• Title/Summary/Keyword: Particle Collection

Search Result 307, Processing Time 0.023 seconds

Comparisons of Dust Collection Efficiency on the Tangental Entry and Axial-vane Type Cyclone (접선유입식과 축상유입식 사이클론의 집진효율 비교)

  • Yi, Chung-Seob;Lee, Chi-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.10 no.6
    • /
    • pp.115-121
    • /
    • 2011
  • This study is about comparison of tangental entry type cyclone dust collector with axial vane type cyclone dust collector. Cut diameter and dust collection efficiency of both collector was compared by theory and experiment. Cut diameter was calculated by an quasi-empirical formula by Lapple and Shepherd. Measurement of cut diameter was conducted by particle counter through dust generator. As the result, cut diameter obtained by experiment was a little larger than that by theory. But the error is within $0.5{\mu}m$ in both type of collector, so it could be confirmed that theoretical value and experimental value were almost identical. And, as flow rate increased, dust collection efficiency was increased. Also axial vane type showed higher dust collection efficiency than tangental entry type. Therefore, it can be said that axial vane type cyclone dust collector has higher performance than the other.

Study on the optimal design of floor exhaust system using computational fluid dynamics for subway platform (수치해석을 활용한 승강장 바닥배기 시스템 최적화 연구)

  • Namgung, Hyeong-Gyu;Park, Sechan;Kim, Minhae;Kim, Soo-Yeon;Kwon, Soon-Bark
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.443-449
    • /
    • 2017
  • The imbalance of air supply and the exhaust on subway platforms has led to the installation of platform screen doors in underground subway stations. This imbalance causes the accumulation of pollutants on the platform and loss of comfort due to the lack of ventilation. In this study, a floor exhaust system was optimized using computational fluid dynamics (CFD) and an optimization program. The optimized floor exhaust system was manufactured and tested experimentally to evaluate the particle collection efficiency. CFX 17.0 and HEEDS were used to analyze the flow field and optimize the principal dimensions of the exhaust system. As a result of the three-step optimization, the optimized floor exhaust system had a total height of 1.78 m, pressure drop of 430 Pa, and particle collection capability of 61%. A fine dust particle collection experiment was conducted using a floor exhaust system that was manufactured at full scale based on the optimized design. The experiment indicated about 65% particle collection efficiency. Therefore, the optimized design can be applied to subway platforms to draw in exhaust air and remove particulate matter at the same time.

Optimal Design of Vacuum Cleaner with a Multi Cyclone (멀티사이클론을 이용한 진공청소기의 최적설계에 관한 연구)

  • Ha, Gun-Ho;Kim, Eung-Dal;Yang, Byung-Sun;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.2
    • /
    • pp.126-131
    • /
    • 2011
  • Cyclone, a type of particle collector widely used in the field of ambient sampling and industrial particulate control, is the principal type of gas-solids separator that uses a centrifugal force. The goal of this study is to design and evaluate the cyclone that can be used for the household vacuum cleaners. A multi cyclone with a 1st cyclone and several 2nd cyclones is designed to improve dust collection efficiency. The dust collection efficiency and the suction power of 1st cyclone are evaluated. And the dust collection efficiency and the suction power of multi cyclone are evaluated according to various sizes of inlet and vortex finder. As a result, a cone shape porous filter has better dust collection efficiency than a cylinder shape porous filter. The dust collection efficiency of a multi cyclone is 3.5% greater than that of a single cyclone.

Particle Agglomeration of a Bipolar Charging System with a Control Grid (제어전극을 갖는 쌍극성 하전장치의 입자응집 특성)

  • Moon, Jae-Duk;Ahn, Chang-Jin
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.10
    • /
    • pp.465-470
    • /
    • 2005
  • In this paper. an experimental study, for method of increasing the efficiency of electrostatic precipitator for the collection of submicron-sized particles has been studied. All AC electric field was used to induce agglomeration of bipolory charged Particles. .4 bipolar AC-agglomeration system. consisted with a multineedle-mesh discharge system with a control grid, was proposed and investigated. Systematic experiments were carried out to investigate the agglomeration ratio of the AC-agglomeration system as a function of the different grid spacings and grid resistances for the submicron particles generated from liquid prorhane gas burning. The agglomeration ratios, which indicate the particle numbers before and after agglomeration of the test particles in number concentration base, were found to be 0.87, 1.80, 3.86, 9.50 and, 11.00 times for the particle sizes of 0.3. 0.5, 0.7, 1.0, and 2.0$\mu$m at applied voltage of 3.5kV, respectively which showed that the fine particle numbers were decreased while the larger particle numbers were increase greatly.

Experimental Study on the Discharge Electrode of A Two-Stage Electrostatic Air Cleaner (2단 평행판 전기집진기의 방전부 특성 실험)

  • Kim, I.S.;Lee, J.O.;Kim, Y.J.;Choi, H.O.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.5 no.1
    • /
    • pp.27-34
    • /
    • 1993
  • The two-stage electrostatic air cleaner is a particle control device that uses electrical forces to move particles in the flowing gas stream onto collector plates. Despite a general understanding of electrostatic air cleaner operation and their successful use in industry, many questions regarding flow, electric fields and particle collection have remained unanswered. In this paper, an experimental investigation for designing the discharge electrode, including ionizer wire diameter, plate length and wire-to-plate spacing, is carried out. The electrical conditions, namely the electric field intensity, the space current and the particle charge intensity, in wire-plate electrostatic air cleaner are reported and examined.

  • PDF

A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels (도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구)

  • Koo, Tae Yong;Kim, Yong Min;Hong, Jung Hee;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.79-87
    • /
    • 2013
  • In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-${\varepsilon}$ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.

A Study on the Formation Mechanism of the Fly Ash from Coal Particles in the Coal Burning Boiler (석탄연소 보일러에서 생성된 석탄회의 분석과 형성 메커니즘 해석에 대한 연구)

  • Lee, Jung Eun;Lee, Jae Keun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.12
    • /
    • pp.1691-1701
    • /
    • 1998
  • Fly ash produced in coal combustion is a fine-grained material consisting mostly of spherical, glassy, and porous particles. A study on the formation mechanism of the fly ash from coal particles in the pulverized coal power plant is investigated with a physical, morphological, and chemical characteristic analysis of fly ash collected from the Samchonpo power plant. This study may contribute to the data base of domestic fly ash, the improvement of combustion efficiency, fouling phenomena and ash collection in the electrostatic precipitator. The physical property of fly ash is determined using a particle counter for the measurement of ash size distribution. Morphological characteristic of fly ash is performed using a scanning electron micrograph. The chemical components of fly ash are determined using an inductively coupled plasma emission spectrometry(ICP). The distribution of fly ash size was bi-modal and ranged from 12 to $19{\mu}m$ in mass median diameter. Exposure conditions of flue gas temperature and duration within the combustion zone of the boiler played an important role on the morphological properties of the fly ash such as shape, particle size and chemical components. The evolution of ash formation during pulverized coal combustion has revealed three major mechanisms by large particle formation due to break-up process, gas to particle conversion and growth by coagulation and agglomeration.

Dust Collection Characteristics of Multi-layer Multi-stage Porous Plate System with Ionizer and Dielectric-substance (이오나이저 및 유전체 방식을 도입한 다층 다단 다공성 플레이트 시스템의 집진특성)

  • Yoa, Seok-Jun
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.63-72
    • /
    • 2013
  • The main purpose of this study is to analyze the collection characteristics of multi-layer multi-stage porous plate system with ionizer and dielectric-substance experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with experimental parameters such as applied voltage, inlet velocity, stage number and inlet particle concentration, etc. In results, for multi-layer multi-stage porous plate system of inflow type, at 5 stage and $v_{in}$=2.58 m/s, the pressure drop becomes lower 15 $mmH_2O$ as 95 $mmH_2O$ than that of non-inflow type system. It is estimated that for the present system with ionizer and dielectric-substance, the collection efficiency represents 98.5% showing higher 5.2% comparing to that of multi-layer multi-stage porous plate system without ionizer and dielectric-substance at 5 stage, $v_{in}$=2.58 m/s and inlet concentration $3g/m^3$(fly ash).

Fine Particle Removal by a Vehicle Air Cleaner (차량용 에어클리너의 미세입자 제거특성)

  • Park, Byung-Hyun;Kim, Sang-Bum;Kim, Gyung-Soo;Lee, Sang-Ryul;Lee, Myong-Hwa
    • Journal of ILASS-Korea
    • /
    • v.12 no.2
    • /
    • pp.86-93
    • /
    • 2007
  • There is a growing interest to develop an eco-friendly air cleaner with high performance through a remanufacturing process. Two kinds of polyurethane filter media, a coarse (Filter-A) and a fine filter media (Filer-B), are used in this study to protect a vehicle engine from airborne particles. In order to improve the collection performance of the filters (Filter-A, Filter-B), an oil coating technology on the filter surface was introduced. As a result, inertial force is a dominant collection mechanism for a dry filter media, so that collection efficiency increases with increasing filtration velocity. However, intra-structure change of an oil-coated filter media influences on the collection mechanism, which shows a non-linear collection efficiency curve in terms of filtration velocity. The result shows that the developed filter media are eco-friendly and effective to protect a vehicle engine from airborne particles especially at low filtration velocity.

  • PDF

Collection Characteristics of Wet-type Multi-layered and Multi-staged Porous Plate System (습식 다층 다단 다공성 플레이트 시스템의 집진특성)

  • Yoa, Seok-Jun;Kim, Joo-Yeon
    • Journal of Power System Engineering
    • /
    • v.18 no.3
    • /
    • pp.42-50
    • /
    • 2014
  • The main object of this study is to investigate the collection characteristics of wet-type multi-layered and multi-staged porous plate system experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as water spray, inlet velocity, stage number and inlet particle concentration, etc. In results, for the present system of wet-type, the pressure drop represents 158 $mmH_2O$ higher 3% than that in dry-type at 5 stage and $v_{in}$=3.53 m/s. In case of 5 stage, $v_{in}$=3.53 m/s and water spray 250 ml/min, the collection efficiency of the present system becomes significantly higher as 99.7% comparing to that of the conventional wet-type scrubber. Additionally, for 5 stage and 250 ml/min, $SO_2$ removal efficiencies decrease with the increment of inlet velocity representing 75.0, 62.5, 50.0%, at $v_{in}$=2.12, 2.82, 3.53 m/s, respectively.