• Title/Summary/Keyword: Particulate filtration

Search Result 111, Processing Time 0.023 seconds

Evaluation on Performance of an Electrostatic Diesel PM Trap Device and Its Application to Diesel Engine After-treatment (정전 방식 디젤 PM 포집 장치 성능 및 엔진 적용성 평가)

  • Kim, Hak-Joon;Han, Bang-Woo;Kim, Yong-Jin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.176-183
    • /
    • 2008
  • Performance of electrostatic diesel PM filtration systems (E-DPS) with different types has been tested using the carbon particles generated by spark discharge in laboratory. Among the five electrostatic precipitators, the multiple wires cylindrical E-DPS with the highest collection efficiency and relatively lower differential pressure at the flow rate of $1\;m^3$/min, as an applicable device to diesel engine as an after treatment system, has been combined with another collection cylinder to improve the collection efficiency of diesel particulate matters generated from diesel engines. The multiple wires cylindrical E-DPS combined with the cylindrical collector showed the collection efficiency of more than 60% at the engine speed of 2,000 rpm with the engine loads of 25 and 50%.

A Study on the Reverse Cleaning Flow Characteristics for High Temperature and High Pressure Filtration (고온 고압 집진을 위한 역세정 유동장의 특성에 관한 연구)

  • 김장우;정진도;김은권
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.1
    • /
    • pp.25-31
    • /
    • 2003
  • Ceramic filter has been demonstrated as an attractive system to improve the thermal efficiency and to reduce the effluent pollutants. Removal of particulates from the hot gas stream is very important in air pollution control. In particular, the elimination of the particulate matters discharged from a gas turbine at high temperature can prevent the corrosion inside the IGCC. In this study, a Lab. scale test and numerical simulation were carried out to comprehend the relationship between pulse jet pressure and recovery of pressure drop and to characterize the reverse cleaning flow through a ceramic fil-ter element under high temperature and high pressure. When the pulse-jet pressures were 2, 3 and 4 kg/$ extrm{cm}^2$, the cleaning effect increase of about 10~30% by recovery of pressure drop caused by pulse pressure. Cleaning effect at 45$0^{\circ}C$ was greater than that at 55$0^{\circ}C$ or 650$^{\circ}$ for the same pulse pressure. According to the result of the present simulation, high pressure has been formed in terminal and central regions in our models and temperature distribution caused by pulse air is to be uniform comparatively on inner surface of filter.

A Study on the Refinement of the Electronic Grade 2-Propanone (전자 등급 2-프로파논의 정제에 관한 연구)

  • Lee, Sang-Won;Kim, Sung-Il;Park, So-Jin
    • Journal of the Korean Applied Science and Technology
    • /
    • v.25 no.4
    • /
    • pp.503-510
    • /
    • 2008
  • This research is related to the process of refining the raw material, industrial 2-propanone to the 2-propanone of the electronic grade. With this view, the high purity of 2-propanone was obtained through the complex preprocessing(physical adsorption method), distillation process and membrane-filtration of distillate. Impurities were identified by GC and UV, and then we assayed the water content in 2-propanone passing adsorption step made of activated carbon and Zeolite 4A. Furthermore, the distillation was performed with the packed column distillation apparatus to eliminate impurities such as acetaldehyde. Particulates were removed by reduced-pressure filtration through $0.5{\mu}m$ membrane filter and the number of the particulates was measured by particulate counter to confirm the removal of impure particles.

Development and Performance Evaluation of Air-Supplied Mask (분진의 인체내 유입을 차단하기 위한 송기 마스크의 개발 및 성능평가)

  • Kim, Min Cheol;Kim, Hyun Tae;Lee, Kyoo Won
    • Clean Technology
    • /
    • v.4 no.1
    • /
    • pp.60-67
    • /
    • 1998
  • As workers' health and welfare are becoming increasingly important, there are needs for protecting workers from being exposed to dust particles in workplace. One of the simplest ways to protect workers is to wear a one-time-use mask of the 3M type. Although conventional masks are convenient to use, they provide low filtration efficiency simply because of air leaks through interface between the face and the mask. In this study, a new type of mask is developed and tested. The air which is filtered first using high efficiency particulate air(HEPA) filter is supplied to the nose area of workers' face. The developed mask was tested for filtration efficiency and for workers' acceptance. Very good results were obtained for both accounts.

  • PDF

Use of laminar flow water storage tank (LFWS) to mitigate the membrane fouling for reuse of wastewater from wafer processes

  • Sun, Darren Delai;Wu, You
    • Membrane and Water Treatment
    • /
    • v.3 no.4
    • /
    • pp.221-230
    • /
    • 2012
  • This study employed the modified fouling index (MFI) to determine the performance of a two-step recycling system - a membrane filtration integrated laminar flow water storage (LFWS) tank followed by an ion exchange process to reclaim ultrapure water (UPW) from the wastewater generated from semiconductor wafer backgrinding and sawing processes. The first step consisted of the utilization of either ultrafiltration (UF) or nanofiltration (NF) membranes to remove solids in the wastewater where the second step consisted of an ion exchanger to further purify the filtrate. The system was able to produce high purity water in a continuous operating mode. However, higher recycling cost could be incurred due to membrane fouling. The feed wastewater used for this study contained high concentration of fine particles with low organic and ionic contents, hence membrane fouling was mainly attributed to particulate deposition and cake formation. Based on the MFI results, a LFWS tank that was equipped with a turbulence reducer with a pair of auto-valves was developed and found effective in minimizing fouling by discharging concentrated wastewater prior to any membrane filtration. By comparing flux behaviors of the improved system with the conventional system, the former maintained a high flux than the latter at the end of the experiment.

Filtration Performance Evaluation of Various Respiratory Face Masks Against Sub-Micron Particles (다양한 호흡기 보호용 면체 마스크의 서브 마이크론 입자에 대한 여과 성능 평가)

  • Zainul Alim Ali Murtadlo;Cho Hee-Joo;Park Hyun-Seol
    • Particle and aerosol research
    • /
    • v.19 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • Respiratory face masks are protective facepieces that are designed to filter inhaled air. They are easy-to-use devices that can protect the wearer against various hazardous particles in the air. Respiratory face masks also prevent the spread of viruses and bacteria-containing droplets that are released from the coughing or sneezing of the infected people. During the COVID-19 pandemic, various types of face masks have circulated on the market. Their ability to filter sub-micron particles, which are the sizes of harmful particulate matter and airborne viruses, needs to be investigated. Their breathability, the easiness of breath through the mask, also needs to be considered. In this study, wwe evaluated the performance of filters used for different types of face masks certified by different standards including Korean (KF94, KF80, KF-AD), USA (N95), and Chinese (KN95) standards. We also tested the filters of nanofiber masks and surgical masks for which there are no standards for filtration test. The N95 mask filters showed the highest quality factor for capturing virus-sized particles. The other types of mask filters have acceptable performance except for nanofiber mask filters whose performance is very low.

Removal Performance of Sticky Paint Aerosol Control System Generated from Small Scale Car Paint Overspray Booth (소형 자동차 페인트 도장부스에서 발생하는 점착성 paint aerosol 처리장치에서 제거성능)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Sohn, Jong-Ryeul;Park, Young-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.1
    • /
    • pp.54-62
    • /
    • 2015
  • Small scale paint overspray booths are being operated nationwidely, for repair of passenger car body parts. paint aerosols are emitted from the paint overspray booth in operations. In paint overspray booth operations without ventilation system and air pollutants collection unit, it may land on nearby equipment. In this study a removal of sticky paint aerosol for application of the small-scale overspray paint booth. it's cause the surface of filter bag from generated sticky paint aerosol. To remove adhesion of paint aerosol the agglomerating agents are injected and mixed with sticky paint aerosols prior to reach the filter bag. The paint spray rate was set as $10{\pm}5g/min$ from air-atomized spray guns in the spray booth, injection rate of agglomerating was $10{\pm}5g/min$ in the mixing chamber. The filtration velocity including air pollutants varied from 0.2 m/min to 0.4 m/min. Bag cleaning air pressure was set as $5.0kg_f/min$ for detaching dust cake from surface of filter bag. Bag cleaning interval at the filtration velocity of 0.2 m/min was around 3 times longer than that of the 0.4 m/min. The residual pressure drop maintained highest value at the highest filtration velocity. Fractional efficiency of 99.952%~99.971% was possible to maintain for the particle size of 2.5 microns. Total collection efficiency at the filtration velocity of 0.2 m/min was 99.42%. During this study we could confirm high collection efficiency and long cleaning intervals for the test with filtration velocity of 0.2 m/min indicating an optimal value for the given dimensions of the test unit and test operating conditions.

Experimental Evaluation of Particulate-matter Filtration Performance of a Bottom Ash-Silica Sand Mixture (석탄 저회-규사 필터의 입자상물질 여과 성능 실험적 평가)

  • Lee, Dong-Hyun;Lee, Hong-Kyoung;Lee, Yun-Jae;An, Jaehun
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.6
    • /
    • pp.41-47
    • /
    • 2022
  • Permeable pavement technology allows the penetration of rainfall into the roadbed, thereby reducing surface runoff and enhancing water quality. The water quality can be improved by adding a filter layer to the permeable pavement. This study analyzes the permeability performance and particulate-matter removal efficiency of a bottom ash-silica sand filter. The performances of five filters with bottom ash and silica sand as the basic materials were evaluated on particulate matter sized 60 ㎛ or smaller. The pure silica sand sample and pure bottom ash sample delivered an average removal efficiency of around 70%. The removal efficiency of the mixed sample was approximately 90%, exceeding the recommended reduction rate (80%) at non-point pollution reduction facilities. In future work, the filter performance should be further verified on permeable pavement.

An Experimental Study on the Production Rate and Contaminant Removal of Filtrate in Multi-purpose Filtration Pond (다목적 여과저류지에서 여과수의 산출율과 수질개선도에 관한 실험연구)

  • Jeong, Jae-Min;Choi, Hong-Gyu;Jung, Kwan-Sue;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.7
    • /
    • pp.518-524
    • /
    • 2013
  • A pilot-scale test-bed was operated employing three soils with different grain sizes dredged from the Nakdong River to obtain the design and operation parameters of the multi-purpose filtration pond, such as the filtrate productivity of the filter sand, the appropriate removal period of the surface clogging and the contaminant removal efficiency. The cross-flow velocities were applied stepwise ranging from 0 to 40 cm/sec in order to simulate the various velocities in the artificial stream of the pond. Results showed that a filtrate production rate of 5~3 $m^3/m^2-day$ was maintained by removing the surface clogging every 7 to 13 days and that the filtrate quality was not affected by the factors of the filtrate production rate, the grain size of the filter sand and the cross-flow velocity. Results also showed that most of the removal occurred within 50 cm of the top soil and that the removal efficiencies with the filtration distance of 2.4 m were 80~95% for turbidity, 20~30% for COD, 75~90% for BOD, 5~20% for total nitrogen and 20~60% for total phosphorus, which suggested that particulate matters had a high removal efficiency.

A Study on Operating Condition of Test-Bed Plant using Membrane filtration of D Water Treatment Plant in Gwang-Ju (D정수장 정밀여과막 실증플랜트의 최적 운전조건 연구)

  • Yang, Hyung-Jae;Yi, Seung-Hoon;Moon, Kyung-Ran
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.155-163
    • /
    • 2017
  • Membrane filtration has become more popular in drinking water treatment recently, since the filtration can control not only particulate matters but also pathogenic microorganisms such as giardia and cryptosporidium very effectively. Pilot-scale ($120m^3/d$ of treatment capacity) and test-bed ($25,000m^3/d$ of treatment capacity) microfiltration experiments were conducted to find optimum operating mode and the critical flux. Optimum operating mode of pilot-test was assessed as inflow 1.0 min, filtration 36.5 min, air backwash 0.9 min, backwash 1.0 min and outflow 1.0 min with 50 LMH ($L/min{\cdot}m3^$) of critical flux. Critical Flux was calculated to be $50L/m^2-h$ (within TMP 0.5 bar) based on the increase formula of the transmembrane pressure difference according to the change of time at Flux 20, 40, 56 and 62 LMH in pilot operation. Chemical cleaning was first acid washed twice, and alkali washing was performed secondarily, and a recovery rate of 95% was obtained in the test-bed plant. The results of operating under these appropriate conditions are as follows. Turbidity of treated water were 0.028, 0.024, 0.026 and 0.028 NTU in spring, summer, autumn and winter time, respectively. Microfiltration has superior treatment capability and performance characteristics in removing suspended solids and colloidal materials, which are the main cause of turbidity and important carrier of metal elements, and it has shown great potential in being an economically substitute to traditional processes (sand filtration).