• 제목/요약/키워드: Particle size selectivity

검색결과 39건 처리시간 0.031초

Pentoxifylline과 Caffeine-theophylline Imprinted Polymers의 크로마토그래피 특성 (Chromatographic Characterization of Pentoxifylline and a Mixture of Caffeine-theophylline Imprinted Polymer)

  • 홍승표;왕덕선;구윤모;노경호
    • KSBB Journal
    • /
    • 제18권1호
    • /
    • pp.65-69
    • /
    • 2003
  • Pentoxifylline MIPs에서 시료와 기능성 단위체 사이에는 수소결합이 형성되었다. 수소결합의 능력은 분자구조상 질소원자의 위치에 의해 결정되어졌다. Pentoxifylline과 caffeine theophylline MIPs 모두는 구조상 유사한 시료들과 affinity가 증가하는 결과를 얻어냈다. 특히 caffiene-theophylline MIPs에서 높은 수치의 체류인자와 IF를 얻었다. 이러한 결과로 적합한 복합 주형분자를 사용할 때 우리가 원하는 목적시료만을 선택적으로 분리 할 수 있고 그러므로 solid phase extraction에 사용되기에 적합하다는 결과를 얻어냈다.

Formulation and Cytotoxicity of Ribosome-Inactivating Protein Mirabilis Jalapa L. Nanoparticles Using Alginate-Low Viscosity Chitosan Conjugated with Anti-Epcam Antibodies in the T47D Breast Cancer Cell Line

  • Wicaksono, Psycha Anindya;Sismindari, Sismindari;Martien, Ronny;Ismail, Hilda
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제17권4호
    • /
    • pp.2277-2284
    • /
    • 2016
  • Ribosome-inactivating protein (RIP) from Mirabilis jalapa L. leaves has cytotoxic effects on breast cancer cell lines but is less toxic towards normal cells. However, it can easily be degraded after administration so it needs to be formulated into nanoparticles to increase its resistance to enzymatic degradation. The objectives of this study were to develop a protein extract of M. jalapa L. leaves (RIP-MJ) incorporated into nanoparticles conjugated with Anti-EpCAM antibodies, and to determine its cytotoxicity and selectivity in the T47D breast cancer cell line. RIP-MJ was extracted from red-flowered M. jalapa L. leaves. Nanoparticles were formulated based on polyelectrolyte complexation using low viscosity chitosan and alginate, then chemically conjugated with anti-EpCAM antibody using EDAC based on carbodiimide reaction. RIP-MJ nanoparticles were characterised for the particle size, polydispersity index, zeta potential, particle morphology, and entrapment efficiency. The cytotoxicity of RIP-MJ nanoparticles against T47D and Vero cells was then determined with MTT assay. The optimal formula of RIP-MJ nanoparticles was obtained at the concentration of RIP-MJ, low viscosity chitosan and alginate respectively 0.05%, 1%, and 0.4% (m/v). RIP-MJ nanoparticles are hexagonal with high entrapment efficiency of 98.6%, average size of 130.7 nm, polydispersity index of 0.380 and zeta potential +26.33 mV. The $IC_{50}$ values of both anti-EpCAM-conjugated and non-conjugated RIP-MJ nanoparticles for T47D cells (13.3 and $14.9{\mu}g/mL$) were lower than for Vero cells (27.8 and $33.6{\mu}g/mL$). The $IC_{50}$ values of conjugated and non-conjugated RIP-MJ for both cells were much lower than $IC_{50}$ values of non-formulated RIP-MJ (>$500{\mu}g/mL$).

Synthesis of Silica Membranes on a Porous Stainless Steel by Sol-Gel Method and Effect of Preparation Conditions on Their Permselectivity

  • Lee, Dong-Wook;Nam, Seung-Eun;Sea, Bong-Kuk;Ihm, Son-Ki;Lee, Kew-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • 제25권9호
    • /
    • pp.1371-1378
    • /
    • 2004
  • A porous stainless steel (SUS) as a substrate of silica composite membranes for hydrogen purification was used to improve mechanical strength of the membranes for industrial application. The SUS support was successfully modified by using submicron Ni powder, $SiO_2$ sols with particle size of 500 nm and 150 nm in turns. Silica top layer was coated on the modified supports under various preparation conditions such as calcination temperature, dipping time and repeating number of dipping-drying process. The calcination temperature for proper sintering was between H ttig temperature and Tamman temperature of the coating materials. Maximum hydrogen selectivity was investigated by changing dipping time. As repeating number of dipping-drying process increased, permeances of nitrogen and hydrogen were decreased and $H_2/N_2$ selectivity was increased due to the reduction of non-selective pinholes and mesopores. For the silica membrane prepared under optimized conditions, permeance of hydrogen was about $3\;{\times}\;10^{-5}\;cm^3{\cdot}cm^{-2}{\cdot}s^{-1}{\cdot}cmHg^{-1}$ combined with $H_2/N_2$ seletivity of about 20.

Apoptosis and inhibition of human epithelial cancer cells by ZnO nanoparticles synthesized using plant extract

  • Koutu, Vaibhav;Rajawat, Shweta;Shastri, Lokesh;Malik, M.M.
    • Advances in nano research
    • /
    • 제7권4호
    • /
    • pp.233-240
    • /
    • 2019
  • The present research work reports in-vitro anti-cancer activity of biologically synthesized ZnO nanoparticles (ZnO NPs) against human carcinoma cells viz SCC-40, SK-MEL-2 and SCC-29B using Sulforhodamine-B (SRB) Assay. ZnO NPs were synthesized by a unique and novel biological route using Temperature-gradient phenomenon where the extract of combination of Catharanthus roseus (L.) G. Don (C. roseus), Azadirachta indica (A. indica), Ficus religiosa (F. religiosa) and NaOH solution were used as synthesis medium. The morphology of the ZnO NPs was characterized by Transmission Electron Microscopy (TEM). TEM images reveal that particle size of the samples reduces from 76 nm to 53 nm with the increase in reaction temperature and 68 nm to 38 nm with the increase in molar concentration of NaOH respectively. XRD study confirms the presence of elements and reduction in crystallite size with increase in reaction temperature and NaOH concentration. The diffraction peaks show broadening and a slight shift towards lower Bragg angle ($2{\theta}$) which represents the reduction in crystallite size as well as presence of uniform strain. The FTIR spectra of the extract show transmittance peak fingerprint of Zn-O bond and presence of bioactive molecules These NPs exhibit inhibition greater than 50% for SCC-40, SK-MEL-2 and SCC-29B cell lines and more than 50% cell kill for SCC-29B cells at concentrations < $80{\mu}g/ml$. Nanoparticles with smallest size have shown better anti-cancer activity and peculiar cell-selectivity. The combination of extracts of these plants with ZnO NPs can be used in targeted drug delivery as an effective anti-cancer agent, a potential application in cancer treatment.

활성탄을 이용한 Triton X-100 용액에서의 phenanthrene의 선택적 흡착에 관한 연구 (A Study on Selective Adsorption of Phenanthrene Dissolved in Triton X-100 Solution using Activated Carbons)

  • 안치규;김영미;우승한;박종문
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제11권2호
    • /
    • pp.13-21
    • /
    • 2006
  • 다환방향족 탄화수소는 화석연료의 사용 등으로 자연계에 유출되며, 매우 낮은 용해도로 인해 토양과 강한 결합을 형성하여 장기적으로 영향을 준다. 이러한 PAHs로 오염된 토양을 복원하기 위해 계면활성제를 사용한 토양세척 공법을 사용하게 되며, 공정 시 계면활성제의 사용으로 전체 복원 비용이 증가하게 된다. 이에 토양복원 시 사용된 계면활성제의 재사용을 위한 연구들이 많이 진행되고 있다. 본 연구에서는 활성탄을 이용한 계면활성제 재사용 기술을 개발하였다. 활성탄으로는 원료물질과 활성방법이 같고 입자 크기가 다른 세 가지 GAC(Darco 4-12, 12-20, 20-40 메쉬)를 사용하였으며, PAH로는 phenanthrene을 계면활성제로는 Triton X-100을 사용하여 회분식으로 실험을 수행하였다. 이때 Triton X-100 용액에서 phenanthrene의 선택적 흡착정도를 보기위해 선택도를 사용하였다. 실험결과 입자 크기가 작을수록, 비표면적과 기공 부피가 클수록 높은 선택도를 나타내었다. 선택도는 세 활성탄 모두 1보다 높아 Triton X-100 용액으로부터 phenanthrene이 효과적으로 분리됨을 알 수 있었다. 본 연구의 결과, PAHs와 같은 소수성물질로 오염된 토양의 세척시 발생하는 계면활성제 용액을 적절한 특성을 가진 활성탄을 이용하면 오염물질을 선택적으로 제거시킬 수 있음을 알 수 있다. 따라서 활성탄을 이용한 선택적 흡착을 이용하면 토양 세척시 계면활성제 사용량을 줄이게 되어 복원 비용을 절감하는 효과를 가져올 것으로 예상된다.

Simultaneous Analysis of Cholesterol Oxidation Products (COPs) in Powdered Milk Using HPLC/UV-Vis

  • Lee, Jin Joo;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2787-2794
    • /
    • 2013
  • Cholesterol and cholesterol oxidation products (COPs) may accumulate in foods of animal origin during processing or storage. An effective and sensitive analytical method was developed by increasing the UV absorption of compounds through derivatization by attaching a chromophore to the functional groups of cholesterols (cholesterol, 20-hydroxycholesterol, 7-ketocholesterol, cholestane-$3{\beta}$-$5{\alpha}$-$6{\beta}$-triol, 25-hydroxycholesterol, and $5,6{\alpha}$-epoxycholesterol). The influences of the reaction time, volume of reaction solvent, amounts of derivatizing reagent, and extraction solvents were investigated, as they may influence the reaction and extraction yield. The derivatized COPs were analyzed simultaneously on a C18 column (2.1 mm i.d. ${\times}$ 100 mm length, $3.5{\mu}m$ particle size) using a gradient elution with water and acetonitrile. The derivatized COPs showed increased sensitivity and selectivity in HPLC/UV-Vis. The LOD and LOQ were in the concentration ranges of 0.018-0.55 mg/kg and 0.059-1.84 mg/kg from the powdered milk. And the accuracy and precision were 78.1-116.7% and 1.1-9.9%, respectively.

FeAPSO-34재료의 합성과 메탄올 전환에 놓인 촉매적 성능 (Synthesis of FeAPSO-34 Materials and Their Catalytic Performance on Methanol Conversion)

  • 엄명헌;강미숙
    • 한국재료학회지
    • /
    • 제9권8호
    • /
    • pp.798-803
    • /
    • 1999
  • 본 연구는 SAPO-34 결정골격에 도입된 Fe(III)의 메탄올 전환성능에 미치는 영향에 중점을 두었다. 신속결정화법에 의해 높은 결정화도, 좁은 입자 분포도를 갖는 결정(FeAPSO-34; Si/Fe=40,20,5)들이 얻어졌으며, SRD와 SEM의 결과로부터, 골격에 도입된 Fe양이 증가할수록 결정화도는 감소하고, 그 입자크기도 아울러 감소함이 관찰되었다. 한편, 이들의 산성도는 골격에 도입된 Fe양이 증가할수록 감소하였고, 그 결과 메탄올 전환에 있어서 에틸렌의 선택성이 향상되는 결과를 가져왔다.

  • PDF

Slurry내 분산 안정제가 Ru CMP 거동에 미치는 영향 (The Effect of Dispersant in Slurry on Ru CMP behavior)

  • 조병권;김인권;박진구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.112-112
    • /
    • 2008
  • 최근 Ruthenium (Ru) 은 높은 화학적 안정성, 누설전류에 대한 높은 저항성, 저유전체와의 높은 안정성 등과 같은 특성으로 인해 금속층-유전막-금속층 캐패시터의 하부전극으로 각광받고 있다. 또한 Cu와의 우수한 Adhesion 특성으로 인해 Cu 배선에서의 Cu 확산 방지막으로도 주목받고 있다. 그러나 이렇게 형성된 Ru 하부전극의 각 캐패시터간의 분리와 평탄화를 위해서는 CMP 공정이 도입이 필요하다. 이러한 CMP 공정에 공급되는 Slurry 에는 부식액, pH 적정제, 연마입자 등이 첨가되는데 이때 연마입자가 응집하여 Slurry의 분산 안전성 저하에 영향을 줄수 있다. 이로 인해 응집된 Slurry는 Scratch와 Delamination 과 같은 표면 결함을 유발할 수 있으며, Slurry의 저장 안정성을 저하시켜 Slurry의 물리적 화학적 특성을 변화시킬 수 있다. 그리하여 본 연구에서는 Ru CMP Slurry에서의 Surfactant와 같은 분산 안정제에 따른 Surface tension, Zeta potential, Particle size, Sedimentation의 분석을 통해 Slurry 안정성에 대한 영향을 살펴보았다. 그 결과 pH9 조건의 31ppm Dispersant 농도에서 50%이상의 Sedimentation 상승효과를 얻을 수 있었다. 또한 선택된 Surfactant가 첨가된 Ru CMP Slurry를 제조하여 Ru wafer의 Static etch rate, Passivation film thickness 와 Wettability를 비교해 보았다. 그리고 CMP 공정을 실시하여 Ru의 Removal rate와 TEOS에대한 Selectivity를 측정해 보았다.

  • PDF

첨가제가 Ru CMP slurry의 안정화에 미치는 영향 (Effect of additives on the stability of Ru CMP slurry)

  • 조병권;김인권;강봉균;박진구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.50-50
    • /
    • 2007
  • 최근 DRAM 소자 내에서 Ruthenium (Ru) 은 높은 화학적 안정성, 누설전류에 대한 높은 저항성, 고유전체와의 높은 안정성등과 같은 특성으로 인해 금속층-유전막(insulator)-금속층 캐패시터에 대한 하부전극으로 각광받고 있다. 일반적으로 Ru은 화학적으로 매우 안정하여 습식 식각으로 제거하기 어려우며, 이로인해 건식 식각을 이용하여 Ru을 제거하는 것이 널리 통용되고 있다. 하지만 칵 캐패시터의 분리를 위해 Ru을 건식 식각할 경우, 유독한 $Ru0_4$ 가스가 발생할 수 있으며 Ru 하부전극의 탈균일한 표면과 몰드 산화막의 손실을 유발할 수 있다. 이로인해 각 캐패시터간의 분리와 평탄화를 위해 CMP 공정이 도입되게 되었다. 이러한 CMP 공정에 공급되는 슬러리에는 부식액, pH 적정제, 연마입자등이 첨가되는데 이때 연마입자가 응집하여 슬러리의 분산 안정성 저하에 영향을 줄 수 있다. 그리하여 본 연구에서는 Ru CMP Slurry에서의 surfactant와 같은 첨가제에 따른 zeta potential, particle size, sedimentation의 분석을 통해 slurry 안정성에 대란 영향을 살펴보았다. 또한 선택된 surfactant가 첨가된 Ru CMP Slurry를 제조하여 Ru의 removal rate와 TEOS에 대한 selectivity를 측정해 보았다.

  • PDF

Full validation of high-throughput bioanalytical method for the new drug in plasma by LC-MS/MS and its applicability to toxicokinetic analysis

  • Han, Sang-Beom
    • 한국독성학회:학술대회논문집
    • /
    • 한국독성학회 2006년도 추계학술대회
    • /
    • pp.65-74
    • /
    • 2006
  • Modem drug discovery requires rapid pharmacokinetic evaluation of chemically diverse compounds for early candidate selection. This demands the development of analytical methods that offer high-throughput of samples. Naturally, liquid chromatography / tandem mass spectrometry (LC-MS/MS) is choice of the analytical method because of its superior sensitivity and selectivity. As a result of the short analysis time(typically 3-5min) by LC-MS/MS, sample preparation has become the rate- determining step in the whole analytical cycle. Consequently tremendous efforts are being made to speed up and automate this step. In a typical automated 96-well SPE(solid-phase extraction) procedure, plasma samples are transferred to the 96-well SPE plate, internal standard and aqueous buffer solutions are added and then vacuum is applied using the robotic liquid handling system. It takes only 20-90 min to process 96 samples by automated SPE and the analyst is physically occupied for only approximately 10 min. Recently, the ultra-high flow rate liquid chromatography (turbulent-flow chromatography)has sparked a huge interest for rapid and direct quantitation of drugs in plasma. There is no sample preparation except for sample aliquotting, internal standard addition and centrifugation. This type of analysis is achieved by using a small diameter column with a large particle size(30-5O ${\mu}$m) and a high flow rate, typically between 3-5 ml/min. Silica-based monolithic HPLC columns contain a novel chromatographic support in which the traditional particulate packing has been replaced with a single, continuous network (monolith) of pcrous silica. The main advantage of such a network is decreased backpressure due to macropores (2 ${\mu}$m) throughout the network. This allows high flow rates, and hence fast analyses that are unattainable with traditional particulate columns. The reduction of particle diameter in HPLC results in increased column efficiency. use of small particles (<2 urn), however, requires p.essu.es beyond the traditional 6,000 psi of conventional pumping devices. Instrumental development in recent years has resulted in pumping devices capable of handling the requirements of columns packed with small particles. The staggered parallel HPLC system consists of four fully independent binary HPLC pumps, a modified auto sampler, and a series of switching and selector valves all controlled by a single computer program. The system improves sample throughput without sacrificing chromatographic separation or data quality. Sample throughput can be increased nearly four-fold without requiring significant changes in current analytical procedures. The process of Bioanalytical Method Validation is required by the FDA to assess and verify the performance of a chronlatographic method prior to its application in sample analysis. The validation should address the selectivity, linearity, accuracy, precision and stability of the method. This presentation will provide all overview of the work required to accomplish a full validation and show how a chromatographic method is suitable for toxirokinetic sample analysis. A liquid chromatography/tandem mass spectrometry (LC-MS/MS) method developed to quantitate drug levels in dog plasma will be used as an example of tile process.

  • PDF