• Title/Summary/Keyword: Particle beam

Search Result 386, Processing Time 0.031 seconds

Simulation of High-Power Magnetron Oscillators Using a MAGIC3D Code (MAGIC3D 코드를 애용한 고출력 마그네트론 발진기의 시뮬레이션)

  • Jung, S.S.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.11
    • /
    • pp.538-543
    • /
    • 2006
  • A high-Power continuous-wave (CW) ten-vane double-strapped magnetron oscillator has been investigated using three-dimensional (3D) particle-in-cell (PIC) numerical simulation code, MAGIC3D. The resonant modes and their resonant frequencies of the ten-vane strapped magnetron resonator were obtained to show a large mode separation near the ${\pi}$-mode. An electron cloud formed in an anode-cathode gap, called an interaction space was confined well enough to result in no leakage current. Five spokes were clearly observed in the electron cloud, which definitely ensured the ${\pi}$-mode oscillation in the ten-vane magnetron. Numerical simulations predicted that the saturated microwave output power measured at the coaxial output port was 5.41 kW at the microwave frequency of 893 MHz, corresponding to a power conversion efficiency of 72.6% when the external axial magnetic field was 1150 gauss and the electron beam voltage and current were 6 kV and 1.25 A, respectively.

STATUS OF WELDING FOR POWER PLANT FACILITIES

  • Hur, Sung-do
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.342-348
    • /
    • 2002
  • The welding technology for production of power plant facility as for other industries has been progressing forward automation and mechanization for cost reduction and shortening of cycle time. The welding for boiler tube is automated or mechanized as the parts and subassemblies of tubes are conveyed automatically in the shop. The temperature of boiler stearn is being progressively increased for higher plant efficiency. The welding of nuclear component is characterized by heavy thickness and narrow gap Submerged Arc Welding. Narrow gap Gas Metal Arc Welding and Electron Beam Welding is applied to turbine diaphragm. To improve the resistance of solid particle erosion of turbine blade and nozzle partition, HVOF spray technology and boriding process has been applied.

  • PDF

Wear Debris Coacentration Measurement by Laser Beam Attenuation (광감쇄를 이용한 마모입자의 농도 측정)

  • 강기호;손정영;전형욱;윤의성;안효석
    • Tribology and Lubricants
    • /
    • v.6 no.2
    • /
    • pp.94-98
    • /
    • 1990
  • The size and concentration of wear debris in lubricating oil often reveal the operating condition of the rotating machinery. To evaluate the possible application of light attenuation measurement for the estimation of wear debris concentration in the lubricating oil, the light transmittance through the lubricating oil cell contaminated with various concentrations of diatomire particles was measured, the attenuation coefficient was estimated from the transmittance measurement and the coefficients were compared with those obtained from the scattering theory. The comparision showed good agreements between them. It is also noted that the experimentally determined attenuation coefficient showed almost linear relation with particle weight coucentrations for the concentrations within the range of 2000 ppm. For the case of 0 ppm weight concentration of diatomire particles in the lubricating oil cell, the thickness of the cell required to give $100 \muW$ light attenuation is 7.75 mm. This result indicates that the light attenuation method will be one of the possible candidates of machine failure diagnostic sensors for the estimation of wear debris concentration in the lubricating oil.

Development of nonlinear crystals and blue SHG laser

  • Furukawa, Yasunori;Makio, Satoshi;Miyai, Tsuyoshi;Sato, Masayoshi
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.293-324
    • /
    • 1996
  • Compact solid-state blue laser have great potential for use in optical data storage, laser beam printing, particle countering, reprographics, holography, and fluorescent bioanalysis. We report recent progresses in qualities of LiB3O5 and K3Li2(TaxNb1-x)5O15 nonlinear crystals which are essential in manufacturing bulk-type blue SHG devices. We also review newly developed violet-blue laser, 20 mW output, using intracavity frequency doubling of a diode laser pumped Cr:LiSrAlF6 laser with low loss LiB3O5 crystal as a frequency doubler.

  • PDF

New Methods in the Technology of Electroluminescent Phosphors

  • Sychov, M.M.;Bahmet'ev, V.V.;Khavanova, L.V.;Kuznetsov, A.I.;Smimov, A.;Vasil'eva, I.V.;Mjakin, S.V.;Nakanishi, Y.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.1065-1070
    • /
    • 2003
  • Controlling synthesis conditions of ZnS:Cu,Al and ZnS:Cu electroluminescent phosphors we optimized particle size, color properties and efficiency. Surface properties were studied by new method and showed correlation with luminescence as shown by the analysis of EL spectra with Fok-Alentsev method. Luminance and maintenance improvement was achieved by the electron-beam annealing due to additional decomposition of $ZnS-Cu_{2}S$ solid solution and formation of centers of blue luminescence.

  • PDF

Optical Trapping of Microparticles Using a 790 nm Semiconductor Laser (790 nm의 반도체 레이저를 이용한 미세 입자의 포획)

  • 유석진;이진서;안지수;권남익
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.1
    • /
    • pp.24-27
    • /
    • 1996
  • We describe the optical trapping of yeast particles of $3~4\mu\textrm{m}$ in water solution using a diode laser operating at 790 nm. The yeast particles are trapped by a laser focus and are moved in 2- or 3-dimensions. This confirms the concept of negative light pressure by the gradient force due to the difference of the index of refractions of solutions and particles. By moving yeast particle vertically to the laser beam axis, we measured the horizontal component of the trapping force and compared it with the laser power.

  • PDF

In-Line Hologram for Plasma Diagnostics

  • Kim, Byungwhan;Jung, Jin-Su
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.524-529
    • /
    • 2016
  • Diagnostic sensors are demanded during plasma processes. Holograms of plasma taken with laser light without a reference beam were used to monitor behaviors of charged particles produced in nitrogen plasma as a function of electrode temperature ranging between 50 and 300℃. Holograms were characterized as a function of the pixel sum and grayscale value. Pixel sum calculated in identified grayscale ranges strongly correlated with ion density and emitted light intensity measured with a langmuir probe and optical emission spectroscopy, respectively. The performance was further evaluated with data acquired as a function of N2 and NH3 flow rates and improved correlations were observed in the new grayscale range. The confirmed correlations indicate that a hologram is a viable means to diagnose behaviors of plasma particles such as ions. Underlying principles are discussed in view of particle and charge composing vacuum and light.

Fabrication and Optical Characterization of Colloidal 3-D Photonic Crystals

  • N. Y. Ha;Y. Woo;Park, Byungchoo;J. W. Wu
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.15-16
    • /
    • 2003
  • 3-D photonic band-gap structures are fabricated from dielectric colloidal polystyrene beads through a centrifuge method. The fabricated photonic crystals exhibit opalescent colors under white light and show a clear diffraction peak dependent on the incident angle of the light beam. Also the scanning electron microscope image was taken to verify the face-centered cubic crystal structure. Bragg's law and Snell's law are employed to describe the position of angle resolved diffraction peaks. It was shown that the optically deduced effective refractive index and lattice constants were in good agreement with the crystal structure identified by scanning electron microscope.

Modelling on Sheath Expansion of Two-dimensional Grid Electrodes

  • Yi, Changho;Namkung, Won;Cho, Moohyun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.243.1-243.1
    • /
    • 2014
  • For two-dimensional grid electrodes immersed in plasmas, sheath expansion due to negative high-voltage pulse applied to the electrode generates high-energy pseudowave. The high-energy pseudowave can be used as ion beam for ion implantation. To estimate ion dose due to high-energy pseudowave, investigation on sheath expansion of grid electroes is necessary. To investigate sheath expansion, an analytic model was developed by Vlasov equation and applying the 1-D sheath expansion model to 2-D. Because of lack of generalized 2-D Child-Langmuir current, model cannot give solvable equation. Instead, for a given grid electrode geometry, the model found the relations between ion distribution functions, Child-Langmuir currents, and sheath expansions. With these relations and particle-in-cell (PIC) simulations, for given grid electrode geometry, computation time was greatly reduced for various conditions such as electrode voltages, plasma densities, and ion species. The model was examined by PIC simulations and experiments, and they well agreed.

  • PDF

Error Rate for the Limiting Poisson-power Function Distribution

  • Joo-Hwan Kim
    • Communications for Statistical Applications and Methods
    • /
    • v.3 no.1
    • /
    • pp.243-255
    • /
    • 1996
  • The number of neutron signals from a neutral particle beam(NPB) at the detector, without any errors, obeys Poisson distribution, Under two assumptions that NPB scattering distribution and aiming errors have a circular Gaussian distribution respectively, an exact probability distribution of signals becomes a Poisson-power function distribution. In this paper, we show that the error rate in simple hypothesis testing for the limiting Poisson-power function distribution is not zero. That is, the limit of ${\alpha}+{\beta}$ is zero when Poisson parameter$\kappa\rightarro\infty$, but this limit is not zero (i.e., $\rho\ell$>0)for the Poisson-power function distribution. We also give optimal decision algorithms for a specified error rate.

  • PDF