• Title/Summary/Keyword: Particle Collection

Search Result 307, Processing Time 0.027 seconds

Numerical Analysis of Nonlinear Shoaling Characteristics over Surf Zone Using SPH and Lagrangian Dynamic Smagronsky Model (Lagrangian Dynamic Smagronsky 난류모형과 SPH를 이용한 쇄파역에서의 비선형 천수거동에 관한 연구)

  • Cho, Yong-Jun;Lee, Heon
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.19 no.1
    • /
    • pp.81-96
    • /
    • 2007
  • Nonlinear shoaling characteristics over surf zone are numerically investigated based on spatially averaged NavierStokes equation. We also test the validity of gradient model for turbulent stresses due to wave breaking using the data acquainted during SUPERTANK LABORATORY DATA COLLECTION PROJECT(Krauss et al., 1992). It turns out that the characteristics length scale of breaking induced current is not negligible, which firmly stands against ever popular gradient model, ${\kappa}-{\varepsilon}$ model, but favors Large Eddy Simulation with finer grid. Based on these observations, we model the residual stress of spatially averaged NavierStokes equation after Lagrangian Dynamic Smagorinsky(Meneveau et al., 1996). We numerically integrate newly proposed wave equations using SPH with Gaussian kernel function. Severely deformed water surface profile, free falling water particle, queuing splash after landing of water particle on the free surface and wave finger due to structured vortex on rear side of wave crest(Narayanaswamy and Dalrymple, 2002) are successfully duplicated in the numerical simulation of wave propagation over uniform slope beach, which so far have been regarded very difficult features to mimic in the computational fluid mechanics.

Experimental study and Verification of Fine Particles and Gaseous Pollutants Removal on Water-cyclone System (Water-cyclone 장치의 미세입자, 기체상 오염 물질 처리 방법 연구 및 실험적 검증)

  • Kwon, Sung-An;Lee, Sang-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.17 no.1
    • /
    • pp.15-19
    • /
    • 2014
  • Recently, cyclone is used to collect fine particles in various industrial precesses, but many studies are undergoing because of cyclone's low collection efficiency. Thus, we have developed water-cyclone which minimizes disadvantages of existing conventional cyclone and designed 3 different stages depending on precessing materials. Stage 1 collects particles by using principles of conventional cyclone. Stage 2 processes acid gases by extending contact time with water film through vortex movement. Stage 3 processes uncollected substances in stage 1 and 2. Hence, we evaluate water-cyclone by experimental verification.

Size Classification of Airborne Nanoparticles Using Electrically Tunable Virtual Impactor (전기적으로 분류 입경의 제어가 가능한 가상 임팩터을 이용한 대기 중 나노 입자의 분류)

  • Kwon, Soon-Myung;Kim, Yong-Ho;Park, Dong-Ho;Hwang, Jung-Ho;Kim, Yong-Jun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.2
    • /
    • pp.118-125
    • /
    • 2009
  • This paper reports the size classification of nanoparticles as well as electrical tuning techniques for the cut-off diameter and collection efficiency. Classifying particles < 100 nm in diameter is quite a technical challenge using a virtual impactor with the cut-off diameter being determined geometrically. However, the proposed virtual impactor can classify particles <100 nm and tune the cut-off diameter by electrically accelerating the particles. The cut-off diameter of the proposed device was tuned from 15 to 50nm.

Effect of Charging on Particle Collection during Synthesis of Nanoparticles by Pulse Plasma (펄스 플라즈마에 의한 나노입자 제조 시 하전이 입자의 포집에 미치는 영향)

  • Kim, Kwang-Su;Kim, Tae-Sung
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.210-214
    • /
    • 2007
  • Silicon nanoparticles are widely studied as a material with great potential for wide applications. For application to present industry, it should be easy to control the characteristics of nanoparticle including the size and structure. In this paper, we investigated the formation of Si nanoparticle using pulse plasma technology. Plasma technology is already quite common in device industry and the size of nanoparticle can be easily controlled according to plasma pulse duration. An inductively-coupled plasma chamber with RF power (13.56 MHz) was used with DC-biased grid $(-200\sim+200\;V)$ installed above the substrate. In order to measure the shape and size of nanoparticle, TEM was used. It was found that the size of nanoparticles can be controlled well with the plasma pulse duration and the collection efficiency is increased with the use of either negative or positive DC-bias.

  • PDF

Experimental and Finite Difference Method(FDM) Analysis on Collection Characteristics of Electrostatic Precipitator (전기집지기 집진특성 실험 및 유한차분해석에 관한 연구)

  • 김용진;홍원석;최헌오;함병훈;민춘식;유기선
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.1
    • /
    • pp.49-56
    • /
    • 1994
  • Electrostatic Precipitators( EP ) are widely used in industry for controlling the emission of particulate pollutant Recently, a number of researches have been conducted to solve performance and reliability problems of EP, As a result of researches in the laboratory and of pilot scale, a technology of wide-pitch-spacing has been successfully applied to full scale units. It has been known that the wide-pitch-spacing can reduce the capital cost of newly installed precipitators, and the cost of rebuilding existing uints. In this paper, a systematic study was performed to develop a wide-pitch electrostatic precipitator. The study includes experimental and numerical work on the following : Particle collection characteristics for a bench-scale unit; gas flow characteristics( temperature and velocity distributions): other EP operating variables such as electric Power supply/control. The results are applied directly to design of wide-pitch-spacing EP and the developed numerical model was found to be a good argreement with the experimental results. The EHD simulation program is necessary to design the high efficiency EP.

  • PDF

The Analysis of Inflowing Sediments Behavior around the Sandbar in Nakdong River Estuary (낙동강 하구역 사주 주변에서의 퇴적물질의 유압거동 해석)

  • KIM KYUNG-HOI;LEE IN-CHEOL
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.133-136
    • /
    • 2004
  • In-situ collection experiments were performed to analyze inflowing sedilnents behavior as a basic study of topographical change in Nakdong River Estuary. Sediment rate and bed load flux ranged from 0.0004 to $0.472\;g/cm^2/day\;and\;0.0005\~1.7579\;g/cm^2/day$, respectively. The settling velocity of suspended particulate matter was estimated in tire range of $0.339\~1.010\;cm/sec$, The grain size analysis shows that surface sediments in backside of sandbar and bed load in front of dike have a similar grain size distribution. It is considered that the source of surface sediments in backside of sandbar were flowed in from Nakdong River. In order to verify the characteristics of inflowing sediments behavior, detailed surveys around Nakdong River Estuary need to be carried out, continuously.

  • PDF

Effects of Aperture Densitv Distribution on the Flow Through a Rock Fracture with Line-Source and Line-Collection

  • Park, Chung-Kyun;Hahn, Pil-So
    • Nuclear Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.485-495
    • /
    • 1998
  • Migration characteristics of tracers in a rock fracture in a case of line-source and line-collection was studied. The fracture plane was discretized into a square mesh to which variable apertures were assigned. The spatially varying apertures of a fracture were generated using a geostatistical method, based on a given aperture probability density distribution and a specified spatial correlation length. The flow potential and pressure at each node were computed. Calculations showed that fluid flow occurs predominantly through a few preferred paths. Hence, the large range of apertures in the fracture gives rise to flow channeling. The solute transport was calculated using a particle tracking method. The migration plumes of tracer between injection line and withdrawal line are displayed in contour plots. The elution curves are shown to be controlled by the aperture density distribution and to be insensitive to statistical realization and spatial correlation length.

  • PDF

Characterization of Fine Dust Collection Using a Filter Ventilation (환기장치와 필터를 활용한 미세먼지 제거특성 조사)

  • Jeon, Tae-Yeong;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.26 no.2
    • /
    • pp.229-233
    • /
    • 2015
  • In this study, we examined the removal characteristics of suspended particulate matters which are one of carcinogens to cause lung cancer. The fine dust capture by a pilot scale filtration system depends on several important variables such as humidity, initial fine dust injection volume, and flow rate. The average concentration of particulate matters in the test chamber decreased, but the ultimate collection efficiency did not change during the filtration under high humidity, compared to those of using ambient conditions The initial injection amount of fine dust did not influence the particle capturing efficiency. When the flow rate reduced from 0.6 m/s to 0.3 m/s, the dust collection time increased approximately 1.4 times. Among all variables tested, the flow rate showed the most significant effect on the removal efficiency of fine particulate matter.

Filtration Performance of Fibrous Air Filter under External Electric Field using Insulated Electrodes (외부전기장 적용 섬유상 에어필터의 절연 전극 사용에 따른 여과특성)

  • Ji, Sung-Mi;Sohn, Jong-Ryeul;Park, Hyun-Seol
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.6
    • /
    • pp.675-687
    • /
    • 2012
  • Applying an external electric field across air filter media is one of methods to improve the filtration performance. Metal wire meshes have been commonly used as electrodes situated on both sides of a thick filter pad. For a thin filter medium a short circuit, known as the biggest drawback for applying an external electric field to air filter, can occur at the closest point between electrodes. In this study several types of insulated meshes were prepared by coating #50 meshes with a dielectric material, Nylon 66, and the filtration property of air filter was evaluated at the presence of external electric field using those insulated meshes as electrodes and compared with that of filters using bared meshes. The collection efficiency of tested filter was increased from 78% to 95% for singly charged 100 nm particles by application of external electric field. As a result, there was no significant difference in collection efficiency between filters with insulated and bared electrodes. Similar results could be also seen from the tests using polydisperse particles. Finally, through this study, we found that the insulation of mesh electrodes doesn't affect the filtration performance of fibrous air filter under external electric field.

A Study on the Electrostatic Precipitation of Auto-Bias Type by Corona Discharge (코로나방전에 의한 AUTO-BIAS형태의 전기집진에 관한 연구)

  • 이주상;김신도;김광영
    • Journal of environmental and Sanitary engineering
    • /
    • v.10 no.2
    • /
    • pp.79-88
    • /
    • 1995
  • The electrostatic precipitation of Auto- Bias has the advantages of a little of power consumption by the voltage to apply only at ionizer and the prevention of fire danger by current flow over. As this ionizer wire was used WXN- Pt material of diameter 90$\mu $m, that improved ion efficiency and safety, simplified a existing source of electric power by induced Auto- Bias voltage. Also, the new type collector used electric conductivity- film wag superior a electric safety and dust collection efficiency and was possible to wash it by water. As a experiment result of this Auto- Bias electrostatic collector, the induced Auto- Bias voltage by appling D.C 4.0∼6.0kV at ionizer was 1.3∼2.3kV and then the power consumption by applied voltage was 8- l8W. The pressure loss of collector by the amount of flowing was 6.1 OmmH$_{2}$O in 300m$^{3}$/hr and showed a safe state of the dust collection. The collection efficiency by particle size was 65.1-95.8% in 0.5∼5.0$\mu $m. After corona discharge of ionizer, the remains ozone concentration was found much lower than that of ACGIH or air pollution criteria in Korea.

  • PDF