• Title/Summary/Keyword: Particle Mobility

Search Result 203, Processing Time 0.024 seconds

Development and Evaluation of Hy-SMPS (Hy-SMPS의 개발 및 성능평가)

  • Lee, Hong-Ku;Eun, Hee-Ram;Lee, Gun-Ho;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.11 no.2
    • /
    • pp.57-61
    • /
    • 2015
  • Atmospheric nano-particles along the altitude is one of the main factors causing severe weather phenomena. It is a challenge to find the precise particle size distribution. One useful instrument includes a scanning mobility particle sizer (SMPS). This measures the size distribution of submicron aerosols. The SMPS consists of a condensation particle counter (CPC), differential mobility analyzer (DMA), high voltage power supplier (HVPS), and neutralizer. Due to the many components, it is difficult to install a commercial SMPS into a tethered balloon package system (Eun, 2011). In this study, we customized a SMPS for the tethered balloon package system called Hy-SMPS. It is portable, compact in structure, and evaluated by TSI SMPS using mono and poly-dispersed particles.

Electrical Mobility Behavior of Nanoparticle Fractal Agglomerates in the Slip Regime (미끄럼 영역에 있는 나노입자 프랙탈 응집체의 전기이동도 거동 특성)

  • Shin, Weon Gyu
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.2
    • /
    • pp.211-216
    • /
    • 2013
  • For diffusion limited cluster agglomerates the ratio of the mobility radius to the radius of gyration $R_m/R_g$ vs. N and the ratio of the mobility radius to the radius of primary particle $R_m$/a are determined using experimental data obtained with DMA-APM and tandem DMA over a range of Knudsen numbers extending into the transition region where there is a lack of data. It was found that in slip regime with the number of primary particles between 100 and 400, datapoints are found to be between the two asymptotic lines for the continuum and free molecular regimes as those datapoints are plotted in both $R_m/R_g$ vs. N and $R_m$/a vs. N.

Performance Evaluation of Domestic -made DOC for the Heavy-duty Diesel Engine (국내 제작된 대형 디젤산화촉매의 배출가스 성능평가)

  • 정일록;엄명도;김종춘;김태승;류정호;임철수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.15-23
    • /
    • 1999
  • In recent years, environmental damage to urban area becomes serious problem due to the exhaust emissions by increasing the number of vehicle . Especially, diesel particulate matters(DPM) are hazardous air pollutant s to human health and environment. The reduction technologies of exhaust emissions from diesel engines are improvement of engine combustion, fuel quality and development of diesel exhaust aftertreatment. In this study, a diesel oxidation catalyst(DOC) that is one of diesel exhaust aftertreatments was made for performance evaluation . It was tested for NA and turbocharged engine by D-13 mode that currently be used for regulation driving test mode in Korea Scanning mobility particle sizer (SMPS) was used for the analysis of the particle size distribution with and w/o DOC. As the results , for NA and tubochartged engine, CO, THC, DPM was respectively reduced 85.7, 40.7,3.3% and 79.1, 53.1, 11.6% by DOC. Test results of particle size distribution was showed that particle number is 107 ~108per ㎤ , 2 $\times$105 ~5$\times$105$\mu\textrm{g}$/㎥ for weight concentration and 100~200nm for particle mean size in diesel engine and there is no effect to reduce the particle concentration by the DOC.

  • PDF

FIELD EXPERIENCE OF PORTABLE SMPS+C NANO PARTICLE SIZER

  • Gerhart, Ch.;Grimm, H.J.;Heim, M.
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.47-48
    • /
    • 2003
  • This new family of portable real time SEQUENTIAL MOBILITY PARTICLE COUNTER and SIZER (SMPS+C) is designed for mobility and easy field use. An integrated battery assures hours of operation, a data logger system storage of all optioned results and a user friendly powerful software easy operation. This technology not only simplifies the SMPS operation, but it permits new on site application monitoring up to a remote wireless telephone operation. (omitted)

  • PDF

Characteristics of Aerosol Particle Concentration by the Versatile Aerosol Concentration Enrichment System (VACES) (VACES을 이용한 대기 중 입자상물질의 농축기술 및 특성 연구)

  • Park, Jeong-Ho
    • Journal of Environmental Science International
    • /
    • v.21 no.11
    • /
    • pp.1339-1348
    • /
    • 2012
  • The versatile aerosol concentration enrichment system (VACES) have proven useful for providing elevated levels of atmospheric aerosol to human and animal exposures. In this study, we describe a VACES and tests conducted to both optimize the enhancement factor (EF) and characterize how it depends on experiment conditions. Particle number concentrations were measured from upstream and downstream of the system by scanning mobility particle sizer (SMPS) with a long differential mobility analyzer (DMA) in combination with a condensation particle counter (CPC). SMPS was used for to determine VACES particle EF. Particle EF tends to increase for higher the saturator temperature ($T_{Sat}$) and lower the condenser temperature ($T_{Con}$). $T_{Con}$ higher than $0^{\circ}C$ and $T_{Sat}$ lower than $50^{\circ}C$ was the best to obtain the most increase in particle concentration. Correlation analysis of EF with factor variables of $T_{Sat}$ and $T_{Con}$ resulted in correlation 0.662 and 0.416, respectively. With all five predictor variables included in a multiple regression model, the EF had a liner correlation with $R^2=0.643$.

Study of Incipient Soot Particles with Measuring Methodologies (입자 측정방법을 통한 초기 수트입자 연구)

  • Lee Eui Ju
    • Journal of the Korean Society of Visualization
    • /
    • v.2 no.1
    • /
    • pp.12-17
    • /
    • 2004
  • The physical characteristics of soot near the soot inception point were investigated with various measurements. In-situ measurements of particle size and volume fraction were introduced based on time resolved laser-induced incandescence (TIRE-LII) and laser-induced ion mobility (LIIM). The one has more convenience and accuracy than conventional LII technique and the other works best for particle sizes of a few nanometers at high concentrations in a uniform concentration field. A complementary ex-situ measurement of particle size is nano differential mobility analyzer (Nano-DMA), which recently developed for measuring particle sizes between 2nm and 100nm and provides high-resolution size information for early soot. Particles will be also collected on transmission electron microscope (TEM) grids using rapid thermophoretic sampling and analyzed for morphology. These measurements will allow fresh and original insight into the characterizing soot inception process. The measured physical properties of incipient soot will clarify the controlling growth mechanism combined with chemical ones, and the dominant mechanism for soot modeling can be deduced from the information.

  • PDF

An Experimental Study on Composition Characteristics of $SiO_2/TiO_2$ Multicomponent Particle in Coflow Diffusion Flame (화염중 발생하는 $SiO_2/TiO_2$ 다성분입자의 조성특성에 관한 실험적 연구)

  • Kim, Tae-Oh;Suh, Jeong-Soo;Choi, Man-Soo
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.441-446
    • /
    • 2000
  • Chemical compositions of monodisperse $SiO_2/TiO_2$ multicomponent aggregates were measured for different heights from the burner surface and different mobility diameters of aggregates. $SiO_2/TiO_2$ multicomponent particles were generated in a hydrogen/oxygen coflow diffusion flame from two sets of precursors: TTIP (titanium tetraisopropoxide), TEOS(tetraethylorthosilicate). To maintain 1:1 mole ratio of TTIP:TEOS vapor theoretically, flow rate of carrier gas $N_2$ was fixed at 0.61pm for TTIP, at 0.11pm for TEOS. In situ sampling probe was used to supply particles into differential mobility analyzer(DMA) which was calibrated with using commercial DMA(TSI 3071A) and classifying monodisperse multicomponent particles. Classified particles were collected with electrophoretic collector. The distributions of composition from particle to particle were determined using EDS (energy dispersive spectrometry) coupled with TEM (transmission electron microscope). The chemical (atomic) compositions of classified monodisperse particle were obtained for different heights; z=40mm, 60mm, 80mm. The results suggested that the atomic composition of $SiO_2$ decreased with the height from burner surface and the composition of $SiO_2$ and $TiO_2$ approached to the value of 1 to 1 in far downstream. It is also found that the composition of $SiO_2$ decreases as the mobility diameter of aggregate increases.

  • PDF

Development and Performance Evaluation of Radial Exhaust Multi-port System for Real-time Particle Size Distribution Measurement (실시간 입자분포 측정을 위한 Radial Exhaust Multi-port System의 개발 및 성능평가)

  • Lee, Hong Ku;Lee, Yang-Woo;Jeon, Ki Soo;Ahn, Kang-Ho
    • Particle and aerosol research
    • /
    • v.9 no.3
    • /
    • pp.133-137
    • /
    • 2013
  • Measuring particle size distribution is one of the primary concerns in aerosol studies. For a nano-particle size distribution measurement, many scientists use a combination of a differential mobility analyzer (DMA) and a condensation particle counter (CPC) system, which is a called scanning mobility particle sizer (SMPS). Although it has a very high particle size resolution, some issues still remain. These problems include residence time between a DMA and a CPC, discontinuity of a CPC, and disturbance due to long scanning time during the precise measurement of particles. In particular, long scanning time is not adequate for measuring particle size distribution since the particle concentration is changing during the measurement. In this study, we developed radial exhaust multi-port system (REM-system) with no scanning time and high resolution to measure real-time particle size distribution. As a result of the REM-system performed using mono-disperse particle, it is expected that this system will be suitable for measuring continuously changing aerosol. If the counting efficiency of multi-condensation particle counter (M-CPC) and data inversion matrix are completed, REM-system will be a very adequate system for unsteady aerosol, which changes for SMPS scanning time.

Mass Prediction of Various Water Cluster Ions for an Accurate Measurement of Aerosol Particle Size Distribution (에어로솔 입자의 정밀입경분포 측정을 위한 물분자 클러스터 이온의 질량예측)

  • Jung, Jong-Hwan;Lee, Hye-Moon;Song, Dong-Keun;Kim, Tae-Oh
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.23 no.6
    • /
    • pp.752-759
    • /
    • 2007
  • For an accurate measurement of aerosol particle size distribution using a differential mobility analyser (DMA), a new calculation process, capable of predicting the masses for the various kinds of water cluster ions generated from a bipolar ionizer, was prepared by improving the previous process. The masses for the 5 kinds of positive and negative water cluster ions produced from a SMAC ionizer were predicted by the improved calculation process. The aerosol particle charging ratios calculated by applying the predicted ion masses to particle charging equations were in good accordance with the experimentally measured ones, indicating that the improved calculation process are more reasonable than the previous one in a mass prediction of bipolar water cluster ions.