• 제목/요약/키워드: Particle beam

검색결과 386건 처리시간 0.025초

Atom Probe Tomography: A Characterization Method for Three-dimensional Elemental Mapping at the Atomic Scale

  • Choi, Pyuck-Pa;Povstugar, Ivan
    • 한국분말재료학회지
    • /
    • 제19권1호
    • /
    • pp.67-71
    • /
    • 2012
  • The present paper gives an overview about the Atom Probe Tomography technique and its application to powder materials. The preparation of needle-shaped Atom Probe specimens from a single powder particle using focused-ion-beam milling is described. Selected experimental data on mechanically alloyed (and sintered) powder materials are presented, giving insight into the atomic-scale elemental redistribution occurring under powder metallurgical processing.

이온빔을 이용한 마이크로/나노 가공: 모델링 (Ion Beam Induced Micro/Nano Fabrication: Modeling)

  • 김흥배
    • 한국정밀공학회지
    • /
    • 제24권8호통권197호
    • /
    • pp.108-115
    • /
    • 2007
  • 3D nano-scale manufacturing is an important aspect of advanced manufacturing technology. A key element in ability to view, fabricate, and in some cases operate micro-devices is the availability of tightly focused particle beams, particularly of photons, electrons, and ions. The use of ions is the only way to fabricate directly micro-/ nano-scale structures. It has been utilized as a direct-write method for lithography, implantation, and milling of functional devices. The simulation of ion beam induced physical and chemical phenomena based on sound mathematical models associated with simulation methods is presented for 3D micro-/nanofabrication. The results obtained from experimental investigation and characteristics of ion beam induced direct fabrication will be discussed.

The Effects of Electron Beam Exposure Time on Transmission Electron Microscopy Imaging of Negatively Stained Biological Samples

  • Kim, Kyumin;Chung, Jeong Min;Lee, Sangmin;Jung, Hyun Suk
    • Applied Microscopy
    • /
    • 제45권3호
    • /
    • pp.150-154
    • /
    • 2015
  • Negative staining electron microscopy facilitates the visualization of small bio-materials such as proteins; thus, many electron microscopists have used this conventional method to visualize the morphologies and structures of biological materials. To achieve sufficient contrast of the materials, a number of imaging parameters must be considered. Here, we examined the effects of one of the fundamental imaging parameters, electron beam exposure time, on electron densities generated using transmission electron microscopy. A single site of a negatively stained biological sample was illuminated with the electron beam for different times (1, 2, or 4 seconds) and sets of micrographs were collected. Computational image processing demonstrated that longer exposure times provide better electron densities at the molecular level. This report describes technical procedures for testing parameters that allow enhanced evaluations of the densities of electron microscopy images.

Simulation of a Polarimeter for a Spin-Polarized Positron Beam

  • Kim, J.H.;Saito, F.;Suzuki, N.;Wei, L.;Nagashima, Y.;Kurihara, T.;Goto, A.;Itoh, Y.;Lee, Y.S.;Hyodo, T.
    • Journal of Korean Vacuum Science & Technology
    • /
    • 제6권3호
    • /
    • pp.116-119
    • /
    • 2002
  • A performance of a new positron polarimeter is investigated by simulation using a charged-particle trajectory program. The results of the ray tracing are presented along with the details of the design parameters and projected system performance. A ray tracing analysis indicates that this design is capable of effectively transmitting positrons at beam energies varying from 0.1 to 30 keV within the beam diameter of 2-6mm. However, the observed reflection of the positrons(lower than 2 keV) at 12 kGauss indicated that further refinement of beam design is needed to produce a better positron polarimeter.

  • PDF

30nm~3000nm 광범위 직경 입자의 공기역학적 집속에 대한 수치해석 (A Numerical Simulation of Aerodynamic Focusing of Nanoparticles in a Wide Range of 30nm~3000nm)

  • 이광승;이동근
    • 한국입자에어로졸학회지
    • /
    • 제7권4호
    • /
    • pp.123-130
    • /
    • 2011
  • Previous designs of conventional aerodynamic lenses have a limitation of narrow range of focusable particle size, e.g. 30 to 300nm or 3 to 30nm. To enlarge the focusable size range to 30-3000nm, it is necessary to avoid a significant loss of particles larger than 300nm inside the lenses. From numerical simulations on size-resolved particle trajectories, we confirmed that the traveling losses of such large particles could be avoided only when the radial position of particles approaching the orifice lens was near the lens axis. Hence, we designed the lens system consisting of a converging-diverging nozzle and 7 orifices to fulfill the requirement. In particular, the orifices were aligned in a way that their diameters were descending and ascending to the downstream. As a result, 30-2800nm particles can be focused to the particle beam of 0.2mm or less in radius with above 85% transmission efficiency. Even $10{\mu}m$ particles can be focused with 74% of transmission efficiency.

몬테카를로 시뮬레이션을 통한 중하전입자의 콘크리트 방사화 비교평가 (Comparative Evaluation of Radioactive Isotope in Concrete by Heavy Ion Particle using Monte Carlo Simulation)

  • 배상일;조용인;김정훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.359-365
    • /
    • 2021
  • A heavy particle accelerator is a device that accelerates particles using high energy and is used in various fields such as medical and industrial fields as well as research. However, secondary neutrons and particle fragments are generated by the high-energy particle beam, and among them, the neutrons do not have an electric charge and directly interact with the nucleus to cause radiation of the material. Quantitative evaluation of the radioactive material produced in this way is necessary, but there are many difficulties in actual measurement during or after operation. Therefore, this study compared and evaluated the generated radioactive material in the concrete shield for protons and carbon ions of specific energy by using the simulation code FLUKA. For the evaluation of each energy of proton beam and carbon ion, the reliability of the source term was secured within 2% of the relative error with the data of the NASA Space Radiation Laboratory(NSRL), which is an internationally standardized data. In the evaluation, carbon ions exhibited higher neutron flux than protons. Afterwards, in the evaluation of radioactive materials under actual operating conditions for disposal, a large amount of short-lived beta-decay nuclides occurred immediately after the operation was terminated, and in the case of protons with a high beam speed, more radioactive products were generated than carbon ions. At this time, radionuclides of 44Sc, 3H and 22Na were observed at a high rate. In addition, as the cooling time elapsed, the ratio of long-lived nuclides increased. For nonparticulate radionuclides, 3H, 22Na, and for particulate radionuclides, 44Ti, 55Fe, 60Co, 152Eu, and 154Eu nuclides showed a high ratio. In this study, it is judged that it is possible to use the particle accelerator as basic data for facility maintenance, repair and dismantling through the prediction of radioactive materials in concrete according to the cooling time after operation and termination of operation.

화염증 CO2 Laser를 이용한 입자의 크기 및 형상 제어 (Control of Size and Morphology of Particles Using CO2 Laser in a Flame)

  • 이동근;이선재;최만수
    • 대한기계학회논문집B
    • /
    • 제23권11호
    • /
    • pp.1379-1389
    • /
    • 1999
  • A new technique for control of size and shape of flame-made particles is Introduced. The characteristic sintering time can be controlled Independently of collision time by heating the particles with irradiation of laser because the sintering time strongly depends on temperature. A coflow oxy-hydrogen diffusion flame burner was used for $SiCl_4$ conversion to silica particle. Nanometer sized aggregates irradiated by a high power CW $CO_2$ laser beam were rapidly heated up to high temperatures and then were sintered to approach volume-equivalent spheres. The sphere collides much slower than the aggregate, which results in reduction of sizes of particles maintaining spherical shape. Light scattering of Ar ion laser and TEM observation using a local sampling device were used to confirm the above effects. When the $CO_2$ laser was irradiated at low position from the burner surface, particle generation due to gas absorption of laser beam occurred and thus scattering intensity increased with $CO_2$ laser power. At high irradiation position, scattering intensity decreased with $CO_2$ laser power and TEM image showed a clear mark of evaporation and recondensation of particles for high $CO_2$ laser power. When the laser was irradiated between the above two positions where small aggregates exist, average size of spherical particles obviously decreased to 58% of those without $CO_2$ laser irradiation with the spherical shape. Even for increased carrier gas flow rate by a factor of three, TEM photograph also revealed considerable reduction of particle size.

Measurement of Proton Beam Dose-Averaged Linear Energy Transfer Using a Radiochromic Film

  • Seohyeon An;Sang-il Pak;Seonghoon Jeong;Soonki Min;Tae Jeong Kim;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.80-87
    • /
    • 2022
  • Purpose: Proton therapy has different relative biological effectiveness (RBE) compared with X-ray treatment, which is the standard in radiation therapy, and the fixed RBE value of 1.1 is widely used. However, RBE depends on a charged particle's linear energy transfer (LET); therefore, measuring LET is important. We have developed a LET measurement method using the inefficiency characteristic of an EBT3 film on a proton beam's Bragg peak (BP) region. Methods: A Gafchromic EBT3 film was used to measure the proton beam LET. It measured the dose at a 10-cm pristine BP proton beam in water to determine the quenching factor of the EBT3 film as a reference beam condition. Monte Carlo (MC) calculations of dose-averaged LET (LETd) were used to determine the quenching factor and validation. The dose-averaged LETs at the 12-, 16-, and 20-cm pristine BP proton beam in water were calculated with the quenching factor. Results: Using the passive scattering proton beam nozzle of the National Cancer Center in Korea, the LETd was measured for each beam range. The quenching factor was determined to be 26.15 with 0.3% uncertainty under the reference beam condition. The dose-averaged LETs were measured for each test beam condition. Conclusions: We developed a method for measuring the proton beam LET using an EBT3 film. This study showed that the magnitude of the quenching effect can be estimated using only one beam range, and the quenching factor determined under the reference condition can be applied to any therapeutic proton beam range.

집속이온빔을 이용한 구리 기판위에 성장한 MgO 박막의 스퍼터링 수율 (Sputtering yield of the MgO thin film grown on the Cu substrate by using the focused ion beam)

  • 현정우;오현주;추동철;최은하;김태환;조광섭;강승언
    • 한국진공학회지
    • /
    • 제10권4호
    • /
    • pp.396-402
    • /
    • 2001
  • 전자빔 증착기를 이용하여 1000 $\AA$의 두께를 가진 MgO박막을 구리 기판위에 상온에서 증착하였다. 스퍼터링수율 측정시 MgO 층에 충전현상을 없애주기 위해서 1000 $\AA$ 두께의 Al을 증착하였다. 갈륨 액체금속을 집속이온빔 이온원으로 사용하였다. 두 개의 정전렌즈를 사용하여 이온빔을 집속하였고, MgO에 이온빔을 주사하기 위해 편향기를 사용하였다. 가속전압의 변화에 따라 시료대 전류와 이차입자 전류를 측정하였고, 이 전류값은 소스에 인가하는 가속전압에 따라 변화되었다 MgO 박막의 스퍼터링 수율은 분석된 시료대 전류, 이차입자 전류 및 순수빔 전류의 값을 사용하여 결정하였다. 집속이온빔 장치의 가속전압이 15 kV일 때 MgO 박막의 스퍼터링 수율은 0.30으로 나왔고 가속전압의 값이 증가할 때 스퍼터링 수율이 선형적으로 증가하였다. 이러한 결과를 볼 때 집속이온빔 장치를 이용하면 MgO 박막의 스퍼터링 수율을 측정할 패 매우 효과적임을 알 수 있다.

  • PDF

Installation for Preparing of Nanopowders by Target Evaporation with Pulsed Electron Beam

  • Sokovnin S. Yu.;Kotov Yu. A.;Rhee C. K.
    • 한국분말재료학회지
    • /
    • 제12권3호
    • /
    • pp.167-173
    • /
    • 2005
  • Production of weakly agglomerated nanopowders with the characteristic size of about 10 nm and a narrow particle size distribution is still a topical problem especially if the matter is an acceptable output (>50 g/hour), a high purity of the final product, and a low (energy consumption. The available experience and literature data show that the most promising approach to production of such powders is the evaporation-condensation method, which has a set of means for heating of the target. From this viewpoint the use of pulsed electron accelerators for production of nanopowders is preferable since they allow a relatively simple adjustment of the energy, the pulse length, and the pulse repetition rate. The use of a pulsed electron accelerator provides the following opportunities: a high-purity product; only the target and the working gas will interact and their purity can be controlled; evaporation products will be removed from the irradiation zone between pulses; as a result, the electron energy will be used more efficiently; adjustment of the particle size distribution and the characteristic size of particles by changing the pulse energy and the irradiated area. Considering the obtained results, we developed a design and made an installation for production of nanopowders, which is based on a hollow-cathode pulsed gas-filled diode. The use of a hollow-cathode gas-filled diode allows producing and utilizing an electron beam in a single chamber. The emission modulation in the hollow cathode will allow forming an electron beam 5 to 100 ms long. This will ensure an exact selection of the beam energy. By now we have completed the design work, manufactured units, equipped the installation, and began putting the installation into operation. A small amount of nanopowders has been produced.