Abstract

The main object of this study is to investigate the collection characteristics of wet-type multi-layered and multi-staged porous plate system experimentally. The experiment is carried out to analyze the characteristics of pressure drop and collection efficiency for the present system with the experimental parameters such as water spray, inlet velocity, stage number and inlet particle concentration, etc. In results, for the present system of wet-type, the pressure drop represents 158 $mmH_2O$ higher 3% than that in dry-type at 5 stage and $v_{in}$=3.53 m/s. In case of 5 stage, $v_{in}$=3.53 m/s and water spray 250 ml/min, the collection efficiency of the present system becomes significantly higher as 99.7% comparing to that of the conventional wet-type scrubber. Additionally, for 5 stage and 250 ml/min, $SO_2$ removal efficiencies decrease with the increment of inlet velocity representing 75.0, 62.5, 50.0%, at $v_{in}$=2.12, 2.82, 3.53 m/s, respectively.

Keywords

References

  1. M. Y. Chun, E. S. Shin, B. W. Kang, G. U. Kang and D. G. Kim, 2010, "Air pollution prevention technology", Dong Hwa Technology, Seoul, pp. 327-333.
  2. J. H. Koo, M. C. Kim, S. C. Park, T. S. Park, B. G. Ahn, S. W. Oh, G. S. Lee and S. J. lee, 2006, "Atmosphere Environmental Device Design II", Dong Hwa Technology, Seoul, pp. 226-233.
  3. J. S. Kim et al., 2004, "Air pollution prevention technology(latest) Series 6(Environment)", Dong Hwa Technology, Seoul, pp. 281-336.
  4. G. R. Lee, J. H. Bae, G. H. Song, G. H. lee, J. H. Lee and G. H. Lim, 2001, "Environmental Engineering(latest)", Dong Hwa Technology, Seoul, pp. 226-233.
  5. D. G. Kim, 2008, "Removal Characteristics of Air Pollutants using Wet type Multi-stage Porous Plate System", MS Thesis, Pukyong National University, Busan, Korea.
  6. S. J. Yoa and D. K. Kim, 2007, "Collection Characteristics of Wet Type Multi-stage Porous Plate System for Dust Removal under Tunnel Construction", The 2007 Environmental Societies Joint Conference, pp. 1781-1784.
  7. S. J. Yoa and Y. S. Joa, 2006, "Collection Characteristics of Multi-stage Porous Plate System with Water Spray", Spring Environmental Societies Conference, pp. 706-713.
  8. I. K. Kim and S. J. Yoa, 2010, "Collection Characteristics of Multi-layer Multi-stage Porous Plate System", Journal of the Korean Society of for Power System Engineering, Vol. 14, No. 5, pp. 10-16.
  9. J. M. Suh, J. Y. Ryu, W. T. Lim, M. S. Jung, J. H. Park and C. H. Shin, 2010, "Prediction of the Efficiency of Factors Affecting Pressure Drop in a Pulse Air Jet-type Bag Filter", Journal of the Environmental Sciences, Vol. 19, No. 4, pp. 437-446. https://doi.org/10.5322/JES.2010.19.4.437
  10. J. K. Yeom, 2013, "A Study of Numerical Analysis on Wall Impinging Spray", Journal of the Korean Society for Power System Engineering, Vol. 17, No. 2, pp. 21-28. https://doi.org/10.9726/kspse.2013.17.2.021
  11. S. J. Yoa, 2013, "Dust Collection Characteristics of Multi-layer Multi-stage Porous Plate System with Ionizer and Dielectric-substance", Journal of Korean Society for Power System Engineering, Vol. 17, No. 6, pp. 63-72.
  12. Y. O. Park, H. J. Park and Y. H. Kim, 2011, "$SO_2$ Removal by Internal Circulation of de-SOx Absorbents", Journal of Korean Society for Atmospheric Environment, Vol. 27, No. 6, pp. 672-680. https://doi.org/10.5572/KOSAE.2011.27.6.672
  13. H. M. Yang and S. S. Kim, 2000, "An Experimental Approach to Evaluate the Desulfurization Yield in Spray Drying Sorber.", Transactions of the Korean Society of Mechanical Engineers-B, Vol. 24, No. 4, pp. 589-598.
  14. W. H. Koo, S. D. Kim, S. I. Dong, J. K. Na and J. H. Hong, 1993, "A Study on $SO_2$ Removal Variation According to Air Pressure in Semi-Dry Scrubber", Environmental Societies Conference, pp. 373-376.

Cited by

  1. A study on the efficiency of pollution control using the scrubber with a spiral filter and a cyclone system for decreasing particulate matter and odor inducing compounds vol.18, pp.2, 2019, https://doi.org/10.15250/joie.2019.18.2.112