• Title/Summary/Keyword: Particle image analyzer

Search Result 34, Processing Time 0.02 seconds

A study of the effects on the composition of the electrodeposited Ni-TiO2 composite with the ultrasonic treatment (전기도금법으로 만든 니켈-티타니아 복합체에서 초음파 처리가 도금층에 미치는 영향 연구)

  • Kim, Myong-Jin;Kim, Joung Soo;Kim, Dong Jin;Kim, Hong Pyo;Hwang, Seong Sik
    • Corrosion Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.185-190
    • /
    • 2013
  • In the present study, $Ni-TiO_2$ composite coatings were electrodeposited in a sulfamate bath containing $TiO_2$ particles. The influence of the ultrasonic treatment on the co-deposition of $TiO_2$ particles in the coating and the hardness of the electrodeposited $Ni-TiO_2$ composite has been investigated. Three different ultrasonic treatments (pretreatment before the electrodeposition (pre-UT), pretreatment + applied during the electrodeposition (UT), and the electrodeposition without the ultrasonic treatment (w/o UT)) were performed. The $Ni-TiO_2$ composite coatings are characterized using scanning electron microscopy (SEM), image analyzer, and hardness tester. Comparison of results indicates that the volume fraction is more important factor than the agglomerated particle size in terms of the strength improvement, and the strength of the electrodeposited $Ni-TiO_2$ composite coatings is enhanced with pre-UT condition.

Preparation and Characterization of Biodegradable Poly($\varepsilon$-caprolactone) Microcapsules Containing Erythromycin by Emulsion Solvent Evaporation Technique (액중건조법을 이용한 항생제를 함유한 생분해성 폴리카프로락톤 마이크로캡슐의 제조 및 특성)

  • 박수진;김승학;이재락;이해방;홍성권
    • Polymer(Korea)
    • /
    • v.26 no.3
    • /
    • pp.326-334
    • /
    • 2002
  • The purpose of this work was the producing of a biodegradable poly($\varepsilon$-caprolactone) (PCL) microcapsule and the analyzing of form and features for the manufacturing conditions which could be observed in a prospective drug delivery systems (DDS) through drug release. The effects of different stirring rates, stirring times and concentrations of emulsifier for the diameter and form of the microcapsules were observed using image analyzer (IA) and scanning electron microscopy (SEM). As a result, the microcapsules were made in wrinkle and spherical forms with a mean particle size of 40~300$\pm$20 $mu extrm{m}$. PCL microcapsules containing drugs were confirmed using FT-IR spectra. The role of interfacial adhesion between PCL and drug was determined by contact angle measurements. The drug release test of PCL microcapsules was characterized by UV/vis. spectra. It was found that the drug release rate of the microcapsules prepared with high concentration emulsifier was significantly fast.

Formation of the multiamellar vesicles of AHAsomes and effect of removal on the horny layer (AHAsomes의 multilamellar vesicles형성과 각질제거 효과)

  • 김인영;서봉석
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.21 no.2
    • /
    • pp.1-21
    • /
    • 1995
  • In this context, it should be mentioned that multilamellar vesicles can be prepared with the main compounds of the intercellular lipids, ceramides, cholesterol, cholesteryl ester, squalane, lecithin, wax ester by effect of the wetting. We investigated properties formation of MLV with use of the AHAsomes and Microfluidizer. The multilamellar vesicles are formed merely adding polyol and water phase, followed with the microfluidizer. Formation of a practically pure AHAsomes system, containing the active ingredients directly incorporated without need for preservatives. There were very good encapsulated properties of the active ingredients whether hydrophilic(malic acid, tartaric acid, lactic acid, allantoin, urea) and hydrophobic(vitamin-I acetate, vitamin-A palmitate). Optimum condition (ormatiom of MLV was passed three times in the microfluidizer, particle size of the vesicles should be within range 50-523nm (mean=163.5nm). As application, It was compared that horny layer of the sole of foots removal with the general OM emulsion and the AHAsomes cream. There was used for three months, those got recovery wrinkles about 151.8% and elasticity three times more the AHAsomes than O/W emulsions, It was confirmed with the Image Analyzer and the Cutometer.

  • PDF

A Study on The Filtration Characteristics of Magnetic Fibrous Polymeric Filter with Packing Density Profile as a New Oil Filter (윤활시스템용 오일필터로서 충전밀도 변화에 따른 자성폴리머 필터의 여과특성 연구)

  • 최기영;안병길;최웅수;권숙인;권오관
    • Tribology and Lubricants
    • /
    • v.11 no.2
    • /
    • pp.8-14
    • /
    • 1995
  • The filtration of the magnetic fibrous polymeric filter with packing density profile made of a self-bonded, nonwoven structure comprising a thermoplastic polymer and a magnetic substance was investigated using an oil filter tester, a particle quantifier and an image analyzer system. The magnetic fibrous polymeric filter showed excellent filtration efficiency compared with conventional paper filter. From the experimental results, It is deduced that the filtration mechanism of conventional paper filter is only the function of physical porosity by surface filteration. On the other hand, the newly magnetic fibrous polymeric filter is designed with a new concept in filtration mechanism. That is, it has a dual function of depth and magnetic filters by physical porosity and magnetic attraction. The newly magnetic fibrous polymeric filter has been shown to be a highly effective oil filter for lubrication systems.

Effects of Scratching on the Surface of Protein Chip Plates (단백질 칩 기판의 표면 스크래칭 효과)

  • Hyun, June-Won;Hwang, Jeong-Il
    • Journal of the Korean institute of surface engineering
    • /
    • v.40 no.2
    • /
    • pp.98-102
    • /
    • 2007
  • [ $NiCl_2$ ] and poly-L-lysine coated protein chip plates have been fabricated using a spin coating system. Water has been used as solvent and scratching effects on glass slides and ITO have been investigated. We also observed the surface properties of $NiCl_2$ and poly-L-lysine coated slides by using PSA(Particle size analyzer) and AFM(Atomic force microscope). The AFM results imply that the surface patterns created in the spin coating system determine the protein adsorption. Adsorption of histidine-tagged KRS proteins immobilized on glass slides and ITO was analyzed using a BAS image system. The results suggest that the scratching effect was increased ability of protein adsorption.

The Spray Characterization Using Planar Imaging Technique (평면 이미지 기법을 이용한 분무 특성 해석)

  • Lee, Kyung-Jin;Jung, Ki-Hoon;Yoon, Young-Bin;Jeong, Kyung-Seok;Jeung, In-Seuck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.1
    • /
    • pp.93-101
    • /
    • 2000
  • The characteristics of spray nozzle have been quantified with the measurement of fluorescence and Mie scattering images. To correct the attenuation of the incident light sheet, a sequential double-pass light sheet system and the geometrical averaging of two images was implemented. Quantitative mass flux distribution of spray was obtained from fluorescence image. 3-D image is reconstructed using 2-D radial images. Sauter mean diameter (SMD) distribution was determined using the ratio of fluorescence signal intensity and Mie scattering signal intensity and the values were quantified with PDP A data. The measurement of mass flux and SMD using planar imaging technique agee with PDP A data fairly well in the low density region. However, in dense region, there are significant errors caused by secondary scattering. It was found that the planar imaging technique provides many advantages over the point measurement technique, such as PDP A, and can be implemented for quantitative measurement, especially in low density region.

Preparation and Characteristic of Size Controlled Platy Silver by Polyol Process with $PdCl_2$ ($PdCl_2$ 첨가 폴리올공정(工程)을 이용(利用)한 판상 은(銀) 분말(粉末) 제조(製造) 및 특성(特性))

  • Shin, Gi-Wung;Ahn, Jong-Gwan;Kim, Dong-Jin;Cho, Sung-Wook;Ahn, Jea-Woo
    • Resources Recycling
    • /
    • v.19 no.5
    • /
    • pp.58-67
    • /
    • 2010
  • Platy silver powders with varied size and thickness were prepared by polyol process with $PdCl_2$ in ethylene glycol and characterized its properties and investigated the effects of reaction time, $NH_4OH$, PVP(poly-vinylpyrrolidone) and $PdCl_2$. The characteristics of the products were verified by scanning electron microscopy(SEM), high resolution transmitted electron microscopy(HR-TEM), X-ray diffraction(XRD) and particle size analyzer(PSA) and image analyzer. Platy silver powder was prepared about $5.5\;{\mu}m$ of size and $0.2\;{\mu}m$ at 120minute. It was found that the size of powders increased by the increasing of $NH_4OH$ and $PdCl_2$ concentrations, and the thickness of powders was decreased by increasing of PVP concentration.

STUDY ON STABILITY, EFFICACY, AND EFFECT OF A CREAM CONTAINING 5% OF RETINYL PALMITATE

  • Ji, Hong-Keun;Jeon, Young-Hwan
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.23 no.3
    • /
    • pp.48-74
    • /
    • 1997
  • Retinlyl Palmitate, the skin normalizerm is useful to promote greater skin elasticity, to diminish lipid peroxidation and skin roughness following UV exposure, and promote a youthfulgeneral skin appearance. In manufacturing creams, Retinyl Palmitate, which is a derivative of retinol, is used since reionol is easily oxidized by heat and light. However, only a small mount of retinol, is used since using a large amount of it may be harmful to its stability. In this study, thermal stability and UV stability of W/O-, W/S-, O/W-, and MLV-type creams containing 5% of retinyl palmitate and 10% of tocopheryl acetate are measured by Chroma Meters, and the content of RP is quantitatively analyzed by HPLC at 25 $^{\circ}C$ and 45 $^{\circ}C$. Also, how RP has been changed by heat, light, etc. is measured by HPLC, and toxicity of the changed substance is studied. Particle size of each type of the cream if measured, cellular renewal is measured by using DHP and Chroma Meters in order to study their efficacy and effect, moisture content is measured by using Corneometer and Tewameter, and how much wrinkles are improved is studied by using Image Analyzer. Development of MLV-type cream containing 5% of RP and 10% of TA, and satisfying conditions for better creams has been successful.

  • PDF

Evaluation on the Usefulness of Alternative Radiopharmaceutical by Particle size in Sentinel Lymphoscintigraphy (감시림프절 검사 시 입자크기에 따른 대체 방사성의약품의 유용성평가)

  • Jo, Gwang Mo;Jeong, Yeong Hwan;Choi, Do Cheol;Shin, Ju Cheol
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.2
    • /
    • pp.36-41
    • /
    • 2016
  • Purpose Sentinel lymphoscintigraphy (SLS) was using only $^{99m}Tc-phytate$. If the supply is interrupted temporarily, there is no alternative radiopharmaceuticals. The aim of this study measure the particle size of radiopharmaceuticals and look for radiopharmaceuticals which can be substituted for $^{99m}Tc-phytate$. Materials and Methods The particle size of radiopharmaceuticals were analyzed by a nano-particle analyzer. This study were selected known radiopharmaceuticals to be useful particle size for SLS. We were divided into control and experimental groups using $^{99m}Tc-DPD$, $^{99m}Tc-MAG3$, $^{99m}Tc-DMSA$ with $^{99m}Tc-phytate$. For in-vivo experiment, radiopharmaceuticals were injected intradermally at both foot to perform lymphoscintigraphy. Imaging was acquired to dynamic and delayed static image and observe the inguinal lymph nodes with the naked eye. Results Particle size was measured respectively Phytate 105~255 nm (81.9%), MAG3 91~255 nm (98.7%), DPD 105~342 nm (77.3%), DMSA 164~ 342 nm (99.2%), MAA 1281~2305 nm (90.6%), DTPA 342~1106 nm (79.4%), and HDP 295~955 nm (94%). In-vivo delayed static image, inguinal lymph nodes of all experiment groups and two control groups are visible to naked eye. however, $^{99m}Tc-MAG3$ of control groups is not visible to naked eye. Conclusion We were analyzed to the particle size of the radiopharmaceuticals that are used in in-vivo. Consequently, $^{99m}Tc-DPD$, $^{99m}Tc-DMSA $are possible in an alternative radiopharmaceuticals of emergency.

  • PDF

Lamellar-bio nano-hybrid; The Study for Stability of Catechin (Green Tea: EGCG) Using 3-Dimensional Liposome (라멜라-바이오 나노하이브리드: 3 Dimension-liposome을 이용한 카테킨(EGCG)에 안정화에 대한 연구)

  • Hong Geun, Ji;Jung Sik, Choi;Hee Suk, Kwon;Sung Rack, Cho;Byoung Kee, Jo
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.30 no.2
    • /
    • pp.201-205
    • /
    • 2004
  • In these several years, as many people have been attracted by the functional cosmetics, there are a lot of study to enhance the stability of active ingredients for light, heat, oxygen, etc. in the academic and industrial field. Especially, catechin is well known as strong anti-oxidant, anti-inflammatory and reducing agent for oxidative stress but it is very unstable for light, heat, oxygen. etc. In this study, the stability and skin penetration of catechin are improved by 3-dimensional method. As I-dimension, porous silica is prepared using sol-gel method, and then catechin is adsorbed in pores of silica. As 2-dimension, solid lipid nanoparticles (SLN) are obtained using non-phospholipid vesicles. Finally 3-dimension is completion through lamellar phase self-organization that combines SLN catechin with skin lipid matrix. We used laser light scattering system, cyro-SEM, chromameter, HPLC and image analyzer to analyze our 3-dimentional systems. According to chromameter date, the color stability of 3-dimensional catechin is enhanced by 5-10 times compared with general liposome systems. We also confirmed through HPLC analysis that 3-dimensional catechin is more long lasting. The effect of skin penetration and wrinkle reduction are improved, too.