• Title/Summary/Keyword: Particle image analyzer

Search Result 34, Processing Time 0.025 seconds

Internal Structure and Velocity Field of the Impinging Diesel Spray on the Wall (디젤 충돌 분무의 발달 과정 및 내부 유동 특성)

  • Chon, M.S.;Suh, S.K.;Park, S.W.;Lee, C.S.
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.1-8
    • /
    • 2005
  • The purpose of this study is to investigate the internal structure of the impinged diesel spray at various experimental conditions. To examine the effect of various factors on the development of a diesel spray impinging on the wall, experiments were conducted at the various Injection pressures, wall distances from the nozzle tip and angles of wall inclination. The PIV system consists of a double pulsed Nd:YAG laser was utilized to analyze the internal flow structure of impinged diesel sprays. The velocity fields from the PIV system were compared with the results measured by the phase Doppler particle analyzer(PDPA)system. The results show that internal flow pattern of the impinged spray was similar with the results from the PDPA system. The radial velocity of the impinged spray was increased with the increase in the injection pressure and near the nozzle-wall distance. The generation of vortex was also promoted with the Increase in angles of wall inclination.

  • PDF

The Preparation of Polyurethane Microcapsule and Its Breaking Behavior (폴리우레탄계 마이크로캡슐의 제조 및 그의 파괴 거동)

  • 박형인;김애경;이웅의;최창남
    • Textile Coloration and Finishing
    • /
    • v.10 no.2
    • /
    • pp.37-44
    • /
    • 1998
  • In this study, the polyurethane microcapsules containing disperse dye were prepared by in-situ polymerization method using hexamethylene diisocyanate (HDI, aliphatic type) and m-xylene diisocyanate(XDI, aromatic type) with ethylene glycol (EG) And the size, shape, particle size distribution, and breaking behavior of microcapsules prepared were investigated. The size and shape of microcapsule were observed by scanning electron microscope (SEM) . The particle size distribution was analyzed by image analyzer. The breaking behavior of microcapsule was checked by measuring the optical density of solution that the disperse dye was dissolved after the microcapsule was broken by constant pressure. The particle size was inversely proportional to the stirring speed, and the size of microcapsule prepared from HDI and EG was smaller than that of microcapsule prepared from XDI and EG. Aliphatic type microcapsule was broken easily, compared with aromatic type one. It was considered due to the difference of reactivity between HDI and XDI. And the microcapsule prepared by stirring strongly was broken easily.

  • PDF

Characterization of Microscale Objects based on the Diffraction Pattern Analysis (회절무늬를 이용한 미세물체의 특성 측정)

  • 강기호;전형욱;손정영;오명환
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 1991
  • This paper describes the theoretical analysis of a diffraction pattern analyzer for the characterization of microscale object fields and a method for obtaining size and size distribution from the measured diffraction pattern of the object fields. For the experimental verification, a typical optical Fourier transform system was set up and calibrated with 2 5$\mu \textrm m$ and 50$\mu \textrm m$ pinholes. The system responses to distilled water droplets, alcohol, glycerin and silicon oil were imaged with vidicon, and the image was processed to determine the size distribution of each liquid particle field. The energy distribution function which is defined as the total intensity of a circular ring in the diffraction pattern was used to determine the dominant particle size of each liquid particle field.

  • PDF

Droplet size measurement using image processing method (이미지프로세싱 기법을 이용한 액적크기 측정)

  • Lim Byoungjik;Jung Kihoon;Khil Taeock;Yoon Youngbin
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.25-31
    • /
    • 2004
  • Droplet size is one of the most important parameter which controls the performance of the combustion system using liquid fuel or oxidizer. Droplet formation and its size are mainly affected by the injection velocity and ambient gas density. Recently, droplet size measurement was conducted by PDPA or Malvern particle analyzer using laser light. But at this paper image processing method was developed to measure droplet size. And its validation was investigated with reticle.

  • PDF

Effects of Particle Shapes on Unipolar Diffusion Charging of Non-Spherical Particles (비구형 입자의 형상에 따른 단극 확산 하전 특성)

  • Oh, Hyun-Cheol;Park, Hyung-Ho;Kim, Sang-Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.501-509
    • /
    • 2004
  • Unipolar diffusion charging of non-spherical particles was investigated for various particle shapes. We researched with TiO$_2$agglomerates produced by the thermal decomposition of titanium tetraisopropoxide (TTIP) vapor. TTIP was converted into TiO$_2$, in the furnace reactor and was subsequently introduced into the sintering furnace. Increasing the temperature in the sintering furnace, aggregates were restructured into higher fractal dimensions. The aggregates were classified according to their mobility using a differential mobility analyzer. The projection area and the mass fractal dimension of particles were measured with an image processing technique performed by using transmission electron microscope (TEM) photograph. The selected aggregates were charged by the indirect photoelectric-charger and the average number of charges per particle was measured by an aerosol electrometer and a condensation particle counter. For the particles of same mobility diameter, our results showed that the particle charge quantity decreases as the sintering temperature increases. This result is understandable because particles with lower fractal dimension have larger capacitance and geometric surface area.

Measurements of Adhesion Force of Micro-Sized Toner Particles Deposited on the Developing Roller Surface in a Non-contact type Laser Printer (비접촉 방식 레이저 프린터 현상롤러 위에 부착된 마이크로 토너 입자의 부착힘 측정)

  • Kim Sang-Yoon;Lee Dae-Young;Sheen Sowon;Eun Jong Moon;Hwang Jungho
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.75-80
    • /
    • 2005
  • Study for toner adhesion is known as an important role in electrophotography. In this research, a centrifugal detachment method was used to measure the adhesion force of several hundred particles simultaneously and to determine its sensitivity to particle size. For uncharged toner particles, we estimated the van der Waals force based on the centrifugal farce experiments. Then for charged toner particles, the centrifugal force experiments were carried out. The difference between the results for charged toner particles and the results for uncharged toner particles was compared with the image force calculated from a model which assumed that the toner charge was located at the center of the particle. In the calculations, experimental data obtained by E-SPART (Electrical- Single Particle Aerodynamic Relaxation Time) analyzer were used. The adhesion force of micro-sized toner particles deposited on the DR surface was found to be approximately 1${\~}$3 nN.

  • PDF

Influence of Carbon Black Contents and Rubber Compositions on Formation of Wear Debris of Rubber Vulcanizates

  • Choi, Sung-Seen;Yang, Seong Ryong;Chae, Eunji;Son, Chae Eun
    • Elastomers and Composites
    • /
    • v.55 no.2
    • /
    • pp.108-113
    • /
    • 2020
  • Wear particles of the model tread compounds for bus and truck tires were made using a laboratory abrasion tester and characterized based on their size distributions, shapes, and crosslink densities. The influence of the carbon black contents and rubber compositions (NR= 100 and NR/BR= 80/20) on the production of wear particles was investigated. The wear particles were separated according to size using a sieve shaker. The shape properties of the wear particles were analyzed using an image analyzer and scanning electron microscopy (SEM). Their shapes were observed as tiny stick cookies or sausages with bumpy surfaces. The particle size distribution tended to be smaller with increasing carbon black content. Moreover, the particle size distributions of the NR = 100 samples were larger than that of the NR/BR blend samples. There were different filaments in the wear particles. The filament diameters tended to be thinner with increasing carbon black content. The crosslink density increased with increasing carbon black content, and the crosslink densities of the NR= 100 samples were lower than those of the NR/BR blend ones. The particle size distribution tended to be smaller with increasing crosslink density. Based on the experimental results, the wear particles can be produced by detaching debris from the main body through repetitive strain and recovery.

Measurements of Adhesion Force of Micro-Sized Toner Particles Deposited on the Developing Roller Surface in a Non-contact type Laser Printer (비접촉 방식 레이저 프린터 현상롤러 위에 부착된 마이크로 토너 입자의 부착힘 측정)

  • Kim, Sang-Yoon;Lee, Dae-Young;Sheen, So-Won;Eun, Jong-Moon;Hwang, Jung-Ho
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.105-110
    • /
    • 2006
  • Study for toner adhesion is 3non as an important role in electrophotography. In this research, a centrifugal detachment method was used to measure the adhesion force of several hundred particles simultaneously and to determine its sensitivity to particle size. For uncharged toner particles, we estimated the van der Waals force based on the centrifugal force experiments. Then for charged toner particles, the centrifugal force experiments were carried out. The difference between the results for charged toner particles and the results for uncharged toner particles was compared with the image force calculated from a model which assumed that the toner charge was located at the center of the particle. In the calculations, experimental data obtained by E-SPART (Electrical-Single Particle Aerodynamic Relaxation Time) analyzer were used. The adhesion force of micro-sized toner particles deposited on the DR surface was found to be approximately $1{\sim}3$ nN.

  • PDF

Spray Characteristics of the Rotating Fuel Injection System (회전연료 분사시스템의 분무특성)

  • Lee, D.H.;Park, J.B.;Choi, S.M.
    • Journal of ILASS-Korea
    • /
    • v.11 no.2
    • /
    • pp.81-88
    • /
    • 2006
  • The spray characteristics of the rotating fuel injection system were investigated. The special test rig was devised to get the spatial and momentary droplet information. This experimental apparatus consists of a high-speed motor, a shaft, a rotating fuel nozzle and an acrylic case. Spray droplet size and velocity were measured by PDPA(Phase Doppler Particle Analyzer) and instantaneous velocity field was measured by 1'IV (Particle Image Velocimetry) system. At the same time, spray visualization was performed by using ND-YAG laser-based flash photography. From these two different laser diagnostic techniques, we could get spatial and instantaneous spray information fur rotating fuel injection system. The results presented in this paper indicate that spray characteristics such as droplet size, velocity and spray pattern were strongly influenced by rotational speed.

  • PDF

Effects of Temperature on Flocculation Kinetics Using Fe(III) Coagulant in Water Treatment (정수처리시 Fe(III) 응집제를 사용한 응집동력학에 대한 온도의 영향)

  • 강임석
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.181-194
    • /
    • 1995
  • Flocculation kinetics using ferric nitrate as a coagulant to coagulate kaolin clay in water was examined as a tool to investigate the effect of low temperature under tightly controlled treatment conditions. Both the particle size distribution data obtained from Automatic Image Analysis (AIA) system and the on-line measurement of the degree of turbidity fluctuation in a flowing suspension by Photometric Dispersion Analyzer (PDA) were used to measure flocculation kinetics. Results show that cold water temperature had a pronounced detrimental effect on flocculation kinetics. For improving flocculation kinetics at low water temperature, maintaining constant pOH to adjust water chemistry for temperature changes was found to be partially effective only in the more acidic pH range studied.

  • PDF