• Title/Summary/Keyword: Particulate matter

Search Result 1,470, Processing Time 0.032 seconds

An Experimental Study on the Smoke Filtration System Using Water Injection and Vacuum Pump driven by Exhaust Gas (물 분사 및 배기가스 구동형 진공펌프를 이용한 매연여과장치에 대한 실험적 연구)

  • Lee, Han-Sung;Kim, Kyong-Hyon;Jung, Suk-Ho;Koh, Dae-Kwon
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.17-22
    • /
    • 2013
  • Diesel particulate filter has been adopted in new vehicle with diesel engine. Since the flow of exhaust gas was clogged as particulate matters were deposited in the filter, it have bad effects on a fuel consumption and power. It was investigated that a particulate filtering system with vacuum pump in the exhaust gas line could be free from clogging in previous research. In this study, the effects of water injection and position of inlet port in filtering system on reducing in particulate matter were investigated. It was noticed that particulate matter were decreased remarkable by water injection and moving the position of inlet port.

Performance Evaluation of an Electrohydrodynamic Spray Nozzle for Regeneration of Particulate Matter on Diesel Particulate Filter (경유차 입자상물질 저감필터(DPF) 재생용 전기수력학적 연료 후분사 노즐의 미립화 특성 평가 및 수치해석을 이용한 액적 입경별 연소 특성 평가)

  • Jeong, Seonghun;Park, Sung-Eun;Kim, Min-Jung;Cho, Hyung-Jei;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.8 no.2
    • /
    • pp.55-68
    • /
    • 2012
  • Particulate matters (PM) which are collected into a diesel particulate filter (DPF) system have to be periodically removed by thermal oxidation. In this report, we fabricated an electrohydrodynamic-assisted pressure-swirl nozzle to spray diesel droplets finer. Atomization performance of the nozzle was evaluated using both experimental and numerical methods. Two types of nozzle designs, the charge induction type and the charge injection type, were tested. While the former generated diesel droplets of $400\;{\mu}m$ at an applied electric potential over 10 kV, the latter presented the droplets smaller than $23\;{\mu}m$ at an applied electric potential of 8 kV. The numerical simulation results showed that the reduced size of droplets caused higher evaporation of droplets and therefore the increased temperature, which would eventually increase the regeneration performance of the DPF system.

Demonstration of a Modular Electrostatic Precipitator to Control Particulate Emissions from a Small Municipal Waste Incinerator

  • Intra, Panich;Yawootti, Artit;Tippayawong, Nakorn
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.239-246
    • /
    • 2014
  • Incineration is conceptually sound as a waste treatment technology. There is, however, concern over its emissions when it is improperly designed and operated. An electrostatic precipitator is one of the most commonly used devices to control particulate emissions from boilers, incinerators and some other industrial processes. In this work, a modular electrostatic precipitator with sizing of $1m{\times}1m{\times}1m$ was developed for removal of particulate matter from the exhaust gases of a small waste incinerator. Its design was based on a simple wire-and-plate concept. The corona discharge wires were connected to a positive high-voltage pulse generator, while the collection plates were grounded. The high-voltage pulse generator was used to produce the corona discharge field between the individual discharge wire and the collection plate. The particulate-laden exhaust gas flow was directed across the corona discharge field. The charged particles were deflected outward and collected on the plate. The collection efficiency was evaluated as a mass loading ratio between the difference at the inlet and the outlet to the particulate loading at the inlet of the precipitator. The collection efficiency of this modular electrostatic precipitator design was approximately 80 %.

Reduction Effect of Air Cleaner on Particulate Matters and Biological Agents in a Swine Facility (공기정화기 적용에 따른 돈사 작업장내 입자상 물질 및 생물학상 물질 저감 효과에 관한 연구)

  • Kim, Ki Youn
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.1
    • /
    • pp.70-76
    • /
    • 2017
  • Objectives: This on-site study was performed to evaluate the reduction efficiency of an air cleaner on particulate matters and biological agents in a swine facility. Materials and Methods: Particulate matter was measured using a real-time monitoring recorder and biological agents were sampled with a one-stage impactor and then analyzed based on the microbial culture method. An experimental process for the reduction effect on airborne pollutants through air cleaner operation consisted of three conditions: no treatment, wet scrapper by water spray and wet scrapper by disinfectant spray. Results: Geometric mean levels of particulate matter(TSP, $PM_{10}$, $PM_{2.5}$ and $PM_1$) were presented at $1,608{\mu}g/m^3$, $1,373.8{\mu}g/m^3$, $401.8{\mu}g/m^3$ and $144.5{\mu}g/m^3$ for no treatment; $1,503{\mu}g/m^3$, $1,017{\mu}g/m^3$, $159.4{\mu}g/m^3$ and $69.8{\mu}g/m^3$ for wet scrapper by water spray; and $1,222.17{\mu}g/m^3$, $477.17{\mu}g/m^3$, $33.2{\mu}g/m^3$ and $11.1{\mu}g/m^3$ for wet scrapper by disinfectant spray, respectively. In the case of biological agents, the geometric averaged concentrations of total airborne bacteria and fungi were as follows: $45,371cfu/m^3$ and $13,474cfu/m^3$ for no treatment, $43,286cfu/m^3$ and $8,610cfu/m^3$ for wet scrapper by water spray, and $2,440cfu/m^3$ and 1,867 cfu/ for wet scrapper by disinfectant spray, respectively. Regardless of particulate matter and biological agent, the highest concentrations were found for no treatment, while the lowest concentrations were found with wet scrapper by disinfectant spray. Conclusions: Based on the results obtained from this on-site evaluation, there was a significant reduction effect on particulate matter and biological agents through the application of an air cleaner in this study.

Study on the On-Board Test of After-Treatment Systems to Reduce PM-NOx in Low-Speed Marine Diesel Engine (선박용 저속디젤엔진 적용을 위한 PM-NOx 동시저감 배출저감설비 해상실증 연구)

  • Dong-Kyun Ko;Suk-Young Jeong;In-Seob Kim;Gye-Won An;Youn-Woo Nam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.5
    • /
    • pp.497-504
    • /
    • 2023
  • In this study, Selective catalytic reduction (SCR) + Diesel particulate filter (DPF) system was installed on a ship with a low-speed engine to conduct the on-board test. The target ship (2,881 gross tons, rated power 1,470 kW@240 rpm ×1) is a general cargo ship sailing in the coastal area. Drawing development, approvals and temporary survey of the ship were performed for the installation of the after-treatment system. For performance evaluation, the gaseous emission analyzer was used according to the NOx technical code and ISO-8178 method of measurement. The particulate matter analyzer used a smoke meter to measure black carbon, as discussed by the International Maritime Organization (IMO). Tests were conducted using MGO (0.043%) and LSFO (0.42%) fuels according to the sulfur content. The test conditions were selected by considering the engine rpm (130, 160 and 180). Gaseous emission and particulate matter (smoke) were measured according to the test conditions to confirm the reduction efficiency of the after treatment system. The results of NOx emission and particulate matter (smoke) revealed that reduction efficiency was more than 90%. The exhaust pressure met the allowable back pressure (less than 50 mbar). This study confirms the importance of the on-board test and the potential of SCR + DPF systems as a response technology for reducing nitrogen oxides and particulate matter.

A Study on the Influence on Medical Care for the Elderly by Exposure to Fine Particulate Matter and Ozone (미세먼지와 오존노출에 의한 노인의 의료 이용 영향에 대한 연구)

  • Jung, En-Joo;Na, Wonwoong;Lee, Kyung-Eun;Jang, Jae-Yeon
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.1
    • /
    • pp.30-41
    • /
    • 2019
  • Objectives: The effects of particulate matter and ozone on health are being reported in a number of studies. These effects are likely to be stronger on the elderly population, but studies in this regard are scarce. The purpose of this study was to examine the effects of particulate matter ${\leq}2.5{\mu}m$ and ozone on the acute health status of the elderly population. Methods: In order to analyze the health status of the elderly population, the NHIS-Senior Cohort data was used. In this study of people 60 years or older in Seoul, the number of outpatient visits and ER visits between 2002 and 2013 were calculated. Each disorder and the lag effect were analyzed separately. Particulate matter and ozone were analyzed using both the single exposure model and the adjusted multi-exposure model. Results: In the single exposure analysis with PM2.5 as the exposure variable, with each increase of $10{\mu}g/m^3$, the number of outpatient visits increased by 1.0081 times, vascular disease 1.0065 times, chronic pulmonary disease 1.0086 times, and diabetes 1.0055 times. In the multi-exposure model adjusting for ozone, the number of outpatient visits increased by 1.0066 times. There was a one-day lag effect and 1.0066 times increase between PM2.5 and ER visits in the multi-exposure model and 1.0057 times when adjusted for ozone (p value <0.10). There was a one-day lag effect in all multi-exposure models with ozone as the main variable, and when the particulate matter was adjusted, there was a one-day delay and 1.0143 times increase in ER visits. Conclusions: In our study, an increase in the number of outpatient and ER visits in the elderly population in accordance with the increase in PM2.5 and ozone was found. The association found in our study could also produce a socioeconomic burden. Future studies need to be performed in regards to younger populations and other air pollutants.

Evaluation of Particulate Matter's Traits and Reduction Effects in Urban Forest, Seoul (서울 청량리 교통섬과 홍릉숲의 미세먼지 특성과 저감효과 평가)

  • Kim, Pyung-Rae;Park, Chan-Ryul
    • Korean Journal of Environment and Ecology
    • /
    • v.35 no.5
    • /
    • pp.569-575
    • /
    • 2021
  • This study analyzed the effect of forests on reducing particulate matter by investigating the particulate matter concentration and influencing factors between urban forest and traffic forest. The concentrations of particulate matter in Hongreung Experimental Forest (urban forest) and a forest (traffic forest) formed at the intersection of Cheongryangri Station in Dongdaemun-gu, Seoul were measured with the light scattering method instrument from January to November 2018. During the study period, the average PM10 concentrations in the urban forest and the traffic forest were 12.5㎍/m3 and 15.7 ㎍/m3, respectively, and the average PM2.5 concentrations were 16.6㎍/m3and 6.9 ㎍/m3, respectively. Comparing the concentration by the urban atmospheric measurement network of the Ministry of Environment and the concentration in urban forests showed that the reduction rate of PM10 was 66.9±28.6% in urbanforest and 58.6±44.1% in traffic forest and that of PM2.5 was 71.3±23.0% and 64.9±31.3%. The difference in the reduction rate of particulate matter is likely related to the size and structure of the urban forest, and the wind velocity is considered the reduction factor.

Factors Affecting the Perception, Knowledge, and Preventive Behaviors of Chronic Pulmonary Disease Patients on Particulate Matter (만성호흡기질환자의 미세먼지에 대한 인식, 지식, 예방행위와 관련 요인)

  • Bang, So-Hee;Hwang, Tae-Yoon
    • Journal of agricultural medicine and community health
    • /
    • v.46 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • Objectives: This research aimed to identify the level of perception, knowledge, preventive behavior, and factors affecting preventive behavior of patients with asthma and chronic obstructive pulmonary disease against particulate matter. Methods: This research was a descriptive survey research, and the subjects were chronic pulmonary disease patients over the age of 19 and under 80 who visited a university hospital in Daegu City. Data was collected by convenience sampling through structured self-administered questionnaire survey from December 2019 to January 2020, and a total of 212 copies were used for analysis. Results: Out of 212 total subjects, 112 were asthma patients (52.8%) and 100 were chronic obstructive pulmonary disease patients (47.2%). The average score (out of 10) of perception, knowledge and preventive behavior of patients with asthma for particulate matter was 7.92, 6.99, and 7.10, respectively, while those with chronic obstructive pulmonary disease scored 7.72, 6.24, and 6.80, respectively. The knowledge score was significantly higher in patients with asthma than those with chronic obstructive pulmonary disease (p=0.007). Factors affecting particulate matter preventive behavior were perception score, knowledge score, and age for asthma patients, and perception score for chronic obstructive pulmonary disease patients. Conclusions: As a result of the above, the factors relate to the preventive behavior of patients with asthma and chronic obstructive pulmonary disease were perception score, knowledge score, and age for asthma, and perception score for chronic obstructive pulmonary disease. Raising the level of particulate matter preventive behavior can prevent the deterioration of chronic pulmonary diseases caused by particulate matter, so the development of arbitration programs considering the characteristics of the patients according to the disease and continuous and repetitive education are required.

Experimental Study on a Corona Charger for Real-time Monitoring of Particulate Matter (PM) (입자상물질(PM) 실시간 모니터링을 위한 코로나 입자하전기의 실험적 연구)

  • 권순박;정정선;이규원
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.04a
    • /
    • pp.227-228
    • /
    • 2002
  • 대기오염물질 중 입자상물질(particulate matter, PM)의 크기분포 측정은 주로 다단임팩터(cascade impactor)에 의해 이루어지고 있다. 임팩터 각 단에 포집된 입자의 무게를 측정하여 입자상물질의 크기 분포로 환산하는 다단임팩터는 입자의 샘플링에 많은 시간이 소모되며 필터의 전처리 및 무게측정과정이 번거롭고, 시간에 따른 농도분포의 추이를 파악할 수 없는 단점이 있다. (중략)

  • PDF

Relationship between Indoor and Outdoor Particulate Matter Concentrations in Japan

  • Nakai, Satoshi;Tamura, Kenji
    • Asian Journal of Atmospheric Environment
    • /
    • v.2 no.1
    • /
    • pp.68-74
    • /
    • 2008
  • We briefly show the results of indoor and personal $PM_{2.5}$ measurements in an epidemiologic study designed to evaluate the health risks of ambient $PM_{2.5}$ in Japan and the relationship between indoor and outdoor PM concentrations. The impact of indoor and outdoor PM pollution on health is described based on one morbidity study. The results of other studies on indoor $PM_{2.5}$ measurements are also described.