Yeol;Won Hui-Jun;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho;narayan M.
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.06a
    • /
    • pp.32-39
    • /
    • 2005
  • When PFC(Perfluorocarbonate) decontamination technology is applied to removal of radioactive contaminated particulate adhered at surface during the operation of nuclear research facilities, it is necessary to develop a filtration equipment to reuse of PFC solution due to high price, also to minimize the volume of second wastewater. Contaminated characteristics of hot particulate was investigated and a filtration process was presented to remove suspended radioactive particulate from PFC decontamination wastewater generated on PFC decontamination. The range of size of hot particulate adhered at the surface of research facilities measured by SEM was $0.1{\sim}10{\mu}m$. Hot particulate of more than $2{\mu}m$ in PFC contamination wastewater was removed by first filter and then hot particulate of more than $0.2{\mu}m$ was removed by second filter. Results of filter experiments showed that filtration efficiency of PVDF(Poly vinylidene fluoride), PP(Polypropylene), Ceramic filter was $95{\sim}97\%$. A ceramic filter showed a higher filtration efficiency with a little low permeate volume. Also, a ceramic of inorganic compound could be broken easily on experiment and has a high price but was highly stable at radioactivity in comparison of PVDF and PP of a macromolecule which generate $H_2$ gas in alpha radioactivity environment.

  • PDF

Compressive rheology of aggregated particulate suspensions

  • Gladman Brendan;Usher Shane P.;Scales Peter J.
    • Korea-Australia Rheology Journal
    • /
    • v.18 no.4
    • /
    • pp.191-197
    • /
    • 2006
  • The measurement of the compressional rheological parameters for an aggregated particulate suspension is described. The parameters include the compressive yield stress and hindered settling function, describing the extent and rate of dewatering respectively. The variation of these parameters with shear rate and time of shear is also considered in the light of their sensitivity to low shear rates, with particular reference to the case of flocculated particulate suspensions. The latter is seen to be important in the future development of a comprehensive understanding of compressive rheology of aggregated particulate suspensions in industrial applications such as thickening, filtration and centrifugation.

Study on the Total Analyses of Cake Filtration with Filtration-Permeation Method (여과-투과 방법에 의한 케이크 여과의 전체적인 해석)

  • Yim, Sung-Sam;Song, Yun-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.1
    • /
    • pp.74-81
    • /
    • 2007
  • Using the new experimental method named "filtration-permeation", the average specific resistances which plays an important role in designing cake filtration apparatus and the development of cake filtration theory were measured in this study. By this new experimental method, two kinds of average specific resistances are measured. The one from the filtration is named 'filtration average specific resistance $\alpha_{avf}$, and the other from the permeation of particle eliminated water through the pre-formed cake is named 'permeation average specific resistance $\alpha_{avf}$. The "filtration-permeation" method is applied to three different kind of suspensions(i.e. particulate suspension, pre-flocculated suspension and macro-molecule suspension) to obtain filtration and permeation average specific resistances. A theoretical procedure of cake filtration is studied based on the values of permeation average specific resistance. With the study it was concluded that the influence of the sedimentation during particlulate filtration operation could not be ignored as commonly used. And the solid content of suspension, S, which also regarded usually as constant, changes during filtration of particles. It is also verified that the exact value of solid content of cake for floe filtration could not be obtained. These significant problems are all solved by our new "filtration-permeation" experimental method.

Development and Performance Evaluation of a Filtration Equipment to Reuse PFC Waste Solution Generated on PFC Decontamination (PFC 제염 시 발생된 PFC 폐액의 재사용을 위한 여과장치 개발 및 성능평가)

  • Kim Gye-Nam;Jeong Cheol-Jin;Won Hui-Jun;Choi Wang-Kyu;Jung Chong-Hun;Oh Won-Zin;Park Jin-Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.2
    • /
    • pp.161-170
    • /
    • 2006
  • PFC(Perfluorocarbon) decontamination process is one of best methods to remove hot particulate adhered on the inner surface of hot cell and surface of equipment in hot cell. It was necessary to develop a filtration equipment to reuse the PFC waste solution generated on PFC decontamination due to the high cost of PFC solution and for minimization of the volume of second waste solution. The filtration equipment was developed to remove hot particulate in PFC waste solution. It was made suitable size and weight in consideration of hot cell gate and crane. And it has wheels for easy movement. Flux of the filtration equipment decreased with particulate concentration increase. It consists of pre-filter($1.4{\mu}m$) and final-filter($0.2{\mu}m$) for protection of the flux decrease along filtration time. It treatment capacity of waste solution is 0.2 L/min.

  • PDF