• 제목/요약/키워드: Partial resonant

검색결과 105건 처리시간 0.025초

소프트 스위칭형 PFC 승강압 AC-DC 컨버터에 관한 연구 (A Study on PFC Buck-Boost AC-DC Converter by Soft Switching Method)

  • 곽동걸;이승호;이봉섭;정도영;심재선;임진근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.435-437
    • /
    • 2007
  • Authors propose a PFC(power factor correction) Buck-Boost AC-DC converter by soft switching method. The proposed converter for a discontinuous conduction mode eliminates the complicated control requirement and reduces the size of components. The input current waveform in the converter is got to be a sinusoidal form of discontinuous pulse in proportion to magnitude of ac input voltage under the constant duty cycle switching.Therefore,the input power factor is nearly unity and the control algorithm is simple. To achieve high efficiency system, the proposed converter is constructed by using a partial resonant technique. The control switches using in the converter are operated with soft switching for a partial resonant. The control switches are operated without increasing their voltage and current stresses by the soft switching method. The result is that the switching loss is very low and the efficiency of converter is high.

  • PDF

HVAC에 의한 On-line, Off-line PD 모니터링 (On-line and Off-line Partial Discharge Monitoring System with HVAC Testing)

  • 최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.111-114
    • /
    • 2008
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

부분 모드만을 고려하여 성형된 입력을 이용한 잔류 진동의 감소 효과 (Reducing Effect of Residual Vibration Through Command Input Shaped Considering Partial Modes)

  • 정광석
    • 융복합기술연구소 논문집
    • /
    • 제1권1호
    • /
    • pp.18-23
    • /
    • 2011
  • Shaping an input command through considering the resonant modes of multi degrees of freedom system, it is possible to realize the wanted motion, without exciting the uncontrollable modes of the flexible system. But, an increase of modes to be considered brings inevitably about the time delay due to an excessive rising time. On the purpose of reducing the rising time, only the interesting and dominant modes can be considered to determine the timing pulses of input shaper. In this paper, an effect of shaper by the partial modes is analysed for a specific system and the input shapers by the partial modes are analysed for three d.o.f damped system, using Matlab simulation.

  • PDF

PWM 제어 방법을 이용한 LCL 직렬 공진 콘버터에 관한 연구 (LCL Type Series Resonant Converter with PWM Control Method)

  • 현동석;이요한;추병호;송인호;민경진
    • 전력전자학회논문지
    • /
    • 제2권2호
    • /
    • pp.19-28
    • /
    • 1997
  • 본 논문에서는 위상제어를 이용한 LCL형 직렬공진 콘버터의 간단한 AC 복소해석이 수행되었다. 이 해석에 근거하여 탱크 회로의 volt-ampere 정격을 증가시키지 않는 콘버터의 최적 설계를 가능하게 하는 일련의 특성곡선들을 제시하였다. 특히 정격부하나 경부하에서도 인버터 출력전류의 피크치를 최소화할 수 있게 되었다. 제시한 설계 예에서, 과부하에서 경부하에 이르는 넓은 부하범위에서 영전압 턴온 동작을 할 수 있음을 보여준다. 시뮬레이션과 실험결과를 통해 제안된 회로의 유용성을 증명한다.

  • PDF

자기 변형 공진 기구를 이용한 레이저 스캐닝 진동측정기에 관한 연구 (A Study on a Laser Scanning Vibrometer Using a Magnetostrictive Resonant Device)

  • 이정화;류제길;박기환
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.58-66
    • /
    • 1998
  • A low power consuming laser scanning vibrometer is studied for its development. For its optical system, a laser interferometer is constructed to use the Doppler effect. In order to reduce the driving power of the scanning system, a small displacement of the scanning system is produced, which is achieved by using a magnetostrictive actuator. A sufficient rotating angle of the scanning system is obtained by using an amplified displacement from the resonant phenomena of a second order mechanical system composed of a mass and spring. The control of the magnetostrictive actuator using a Terfenol-D is performed without using a feedback system to help reduce the power consumption. The vibration analysis is made for the sinusoidal scanning input to have the space domain information from the time domain of the velocity of a vibration object. As a partial work of development of a tow power consuming laser scanning vibrometer, in this work, a scanning system which has the above features is developed and experimentally investigated. For the purpose of the optical system calibration, the vibration measurement for one axis is presented and the future works are discussed.

  • PDF

소프트 스위칭형 삼상 고역율 컨버터의 토포로지 (Novel Soft Swithing Three - Phase High Power Factor converter)

  • 강욱중;정상화;김상돈;곽동걸;전중함;이현우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2221-2223
    • /
    • 1997
  • The proposed converter has a merit of simple controlled circuit because the input current control discontinuously. And it is improve to input power factor that the snubber capacitor's energy regenerate to the AC source side. Specially using the discontinuous current mode in the reactor. This topology is reduced a current /voltage stresses of resonant devices in addition to a partial resonant strategy. The result of simulations of the proposed topology included in this paper.

  • PDF

점탄성층이 부분적으로 삽입된 샌드위치보의 횡진동 감쇠특성 (Behavior of the Flexural Vibration Damping of a Sandwich Beam System with a Partially Inserted Viscoelastic Layer)

  • 박진택;유형원;장석원;최낙삼
    • 대한기계학회논문집A
    • /
    • 제26권2호
    • /
    • pp.225-233
    • /
    • 2002
  • The flexural vibration characteristics of a sandwich beam system with a partially inserted viscoelastic layer have been quantitatively studied using a finite element analysis in combination with a sine-sweep test. Antisymmetric mode shapes of the flexural vibration were visualized by the holographic interferometry and agreed with those calculated by the finite element simulation. Effects of the beam thickness as well as the length and thickness of partial viscoelastic layers on the system loss factor(η$\_$s/) and resonant frequency($\omega$$\_$r/) were significantly large fur the symmetric and antisymmetric modes of the beam system.

Coaxial Feed Wideband CP antenna for RFID Applications

  • Park, Kyu-Dae;Kim, Hwan-Yong
    • Journal of information and communication convergence engineering
    • /
    • 제6권4호
    • /
    • pp.391-395
    • /
    • 2008
  • Wideband terminal and base station is required to serve not only existing 1st and 2nd generation mobile communication systems but also 3rd generation systems. In this paper, we present a feasibility study on coaxial feed compact wideband antenna for UHF RFID reader application. The original antenna was designed for partial discharge detection sensor in high voltage diagnostic system. However, we modified the original prototype to achieve shifted down resonant frequency for wideband wireless communication applications. The experimental result shows good return loss characteristics and radiation patterns except for the total gain at each resonant frequency. The maximum measured gain was 2.45 dBi$\sim$3.18 dBi at 910MHz.

Single Feed Compact Wideband Antenna for Wireless Communication Applications

  • Park, Noh-Joon;Kang, Young-Jin
    • Journal of information and communication convergence engineering
    • /
    • 제6권2호
    • /
    • pp.164-168
    • /
    • 2008
  • Wideband terminal and base station is required to serve not only existing 1st and 2nd generation mobile communication systems but also 3rd generation systems. In this paper, we presents a feasibility study on single feed compact wideband antenna for wireless communication applications including GSM (890-960 MHz), GPS (1575 MHz), DCS (1710-1880 MHz), PCS (1880-1990 MHz), UMTS (1900-2200 MHz), ISM (2400-2480 MHz), IMT2000 and satellite DMB bands. The original antenna was designed for partial discharge detection sensor in high voltage diagnostic system. However, we modified the original prototype to achieve shifted down resonant frequency for wideband wireless communication applications. The experimental result shows good return loss characteristics and radiation patterns except for the total gain at each resonant frequency. The maximum measured gain was 2.45 dBi${\sim}$3.18 dBi at 1710 MHz${\sim}$1880 MHz.

유한요소해석을 이용한 GIS용 AE 센서의 설계와 특성 (Design and Characteristics of AE Sensor for GIS by Finite Element Analys)

  • 홍재일;이병효;김일남;조태경;류주현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.52-55
    • /
    • 2000
  • In this paper, the coupled and the non-coupled vibration mode AE sensor for GIS were simulated by finite element analysis and manufactured, and characterized. The maximum sensitivity was 64.3 dB when the resonant frequency of the coupled vibration mode AE sensor was 166 kHz and the maximum sensitivity was 58.9 dB when the resonant frequency of the non-coupled mode AE sensor was 265 kHz. The coupled vibration mode AE sensor responded higher than the non-coupled vibration mode AE sensor at the partial discharge detection in GIS.

  • PDF