• 제목/요약/키워드: Partial volume effect

검색결과 115건 처리시간 0.032초

n-Alkyl amine 鹽酸鹽의 水溶液 中에서의 apparent 및 partial molal volumes에 관한 硏究 (A study on the apparent and partial molal volumes of n-Alkyl amine hydrochloride in water)

  • 운상기
    • 대한화학회지
    • /
    • 제13권2호
    • /
    • pp.121-129
    • /
    • 1969
  • n-Alkylamine hydrochlorides $C_nH_{2n+1}NH_3CI$에서 n=0에서 n=4 까지 이르는 低分子量 同族體의 apparent molal volume {\phi}\nu$ 및 partial molal volume $V^{\circ}$을 30$^{\circ}C$水溶液에서 測定하엿다 아민산의 濃度는 0.01M에서 0.3M까지 , 密度測定은 浮力法(Float method)를 適用하여 少數點 以下 5位까지 取하였다. 實驗結果 同族體의 分子量이 一定量 $CH_2$식 增加함에 따라 $V^{\circ}$값이 規則的인 差로서 增加한다는 事實이 觀測되었다. 또한 濃度增加함에 따른 {\phi}\nu$ 變化는 共通的으로 直選的이고 limiting slope는 positive이며 比較的 理論値에 가까왔다. 共通anion인 鹽素이온 $CI^-$의 partial molal volume, $V^{\circ}$$CI^-$은 18.6ml $mole^{-1}$으로 他硏究者들의 date와 大體的으로 一致하였다. {\phi}{\nu}$ 값의 變化로 보아 이온의 hydrophobic effect와 change effect는 거의 競合狀態이나 charge effect 곧 electrostriction effect가 優勢를 보였다.

  • PDF

환자 대장 CT 프로파일을 이용한 전자적 장세척 방법 (An Electronic Colon Cleansing Method using a Patient Colon CT Profile)

  • 김한별;김동성
    • 한국정보과학회논문지:소프트웨어및응용
    • /
    • 제35권8호
    • /
    • pp.493-500
    • /
    • 2008
  • 가상 대장 내시경을 위해서 환자 대장 CT 프로파일을 이용한 전자적 장세척 방법을 제안한다. 제안된 방법은 관강 영역을 cubic seeded region growing(SRG) 방법을 이용하여 추출하고, 이에 인접한 tagged material(TM)을 제거한다. TM의 경계에서 Air-TM의 partial volume(PV) 효과로 발생한 찌꺼기를 제거하고, TM-soft tissue(ST)의 PVE에 의해서 제거된 ST는 환자 CT 프로파일을 이용해서 복원한다. 제안된 방법을 16명의 가상 내시경 환자 CT 데이타에 적용해서 임상의의 주관적인 평가와 computer-aided diagnosis(CAD)의 정량적 평가에서 매우 고무적인 결과를 획득했다.

MR-based Partial Volume Correction for $^{18}$F-PET Data Using Hoffman Brain Phantom

  • Kim, D. H.;Kim, H. J.;H. K. Jeong;H. K. Son;W. S. Kang;H. Jung;S. I. Hong;M. Yun;Lee, J. D.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.322-323
    • /
    • 2002
  • Partial volume averaging effect of PET data influences on the accuracy of quantitative measurements of regional brain metabolism because spatial resolution of PET is limited. The purpose of this study was to evaluate the accuracy of partial volume correction carried out on $^{18}$ F-PET images using Hoffman brain phantom. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices of the same phantom. All the MR slices of the phantom were then segmented to be binary images. Each of these binary images was convolved in 2 dimensions with the spatial resolution of the PET. The original PET images were then divided by the smoothed binary images in slice-by-slice, voxel-by-voxel basis resulting in larger PET image volume in size. This enlarged partial volume corrected PET image volume was multiplied by original binary image volume to exclude extracortical region. The evaluation of partial volume corrected PET image volume was performed by region of interests (ROI) analysis applying ROIs, which were drawn on cortical regions of the original MR image slices, to corrected and original PET image volume. From the ROI analysis, range of regional mean values increases of partial volume corrected PET images was 4 to 14%, and average increase for all the ROIs was about 10% in this phantom study. Hoffman brain phantom study was useful for the objective evaluation of the partial volume correction method. This MR-based correction method would be applicable to patients in the. quantitative analysis of FDG-PET studies.

  • PDF

산·염기 적정에서 용액의 부피 변화에 대한 대학생들의 오개념 연구 (College Students' Misconception about the Volume Change of Solution during Acid/Base Titration: Partial Molar Volume of Salt)

  • 장낙한
    • 과학교육연구지
    • /
    • 제33권2호
    • /
    • pp.317-320
    • /
    • 2009
  • 부피 측정법을 이용하여 산 염기 적정 실험에서 중화점을 측정할 때, 나는 용액의 부피 변화에 대한 한국 대학생들의 개념을 조사하였다. 이 연구에 의하면, 대부분의 대학생들은 산 염기 적정 동안 중화반응에 의해 물이 생성되기 때문에 부피가 증가한다는 오개념을 갖고 있었다. 그러나 이것은 용액에 있는 염에 의한 효과를 무시한 것이기 때문에, 부피 변화를 설명하는데 충분하지 않다. HCl/NaOH 중화반응 동안 용액의 부피 증가를 설명하기 위해, 나는 생성된 NaCl의 부분 몰부피를 계산하였다. 실험 결과와 계산된 부분 몰부피를 비교할 때, 나는 부피 증가의 주요 효과는 HCl/NaOH 중화반응 동안 생성된 NaCl의 부분 몰부피 때문이라는 것을 밝혔다. 여기서 산 염기 중화 적정 동안 용액의 부피 변화에 대한 오개념을 줄이기 위해, 나는 부분 몰부피의 개념을 대학생들에게 도입하도록 제안한다.

  • PDF

Electrical Insulation Characteristics at Cryogenic Temperature for High Temperature Superconducting Cables

  • Okubo, Hitoshi;Hayakawa, Naoki
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.15-20
    • /
    • 2004
  • This paper discusses electrical insulation characteristics at cryogenic temperature, especially focusing on partial discharge (PD) inception characteristics, for high temperature superconducting cables. In liquid nitrogen (L$N_2$) / polypropylene (PP) laminated paper composite insulation system, PD inception strength (PDIE) was evaluated in terms of volume effect and V-t characteristics. Different kinds of butt gap condition were applied in the experiments, using parallel plane and coaxial cylindrical cable samples. Experimental results revealed that the volume effect on PDIE could be evaluated by the statistical stressed liquid volume (SSLV) taking account the discharge probability not only in the butt gap but also in the other thin layers between PP laminated papers. Furthermore, the indices n of V-t characteristics at PD inception were estimated to be 80∼110, irrespective of the butt gap condition.

정상 및 미주신경절단 흰쥐의 체중, 위액 분비량, 위의 형태변화에 대한 위 유문부 부분폐색과 재개통의 효과 (Effect of partial pyloric obstruction on body weight, gastric juice, gastric surface area and gastric edema in normal intact rats and/or vagotomized rats)

  • 선종기;윤상협
    • 대한한방내과학회지
    • /
    • 제33권1호
    • /
    • pp.26-38
    • /
    • 2012
  • Objectives : The aim of this study was to investigate the effect of partial pyloric obstruction on body weight, gastric juice, gastric surface area and gastric edema in normal intact and/or vagotomized rats. Methods : Partial pyloric obstruction was performed by wrapping a non-absorbable rubber ring (D:6 mm, W:4 mm, T:1 mm) around the 1st portion of the duodenum. Vagotomy was performed by resecting the branches around the esophagogastric junction. Pre-post body weight differential, fasting gastric juice volume, gastric surface area and gastric edema were measured at 8 weeks and 20 weeks. For the effect of pyloric reperfusion the rubber ring was removed after 8 weeks and then an additional 12 weeks of observation was performed to the end of the 20-week experimental period. Results : In the initial 8 weeks observation, the effect of pylorus obstruction and/or vagotomy was significantly remarkable in the pylorus obstructed and vagotomized group; slowdown of weight gain, increase of fasting gastric juice volume, dilatation of gastric surface area and severe gastric edema were shown. In the remaining 12 weeks observation, the effect of reperfusion was significantly remarkable in the ring-removed antral dilated group; recovery of weight gain, decrease of gastric surface area and decrease of gastric edema were shown. However, gastric juice volume was not significantly different from the other group. Conclusions : Partial pyloric obstruction plays a aggravating role and the vagus nerve plays a protective role in body weight, gastric juice, gastric surface area, and gastric edema. Furthermore, pyloric valve dysfunction as an aggravating factor strengthened in defect of the vagus nerve. These results suggest that patients with both functional pyloric outlet obstruction and hypofunction of vagus nerve need to be diagnosed in good time and treated properly.

부분용적효과 제거를 위한 Filter 구현 (Implementation of Filter for the Removal of Partial Volume Effect)

  • 박민주;이상복
    • 한국방사선학회논문지
    • /
    • 제9권3호
    • /
    • pp.139-145
    • /
    • 2015
  • SPECT를 이용한 환자의 검사 시 몸 안에서 방출되는 ${\gamma}$-선은 감쇠 또는 산란 등의 현상이 일어나며, 검출기에 도달할 때 조준기의 물리적 특성과 기학적인 모양에 따라 퍼지는 현상이 발생하여 정량분석이 불가능하였다. 체내에서 방출되는 ${\gamma}$-선의 정확한 정량분석을 위해서는 반드시 부분용적효과에 대한 보정이 고려되어야 한다. 본 논문에서는 SPECT의 종합적인 부분용적효과를 해결하기 위하여 Sinogram Filter를 구현하였다. 구현된 Filter를 적용하여 실험을 한 결과, SPECT에서 발생되는 부분용적효과를 제거하였다. 기존방법과 제안한 방법을 비교하기 위하여 PSNR을 시행한 결과 제안한 방법으로 한 경우 PSNR은 7 dB, 기존방법은 14 dB로 나왔다. 제안한 방법의 dB이 낮아진 이유는 산란선 제거를 많이 하여 MSE가 높아지기 때문에 PSNR값이 낮게 나타났다. 따라서 제안한 방법을 적용한다면 SPECT 영상의 부분용적효과를 제거하여 영상의 질이 좋아질 것이다.

메탄올-물 혼합액에서의 n-Alkylamine 염산염의 분 몰랄 부피 (Partial molal volumes of n-alkylamine hydrochlorides in methanol-water mixtures)

  • 엄태섭;윤상기;이익춘
    • 대한화학회지
    • /
    • 제14권1호
    • /
    • pp.51-59
    • /
    • 1970
  • Methyl에서 n-butyl까지의 n-alkylamine 염산염동족체($RNH_3Cl$)의 "겉보기몰랄부피"(apparent molal volume)${\phi}_v$를 30$^{\circ}C$에서 여러가지 조성의 methanol-물 혼합액을 써서 측정하였다. 아민염의 농도는 0.01M까지, 밀도는 부력법을 적용하여 소수점이하 5위까지 택하였다. 관측된 ${\phi}_v$값을 무한대의 농도 쪽으로 extapolation하여 "분몰랄부피"(partial molal volume)$\bar{V}^{\circ}$V를 구하였다. 실험결과는 용질입자의 크기, charge 및 hydrophobic effect등에 관하여 논의되었고 또한 동족체간에일정한 몰랄부피차(${\Delta}\bar{V}^{\circ}$)를 갖는다는 사실과 아울러 혼합용매의 구조에 대하여도 검토하였다. 메탄올-물 0.1몰분율(m.f.)에서는 물의 구조증대로 cation의 "분몰랄부피($\bar{V}^{\circ}_+$)가 최소이고, 한편 0.4m.f. 에서는 charge 효과에 의한 electrostriction effect의 최대화 free volume이 최소라는 사실들이 관찰되었다.

  • PDF

부분용적효과를 고려한 확산텐서영상에 대한 관심영역 분석 연구 (ROI Study for Diffusion Tensor Image with Partial Volume Effect)

  • 최우혁;윤의철
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권2호
    • /
    • pp.84-89
    • /
    • 2016
  • In this study, we proposed ameliorated method for region of interest (ROI) study to improve its accuracy using partial volume effect (PVE). PVE which arose in volumetric images when more than one tissue type occur in a voxel, could be used to reduce an amount of gray matter and cerebrospinal fluid within ROI of diffusion tensor image (DTI). In order to define ROIs, individual b0 image was spatially aligned to the JHU DTI-based atlas using linear and non-linear registration (http://cmrm.med.jhmi.edu/). Fractional anisotropy (FA) and mean diffusivity (MD) maps were estimated by fitting diffusion tensor model to each image voxel, and their mean values were computed within each ROI with PVE threshold. Participants of this study consisted of 20 healthy controls, 27 Alzheimer's disease and 27 normal-pressure hydrocephalus patients. The result showed that the mean FA and MD of each ROI were increased and decreased respectively, but standard deviation was significantly decreased when PVE was applied. In conclusion, the proposed method suggested that PVE was indispensable to improve an accuracy of DTI ROI study.

PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교 (Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images)

  • 김영재;박훈희;이주영;소영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.