• 제목/요약/키워드: Particulate air pollution

검색결과 434건 처리시간 0.026초

CR-DPF와 Cooled-EGR 적용한 대형디젤기관 성능에 관한 연구 (A Study on Heavy-Duty Diesel Engine Performance with a CR-DPF and Cooled-EGR)

  • 문병철;오용석;오상기;강금원;안균재
    • 한국자동차공학회논문집
    • /
    • 제14권3호
    • /
    • pp.75-80
    • /
    • 2006
  • Since air pollution has become a globally critical issue and exhaust emissions from automobiles cause a major source of air pollution, many countries including advanced countries have stipulated stringent emission regulations. Particularly in diesel vehicles, NOx and particulate matters exhaust in significant amounts even though diesel vehicles provide merits in aspects of higher thermal efficiency and lower $CO_2$. To reduce Particulate matters and NOx, after-treatment technology such as filter trap, oxidation catalysts and EGR has been applied. This test was conducted on the effect of continuous regeneration diesel particulate filter and cooled-EGR, and 15ppm low sulfur diesel was used as a test fuel. Exhaust emissions, PM, NOx, CO, HC and Soots were measured and compared under D-13 and D-3 modes.

메타버스 리얼리티를 위한 공유 모빌리티 기반 국부적 미세먼지 관측 기술 연구 (A Study on the Local Particulate Matter Monitoring Technology using Shared-Use Mobilities for Metaverse Reality)

  • 정인택;장봉주
    • 한국멀티미디어학회논문지
    • /
    • 제24권8호
    • /
    • pp.1138-1148
    • /
    • 2021
  • In this study, we developed a 'shared-use mobility'-mounted local particulate matter monitoring terminal technology to measure the actual particulate matter concentration around me. As a mobile terminal device in the form of an IoT sensor platform, it is designed to be separated into a control module and a sensor module to minimize interference between sensors and to consider the optimal observation position of each sensor. As a result of the field test, it was confirmed that particulate matter was locally different depending on time and space even within the same area. In addition, it was confirmed that the concentration of particulate matter in the relevant section differed by up to 100 times compared to the surrounding area due to specific sources of particulate matter such as unpaved roads. In addition, we positively reviewed the applicability of the service in the real-time metaverse environment using this result. Through technological advancement and application of multiple shared-use mobilities, we expect to be able to provide new services for practical smart city air environment monitoring, such as localized particulate matter information, air pollution event information, and identification of causes of particulate matter.

디젤기관에서 전기 히터 재생 여과 트랩의 특성에 관한 연구 (A Study on Characteristics of Electric Heater Regeneration Filter Trap in Diesel Engine)

  • 류규현;박만재
    • 한국공작기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.10-15
    • /
    • 2001
  • Urgent increasing of the vehicles influence air pollution and the damage of the plants and animals. Particularly, exhaust-ing particulate of diesel vehicles give serious effect to human life. Therefore, this study aim to reduce amount of particulate and to contribute developing after-treatment in diesel engine. Through the experimental and theoretical study about charac-teristics of the electric heat regeneration, various results are obtained.

  • PDF

중앙차선 버스 정류장과 주변지역의 대기오염 특성 비교 (Comparison of Air Pollution Characteristics in the Center Lane-Bus Stop and the Surrounding Areas)

  • 이용기;김웅수;홍순모;신은상
    • 한국대기환경학회지
    • /
    • 제30권4호
    • /
    • pp.378-386
    • /
    • 2014
  • The use of bus stop in the center lane has reduced the emissions of exhaust gas on the road due to the improvement of the traffic speed but has caused a health problem for the citizens who are waiting for the bus in the platform, and thus the air pollution control of bus stop in the center lane is emerging as a more important part. This study was conducted to investigate the air pollution degree for the center lane-bus stops in four regions using mobile air measuring vehicle, and to evaluate the characteristics of air pollution by comparing with the data measured at the urban air monitoring site close to the bus stops. In addition, the correlation analysis was performed to analyze the impact to neighboring region by vehicle exhaust gas. The regional mean concentration of nitrogen dioxide in the center lane-bus stops ranged from 0.025 to 0.043 ppm which shows from 2.5 times to 5.3 times higher than the values of urban air monitoring site selected as a control group. The regional mean concentration of ozone in the center lane-bus stops ranged from 0.023 to 0.034 ppm which shows from 3% to 28% lower than the values of urban air monitoring site selected as a control group. The concentrations of nitrogen dioxide and ozone for the sampling regions did not exceed one hour-air quality environmental standard (0.1 ppm). The mean concentration of particulate matter for four center lane-bus stops was $28{\mu}g/m^3$ which shows about 27% higher than the values of urban air monitoring site selected as a control group, and that of particulate matter did not exceed one day-air quality environmental standard ($100{\mu}g/m^3$). In the results of correlation analysis between data from center lane-bus stops and data from urban air monitoring sites, the correlation coefficient (r) of nitrogen dioxide was relatively low as 0.316 to 0.416, and the correlation coefficient was high as the distance was close and vice versa. However, the correlation coefficient of ozone ranged from 0.167 to 0.658 and the correlation coefficient was high as the distance was far and vice versa.

도시철도 터널 내 청소장치별 집진먼지 비교 분석 (A Comparative Analysis of Dust Particles Collected by Cleaning Equipments in Subway Tunnel)

  • 이영권;김일홍;조병기;김만화;박종헌
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1388-1398
    • /
    • 2011
  • Air pollution in subway tunnel is primarily caused from the wear of metallic materials. As undesirable substance, PM(Particulate Matter) can especially harm the health of passengers and workers as well as clog the main parts of rolling stock such as inverters. To improve the air quality in subway tunnel, SMRT(Seoul Metropolitan Rapid Transit Corporation) has developed anti-pollution devices such as Magnetic Dust Collector, Vacuum Cleaner For Rail Road and Particulate Removing Sprinkler Vehicle. Introducing these mechanical devices, this paper is mainly devoted to explaining the characteristics of collected dust according to the result of particle-size analysis and componential analysis.

  • PDF

ULSD, CR-DPF와 EGR을 적용한 디젤기관의 배출가스에 관한 연구 (A Study on Exhaust Gas of Diesel Engine with a ULSD, CR-DPF and EGR)

  • 문병철;오용석
    • 한국공작기계학회논문집
    • /
    • 제15권5호
    • /
    • pp.85-90
    • /
    • 2006
  • Since air pollution has become a globally critical issue and exhaust emissions from automobiles cause a major source of air pollution, many countries including advanced countries have stipulated stringent emission regulations. This test was conducted on the effect of continuous regeneration diesel particulate filter and cooled-EGR, and 15ppm low sulfur diesel was used as a test fuel. Exhaust emissions, PM, NOx, CO, HC and Soots were measured and compared under D-13modes. Through durability test on diesel particulate filter, regeneration characteristics and control technology on PM were investigated in overall.

Numerical Simulation of Extreme Air Pollution by Fine Particulate Matter in China in Winter 2013

  • Shimadera, Hikari;Hayami, Hiroshi;Ohara, Toshimasa;Morino, Yu;Takami, Akinori;Irei, Satoshi
    • Asian Journal of Atmospheric Environment
    • /
    • 제8권1호
    • /
    • pp.25-34
    • /
    • 2014
  • In winter 2013, extreme air pollution by fine particulate matter ($PM_{2.5}$) in China attracted much public attention. In order to simulate the $PM_{2.5}$ pollution, the Community Multiscale Air Quality model driven by the Weather Research and Forecasting model was applied to East Asia in a period from 1 January 2013 to 5 February 2013. The model generally reproduced $PM_{2.5}$ concentration in China with emission data in the year 2006. Therefore, the extreme $PM_{2.5}$ pollution seems to be mainly attributed to meteorological (weak wind and stable) conditions rather than emission increases in the past several years. The model well simulated temporal and spatial variations in $PM_{2.5}$ concentrations in Japan as well as China, indicating that the model well captured characteristics of the $PM_{2.5}$ pollutions in both areas on the windward and leeward sides in East Asia in the study period. In addition, contribution rates of four anthropogenic emission sectors (power generation, industrial, residential and transportation) in China to $PM_{2.5}$ concentration were estimated by conducting zero-out emission sensitivity runs. Among the four sectors, the residential sector had the highest contribution to $PM_{2.5}$ concentration. Therefore, the extreme $PM_{2.5}$ pollution may be also attributed to large emissions from combustion for heating in cold regions in China.

Effects of diesel exhaust and it′s particles on respiratory and reproductive Systems in mice

  • Sagai, Masaru
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 1999년도 추계학술대회 논문집
    • /
    • pp.289-292
    • /
    • 1999
  • In recent year, there has been a progressive increase in urban air pollution that is Characterized by high concentrations of atmospheric particulate matter (PM10), resulting primarily from increase of automobils, especially diesel engine powered cars. Although the mechanisms of underling respiratory morbidity due to PM10 are not nuclear, it is thought that the fine particles (PM2.5) are of gratest concern to health since they can be breathed most deeply into the lung, where they are likely to be more toxic than the larger particles.(omitted)

  • PDF

실내 외 미세먼지 측정 및 관리 기술 동향 (Indoor and Outdoor Particulate Matter: The Current and Future in Monitoring, Assessment, and Management)

  • 김재진;최원식;김진수;노영민;손윤석;양민준
    • 대한원격탐사학회지
    • /
    • 제36권6_3호
    • /
    • pp.1635-1641
    • /
    • 2020
  • 대기오염은 최근 급속한 인구증가와 산업화 등으로 인해 인류가 해결해야 할 중요한 문제로 인식되고 있다. 특히 미세먼지 노출에 따른 질병 사례들의 증가와 대기 질 정보에 대한 국민의 관심 증대로 인해 미세먼지는 환경문제를 넘어 사회적 재난 수준의 심각한 이슈로 대두되고 있다. 아울러 대기 중 미세먼지 농도는 실내 미세먼지 농도에 밀접하게 관여하여 실내 공기질의 악화를 야기시킬 수 있다. 따라서 실내외 미세먼지 측정, 모델링, 기여도 평가를 통한 오염 특성을 이해하고, 이를 과학적으로 규명하는 것은 매우 중요하다. 본 특별호는 부경대학교 i-SEED 지구환경교육연구단과 학교미세먼지관리 기술개발사업단에서 진행하고 있는 다양하고 흥미로운 실내외 미세먼지 측정과 관리 기술에 대한 여러 연구들을 소개한다. 이를 통하여 실내외 미세먼지 측정과 관리 기술에 대한 현 주소를 파악하고 참여 연구그룹의 연구 결과에 대한 정보 공유에 본 특별호가 기여하길 기대한다. 더불어 미세먼지에 관련한 지속적인 연구주제 발굴과 국가적인 지원을 이끌어 내기 위한 관련 전문가들의 노력을 기대한다.

대기오염물질이 손상으로 인한 손실수명연수에 미치는 영향: 서울특별시를 중심으로 (Effect of Ambient Air Pollution on Years of Life Lost from Deaths due to Injury in Seoul, South Korea)

  • 강선우;정수빈;이혜원
    • 한국환경보건학회지
    • /
    • 제49권3호
    • /
    • pp.149-158
    • /
    • 2023
  • Background: Injury is one of the major health problems in South Korea. Few studies have evaluated both intentional and unintentional injury when investigating the association between exposure to air pollutants and injury. Objectives: We aimed to explore the association between short-term exposure to ambient air pollution and years of life lost (YLLs) due to injury. Methods: Data on daily YLLs for 2002~2019 were obtained from the the Death Statistics Database of the Korean National Statistical Office. This study estimated short-term exposure to particulate matter with an aerodynamic diameter of <10 ㎛ (PM10), particulate matter with an aerodynamic diameter of <2.5 ㎛ (PM2.5), sulfur dioxide (SO2), nitrogen dioxide (NO2), carbon monoxide (CO), and ozone (O3). This time series study was conducted using a generalized additive model (GAM) assuming a Gaussian distribution. We also evaluated a delayed effect of ambient air pollution by constructing a lag structure up to seven days. The best-fitting lag was selected based on smallest generalized cross validation (GCV) value. To explore effect modification by intentionality of injury (i.e., intentional injury [self-harm, assault] and unintentional injury), we conducted stratified subgroup analyses. Additionally, we stratified unintentional injury by mechanism (traffic accident, fall, etc.). Results: During the study period, the average daily YLLs due to injury was 307.5 years. In the intentional injury, YLLs due to self-harm and assault showed positive association with air pollutants. In the unintentional injury, YLLs due to fall, electric current, fire and poisoning showed positive association with air pollutants, whereas YLLs due to traffic accident, mechanical force and drowning/submersion showed negative associations with air pollutants. Conclusions: Injury is recognized as preventable, and effective strategies to create a safe society are important. Therefore, we need to establish strategies to prevent injury and consider air pollutants in this regard.