• Title/Summary/Keyword: Particle Filters

Search Result 231, Processing Time 1.534 seconds

낮은 레이놀즈 수에서 두 개의 원형 실린더 주위 유동 및 입자 거동 해석 (Simulation of fluid flow and particle transport around two circular cylinders in tandem at low Reynolds numbers)

  • ;정석민;김동주
    • 한국입자에어로졸학회지
    • /
    • 제17권4호
    • /
    • pp.81-89
    • /
    • 2021
  • Understanding particle-laden flow around cylindrical bodies is essential for the better design of various applications such as filters. In this study, laminar flows around two tandem cylinders and the motions of particles in the flow are numerically investigated at low Reynolds numbers. We aim to reveal the effects of the spacing between cylinders, Reynolds number and particle Stokes number on the characteristics of particle trajectories. When the cylinders are placed close, the unsteady flow inside the inter-cylinder gap at Re = 100 shows a considerable modification. However, the steady recirculation flow in the wake at Re = 10 and 40 shows an insignificant change. The change in the flow structure leads to the variation of particle dispersion pattern, particularly of small Stokes number particles. However, the dispersion of particles with a large Stokes number is hardly affected by the flow structure. As a result, few particles are observed in the cylinder gap regardless of the cylinder spacing and the Reynolds number. The deposition efficiency of the upstream cylinder shows no difference from that of a single cylinder, increasing as the Stokes number increases. However, the deposition on the downstream cylinder is found only at Re = 100 with large spacing. At this time, the deposition efficiency is generally small compared to that of an upstream cylinder, and the deposition location is also changed with no deposited particles near the stagnation point.

보건용 마스크 초미세먼지 제거 성능 평가 및 재사용 연구 (Performance and reusability of certified and uncertified face masks)

  • 이해범;김서정;주흥수;조희주;박기홍
    • 한국입자에어로졸학회지
    • /
    • 제15권4호
    • /
    • pp.191-202
    • /
    • 2019
  • In this study, performance (particle removal efficiency and breathing resistance) of several commercially available face masks (electrostatic filter masks (KF80 certified), a nanofiber filter mask (KF80 certified), and an uncertified mask) with their filter structure and composition were evaluated. Also, effects of relative humidity (RH) of incoming air, water and alcohol exposure, and reusability on performance of face masks were examined. Monodisperse and polydisperse sodium chloride particles were used as test aerosols. Except the uncertified mask filter, PM2.5 removal efficiency was found to be higher than 90%, and the nanofiber filter mask had the highest quality factor due to the low pressure drop and high removal efficiency (nanofibers were arranged in a densely packed pore structure and contained a significant amount of fluorine in addition to carbon and oxygen). In the case of the KF80 certified mask, the removal efficiency was little affected when the RH of incoming air increased. When the mask filters were soaked in water, the removal efficiency of mask filters was degraded. In particular, the uncertified mask filter showed the highest removal efficiency degradation (26%). When the mask was soaked in alcohol, the removal efficiency also decreased with the greater degree than the water soaking case. The nanofiber mask filter showed the strongest resistance to alcohol exposure among tested mask filters. During evaluation of reusability of masks in real life, the removal efficiency of certified mask filter was less than 4% for 5 consecutive days (2 hours per day), while the removal efficiency of uncertified mask filter significantly decreased by 30% after 5 days.

가스 유입 방식에 따른 집진장치 내에서의 세라믹 캔들 필터로의 입자 부하 특성 비교 (Comparison of Particle Loading Characteristics onto Ceramic Candle Filters in Filtration System at Different Gas Inflow Pattern)

  • 박석주;임정환;임경수
    • Korean Chemical Engineering Research
    • /
    • 제46권5호
    • /
    • pp.983-987
    • /
    • 2008
  • IGCC 파일럿 플랜트의 집진시스템을 최적 설계하기 위하여 수치해석을 수행하였다. 서로 다른 가스 유입 방식이 집진용기 내부의 유체 유동장과 입자 거동에 미치는 영향을 분석하였다. 필터 표면에 전달되는 입자의 부하율은 분진입자가 혼합된 가스가 내부에 차단관이 설치된 집진용기의 외벽에 접하게 설치된 접선 유입구를 따라 집진용기 내로 유입되는 경우 아주 낮았으며, 입자크기가 클수록 입자부하율은 급격히 감소하였다. 이에 반하여, 가스 유동이 집진용기의 필터지지판 중앙에 수직하게 설치된 수직 유입구를 통하여 집진용기 내로 유입되는 경우, 필터 표면으로의 입자 부하율이 아주 높았으며, 입자크기 증가에 따른 입자부하율의 감소는 접선 유입 방식에 비하여 크지 않았다.

전자산업 청정실의 작업환경 및 유해물질농도 평가 (Assessment of hazardous substances and workenvironment for cleanrooms of microelectronic industry)

  • 정은교;박현희;신정아;장재길
    • 한국산업보건학회지
    • /
    • 제19권3호
    • /
    • pp.280-287
    • /
    • 2009
  • High-tech microelectronics industry is known as one of the most chemical-intensive industries. In Korea, Microelectronics industry occupied 38% of export and 16% of working employees work in microelectronics industry. But, chemical information and health hazards of high-tech microelectronics manufacturing are poorly understood because of rapid development and its penchant for secrecy. We need to investigate on chemical use and exposure control. We Site-visits to 6 high-tech microelectronics manufacturing company which have cleanroom work using over 1,000kg organic solvents (5 semi-conductor chips and its related parts company, 1 liquid crystal display (LCD)). We reviewed their data on chemical use and ventilation system, and measured TVOCs (Total Volatile Organic Compounds) and carbon dioxide concentration. All cleanroom air passed through hepa filters to acheive low particle levels and only 1 cleanroom uses carbon filters to minimize the organic solvents exposures In TVOC screening test, Cleanroom for semi-conductor chips and its related parts company with laminar down flow system (e.g. class 1~100) showed nondetectable level of TVOCs concentration, but Cleanroom for liquid crystal display (LCD) with conventional flow system (e.g. class 1,000~10,000) showed 327 ppm as TVOCs. Acetone concentration in cleanroom for Jig cleaning, LC Injection, Sealing processes were 18.488ppm (n=14), 49.762 ppm (n=15), 8.656 ppm (n=14) as arithmetric mean. Acetone concentration in cleanroom for LCD inspection process was 40ppm (n=55) as geometric mean, where the range was 7.8~128.7ppm and weakly correlated with ventilation rate efficiency(r=0.44, p<0.05). To control organic solvents in cleanrooms, chemical and carbon filters should be installed with hepa filters. Even though their volatile organic compounds concentration was not exceed to occupational exposure limits, considering of entrance limited cleanroom environment, long-term period exposure effects and adverse health effects of cleanroom worker need further reseach.

압전체 기판에서의 에너지 포획 (Energy Trapping in the piezoelectric Substrate)

  • 이개명;박창엽
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1995년도 추계학술대회 논문집
    • /
    • pp.34-39
    • /
    • 1995
  • Particle displacement distributions of the fundamental mode and overtone modes in an energy-frapped single resonator and an energy-trapped double acoustically coupled filter using the thickness shear vibration were calculated. And the effects of the width of a pair of partial electrodes, the width of the gap between two pairs of partial electrodes and the magnitude of the plate back on the displacement distributions of the symmetric vibration mode and anti-symmetric vibration mode of the resonators and the filters were investigated.

  • PDF

춘천에서 2002년 봄철 황사 발생기간 동안에 채취된 미세분진 중 무기성분의 특성 (Characteristics of Inorganic Components in Fine Particles Collected at Chunchon during the Springtime Yellow Sand Occurrence Period in 2002)

  • 김희갑;정경미;김동진;이종태
    • Environmental Analysis Health and Toxicology
    • /
    • 제17권4호
    • /
    • pp.333-339
    • /
    • 2002
  • Yellow sand (YS) storms were observed about ten times in the Korean peninsula during March and April in 2002. Twenty four hour fine particle (PM$\_$2.5/) samples were collected onto the 47 mm Teflon - coated quartz filters over 9 days during and after the events using the MiniVol Portable Air Sampler at a flow rate of 5 liters per minute. The highest PM$\_$2.5/ concentration measured during the YS period was 289 $\mu\textrm{g}$/㎥, which is 13 times higher than the lowest of the values for the samples collected during the non-yellow sand period. The filter samples were analyzed for inorganic ions using the IC, AAS and Autoanalyzer, and for metals using the ICP-MS. The results showed that the concentrations of some inorganic ions (e.g., Ca$\^$2+/ and SO$_4$$\^$2-/) and metals (e.g., Fe, Mn) of soil origin were elevated during the yellow sand events.

Filler metal을 이용한 Stainless steel필터의 제조 및 통기도 (Fabrication and Permeability of Stainless Steel Filter by using Filler Metal)

  • 배승열;안인섭;성택경;최주호
    • 한국분말재료학회지
    • /
    • 제11권4호
    • /
    • pp.288-293
    • /
    • 2004
  • The application concept of using a fail safety filter on the filtering system is to prevent the particle leakage when the main filter element is broken at high temperature. In this study, the metal filters were fabricated by pressureless sintering method. The mixture of stainless steel powders and filler metal binder solved in the water solutions of 5% PVA was compacted to form the cylindrical filter without pressure. The compacted filter were sintered in the vacuum sintering furnace at 120$0^{\circ}C$ for 1 hour. The metal filter(produced with powder of 640-840 ${\mu}m$ size) having more than above 50% porosity, 500${\mu}m$ pore size, and permeability of 7.3${\times}$10$^{-11}$m$^{2}$ plugged within 2.5 minute to prevent the leakage of maximum slip particle size of less than 3${\mu}m$.

단일 전하로 하전된 단일 섬유에서의 미세입자의 초기 집진효율에 관한 이론적 연구 (A Theoretical Study on the Initial Collection Efficiency of Submicron Particles by a Unipolar Charged Fiber)

  • 오용학;전기준;정용원
    • 한국대기환경학회지
    • /
    • 제17권3호
    • /
    • pp.259-268
    • /
    • 2001
  • In this study, we have developed a simulation method to predict the initial collection efficiency of a unipolar charged fiber in the electret filters. The particle sizes considered were in the submicron range and thus Brownian motion of particles was also taken into consideration along with electrostatic forces acting on the particles. The simulation results were compared with other investigators experimental data on single fiber efficiency as well as with the calculated results using the existing correlations on single fiber efficiency. It has been shown that simulation results are in good agreement both with the experimental data with those predicted by the correlations.

  • PDF

직접 분사식 가솔린 인젝터 분무의 입경 측정에 형광/산란광법의 적용 (Application of Fluorescence/Scattering Technique to the Measurement of Spray Droplet Size in GDI Injector)

  • 곽수민;류경훈;최동석;김덕줄
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.353-358
    • /
    • 2000
  • To achieve the requirement for high fuel economy and low emissions, the research for GDI engines is recently very brisk in the whole world. This study was performed to measure distribution of average particle size in non-evaporating spray. The 2-D fluorescence/scattering images of fuel spray were captured simultaneously by visualization system composed of a laser sheet, a doubling prism, optical filters, and an ICCD camera. Using the ratio of the two light intensities, particle size distribution was obtained. The SMD measured by fluorescence/scattering technique was compared with it obtained by PDA. The experimental results show that the spray structure of GDI injector and temporal SMD distribution.

  • PDF