• Title/Summary/Keyword: Particle size measurement

Search Result 441, Processing Time 0.023 seconds

The Study on Two-color PIV Algorithm for a Measurement of Droplet Velocity (액적의 속도 측정을 위한 이색 PIV 알고리즘 연구)

  • Lee, K.H.;Lee, C.S.;Oh, S.I.
    • Journal of ILASS-Korea
    • /
    • v.4 no.1
    • /
    • pp.13-18
    • /
    • 1999
  • It has been known that spray characteristics have an important effect on the mixture formation and directly influence the engine performances and the emissions. Up to now, the measurement of droplet size is well developed such as PDPA and PMAS though the behavior of small droplets during secondary atomization is not clear. Particle image velocimetry(PIV), a planar measuring technique, is a very efficient tool for studying complicated behavior and a fast and reliable method to track numerous droplets during injection. In this study, two-color scanning PIV is designed to obtain quasi-instantaneous two dimensional velocity data by using he-ion laser, rotating mirror and beam splitter. This PIV method which has high temporal and spatial resolution provides the information about the small complex droplet behavior.

  • PDF

Measurement of the Shear Rate-Dependent Thermal Conductivity for Suspension with Microparticles (미립자를 포함한 현탁액의 전단율에 의존적인 열전도율 측정)

  • Lee, Sung-Hyuk;Shin, Sehyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.8
    • /
    • pp.1141-1151
    • /
    • 1998
  • An effective thermal conductivity measurement for suspensions of microparticles in oil mixture is conducted in order to evaluate the shear rate-dependence of the thermal conductivity of suspensions. Measurements are made for rotating Couette flows between two concentric cylinders. The rotating outer cylinder is immersed into a constant temperature water bath while the stationary inner cylinder is subject to a uniform heat fluff. Test fluids are made to be homogeneous suspensions, in which neutrally buoyant microparticles ($d=25{\sim}300{\mu}m$) are uniformly dispersed. The present measurements show strong shear-rate dependent thermal conductivities for the suspensions, which are higher than those at zero shear rate. The shear rate dependent thermal conductivity increases with the particle size and volume concentration.4 new model for shear rate-dependent thermal conductivity of microparticle suspensions is proposed; the correlation covers from zero shear rate value to asymptotic plateau value at moderately high shear rates.

Sizing of Spray Particles Using Image Processing Technique

  • Lee, Sang-Yong;Kim, Yu-Dong
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.879-894
    • /
    • 2004
  • The image processing technique is simple and, in principle, can handle particles with various shapes since it is based on direct visualization. Moreover, a wide measurement area can be covered with appropriate optical arrangement. In the present paper, various techniques of image processing for sizing and counting particles are reviewed and recent developments are introduced. Two major subjects are discussed in detail: identification of particles (i.e., boundary detection and pattern recognition) and determination of in-focus criteria. Finally, an overall procedure for image processing of spray particles is suggested.

CHARACTERISTICS OF RESIDUAL CARBON DERIVED FROM THE COMBUSTION OF VACUUM RESIDUE IN A TEST FURNACE

  • Park, Ho-Young;Seo, Sang-Il
    • Environmental Engineering Research
    • /
    • v.12 no.3
    • /
    • pp.109-117
    • /
    • 2007
  • The characteristics of carbonaceous particles collected from the combustion of Vacuum Residue (VR) in a test furnace have been investigated. The physical and chemical characterization includes particle size, scanning electron microscopy of the surface structure, measurement of porosity, surface area and density, EDX/XRD analyses and measurement of chemical composition. The studies show that the carbonaceous VR particles are very porous and spheroidal, and have many blow-holes on the surface. The particles become smaller and more sponge-like as the reaction proceeds. The present porosity of VR particles is similar to that of cenospheres from the combustion of heavy oil, and the majority of pores are distributed in macro-pores above $0.03\;{\mu}m$ in diameter. Measurements of pore distribution and surface area showed that the macro-pores contributed most to total pore volume, whereas the micro-pores contributed to total surface area.

Measurement of Sizes and Velocities of Spray Droplets by Image Processing Method (영상 처리에 의한 분무 액적의 크기 및 속도 추출)

  • Choo, Y.J.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.7 no.4
    • /
    • pp.23-31
    • /
    • 2002
  • In this study, the sizes and velocities of droplets in sprays were measured by image processing method from digital images of local region of sprays. The morphological method based on the Euclidean distance transform, Watershed separation, and perimeter image was adopted for the recognition and separation of overlapped particles. The match probability method was used for the particle tracking and pairing. The measurement results show that the present method may be reliable for the analysis of the motion and distribution of droplets produced by spray and atomization devices.

  • PDF

Studies on the Sintering of the Cordierite Glass-ceramics (코디어라이트계 결정화 유리의 소결에 관한 연구)

  • 박용완;현부성
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.10
    • /
    • pp.779-784
    • /
    • 1992
  • In producing cordierite glass-ceramics by sintering, following experiments were conducted in order to determine the optimum heat-treatment schedule for high-crystallinity and dense sintered body. The glass composition of 11.67MgO-29.46Al2O3-52.88SiO2-5P2O5-1B2O3 (wt%) was selected on the basis of the early experiment. The 3-step heat treatment schedule was determined by the results of DTA, Dilatometric measurement and high-temperature XRD, where the particle-size-controlled glass powder was used. The degree of densification and the crystallinity were evaluated by the measurement of the bulk density and X-ray scattering intensity. The specimen fired with the optimum conditions showed ${\alpha}$-cordierite phase, relative density ∼98%, crystallinity ∼92%, thermal expansion coefficient ∼30${\times}$10-7/$^{\circ}C$, dielectric constant ∼5.5 and resistivity ∼1.0${\times}$1012 {{{{ OMEGA }}cm, respectively.

  • PDF

Passive and Active Detection of Conducting Nanoparticles by Nanogaps

  • Lee, Cho Yeon;Park, Jimin;Park, Jong Mo;Kang, Aeyeon;Yun, Wan Soo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.268.1-268.1
    • /
    • 2013
  • Immobilization of conducting nanoparticles on a nanogap comprising two electrodes spaced at a distance comparable to the particle size can be used as a simple and sensitive method of detecting the particles. In this work, we have examined the performance of the nanogap devices in the measurement of metallic nanoparticles, particularly gold nanoparticles (Au NPs). Detection of pM-level Au NPs in an aqueous suspension was quite straightforward irrespective of the existence of non-conducting materials. Speed of detection or the time necessary for the completion of the measurement, however, was strongly dependent upon the immobilization process. Active trapping process was found to be much more efficient and also effective in the detection of nanoparticles than its passive counterpart.

  • PDF

A Study on the Spray Characteristics of Small LRE Injector through PIV and PDA Measurements (PIV 및 PDA 계측에 의한 소형 액체로켓엔진 인젝터의 분무특성 연구)

  • Kim, Jin-Seok;Jung, Hun;Kim, Jeong-Soo;Park, Jeong;Kim, Sung-Cho;Choi, Jong-Wook;Jang, Ki-Won
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.63-67
    • /
    • 2006
  • Spray characteristics of an injector employed in mono-propellant hydrazine thrusters were investigated by PIV(particle image velocimetry) and PDA(phase Doppler anemometry) techniques. The instantaneous plane images captured by PIV measurement were examined in order to judge the pass-fail criteria of spray injection performance according to the specific pressure supplied. PDA technique was also applied to measure the velocity and droplet size of spray which were not obtainable by PIV measurement. The objective of this experimental study is the evaluation of the injector performance which may be utilized for the design of brand-new injector through the clear understanding of spray characteristics.

  • PDF

A Study on the Distribution of Friction Heat generated by CMP Process (CMP 공정에서 발생하는 연마온도 분포에 관한 연구)

  • 김형재;권대희;정해도;이용숙;신영재
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.42-49
    • /
    • 2003
  • In this paper, we provide the results of polishing temperature distribution by way of infrared ray measurement system as well as polishing resistance, which can be interpreted as tribological aspects of CMP, using force measurement system. The results include the trend of polishing temperature, its distribution profile and temperature change during polishing. The results indicate that temperature affects greatly to the removal rate. Polishing temperature increases gradually and reaches steady state temperature and the period of temperature change occurs first tens of seconds. Furthermore, the friction force also varies as the same pattern with polishing temperature from high friction to low. These results suggest that the first period of the whole polishing time greatly affects the nonuniformity of removal rate.

Manufacture of paste opaque porcelains using glycols as a solvent and evaluation of their physical properties (글리콜을 용매로 제조한 연고형 불투명 도재의 물성)

  • Kim, Sa-Hak
    • Journal of Technologic Dentistry
    • /
    • v.25 no.1
    • /
    • pp.41-62
    • /
    • 2003
  • In this research, we manufactured the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent, and compared the composition of solvents, the coefficient of thermal expansion, the particle size distribution, the viscosity and bonding strength to metal, and the tone with those of the commercial products(Duceram Plus, Duceram GmbH; VMK 95, Vita Co.; Noritake EX-3, Noritake Co.)used in the clinical field. The results of the research were as follows: 1. The result of solvent analysis indicated that the solvents included in the paste opaque porcelains of the control group were mainly composed of Glycols. 2. From the Coefficient of thermal expansion measurement, we drew out the following results; testing group: $14.0\times10^{-6}/^{\circ}C$, Duceram Plus: $13.9\times10^{-6}/^{\circ}C$, VMK 95: $14.3\times10^{-6}/^{\circ}C$, and Noritake EX-3: $13.3\times10^{-6}/^{\circ}C$. 3. Seen from the result of particle size distribution measurement, the experimental group was similar to the control group in 1$\mu m$ below, but the experimental group marked the highest distribution of 61% in the case of between 1$\mu m$ and 5$\mu m$. Between 5$\mu m$ and 10$\mu m$, they showed relatively similar distribution, and Noritake EX-3 was turned out the highest distribution of 29% in 10$\mu m$ above. 4. From the result of viscosity measurement, Duceram plus showed the highest viscosity throughout all the measurements followed by Noritake Ex-3, experimental group and VMK 95 in decreasing order. 5. The result of bonding strength measurement was EX 35.53 $\beta\acute{A}$, DU 40.88 $\beta\acute{A}$, VM 39.43 $\beta\acute{A}$, and NO 35.39 $\beta\acute{A}$, and no significant difference was found between the experimental group and the control groups(P>0.05). 6. The measurement of the tone indicated that the $L^*$ value of the experimental group was 86.89 0.63 in average, which is higher than the control group in its brightness. In the case of the $a^*$ value, Duceram Plus, VMK 95 and EX-3 showed positive value, whereas the testing group was turned out negative value. In $b^*$ value, Duceram Plus proved the highest. From the results of this research, the paste opaque porcelains using Propylene Glycol (PG) and Buthylene Glycol (BG) as a solvent did not make differences from the commercial products that are actually used in the clinical fields. Therefore, it is possible to utilize Propylene Glycol (PG) and Buthylene Glycol (BG) for the paste opaque porcelains of P.F.M crown. It is also recommended that further researches concerning the compositions and forms of powder, the types of organic solvent components and the ratio of mixture proceeded in order to improve the level of productivity in the future.

  • PDF