• 제목/요약/키워드: Particle electrode

검색결과 385건 처리시간 0.028초

평등전계에서 도전성 구형 입자의 운동 (Motion of Conductive Spherical Particle under Uniform Electric Field)

  • 임헌찬
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.39-47
    • /
    • 2011
  • The motion of a conductive spherical particle under uniform electric field is investigated in order to find a suitable method for removing the conducting solid impurities contained in liquid plastic. When the positive dc voltage applied to the upper electrode, the vertical up-and-down motion of a charged particle by electrostatic force is observed by a charge-coupled device (CCD) camera or a high-speed video camera. The experimental data of the static threshold voltage by which the particle starts to move toward the counter electrode in air or silicone oil are in good agreement with theoretical value. When the applied voltage is larger than the static threshold voltage, the particle motion pattern in silicone oil consists of four stages: upward motion, stopping at the upper electrode, downward motion and stopping at the lower electrode. The stopping motion on the electrode is thought to be caused by the liquid flow accompanied by the particle motion. The particle charge calculated by integrating the pulse current, which is generated by the charge exchange between the electrode and the particle, is approximately 0.1~0.25 times of the theoretical value. This study is expected to help understand the electric properties of microparticles in oil circuit breaker (OCB) and oil transformer and improve their performance and longevity.

GIS내 금속이물 존재시 절연특성 (The Insulation Characteristics by Conducting Particle in GIS)

  • 조국희;김재철;곽희로
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.105-108
    • /
    • 2004
  • This paper describes the influence of conducting particle in the coaxial cylindrical electrodes under alternating voltage condition investigated using breakdown electric field and electro magnetics simulation method. Simulated particle-location in GIS chamber were the particle on electrode, the particle on enclosure and free moving particle. As results, it was founded that in case of breakdown electric field of the GIS chamber, breakdown electric field of particle on electrode was the lowest, that of free moving particle was middle and that of particle on enclosure was the highest. And in case of the electric field analysis with particle locations, electric field of particle on electrode was the highest that of lifted particle was middle and that of particle on enclosure was the lowest. This results can offer a practical reference ra the insulation design of domestic GIS.

  • PDF

나노영가철/활성탄 입자전극과 과황산을 이용한 3차원 전기화학적 산화공정 (Three-dimensional Electrochemical Oxidation process using Nanosized Zero-valent Iron/Activated carbon as Particle electrode and Persulfate)

  • 민동준;김철용;안준영;조수빈;황인성
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제23권6호
    • /
    • pp.104-113
    • /
    • 2018
  • A three-dimensional electrochemical process using nanosized zero-valent iron (NZVI)/activated carbon (AC) particle electrode and persulfate (PS) was developed for oxidizing pollutants. X-ray diffraction (XRD), scanning electron microscopy with energy dispersive spectroscopy (SEM-EDS), and Brunauer-Emmett-Teller (BET) surface area analysis were performed to characterize particle electrode. XRD and SEM-EDS analysis confirmed that NZVI was impregnated on the surface of AC. Compared with the conventional two-dimensional electrochemical process, the three-dimensional particle electrode process achieved three times higher efficiency in phenol removal. The system with current density of $5mA/cm^2$ exhibited the highest phenol removal efficiency among the systems employing 1, 5, and $10mA/cm^2$. The removal efficiency of phenol increased as the Fe contents in the particle electrode increased. The particle electrode achieved more than 70% of phenol removal until it was reused for three times. The sulfate radical played a predominant role in phenol removal according to the radical scavenging test.

탄소섬유 시트 방전극의 입자 크기 별 집진 특성 및 공기청정기로의 응용 (Particle collection characteristics of carbon fiber sheet discharge electrode by particle size and application to air cleaner)

  • 신동호;우창규;홍기정;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제14권3호
    • /
    • pp.81-88
    • /
    • 2018
  • The market for improving the indoor air quality is continuously increasing, and air cleaners are the representative products. As interest in indoor air quality increases, so are the ultrafine particle which are harmful to the human body. Despite its many advantages, electrostatic precipitators are less used in indoor air due to ozone production. In this study, the carbon fiber sheet was applied to the discharge electrode and compared with the conventional tungsten wire discharge electrode. The particle collection efficiency and the amount of ozone generation were measured for 10-100 nm particles. Furthermore, it was applied to commercial air purifier with electrostatic precipitator to compare particle removal performance. The carbon fiber sheet type discharge electrode generates a small amount of ozone, and thus it can be applied to improve indoor air quality.

$SF_6$가스 내 금속이물 존재시 절연특성 및 전계해석 (The Insulation Characteristics and The Electric Field Anlaysis by Conducting Particle in $SF_6$ Gas)

  • 조국희;이동준;곽희로
    • 조명전기설비학회논문지
    • /
    • 제15권5호
    • /
    • pp.14-19
    • /
    • 2001
  • 전계해석법을 이용하여 나타내었다. 이때 모의한 GIS 챔버내 금속이물의 위치는 전극부착시, 외함부착시 그리고 자유운동시로 하였다. 그 결과 GIS챔버의 절연파괴전계의 경우, 전극에 파티클 부착시가 가장 작게 나타났고, 파티클 자유운동시가 중간, 외함에 파티클 부착시가 가장 작게 나타남을 알 수 있었다. 또한 파티클 위치에 따른 전계해석의 경우 전극에 파티클 부착시가 가장 크게 나타났고, 파티클 자유운동시가 중간, 외함에 파티클 부착시가 가장 작게 나타났다. 이 결과는 국내 GIS의 절연설계에 설제적인 참고자료가 될 것으로 사료된다.

  • PDF

Surface Discharge in Various Electrode Geometries

  • Joh, Dai-Geun;Kim, Hyun-Sook;Gill, Do-Hyun;Kim, Young-Goun;Choi, Eun-Ha;Cho, Guang-Sup
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.111-112
    • /
    • 2000
  • The breakdown characteristics of surface discharge investigated experimentally agree well with the analytic results of previous reports [1-3] in various electrode geometries. Additionally, we find that the electrode geometry effects on the firing voltage can be understood with the ionization probability relating to the number of priming particles. We have also observed the shape of surface discharge and the surface striations in the gap geometry with the pressure, the applied voltage, and the driving frequency.

  • PDF

LTCC 기판의 Particle Size 에 따른 Ag-Pd 전극의 Soldering 특성 변화 (Soldering characteristics of Ag-Pd electrodes in relationship to differing particle size of LTCC substrate)

  • 조현민;유명재;박종철
    • 한국마이크로전자및패키징학회:학술대회논문집
    • /
    • 한국마이크로전자및패키징학회 2002년도 춘계 기술심포지움 논문집
    • /
    • pp.130-133
    • /
    • 2002
  • Solder leaching resistance of the metal electrode is an important factor with regard to adhesion properties of ceramic substrate. In the Low Temperature Co-fired Ceramics (LTCC), Ag-Pd or Ag-Pt pastes are used instead of pure Ag paste to prevent leaching. Solder leaching behavior of the Ag-Pd paste in relation to LTCC raw material powder size was investigated. First fabrication of LTCC green tape with different particle size was done. LTCC substrates with Ag-Pd electrode were prepared using conventional multilayer ceramic process. Dipping test was performed to test solder leaching behavior of the electrode. Ag-Pd electrode on LTCC substrate with smaller particle size achieved higher solder leaching resistance.

  • PDF

$SF_6$ GIS용 스페이서 표면에서의 파티클에 의한 절연파괴 특성연구 (A Study of Particle-Initiated Breakdown Characteristics on a Spacer Surface for $SF_6$ GIS)

  • 김재호;이용길;김동의;이세훈;김정달
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1536-1539
    • /
    • 1994
  • The influence due to metallic particle contaminated on spacer surface is remarkable in the decreasing of dielectric strength in $SF_6$ GIS. In relation with this problem, We studied, AC flash-over voltage characteristics and breakdown mechanism are investigated under metallic particle initiated condition in $SF_6$ gas by varying the particle position, particle shape with a plane-plane electrode. The main results arc as follows 1. The small amount of the metallic particle in the gap do not make flash-over voltage to be influence, but the significant decrease of th flash-overed voltage is result in case of the big and long size of the metallic paraticle. 2. Influence of the flash-over voltage are lowest in the mid and are highest in the electrode of metallic particle position. 3. In case of the initiated metallie particle, The more the pressure are high, the more the recluced ratio of flash-over voltage are high. 4. The metallic particle shape which results in the reduced flash-over voltage forced the critical pressure to move in to the region of low pressure. 5. The existance of the metallic particle on the upper electrode side and high pressure make the decreasing ratio of flash-over voltage bigger than that of the ground side electrode.

  • PDF

정전 고속 미스트 엘리미네이터의 포집 효율 특성 (Particle removal characteristics of high-velocity electrostatic mist eliminator)

  • 김진선;김학준;한방우;우창규;김용진;이상린;문상철
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.121-133
    • /
    • 2018
  • In this study, we developed a flat-plate type wet electrostatic precipitator that generates stable corona discharge compared to wire type discharge electrode. In order to compare the particle removal efficiency according to the shape of the discharge electrode such as the variation of the horizontal and vertical distance between spiked edges, and the variation of the height of discharge pin support were tested. As a result, when the horizontal distance between spiked edges was increased up to 36 mm, the vertical distance between spiked edges was increased up to 54 mm, and the height of the discharge pin support was increased up to 76 mm, the removal efficiency of PM10 was maintained at approximate 60.0%. Furthermore, the removal efficiency of particles over $5{\mu}m$ was about 80% or more. When the flow rate was 4 m/s, the gap between collection plates was 60 mm, and -14 kV was applied to the discharge electrode. The particle removal efficiency of the flat-plate type electrostatic precipitator was maintained when the horizontal and vertical distance between spiked edges, and the height of the discharge pin support was below a certain level. Those variables may be the important design factors for the shape of the discharge electrode. Therefore, when designing the electrostatic precipitator with multiple channels, the horizontal and vertical distance between spiked edges, and the height of discharge pin support must be selected in consideration of the weight of the discharge electrode and the processing cost.

유동층 전극반응기를 이용한 중금속폐수의 처리에 관한 연구 1. 전류공급원에서의 국부물질전달계수의 분포 (Treatment of Heavy Metal Wastewater Bed Electrode Reactor by a Fluidized 1. Distribution of Local Mass Transfer Coefficients on the Current Feeder)

  • 황영기;정은혁
    • 한국환경과학회지
    • /
    • 제6권1호
    • /
    • pp.1-8
    • /
    • 1997
  • Varing the flow velocity of solution and particle diameter, the mass transfer coefficient of the local electrode on current feeder has been measured in an empty flow reactor, an inert fluidized bed electrode reactor, and an active fluidized bed electrode reactor. It had its maximium value when the bed porosity was 0.6 to 0.65 and decreased with in- creasing the height of local electrode. The mass transfer coefficient was found to be high especially when higher particle was fluidized. Electrochemical deposition of copper dissolved in the synthesized wastewater has been performed in the active fluidized bed electrode reactor. The deduction rate was higher than 90% and the residual concentration of copper decreased to less than 5ppm.

  • PDF