• 제목/요약/키워드: Particle charging

검색결과 91건 처리시간 0.029초

패러데이 케이지와 에어로졸 하전기의 설계 및 성능평가 (Design and Performance Evaluation of a Faraday Cage and an Aerosol Charger)

  • 지준호;배귀남;황정호
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.315-323
    • /
    • 2004
  • An electrical cascade impactor is a multi-stage impaction device to separate airborne particles into aerodynamic size classes using particle charging and electrical detection techniques. A Faraday cage and an aerosol charger, which are basic components of the electrical cascade impactor, were designed and evaluated in this study. The low-level current response of the Faraday cage was investigated with changing particle size and air flow rate by using sodium chloride (NaCl) particles. The response of the prototype Faraday cage was very similar to that of a commercial aerosol electrometer (TSI model 3068) within ${\pm}$5% for singly-charged particles. The response linearity of the prototype Faraday cage could be extended up to flow rate of 30 L/min. For the performance evaluation of the aerosol charger the monodisperse liquid dioctyl sebacate (DOS) particles, with diameters of 0.1∼0.8$\mu\textrm{m}$, were generated using spraying from an atomizer followed by evaporation-condensation process. Typical performance parameters of the aerosol charger such as P$.$n, wall loss, and elementary charges per particle were evaluated. The performance of the prototype aerosol charger was found to be close to that of the aerosol charger used in an electrical low pressure impactor (ELPI, Dekati).

Shadowgraph 가시화 기법을 활용한 정전분무액적의 크기 측정 (Size measurement of electrosprayed droplets using shadowgraph visualization method)

  • 오민정;김성현;이명화
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.151-158
    • /
    • 2017
  • 실내 환경 및 산업체 배기가스중의 미세먼지를 제거하는 방법으로서 압력손실이 낮으면서도 집진효율이 높은 전기집진기가 널리 사용되어지고 있다. 그러나 전기집진기는 서브마이크로미터 크기의 먼지에 대한 제거효율이 낮기 때문에, 정전분무법으로 하전액적을 공급하여 먼지와의 충돌을 촉진시켜 하전효율을 높이는 방법이 대안으로 떠오르고 있다. 그러나 먼지의 하전효율은 정전분무된 액적의 크기 및 개수와 밀접한 관계가 있으나, 액적의 크기를 효과적으로 측정하는 방법이 확립되어 있지 않은 것이 현실이다. 본 연구에서는 손쉽게 이용할 수 있는 수돗물로 정전분무를 한 후, 분무된 액적을 다양한 방법으로 가시화하여 고속카메라로 촬영하였다. 그리고 Image J 프로그램으로 액적의 크기분포를 측정하여 가시화방법에 따른 액적의 크기를 상호 비교하였다. 결과적으로, 레이저로 가시화하여 고속카메라로 촬영하면 미세액적의 이미지화가 가능하기 때문에, 그 액적의 크기는 Xenon광으로 가시화하여 측정한 것보다 약 50 % 작음을 알 수 있었다. 또한 레이저로 가시화하여 측정한 액적의 크기가 $Fern{\acute{a}}ndez$ de la Mora and Loscertales (1994)의 예측치와 비교적 잘 일치함을 알 수 있었다.

Effects of Packing Conditions on Apparent Resistivity Measurements of Polymer Powders

  • Park, K.S;S. Kawai;Kim, T.Y.;M. Yamaguma;T. Kodama;J.H Joung;M. Masui;M. Takeuchi
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제12C권4호
    • /
    • pp.229-235
    • /
    • 2002
  • The apparent volume resistivity of powders measured by both the tapping and the compressing methods was compared in this study. Factors such as applied voltage, pressure, corona charging, and so on affecting the apparent volume resistivity of polymer powders were also examined experimentally. Powders of polyacrylonitrile and Nylon 11 were mainly used. The values of the apparent resistivity of polymer powders taken by the tapping method turned out to be larger than those taken by the compressing method, which indicates that the apparent volume resistivity of polymer powders depends strongly on the measurement method. The apparent resistivity of polymer powders increased with an increase in applied voltage while it decreased with an increase in pressure, tapping time, and particle size. The influence of the moisture content of powder and corona charging on the resistivity of polymer powders is also discussed.

실시간 에어로졸 측정장비를 이용한 대기 중 입자상 물질의 무게 농도 분포의 추정 (Estimation of Mass Size Distribution of Atmospheric Aerosols Using Real-Time Aerosol Measuring Instruments)

  • 지준호;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제9권2호
    • /
    • pp.39-50
    • /
    • 2013
  • SMPS, APS, ELPI는 실시간으로 대기 중 입자상 물질을 측정할 수 있는 장비로 많은 연구자들에 의해 사용되고 있다. 하지만 측정장비의 특성과 입자 분류 특성에 대한 충분한 이해가 없다면, 단순히 장비에 제공된 소프트웨어의 계산 결과를 여과 없이 그대로 사용할 수밖에 없다. 본 연구에서는 SMPS, APS, ELPI의 측정 메커니즘을 간단히 정리하였고, 전기적 이동도로 입자를 분리하는 SMPS와 공기역학적 거동을 이용하는 APS를 함께 사용하여 입자의 크기분포를 측정할 때 발생할 수 있는 문제점을 고찰하였다. 크기분포 측정결과를 이용해서 무게 농도를 환산하는 과정에서 대기 입자의 입경에 따른 밀도 정보를 제공하는 것이 매우 중요하다는 것을 보였다. 특히, APS 측정결과를 이용하는 경우 무게 농도의 추정 결과가 크게 영향을 받았다. ELPI의 경우 입자 밀도를 정확히 설정하지 않으면 입자의 수 농도에 오차가 크게 발생할 수 있으므로, 정확한 밀도를 설정하는 것이 중요했다. 반면에 ELPI로 대기 중입자상 물질의 무게 농도를 추정하는 경우 밀도가 실제와 다르게 설정되더라도 공기역학적 입경으로 나타내면 총 무게 농도는 수 농도에 비해 상대적으로 영향이 적었다. 향후 SMPS와 APS를 이용하여 시간에 따른 크기 분포 변화와 연간 수 농도와 무게 농도의 변화 추이를 측정하는 연구가 필요하다. 특히, 국내 대기 중입자의 입경에 따른 평균 밀도 혹은 유효 밀도를 측정하여 크기분포와 총 수 농도 혹은 PM2.5나 PM1에 해당하는 무게 농도를 정확하게 계산할 수 있는 데이터 환산 프로그램의 개발도 필요하다. 이와 같은 연구로 시간경과에 따라 변화하는 대기 입자의 오염원에 대한 영향을 규명하는 기초 자료를 얻을 수 있을 것이다.

3전극형 전자종이 디스플레이의 전자잉크 주입 방법에 따른 광학 특성 분석 (Analysis of Optical Characteristics According to Electronic Ink Loading Method of Three-Electrode Type E-Paper Display)

  • 이상일;홍연찬;김영조
    • 한국전기전자재료학회논문지
    • /
    • 제31권3호
    • /
    • pp.171-176
    • /
    • 2018
  • An electronic paper display was fabricated by injecting electronic ink, including white and black particles coated by positive and negative charge control agents (CCA), respectively, into closed cells surrounded by micro-barriers. These two types of charged, colored particles are easily damaged or their charging value can be changed by the injection process; therefore, the electrical and optical properties of the image panel fabricated by the injection method were estimated in this study. The active particle-loading method, proposed as a new electronic ink injection process, was applied, and the electro-optical properties of the resulting three-electrode-type e-paper image panel were analyzed. The reflection rate of the white image-panel fabricated with our new injection method was 24.7%, while that of the same panel fabricated with a previously reported injection method was 19.8%. In addition, the response time was improved by about five times compared to those reported in other publications.

Electrostatic Beneficiation of Coal Fly Ash Utilizing Triboelectric Charging with Subsequent Electrostatic Separation

  • Lee, Jae-Keun;Kim, Seong-Chan
    • Journal of Mechanical Science and Technology
    • /
    • 제15권6호
    • /
    • pp.804-812
    • /
    • 2001
  • A triboelectrostatic separation system for removing unburned carbon from coal fly ash is designed and evaluated. Fly ash from a coal-fired power plant is used as an accepted additive in concrete where it adds strength, sulfate resistance and reduced cost, provided acceptable levels of unburned carbon are maintained. Unfortunately, unburned carbon in coal fly ash absorbs some of other additives and reduces the concrete strength. This paper describes to investigate dry triboelectrostatic process to separate unburned carbon from coal fly ash and utilize it into economically valuable products. The laboratory-scale triboelectrostatic separation system consists of a particle feeding system, a tribocharger, a separation chamber, and collection systems. Particles of unburned carbon and fly ash can be imparted positive and negative surface charges, respectively, with a copper tribocharger due to differences in the work function values of the particles and the tribocharger, and can be separated by passing them through an external electric field. Results showed that fly ash recovery was strongly dependent on the electric field strength and the particle size. 70wt% of fly ash containing 6.5wt% of carbon contents could be recovered at carbon contents below 3%. The triboelectrostatic separation system showed a potential to be an effective method for removing unburned carbon from coal fly ash.

  • PDF

Satellite-based In-situ Monitoring of Space Weather: KSEM Mission and Data Application

  • Oh, Daehyeon;Kim, Jiyoung;Lee, Hyesook;Jang, Kun-Il
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권3호
    • /
    • pp.175-183
    • /
    • 2018
  • Many recent satellites have mission periods longer than 10 years; thus, satellite-based local space weather monitoring is becoming more important than ever. This article describes the instruments and data applications of the Korea Space wEather Monitor (KSEM), which is a space weather payload of the GeoKompsat-2A (GK-2A) geostationary satellite. The KSEM payload consists of energetic particle detectors, magnetometers, and a satellite charging monitor. KSEM will provide accurate measurements of the energetic particle flux and three-axis magnetic field, which are the most essential elements of space weather events, and use sensors and external data such as GOES and DSCOVR to provide five essential space weather products. The longitude of GK-2A is $128.2^{\circ}E$, while those of the GOES satellite series are $75^{\circ}W$ and $135^{\circ}W$. Multi-satellite measurements of a wide distribution of geostationary equatorial orbits by KSEM/GK-2A and other satellites will enable the development, improvement, and verification of new space weather forecasting models. KSEM employs a service-oriented magnetometer designed by ESA to reduce magnetic noise from the satellite in real time with a very short boom (1 m), which demonstrates that a satellite-based magnetometer can be made simpler and more convenient without losing any performance.

에어핸들링 유닛의 공기정화용 전기집진기의 방전극 비교 (Comparison of discharging electrodes for the electrostatic precipitator as an air filtration system in air handling units)

  • 신동호;우창규;김학준;김용진;한방우
    • 한국입자에어로졸학회지
    • /
    • 제13권1호
    • /
    • pp.11-16
    • /
    • 2017
  • Indoor air quality is of increasing concern because it is closely related human health. An air handling unit (AHU) can be used to control the indoor air quality related to particulate matters and $CO_2$ as well as air conditioning such as temperature and humidity of indoor air. An electrostatic precipitator has a high collection efficiency and low pressure drop, however, ozone can possibly generate from its chargers, which is one of drawbacks to apply it for indoor air control. Here we compared four charging electrodes such as a $50{\mu}m$ tungsten wire, a $100{\mu}m$ tungsten wire, a $16{\mu}m$-thickness Al foil and a carbon fabric comprised of $5-10{\mu}m$ fibers. The carbon fabric electrode showed a superior particle collection efficiency and a lower ozone generation at a given power consumption compared to tungsten wires of 50, $100{\mu}m$ and an Al foil electrode. This low ozone generating, micro-sized electrode can be applied to the electrostatic precipitator in AHU for indoor air control.

정전선별법을 이용한 석탄회로부터 미연탄소분 제거에 관한 연구

  • 최우진;염영길
    • 한국지하수토양환경학회:학술대회논문집
    • /
    • 한국지하수토양환경학회 1998년도 공동 심포지엄 및 추계학술발표회
    • /
    • pp.97-105
    • /
    • 1998
  • The goal of this study is to investigate the potential application of triboelectrostatic separation process for removing unburned carbon from fly ash. The process utilizes the difference in electrical charging characteristics between the organic material (carbon) and the mineral matter (fly ash). In the present work, dry separation tests have been conducted on Samchunpo fly ash samples using a bench - scale analytic separator. The test variables studied include air rate, feed rate, electric field strength, particle size, charger material and length, etc. The best separation results were obtained at the air rate 501/min, feed rate 15 g/min and voltage 15 ㎸. The fly ash with carbon content below 1 % was obtained with over 65% recovery.

  • PDF

Corona Discharge Characteristics and Particle Losses in a Unipolar Corona-needle Charger Obtained through Numerical and Experimental Studies

  • Intra, Panich;Yawootti, Artit;Rattanadecho, Phadungsak
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.2021-2030
    • /
    • 2017
  • In this paper, the unipolar corona-needle charger was developed and its capabilities were both numerically and experimentally investigated. The experimental corona discharges and particle losses in the charger were obtained at different corona voltage, aerosol flow rate and particle diameter for positive and negative coronas. Inside the charger, the electric field and charge distribution and the transport behavior of the charged particle were predicted by a numerical simulation. The experimental results yielded the highest ion number concentrations of about $1.087{\times}10^{15}ions/m^3$ for a positive corona voltage of about 3.2 kV, and $1.247{\times}10^{16}ions/m^3$ for a negative corona voltage of about 2.9 kV, and the highest $N_it$ product for positive and negative coronas was found to about $7.53{\times}10^{13}$ and $8.65{\times}10^{14}ions/m^3$ s was occurred at the positive and negative corona voltages of about 3.2 and 2.9 kV, respectively, and the flow rate of 0.3 L/min. The highest diffusion loss was found to occur at particles with diameter of 30 nm to be about 62.50 and 19.33 % for the aerosol flow rate of 0.3 and 1.5 L/min, respectively, and the highest electrostatic loss was found to occur at particles with diameters of 75 and 50 nm to be about 86.29 and 72.92 % for positive and negative corona voltages of about 2.9 and 2.5 kV, respectively. The numerical results for the electric field distribution and the charged particles migration inside the charger were used to guide the description of the electric field and the behavior of charged particle trajectories to improve the design and refinement of a unipolar corona-needle charger that otherwise could not be seen from the experimental data.