• 제목/요약/키워드: Partial volume correction

검색결과 15건 처리시간 0.027초

MR-based Partial Volume Correction for $^{18}$F-PET Data Using Hoffman Brain Phantom

  • Kim, D. H.;Kim, H. J.;H. K. Jeong;H. K. Son;W. S. Kang;H. Jung;S. I. Hong;M. Yun;Lee, J. D.
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.322-323
    • /
    • 2002
  • Partial volume averaging effect of PET data influences on the accuracy of quantitative measurements of regional brain metabolism because spatial resolution of PET is limited. The purpose of this study was to evaluate the accuracy of partial volume correction carried out on $^{18}$ F-PET images using Hoffman brain phantom. $^{18}$ F-PET Hoffman phantom images were co-registered to MR slices of the same phantom. All the MR slices of the phantom were then segmented to be binary images. Each of these binary images was convolved in 2 dimensions with the spatial resolution of the PET. The original PET images were then divided by the smoothed binary images in slice-by-slice, voxel-by-voxel basis resulting in larger PET image volume in size. This enlarged partial volume corrected PET image volume was multiplied by original binary image volume to exclude extracortical region. The evaluation of partial volume corrected PET image volume was performed by region of interests (ROI) analysis applying ROIs, which were drawn on cortical regions of the original MR image slices, to corrected and original PET image volume. From the ROI analysis, range of regional mean values increases of partial volume corrected PET images was 4 to 14%, and average increase for all the ROIs was about 10% in this phantom study. Hoffman brain phantom study was useful for the objective evaluation of the partial volume correction method. This MR-based correction method would be applicable to patients in the. quantitative analysis of FDG-PET studies.

  • PDF

PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교 (Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images)

  • 김영재;박훈희;이주영;소영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.

자기공명영상을 이용한 양전자방출단층촬영의 부분용적효과 보정 및 임상적용 (MR-based Partial Volume Correction Using Hoffman Brain Phantom Data and Clinical Application)

  • 김동현;이상호;정해조;윤미진;이종두;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제14권3호
    • /
    • pp.203-210
    • /
    • 2003
  • 양전자방출단층촬영장치는 인체나 실험 동물 생체 내에서 일어나는 생화학적, 생리학적 과정을 정량 분석할 수 있는 장점으로 인해 핵의학에서 중요한 역할을 하고 있다. 그러나 지속적인 핵의학기기의 발전에도 불구하고 PET은 여전히 분해능이 낮다는 단점이 있으며, 이로인해 부분용적효과가 발생한다. 본 연구에서는 호프만 팬텀 PET영상을 대상으로 MR 영상을 이용해 부분용적효과를 보정한 뒤 복원된 픽셀값이 백질과 회백질간의 글루코즈 흡수비율인 1:3에 근접하는 정도를 알아보고 실제 정상인 환자의 PET 영상을 같은 방법으로 보정하여 임상적용의 가능성을 알아보았다. 먼저 호프만 팬텀의 MR 영상과 PET영상을 registration한 뒤, MR영상을 이용해 백질과 회백질 부위를 추출하여 binary image를 만들었다. 각각의 binary image를 4, 8, 12, 16 mm의 다양한 FWHM 해상도 값으로 convolution과정을 거친 뒤 회백질 부위와 백질 부위를 다시 결합하여 MR 영상과 registration된 PET영상에서 나누고, 이를 다시 뇌 전체 영역을 나타내는 binary image와 곱하여 해부학적으로 정확한 뇌 영역을 갖도록 하였다. 분석방법으로는 MR 영상에서 회백질과 백질 부위에 관심영역을 얻은 뒤, 이를 보정 이전의 영상과 4, 8, 12, 16 mm의 FWHM으로 각각 보정된 영상들에 적용하여 관심 영역내 평균 픽셀 값을 얻고 이를 이용하여 회백질과 백질 간의 평균 픽셀 값 비율을 구하였다. 또한 같은 방법으로 정상인의 PET영상을 보정하였다. 호프만 팬텀의 실험결과, 회백질과 백질 간의 보정 후 비율이 보정 이전의 비율에 비해 증가하였으며, 각각의 FWHM 조건에서도 비율 차이를 나타내었다. 정상인의 경우 역시 보정 이전에 비해 보정 이후 백질과 회백질간의 비율이 증가하는 경향을 나타내었으나, 각각의 FWHM 경우 나타난 회백질과 백질 간의 비율의 증가는 호프만 팬텀실험에 비해 약간 더 낮게 나타났다. 실험을 통해 보정 이후 호프만 팬텀의 경우 실제 백질과 회백질간의 비율인 1:3의 비율에 근접하였으며, 임상적용의 경우 보정 이 후 그 비율이 호프만 팬텀의 실험결과에 미치지는 못하지만 적절한 보정효과를 나타냈다. 또한 각각의 FWHM 값으로 보정된 결과에서 나타난 비율의 증가폭 결과를 통해 4 mm에서 16 m의 FWHM 적용에 따른 부분용적효과의 보정 정도를 알 수 있었으며, 실제 임상적용의 가능성을 제시하였다.

  • PDF

부분 체적 효과에서 회복 계수를 이용한 보정 전과 후 SUV의 비교 분석 (A Comparative Analysis of Standard Uptake Value Using the Recovery Coefficient Before and After Correcting Partial Volume Effect)

  • 고현수;박순기;최재민;김정선;정우영
    • 핵의학기술
    • /
    • 제15권1호
    • /
    • pp.10-16
    • /
    • 2011
  • 추적 검사에서의 PET/CT 재구성 영상은 추적자의 분포를 균일하고 정확하게 표현하여야 일관된 정량분석 값을 제공 할 수 있을 것이다. 그러나 PET/CT 장비의 제한된 공간분해능 때문에 발생하는 부분 체적 효과(Partial Volume Effect: PVE)로 인해 관심영역의 방사능 농도가 실제의 값보다 낮게 측정될 가능성이 있고, 따라서 관심부위의 SUV가 실제 값보다 낮게 측정 될 가능성이 있다. 본 연구에서는 PET/CT 스캐너의 PVE를 보정하는 회복계수(Recovery Coefficient: RC)를 팬텀 실험을 통해 산출하고, 실제 PET/CT 검사 자료에 적용하여 보정 전과 후 SUV를 비교 분석 하고자 한다. ACR phantom을 이용하여 1000 mL의 증류수에 20.72 MBq (0.56 mCi)을 균일하게 희석하고 열소 원통 (hot cylinder-2.5, 1.6, 1.2, 0.8 cm in diameter)에 주입하였다. 또한 6440 ml의 증류수에 33.30 MBq (0.90 mCi), 22.20 MBq (0.60 mCi), 16.65 MBq (0.45mCi)을 균일하게 희석하고 배후 방사능을 채워 열소 원통과 배후방사능이 각각 4:1, 6:1, 8:1 (Hot/Background ratio: H/B ratio)이 되도록 만들어 3회 반복 실험하였다. 서울아산병원의 Biograph Truepoint 40 (SIEMENS, Germany) 장비로 whole body protocol을 사용하여 phantom 실험 및 환자 검사를 시행하였다. 2010년 7월부터 8월까지 서울아산병원에서 PET/CT 검사 후 폐암으로 판정 받은 환자 30명을 대상으로, 본 연구의 결과에서 산출된 RC를 적용하여 PVE 보정 전과 후 SUV를 비교 분석하였다. 열소 원통과 배후방사능이 4:1일 때 2.5, 1.6, 1.2, 0.8 cm 에서의 RC는 각각 0.75, 0.72, 0.40, 0.27이었고, 6:1일 때 0.74, 0.59, 0.55, 0.43이었으며, 8:1일 때 0.77, 0.76, 0.58, 0.42로 열소 영역의 크기가 작아질수록 RC가 감소하였다. 폐암으로 판정 받은 환자 중에서 30명의 환자를 무작위 표본 추출하여 보정 전과 후의 SUV 최대값을 비교 분석 한 결과, 보정 전 평균은 7.83이었고 보정 후 평균은 10.31이었다. 또한 보정 전과 후의 SUV 최대값을 대응 표본 t 검정으로 차이를 분석한 결과, 통계적으로 유의한 차이가 있었다(t=7.21, p=0.000). PVE에 의해서 과소 평가 되었던 보정 전의 SUV가 보정 후에는 증가되는 것을 확인할 수 있었다. 병변의 크기와 H/B ratio가 환자마다 제각기 다른 값을 갖기 때문에, RC를 사용하여 PVE를 보정한 SUV가 정확한 값이라고 판단하기는 어려우나 PVE에 의해 감소된 SUV를 실제 값과 유사하게 보정할 수 있는 방법일 것으로 생각된다.

  • PDF

전자적 장세척을 위한 부드러운 장표면 복원 방법 개발 (Development of a Smooth Colon Surface Restoration Method for Electronic Colon Cleansing)

  • 김승환;김동성
    • 대한의용생체공학회:의공학회지
    • /
    • 제32권3호
    • /
    • pp.251-256
    • /
    • 2011
  • Virtual colonoscopy is favored over conventional colonoscopy because its non-invasive procedure can avoid complications that may happen in a conventional approach and because it can cleanse colon electronically instead of uncomfortable conventional colon cleansing. Electronic Colon Cleansing(ECC) has to deal with not only removing tagged fecal material but also recovering Partial Volume Effect(PVE) due to tagging material. This paper proposes an ECC method restoring inherent natural PVE while previous approaches focused only on reducing PVE due to tagged fecal material. The proposed method reduces PVE using 3-dimensional adaptive density correction and then replaces tagged fecal material into air. Next, it generates natural PVE for the replaced air adjacent to soft tissue and finally makes smooth transition of gray values for soft tissue adjacent to the replaced air. The proposed method applied to eleven patient data, and showed promising results.

부분용적효과 제거를 위한 Filter 구현 (Implementation of Filter for the Removal of Partial Volume Effect)

  • 박민주;이상복
    • 한국방사선학회논문지
    • /
    • 제9권3호
    • /
    • pp.139-145
    • /
    • 2015
  • SPECT를 이용한 환자의 검사 시 몸 안에서 방출되는 ${\gamma}$-선은 감쇠 또는 산란 등의 현상이 일어나며, 검출기에 도달할 때 조준기의 물리적 특성과 기학적인 모양에 따라 퍼지는 현상이 발생하여 정량분석이 불가능하였다. 체내에서 방출되는 ${\gamma}$-선의 정확한 정량분석을 위해서는 반드시 부분용적효과에 대한 보정이 고려되어야 한다. 본 논문에서는 SPECT의 종합적인 부분용적효과를 해결하기 위하여 Sinogram Filter를 구현하였다. 구현된 Filter를 적용하여 실험을 한 결과, SPECT에서 발생되는 부분용적효과를 제거하였다. 기존방법과 제안한 방법을 비교하기 위하여 PSNR을 시행한 결과 제안한 방법으로 한 경우 PSNR은 7 dB, 기존방법은 14 dB로 나왔다. 제안한 방법의 dB이 낮아진 이유는 산란선 제거를 많이 하여 MSE가 높아지기 때문에 PSNR값이 낮게 나타났다. 따라서 제안한 방법을 적용한다면 SPECT 영상의 부분용적효과를 제거하여 영상의 질이 좋아질 것이다.

Partial anomalous pulmonary venous connection with intact atrial septum in a child with ventricular septal defect: a case report

  • Kim, Young-Nam;Cho, Hwa-Jin;Cho, Young-Kuk;Ma, Jae-Sook
    • Clinical and Experimental Pediatrics
    • /
    • 제55권1호
    • /
    • pp.24-28
    • /
    • 2012
  • Partial anomalous pulmonary vein connection (PAPVC) is a rare congenital abnormal cardiac defect involving the pulmonary veins draining into the right atrium (RA) directly or indirectly by venous connection. Ninety percent of PAPVCs are accompanied by atrial septal defect (ASD). To our knowledge, there is no previous report of PAPVC with ventricular septal defect (VSD) without ASD in Korea, and in this paper, we report the first such case. A 2-day-old girl was admitted into the Chonnam National University Hospital for evaluation of a cardiac murmur. An echocardiogram revealed perimembranous VSD without ASD. She underwent patch closure of the VSD at 5 months of age. Although the VSD was completely closed, she had persistent cardiomegaly with right ventricular volume overload, as revealed by echocardiography. Three years later, cardiac catheterization and chest computed tomography revealed a PAPVC, with the right upper pulmonary vein draining into the right SVC. Therefore, correction of the PAPVC was surgically performed at 3 years of age. We conclude that it is important to suspect PAPVC in patients with right ventricular volume overload, but without ASD.

원형단일결정을 이용한 SPECT의 정량화 연구 (Quantitative Study of Annular Single-Crystal Brain SPECT)

  • 김희중;김한명;소수길;봉정균;이종두
    • 한국의학물리학회지:의학물리
    • /
    • 제9권3호
    • /
    • pp.163-173
    • /
    • 1998
  • 핵의학 단층촬영기를 이용하여 몸 안에서 일어나는 신진대사, 혈류량 공급, 생화학적 변화, 또는 뇌에서의 도파민 운반체, 수용체 등의 영상을 획득한 후 정량화할 수 있다면 환자의 조기진단뿐만 아니라 치료계획을 세우고 치료경과 등을 객관적으로 측정하는데 매우 유용할 것이다. 그러나 물리적 요소들인 감쇠, 산란, 부분용적 효과, 노이즈, 그리고 재구성 알고리즘 등은 SPECT 의 디자인에 관계없이 영상의 정성적 또는 정량적 결과에 영향을 미친다. 본 논문에서는 뇌 촬영용 단일 결정 SPECT와 뇌 모형 팬텀을 이용하여 물리적 요소들 중 특히 감쇠와 산란의 영향을 정량화하고 보정 방법에 따른 결과를 정량 분석하였다. 산란 보정은 주 에너지 창 140keV$\pm$10% (126~154 keV)와 산란에너지 창 119keV$\pm$6% (112~126keV)를 이용하여 데이터를 획득한 후 산란 에너지 창의 100%를 빼주는 방법을 적용하였다. 영상 재구성은 차단주파수 0.95cycles/cm와 차수 10을 적용한 저역통과 Butterworth 여과기로 여과하여 여과후 역투사 방법으로 재구성하였다. 감쇠 상수는 산란 보정을 하지 않은 경우와 한 경우에 따라 각각 0.12cycles/cm 와 0.15cycles/cm 를 적용하여 뇌 내에서의 균일한 감쇠계수로 가정하고 Chang 방법에 의하여 감쇠에 대한 보정을 하였다. 정량분석을 위해 기저핵이 뚜렷이 보이는 3개의 단층면을 선택하여 기저핵과 그 외 뇌 영역에 관심영역을 구하였다. 산란보정을 하지 않았을 때 감쇠보정을 한 후의 ROI 값은 감쇠 보정전 ROI 값에 비해 기저핵 2.20배 배후 방사능 2.10배였다. 반면에 감쇠보정 후와 감쇠보정 전의 기저핵과 배후방사능의 비율은 매우 비슷했다. 산란보정을 한 후 감쇠보정을 한 ROI 값은 감쇠보정 전 ROI 값과 비교할 때 기저핵 2.69 배 배후 방사능 2.64 배로 뇌 영상의 절대적 정량적 분석을 위해서는 반드시 감쇠 보정이 필요한 것을 보여준다. 기저핵과 배후 방사능의 참값 비율이 6.58, 4.68, 1.86 일 때 산란 보정과 감쇠보정을 한 경우는 참값의 76%, 80%, 82%로 측정하였고 감쇠보정을 하지 않은 경우는 75%, 81%, 81%로 측정하였다. 참값의 비율이 낮을수록 참값에 가깝게 측정하였으나 산란과 감쇠보정을 한 경우에도 참값에 비해 약 20% 의 과소평가를 볼 수 있었다. 이는 본 논문에서 자세히 다루지 않은 부분용적 효과와 재구성 알고리즘 그리고 위에서 적용한 대략적인 감쇠와 산란보정 방법의 원인으로 사료되며 앞으로 더욱 연구되어야 할 분야이다.

  • PDF

Usefulness of Oncoplastic Volume Replacement Techniques after Breast Conserving Surgery in Small to Moderate-sized Breasts

  • Yang, Jung Dug;Kim, Min Chul;Lee, Jeong Woo;Cho, Young Kyoo;Choi, Kang Young;Chung, Ho Yun;Cho, Byung Chae;Park, Ho Yong
    • Archives of Plastic Surgery
    • /
    • 제39권5호
    • /
    • pp.489-496
    • /
    • 2012
  • Background In Korean women, many of whom have small to moderate-sized breasts, it is difficult to cover a partial breast defect using oncoplastic volume displacement techniques after removal of an adequate volume of tissue during oncologic surgery. In such cases, oncoplastic volume replacement techniques are more useful. Methods From January 2007 to December 2011, 104 women underwent a total of 107 breast-conserving surgeries with various kinds of oncoplastic volume replacement techniques. We used latissimus dorsi (LD) myocutaneous flap for cases in which the resection mass was greater than 150 g. In case with a resection mass less than 150 g, we used regional flaps such as a lateral thoracodorsal flap, a thoracoepigastric flap, or perforator flaps such as an intercostal artery perforator (ICAP) flap or a thoracodorsal artery perforator (TDAP) flap. Results The mean age was 46.1 years, and the average follow-up interval was 10.3 months. The patients underwent oncoplastic volume replacement techniques with a lateral thoracodorsal flap (n=9), thoracoepigastric flap (n=7), ICAP flap (n=25), TDAP flap (n=12), and LD flap (n=54). There was one case of congestion in an LD flap, and two cases of fat necrosis in an ICAP flap. Most of the patients were satisfied with the cosmetic results. Conclusions Oncoplastic volume replacement techniques can be reliable and useful for the correction of breast deformity after breast-conserving surgery, especially in patients with small to moderate-sized breasts.

뇌기능 양전자방출단층촬영영상 분석 기법의 방법론적 고찰 (Methodological Review on Functional Neuroimaging Using Positron Emission Tomography)

  • 박해정
    • Nuclear Medicine and Molecular Imaging
    • /
    • 제41권2호
    • /
    • pp.71-77
    • /
    • 2007
  • Advance of neuroimaging technique has greatly influenced recent brain research field. Among various neuroimaging modalities, positron emission tomography has played a key role in molecular neuroimaging though functional MRI has taken over its role in the cognitive neuroscience. As the analysis technique for PET data is more sophisticated, the complexity of the method is more increasing. Despite the wide usage of the neuroimaging techniques, the assumption and limitation of procedures have not often been dealt with for the clinician and researchers, which might be critical for reliability and interpretation of the results. In the current paper, steps of voxel-based statistical analysis of PET including preprocessing, intensity normalization, spatial normalization, and partial volume correction will be revisited in terms of the principles and limitations. Additionally, new image analysis techniques such as surface-based PET analysis, correlational analysis and multimodal imaging by combining PET and DTI, PET and TMS or EEG will also be discussed.