• Title/Summary/Keyword: Partial volume effect

Search Result 115, Processing Time 0.029 seconds

Analysis of Acquisition Parameters That Caused Artifacts in Four-dimensional (4D) CT Images of Targets Undergoing Regular Motion (표적이 규칙적으로 움직일 때 생기는 4DCT 영상의 모션 아티팩트(Motion Artifact) 관련된 원인분석)

  • Sheen, Heesoon;Han, Youngyih;Shin, Eunhyuk
    • Progress in Medical Physics
    • /
    • v.24 no.4
    • /
    • pp.243-252
    • /
    • 2013
  • The aim of this study was to clarify the impacts of acquisition parameters on artifacts in four-dimensional computed tomography (4D CT) images, such as the partial volume effect (PVE), partial projection effect (PPE), and mis-matching of initial motion phases between adjacent beds (MMimph) in cine mode scanning. A thoracic phantom and two cylindrical phantoms (2 cm diameter and heights of 0.5 cm for No.1 and 10 cm for No.2) were scanned using 4D CT. For the thoracic phantom, acquisition was started automatically in the first scan with 5 sec and 8 sec of gantry rotation, thereby allowing a different phase at the initial projection of each bed. In the second scan, the initial projection at each bed was manually synchronized with the inhalation phase to minimize the MMimph. The third scan was intentionally un-synchronized with the inhalation phase. In the cylindrical phantom scan, one bed (2 cm) and three beds (6 cm) were used for 2 and 6 sec motion periods. Measured target volume to true volume ratios (MsTrueV) were computed. The relationships among MMimph, MsTrueV, and velocity were investigated. In the thoracic phantom, shorter gantry rotation provided more precise volume and was highly correlated with velocity when MMimph was minimal. MMimph reduced the correlation. For moving cylinder No. 1, MsTrueV was correlated with velocity, but the larger MMimph for 2 sec of motion removed the correlation. The volume of No. 2 was similar to the static volume due to the small PVE, PPE, and MMimph. Smaller target velocity and faster gantry rotation resulted in a more accurate volume description. The MMimph was the main parameter weakening the correlation between MsTrueV and velocity. Without reducing the MMimph, controlling target velocity and gantry rotation will not guarantee accurate image presentation given current 4D CT technology.

Review of outcomes of using lower ethanol concentration (83%) in percutaneous ultrasound-guided renal cyst sclerotherapy in dogs

  • Sanghyeon Yoon;Jungmin Kwak;Deokho Im;Hakyoung Yoon
    • Journal of Veterinary Science
    • /
    • v.24 no.5
    • /
    • pp.61.1-61.12
    • /
    • 2023
  • Background: Percutaneous renal cyst sclerotherapy (PRCS) as a treatment for renal cysts is usually performed with a high concentration of ethanol (≥ 90%). This study reviewed cases in which a lower concentration of ethanol (83%) was used for the procedure in dogs. Methods: Records of cases of renal cysts treated by sclerotherapy using 83% ethanol in dogs were reviewed. Outcomes of the treatment were evaluated by comparing volumes of renal cysts before the procedure and the volumes after treatment, using ultrasound images with the volume reduction rates classified as follows: < 50% of initial volume (failed); ≥ 50% but < 80% of initial volume (partial success); ≥ 80% but < 95% of initial volume (great success); ≥ 95% of initial volume (complete success). Results: Out of nine dog kidneys, renal cysts sclerotherapy with 83% ethanol achieved partial success in one kidney, great success in four, and complete success in the other four. No side effect was observed. The mean of the volume-reduction rates was 90.00 ± 11.00 while the minimum and maximum reduction rates were 65% and 100%, respectively. Conclusions: The lower ethanol concentration (83%) is good for disinfecting kidneys in PRCS.

Development of a Smooth Colon Surface Restoration Method for Electronic Colon Cleansing (전자적 장세척을 위한 부드러운 장표면 복원 방법 개발)

  • Kim, Seung-Hwan;Kim, Dong-Sung
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.3
    • /
    • pp.251-256
    • /
    • 2011
  • Virtual colonoscopy is favored over conventional colonoscopy because its non-invasive procedure can avoid complications that may happen in a conventional approach and because it can cleanse colon electronically instead of uncomfortable conventional colon cleansing. Electronic Colon Cleansing(ECC) has to deal with not only removing tagged fecal material but also recovering Partial Volume Effect(PVE) due to tagging material. This paper proposes an ECC method restoring inherent natural PVE while previous approaches focused only on reducing PVE due to tagged fecal material. The proposed method reduces PVE using 3-dimensional adaptive density correction and then replaces tagged fecal material into air. Next, it generates natural PVE for the replaced air adjacent to soft tissue and finally makes smooth transition of gray values for soft tissue adjacent to the replaced air. The proposed method applied to eleven patient data, and showed promising results.

A Study on the Feasibility of Partial Penetration Laser Welding for the Lap Joint of 390MPa High Strength Steel Sheets (390MPa급 고장력강판의 경치기 레이저 용접에서 부분용입 용접의 적용 가능성에 대한 연구)

  • 이경돈;박기영;김주관
    • Journal of Welding and Joining
    • /
    • v.20 no.2
    • /
    • pp.95-101
    • /
    • 2002
  • After high power lasers are avaliable in the commercial market, the number of applications of the laser welding has been increased in manufacturing industries. Although the tailored blank laser welding of butt jointed steel sheets is well known recently in the automotive industries, the lap joint laser welding is a new technology to the automotive manufacturing people as well as the design people. But the deep penetration laser welding seems to be preferred to the partial penetration welding for the lap joint welding in the automotive manufacturers because the partial penetration is a serious deflect for the butt joint. In this study, the feasibility of partial penetration welding fur the lap joint $CO_2$ laser welding was studied fur the 1mm thick 390MPa high strength steel sheets for automotive bodies. The process window of the lap joint partial penetration welding was obtained from experiments with the gap size and the welding speed as process parameters. The partial penetration welding was found excellent on the basis of the tensile shear strength and sectional geometry. The bead width, input energy Per volume, tensile-shear strength, deformation energy and the sectional geometries after tensile-shear tests of partial penetration welded specimens are compared with those of full penetration welded specimens with a series of gaps and welding speeds.

Study of the seroma volume changes in the patients who underwent Accelerated Partial Breast Irradiation (부분유방방사선치료(Accelerated Partial Breast Irradiation) 환자의 장액종(Seroma) 체적 변화에 대한 연구)

  • Kim, Dae Ho;Son, Sang Jun;Mun, Jun Ki;Seo, Seok Jin;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.65-75
    • /
    • 2016
  • Purpose : By analyzing seroma volume changes in the patients who underwent Partial breast radiation therapy after breast conserving surgery, we try to contribute to the improvement of radiotherapy effect. Materials and Methods : Enrolled 20 patients who underwent partial breast radiation therapy by ViewRay MRIdian System were subject. After seeking for the size of the removed sample in the patients during surgery and obtained seroma volume changes on a weekly basis. On the Basis of acquired volume, it was compared with age, term from start of the first treatment after surgery, BMI (body mass index) and the extracted sample size during surgery. And using the ViewRay MRIdian RTP System, the figure was analyzed by PTV(=seroma volume + margin) to obtain a specific volume of the Partial breast radiation therapy. Results : The changes of seroma volume from MR simulation to the first treatment (a week) is 0~5% in 8, 5~10% in 3, 10 to 15% in 2, and 20% or more in 5 people. Two patients(A, B patient) among subjects showed the biggest change. The A patient's 100% of the prescribed dose volume is 213.08 cc, PTV is 181.93 cc, seroma volume is 15.3 cc in initial plan. However, while seroma volume decreased 65.36% to 5.3 cc, 100% of the prescribed dose volume was reduced to 3.4% to 102.43 cc and PTV also did 43.6% to 102.54 cc. In the case of the B patient, seroma volume decreased 42.57% from 20.2 cc to 11.6 cc. Because of that, 100% of the prescribed dose volume decreased 8.1% and PTV also did to 40%. Conclusion : As the period between the first therapy and surgery is shorter, the patient is elder and the size of sample is smaller than 100 cc, the change grow bigger. It is desirable to establish an adaptive plan according to each patient's changes of seroma volume through continuous observation. Because partial breast patients is more sensitive than WBRT patients about dose conformity in accordance with the volume change.

  • PDF

Region of Interest Analysis for Standardized Uptake Value Ratio of 18F-fludeoxyglucose PET: Mild Cognitive Impairment and Alzheimer's Disease (경도인지장애와 알츠하이머병 환자의 18F-fludeoxyglucose PET 표준 섭취계수율에 대한 체적 및 피질 표면 기반 관심영역 분석)

  • Kim, Seonjik;Yoon, Uicheul
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.6
    • /
    • pp.237-242
    • /
    • 2018
  • $^{18}F$-fludeoxyglucose PET (FDG-PET) can help finding an abnormal metabolic activity in brain. In this study, we evaluated an efficiency of volume- and cortical surface-based analysis which were used to determine whether standardized uptake value ratio (SUVR) of FDG-PET was different among Alzheimer's disease (AD), mild cognitive impairment (MCI), and healthy control (HC). Each PET image was rigidly co-registered to the corresponding magnetic resonance imaging (MRI) using mutual information. All voxels of the co-registered PET images were divided by the mean FDG uptake of the cerebellum cortex which was thresholded by partial volume effect (>0.9). Also, the SUVR value of each vertex was linearly interpolated from volumetric SUVR image which was thresholded by gray matter partial volume effect (>0.1). Lobar mean values were calculated from both volume- and cortical surface-based SUVRs. Statistical analysis was conducted to compare two measures for AD, MCI and HC groups. Even though the results of volume (SUVR_vol) and cortical surface-based SUVR (SUVR_surf) analysis were not significantly different from each other, the latter would be better for detecting group differences in SUVR of PET.

A Comparative Analysis of Standard Uptake Value Using the Recovery Coefficient Before and After Correcting Partial Volume Effect (부분 체적 효과에서 회복 계수를 이용한 보정 전과 후 SUV의 비교 분석)

  • Ko, Hyun-Soo;Park, Soon-Ki;Choi, Jae-Min;Kim, Jung-Sun;Jung, Woo-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.10-16
    • /
    • 2011
  • Purpose: The partial volume effect occurs because of limit of the spatial resolution. It makes partial loss of intensity and causes SUV to be lower than it should actually be. So the purpose of this study is to calculate recovery coefficient for correcting PVE from phantom study and to compare before and after SUV correction applying to PET/CT examination. Materials and Methods: The flangeless Esser PET phantom consisting of four hot cylinders was used for this study. All of the hot cylinders were filled with FDG solution of 20.72 MBq per 1000 ml, and the phantom background was filled with FDG solution of different concentrations (33.30, 22.20, 16.65 MBq per 6440 ml) to yield H/B ratios of around 4:1, 6:1 and 8:1. Using the Biograph Truepoint 40(SIEMENS, Germany), we applied recovery coefficient method to 30 patients who were diagnosed with lung cancer after PET/CT exam. And then we analyzed and compared SUV before and after correcting partial volume effect. Results: The smaller the diameter of hot cylinder becomes, the more recovery coefficient decreased. When we applied recovery coefficient to clinical patients and compared SUV before and after correcting PVE, before the correction all lesions gave an average max SUV of 7.83. And after the correction, the average max SUV increases to 10.31. The differences in the max SUV between before and after correction were analyzed by paired t test. As a result, there were statistically significant differences (t=7.21, p=0.000). Conclusion: The SUV for quantification should be measured precisely to give consistent information of tumor uptake. But PVE is one of factors that causes SUV to be lower and to be underestimated. We can correct this PVE and calculate corrected SUV using the recovery coefficient from phantom study. And if we apply this correction method to clinical patients, we can finally assess and provide quantitative analysis more accurately.

  • PDF

Partial Molal Volume and Viscosity of Tetraethylammonium Chloride in Dimethyl Sulfoxide-Water Mixtures (Dimethyl Sulfoxide-물 混合溶媒中에서 Tetraethylammonium Chloride의 分몰容積 및 粘度에 관한 硏究)

  • Cho Byung Rin;Lee Yong Ja;Lee Ikchoon
    • Journal of the Korean Chemical Society
    • /
    • v.19 no.1
    • /
    • pp.3-10
    • /
    • 1975
  • The partial molal volumes and relative viscosities of tetraethylammonium chloride in a series of dimethyl sulfoxide (DMSO)-water mixtures were measured at $30^{\circ}C$. A maximum structuredness of solvent, that leads to a minimum viscosity A-coefficient and a maximum viscosity B-coefficient of the Jones-Dole equation(${\eta}_r=1+AC^{1/2}$ + BC), was found at 0.2${\sim}$0.3 mole fraction of DMSO. The solvent structure, that leads to a minimum partial molal volume due to the maximum electrostrictive effect of chloride ion and to a minimum viscosity B-coefficient, was found at 0.4${\sim}$0.5 mole fraction of DMSO. An approximate relationship between the limiting effective flowing volume, $V_e^{\circ}$, and the B-coefficient was found to be B = 2.5 $V_e^{\circ}$ in the Einstein equation.

  • PDF

The Pressure Effect on the Ionic Association of the 3,5,N-trimethyl Pyridinium Iodide in Ethanol-Water Mixture

  • Jong-Gi Jee;Young Hwa Lee;Kyung-Hee Lee;Oh Cheun Kwun
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.3
    • /
    • pp.112-117
    • /
    • 1984
  • The association constants (K) of 3,5,N-trimethyl pyridinium iodide in 95 volume percent ethanol-water mixed solvent were determined by a modified UV and conductance method at $25^{\circ},\;30{\circ},\;40{\circ}\;and\;50{\circ}C$ over the pressure range 1 to 2000 bars. The association process is enhanced with increasing pressure and decreasing temperature. From K values, we obtained the total partial molar volume change (${\Delta}V$) and some thermodynamic parameters. The electrostriction volume (${\Delta}V_{el}$) and intrinsic volume (${\Delta}V_{in}$) were also evaluated. The values of ${\Delta}V,\;{\Delta}V_{el},\;{\Delta}V_{in}$ are negative, negative and positive, respectively, and the absolute values of all these three decrease with increasing pressure and temperature. The ion-pair size (a) were varied 3 to 6 ${\AA}$, with pressure and temperature. The solvation number (n) decreased from 2 to 0.5 with increasing temperature.

The Optimization of Reconstruction Method Reducing Partial Volume Effect in PET/CT 3D Image Acquisition (PET/CT 3차원 영상 획득에서 부분용적효과 감소를 위한 재구성법의 최적화)

  • Hong, Gun-Chul;Park, Sun-Myung;Kwak, In-Suk;Lee, Hyuk;Choi, Choon-Ki;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.13-17
    • /
    • 2010
  • Purpose: Partial volume effect (PVE) is the phenomenon to lower the accuracy of image due to low estimate, which is to occur from PET/CT 3D image acquisition. The more resolution is declined and the lesion is small, the more it causes a big error. So that it can influence the test result. Studied the optimum image reconstruction method by using variation of parameter, which can influence the PVE. Materials and Methods: It acquires the image in each size spheres which is injected $^{18}F$-FDG to hot site and background in the ratio 4:1 for 10 minutes by using NEMA 2001 IEC phantom in GE Discovey STE 16. The iterative reconstruction is used and gives variety to iteration 2-50 times, subset number 1-56. The analysis's fixed region of interest in detail part of image and compute % difference and signal to noise ratio (SNR) using $SUV_{max}$. Results: It's measured that $SUV_{max}$ of 10 mm spheres, which is changed subset number to 2, 5, 8, 20, 56 in fixed iteration to times, SNR is indicated 0.19, 0.30, 0.40, 0.48, 0.45. As well as each sphere's of total SNR is measured 2.73, 3.38, 3.64, 3.63, 3.38. Conclusion: In iteration 6th to 20th, it indicates similar value in % difference and SNR ($3.47{\pm}0.09$). Over 20th, it increases the phenomenon, which is placed low value on $SUV_{max}$ through the influence of noise. In addition, the identical iteration, it indicates that SNR is high value in 8th to 20th in variation of subset number. Therefore, to reduce partial volume effect of small lesion, it can be declined the partial volume effect in iteration 6 times, subset number 8~20 times, considering reconstruction time.

  • PDF