• 제목/요약/키워드: Particle mass

검색결과 953건 처리시간 0.028초

알루미늄 입자 크기에 따른 파라핀 혼합연료의 연소 특성 연구 (A Study on Combustion Characteristics of Paraffin Blended Fuel on Aluminum Particle Size)

  • 고수한;한승주;류성훈;김진곤;문희장;김준형;고승원
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.791-796
    • /
    • 2017
  • 본 연구에서는 알루미늄 입자 크기에 따른 파라핀 혼합연료의 연소 특성에 관한 실험을 수행하였다. 평균 입도 100 nm 및 $8{\mu}m$ 크기의 알루미늄 입자와 Sasol사의 마이크로크리스탈린 파라핀 왁스(Sasol 0907)를 이용하여 연소실험을 수행하였고 순수 파라핀과 알루미늄 입자 5 wt%를 첨가한 파라핀 혼합연료의 후퇴율과 압력선도, 특성배기속도 등을 비교하였다. 마이크로 입자의 첨가는 산화제 유속이 증가할수록 후퇴율을 향상시켰으나 나노 입자의 첨가는 후퇴율이 감소하는 경향을 보였다.

  • PDF

광학적 입자계수기를 이용한 2004년 황사기간 인천지역 에어로졸 특성 (Characteristics of Incheon Aerosol during Asian Dust Period in 2004 using Optical Particle Counter (OPC))

  • 정창훈;조용성;이종태
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.565-575
    • /
    • 2005
  • The characteristics for the aerosol number distribution was studied during spring, 2004 in Incheon. Optical Particle Counter (OPC, HIAC/ROYCO 5230) was used in order to measure the number concentration of aerosol in the range of $0.3\~25{\mu}m.$. The obtained results were compared with $PM_{2.5}\;and\;PM_{10}$ data during Asian dust events. The results show that the size resolved aerosol number concentration from OPC measurement has a similar tendency with $PM_{10}\;and\;PM_{2.5}$ mass concentration. During Asian dust periods, the number concentrations in large particle $(CH5\~CH8)$ increase more than small particles which diameter is less than $2.23{\mu}m(CH5)$ and the same results were shown when $PM_{10}$ was compared with $PM_{2.5}$ data compared with non-dust days, Consequently, this study shows that size resolved aerosol number concentration from OPC measurement can be used as a useful tool in comparison of mass concentration data.

진공공간 내 나노급 오염입자의 실시간 진단시스템 개발 (Development of real-time nanoscale contaminant particle characteristics diagnosis system in vacuum condition)

  • 강상우;김태성
    • 진공이야기
    • /
    • 제2권3호
    • /
    • pp.11-15
    • /
    • 2015
  • Particle characteristics diagnosis system (PCDS) was developed to measure submicron particle characteristics by modulation of particle beam mass spectrometry (PBMS) with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS). It is possible to measure the particle size distribution in real-time, and the shape, composition can be measured in sequence keeping vacuum condition. Apparatus was calibrated by measuring the size classified NaCl particle which generated at atmospheric pressure. After the calibration, particles were sampled from the exhaust line of plasma enhanced chemical vapor deposition (PECVD) process and measured. Result confirms that PCDS is capable for analyzing particles in vacuum condition.

후처리장치 부착에 따른 대형디젤엔진의 입자 배출특성 (Particle Emission Characteristics of Heavy-duty Diesel Engine using Aftertreatment Systems)

  • 권상일;박용희
    • 한국분무공학회지
    • /
    • 제17권3호
    • /
    • pp.146-151
    • /
    • 2012
  • This study was primarily focused on the experimental comparison of the particle emission characteristics for heavy duty engine. PM and particle number from various heavy duty engines and DPF type were analyzed with a golden particle measurement system recommended by the Particle Measurement Program. And the repeatability and reproducibility between test mode was analyzed. This study was conducted for the experimental comparison on particulate emission characteristics between the European and World-Harmonized test cycles for a heavy-duty diesel engine. To verify the particulate mass and particle number concentrations from various operating modes, ETC/ESC and WHTC/WHSC, both of which will be enacted in Euro VI emission legislation, were evaluated. Real-time particle formation of the transient cycles ETC and WHTC were strongly correlated with engine operating conditions and after-treatment device temperature. A higher particle number concentration during the ESC mode was ascribed to passive DPF regeneration and the thermal release of low volatile particles at high exhaust temperature conditions.

우리나라 일부지역의 입자상 물질 농도에 대한 연구 (A study of particulate matters in Korea)

  • 손부순;공미연;박종안;양원호;김종오
    • 환경위생공학
    • /
    • 제18권4호
    • /
    • pp.24-35
    • /
    • 2003
  • Recent epidemiologic studies revealed that the concentration of air pollutants and fine particulated matter have some effects on health status and are associated with increased mortality and morbidity. The purpose of this study was to characterize background mass concentration of fine particle (PM2.5) and metallic composition from September 2001 to August 2002 in comparison with a medium city, Asan and metropolitan city, Seoul. Conclusively, proper management for fine particles was required in a medium city, Asan, considering the concentrations of metallic elements in fine particles in Asan were relatively higher than those in Seoul. The results were as followed. 1. Average mass concentrations of fine particles in Asan and Seoul were 37.70(${\pm}18.41{\;}{\mu}g/\textrm{m}^3$) and 5.83(${\pm}38.50$) ${\mu}g/\textrm{m}^3$, respectively. When the weather conditions were classified as normal and yellow-sand, measured average mass concentrations of fine particles in yellow-sand weather condition was significantly higher than those of normal weather condition in both cities (p<0.05). 2. Depending on seasons, measured average mass concentrations of fine particles in Asan and Seoul in spring were 47.76(${\pm}19.07$) ${\mu}g/\textrm{m}^3$m and 61.53 (${\pm}4.37$) ${\mu}g/\textrm{m}^3$, respectively. In summer, the average mass concentrations of fine particles in Asan and Seoul were 29.44(${\pm}9.85$) ${\mu}g/\textrm{m}^3$ and 25.42(${\pm}8.10$) ${\mu}g/\textrm{m}^3$, respectively. Especially, the concentration was the highest in spring and the lowest in summer among four seasons. 3. Average concentrations of manganese(Mn), iron(Fe), chromium(Cr), cadmium(Cd), lead(Pb) and silicon(Si) in fine particles in Asan were significantly higher in Seoul (p<0.05). Average concentration of Si in fine particle in Asan was statistically higher than that of Seoul during yellow -sand condition (p<0.05). 4. Considering the characterization of four seasons, average Pb concentration of fine particle in Asan is significantly higher than that of Seoul in spring(p<0.01). In summer, average Mn and Cr concentrations of fine particle in Asan is higher than those of Seoul (p<0.05). Average Mn, Fe. Cr and Si concentrations in fall (p<0.05), and average Mn, Fe, Cr, Pb, and Si concentrations in winter (p<0.05) in Asan were higher than those of Seoul, respectively. 5. Mass concentrations of each Mn, Fe, Cd and Si in fine particles were significantly correlated with both cities. In normal weather condition, Mn, Cu and Si concentrations are statistically significant in Asan, while Mn, Fe, Cu and Si concentrations are statistically significant in Seoul. Mn, Fe and Si concentrations in both cities were statistically significant during yellow-sand weather.

미세먼지 간이측정기 현장 검사용 시험 입자 발생기 개발 및 성능 평가 (Development and performance evaluation of a test particle generator for a field inspection equipment of PM-2.5 sensors)

  • 정혁;박진수
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.61-68
    • /
    • 2022
  • In this study, a fluidized bed particle generator was developed to generate an aerosol without supply of compressed air and to increase portability. It was assumed that the mixing ratio of the test particles and beads, the input amount, and the air flow rate supplied to the generator would have effect on the aerosol generation characteristics. The product of these three parameters was set as a characteristic parameter and particle generation characteristics according to the change of the characteristic parameter were observed. As a result, it was confirmed that the input amount of test particles and beads was not suitable as a characteristic parameter and a characteristic parameter expressed as a product of the mass mixing ratio and the air flowrate was newly defined. When the new characteristic parameter is applied, it can be confirmed that the total amount of particles generated from the particle generator is a function of the characteristic parameter. As a result of measuring the amount of particle generation by adjusting the characteristic parameter, it was confirmed that the performance required for the test particle generator for the field inspection equipment of PM-2.5 sensors could be satisfied.

공기조화기 장착용 축상유입식 싸이클론의 입자제거효율에 대한 실험적 연구 (Experimental Study on Particle Collection Efficiency of Axial-flow Cyclone in Air Handling Unit)

  • 김세영;권순박;박덕신;조영민;김진호;김명준;김태성
    • 한국대기환경학회지
    • /
    • 제27권3호
    • /
    • pp.272-280
    • /
    • 2011
  • A novel particle removal system for air handling unit (AHU) of subway station was evaluated experimentally. The novel system was designed in order to minimize the maintenance cost by applying axial-flow cyclones. The system consists of multiple cyclone units and dust trap. Based on our previous numerical study, it was found to be effective for removal $1\sim10{\mu}m$ sized dust particles. In this study, we manufactured the mock-up model and evaluated the model experimentally. Liquid and solid test particles were generated for evaluating collection efficiency of the system and the pressure drop was monitored. The collection efficiency was varied from 41.2% to 85.9% with increasing the sizes of particle from 1 to $6.5{\mu}m$ by particle count ratio of inlet and outlet. The pressure drop was maintained constant less than $20mmH_2O$. In addition, the collection efficiency was estimated by total mass for solid test particles. It was found that the collection efficiency was 65.7% by particle mass ratio of inlet and outlet. It shows that present system can replace current pre-filters used in subway HVAC system for removing particulate matters with minimal operational cost.

이젝터-다공튜브 희석 샘플링과 ELPI를 이용한 석탄화력발전소 배출 미세먼지의 입자 크기에 따른 성분 분석 (Elemental components analysis according to the size of fine particles emitted from a coal-fired power plant using an ejector-porous tube dilution sampling and ELPI)

  • 신동호;박대훈;조윤희;김영훈;홍기정;이건희;한방우;황정호
    • 한국입자에어로졸학회지
    • /
    • 제18권3호
    • /
    • pp.69-77
    • /
    • 2022
  • In order to understand the characteristics of fine particles emitted from coal-fired power plant stacks, it is important to analyze the size distribution and components of particles. In this study, particle size distributions were measured using the ejector-porous tube dilution device and an ELPI system at a stack in a coal-fired power plant. Main elemental components of particles in each size interval were also identified through TEM-EDS analysis for the particles collected in each ELPI stage. Particle size distributions based on number and mass were analyzed with component distributions from 0.006 to 10 ㎛. The highest number concentration was about 0.01 ㎛. The main component of the particles consisted of sulfur, which indicated that sulfate aerosols were generated by gas-to-particle conversion of SO2. In a mass size distribution, a mono-modal distribution with a mode diameter of about 2 ㎛ was shown. For the components of PM1.0 (particles less than 1 ㎛), the abundance order was F > Mg > S > Ca, and however, for the components of PM10 (particles less than 10 ㎛), it was in the order of Fe > S > Ca > Mg. The elemental components by particle size were confirmed.

합성암반체 접근법에 대한 고찰 (Review of the Synthetic Rock Mass Approach)

  • 박철환;신중호;박의섭
    • 터널과지하공간
    • /
    • 제17권6호
    • /
    • pp.438-447
    • /
    • 2007
  • 본 기술보고서는 Lisbon에서 개최된 2007 ISRM Congress에서 발표된 논문을 소개한 것이다. 이는 SRM(합성암반체)에 관한 연구결과이며, 이의 중요성과 향후 잠재력을 강조하고 있는 Fairhurst 교수가 직접 발표한 논문이다. 절리 암반의 특성을 규명하는 SRM 접근법은 현존하는 경험적 접근법이나 절리 암반의 거동에 대한 현재의 이해정도와 관련지어 재검토된다. 이 재검토 논문에서 절리 암반의 역학적 거동에 영향을 미치는 주요 요소들이 어떻게 고려되는가를 기술하며, 또 SRM 접근법이 상당히 발전되어 현장에 적용된 사례를 보여준다. PFC-3D에서 BP 모델링과 DFN 모사법 등의 두개의 잘 정립된 방법에 기초를 두고 있는 이 기법은 새로운 미끄러지는 절리모델을 사용한다. 이 모델은 모든 응력경로에 의하여 힘을 받고 있는 수천개의 기존 절리를 포함하는 대규모 암반체를 모사할 수 있게 하는 것이다. 암반의 강도 및 취성도, 완전 순응 행렬의 전개, 그리고 초기의 파쇄 등이 SRM 시험에서 얻어지는 결과이다.

흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경 (Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study)

  • 정재열;이기남
    • 동의생리병리학회지
    • /
    • 제17권5호
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.