• Title/Summary/Keyword: Partial load condition

Search Result 72, Processing Time 0.038 seconds

Effect of splinting on abutment tooth movement when a distal extension partial denture used(II) (유리단국부의치(遊離端局部義齒) 사용시(使用時) 지태치(支台齒) 동요(動搖)에 대한 Splingting의 효과(效果)(II))

  • Jung, Jong-Hyun
    • Journal of Technologic Dentistry
    • /
    • v.8 no.1
    • /
    • pp.85-90
    • /
    • 1986
  • The effect of splinting on aqbutment tooth distal movement was performed in vitro study. An acrylic resin mandibular model with missing 2nd premolars, molars and a removable partial denture framework were constructed. The roots of the canines, 1st premolars and edentulous ridges were coated with silicone rubber. A modified Ney Surveyor was used for vertical load appkication, and abutment tooth distal movement were measured with a dial gauge with four conditions of splinting methods were tested by applying unilateral vertical loadings. The results are follows; 1. The magnitude of abutment tooth distal movement on the non-load side was less 40$\sim$69% than that occurred on the load side. 2. On the load side, reducing effect of splinting on abutment tooth movement in the condition of load side double abutment(30%), non-load side double abutment(10%), double abutments of both sides(40%) was compared with single abutments of both sides. 3. On the non-load side, reducing effect of splinting on abutment tooth movement in the condition of load side double abutment(5%), non-load side double abutment(22%), double abutments of both sides(59%) was compared with single abutments of both sides. 4. The magnitude of abutment tooth distal movement in the condition of double abutments of both sides was less 40$\sim$59% than that in the condition of single abutments of both sides.

  • PDF

Experimental Study on the Two Phase Thermosyphone Loop with Parallel Connected Multiple Evaporators under Partial Load and Low Temperature Operating Condition (병렬 연결된 다중 증발기 구조 2상 유동 순환형 열사이폰의 부분부하 및 저온운전 특성에 관한 실험적 연구)

  • Kang In-Seak;Choi Dong-Kyu;Kim Taig-young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.11
    • /
    • pp.1051-1059
    • /
    • 2004
  • Two phase thermosyphone loop for electronics cooling are designed and manufactured to test its performance under the partial load and low environment temperature conditions. The thermosyphone device has six evaporators connected parallel for the purpose of cooling six power amplifier units (PAU) independently. The heater modules for simulating PAUs are adhered with thermal pad to the evaporator plates to reduce the contact resistance. There are unbalanced distributions of liquid refrigerant in the differently heated evaporators due to the vapor pressure difference. To reduce the vapor pressure differences caused by partial heating, two evaporators are connected each other using the copper tube. The pressure regulation tube successfully reduces these unbalances and it is good candidates for a field distributed systems. Under the low environment temperature operating condition, such as $-30^{\circ}C$, there may be unexpected subcooling in condenser. It leads the very low saturation pressure, and under this condition there exists explosive boiling in evaporator. The abrupt pressure rise due to the explosive boiling inhibits the supplement of liquid refrigerant to the evaporator for continuous cooling. Finally the cooling cycle will be broken. For the normal circulation of refrigerant there may be an optimum cooling air flow rate in condenser to adjust the given heat load.

A FINITE ELEMENT STRESS ANALYSIS OF THE STRESS DISTRIBUTION AND THE SHOCK ABSORPTION IN AN OSSEOINTEGRATED IMPLANT-NATURAL TOOTH SUPPORTED FIXED PARTIAL DENTURE (골유착성 임프란트와 자연치를 이용한 고정성 국소의치에서 응력분산 및 충격흡수에 관한 유한요소법적 응력분석)

  • Jeong Chang-Mo;Lee Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.4
    • /
    • pp.582-610
    • /
    • 1992
  • The long-term success of any dental implant is dependent upon the optimization of stresses which occur during oral function and parafunction. Especially, it has been suggested that there is an unique set of problems associated with joining an osseointegrated implant and a natural tooth with a fixed partial denture. For this particular case, although many literatures suggest different ways to avoid high stress concentrations on the bone surrounding the implant under static and dynamic loading conditions, but few studies on the biomechanical efficacy of each assertion have been reported. The purpose of this investigation was to evaluate the efficacies of clinically suggested methods on stress distribution under static load and shock absorption under dynamic load, using two dimensional finite element method. In FEM models of osseointegrated implant-natural tooth supported fixed partial dentures, calculations were made on the stresses in surrounding bone and on the deflections of abutments and superstructure, first, to compare the difference in stress distribution effects under static load by the flexure of fastening screw or prosthesis, or intramobile connector, and second, to compare the difference in the shock absorption effects under dynamic load by intramobile connector or occlusal veneering with composite resin. The results of this analysis suggest that : 1. Under static load condition, using an implant design with fastenign screw connecting implant abutment and prosthesis or increasing the flexibility of fastening screw, or increasing the flexibility of prosthesis led to the .increase in height of peak stresses in cortical bone surrounding the implant, and has little effect on stress change in bone around the natural tooth. 2. Under static load condition, intramobile connector caused the substantial decrease in stress concentration in cortical bone surrounding the implant and the slight increase in stress in bone around the natural tooth. 3. Under dynamic load condition, both intramobile connector and composite resin veneering showed shock absorption effect on bone surrounding the implant and composite resin veneering had a greater shock absorption effect than intramobile connector.

  • PDF

A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions (흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구)

  • 박찬우;조현철;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

Finite element stress analysis on supporting bone by tripodal placement of implant fixture (유한요소법을 이용한 임플란트 고정체의 삼각배열에 따른 지지골의 응력 분석)

  • Son, Sung-Sik;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2009
  • Purpose: This study was to propose the clear understanding for stress distribution of supporting bone by use of staggered buccal offset tripodal placement of fixtures of posterior 3 crown implant partial dentures. We realized posterior 3 crown implant fixed partial dentures through finite element modeling and analysed stress effect of implant arrangement location to supporting bone under external load using finite element method. Method: To understand stress distribution of 3 crown implant fixed partial dentures which have 2 different arrangement by finite element analysis. In each model, for loading condition, we applied $45^{\circ}$ oblique load to occlusal surface of crown and applied 100 N for 3 crown individually(total 300 N) for imitating possible oral loading condition. at this time, we calculated Von Mises stress distribution in supporting bone through finite element method. Result: When apply $45^{\circ}$ oblique load to in-line arrangement model, maximum stress result for 100 N for each 3 crown 47.566MPa. In tripodal placement, result for 1mm buccal offset tripodal placement implant model was maximum distributed load 51.418MPa, so result was higher than in-line arrangement model. Conclusion: In stress distribution result by placement of implant fixture, the most effective structure was in-line arrangement. The tripodal placement does not effective for stress distribution, gap cause more damage to supporting bone.

  • PDF

Predictive control based partial switching PFC converter for achieving high efficiency (고효율 구현을 위한 예측제어 기반 부분 스위칭 PFC 컨버터)

  • Choi, Yeong-Jun;Kim, Tae-Jin;Kim, Rae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.11a
    • /
    • pp.1-2
    • /
    • 2014
  • In this paper the partial switching PFC converter which is based on predictive control is proposed. In terms of satisfying the harmonic standard, the predictive control shows a similar performance to the conventional average current mode control PFC in the normal input condition. Moreover, the current harmonic characteristic is insensitive to the distorted input voltage. With predictive control method, novel on-line partial switching strategy is suggested in this paper. Depending on the operating condition, the partial switching PFC converter can boost its output voltage. Also when its efficiency needs to be improved, according to load condition, the partial switching can be achieved. The proposed strategy is proved by the results of FFT and the loss analysis using PSIM 9.0.

  • PDF

Finite element analysis of stress distribution on supporting bone of posterior implant partial dentures by loading location (유한요소 분석을 이용한 하중 위치에 따른 구치부 임플란트 국소의치 지지골의 응력 분포 연구)

  • Son, Sung-Sik;Kim, Young-Jick;Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.29 no.1
    • /
    • pp.93-101
    • /
    • 2007
  • The purpose of this study is to evaluate the effect of three different oblique mechanical loading to occlusal surfaces of posterior implant partial dentures on the stress distributions in surrounding bone, using 3-dimensional finite element method. A 3-dimensional finite element model of a posterior implant partial dentures composed of three unit implants, simplified 3 gold alloy crown and supporting bone was developed according to the design of AVANA self tapping implant for this study. Three kinds of surface distributed oblique loads(300 N) are applied to following occlusal surfaces in the three crowns; 1) All occlusal surfaces in the three crown(load of 300 N was shared to three crown), 2) Occlusal surface of centered crown (load of 300 N was applied to a centered crown), 3) Occlusal surface of proximal crown(load of 300 N was applied to a distal proximal crown). In the results, 141 MPa of maximum von Mises stress was calculated at third loading condition and 98 MPa of minimum von Mises stress was calculated at first loading condition. From the results, location and type of occlusive loading conditions are important for the safety of supporting bone.

  • PDF

The Development of the Condition Monitoring Equipment for distribution Facilities by using the UHF Partial Discharge Sensors (UHF PD 센서를 이용한 배전기기 상태감시장치 개발)

  • Cho, Yong-Jun;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Song, Il-Keun;Lee, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.406-407
    • /
    • 2008
  • This paper is analyzed the internal type UHF partial Discharge sensors and Condition Monitoring Module that be able to monitor the condition of the distribution facilities. It set the PD cell on the inside of 22.9kV load switchgear and then it executed Partial Discharge test. it introduced the result of the test.

  • PDF

A STUDY OF PHOTOELASTIC STRESS ANALYSIS IN THE IMZ IMPLANT-NATURAL 700TH SUPPORTED FIXED PARTIAL DENTURE USING ATTACHMENT WITH OR WITHOUT RIGID CONNECTION (어태치먼트를 이용한 IMZ 임플랜트와 자연치의 연결시 고정유무의 연결형태에 따른 광탄성 응력분석에 관한 연구)

  • Kim, Jeong-Sun;Hwang, Young-Phil;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.1
    • /
    • pp.130-143
    • /
    • 1995
  • The purpose of this study was to analyze the magnitude and distribution of stress using photoelastic model with the rigid connection using T-block attachment and non-rigid connection using key & keyway attachment. The vertical load of 16 Kg was applied on the central fossa of the tooth, the pontic and the implant, and the pattern and distribution under each condition was analyzed. The following results were obtained : 1. In case of vertical load on the central fossa of the implant, the stress was concentrated at the apex of the implant involving the mesial alveolar bone in both fixed partial denture with the rigid connection and that with the nonrigid connection and the stress concentration at the mesial cervical area of the implant was a little more in the nonrigid connection than in the rigid connection. 2. In case of vertical load on the central fossa of the pontic, the stress was concentrated at the apex of 2nd bicuspid in both 3 unit fixed partial denture with nonrigid connection and that with the rigid connection. The stress was more concentrated at the mesial alveolar bone of the implant, but the stress distribution at the natural teeth more favorable at the rigid connection than at the non-rigid connection in case of 4 unit fixed partial denture. 3. In case of vertical load of the central fossa of the 2nd bicuspid, much stress with 3 fringe order was observed at the apex of the 2nd bicuspid in the 3 unit fixed partial denture, but relatively even stress distribution was observed at the apex of the implant, the 1st and 2nd bicuspid, and the adjacent cuspid in the 4 unit fixed partial denture.

  • PDF

A review of effects of partial dynamic loading on dynamic response of nonlocal functionally graded material beams

  • Ahmed, Ridha A.;Fenjan, Raad M.;Hamad, Luay Badr;Faleh, Nadhim M.
    • Advances in materials Research
    • /
    • v.9 no.1
    • /
    • pp.33-48
    • /
    • 2020
  • With the use of differential quadrature method (DQM), forced vibrations and resonance frequency analysis of functionally graded (FG) nano-size beams rested on elastic substrate have been studied utilizing a shear deformation refined beam theory which contains shear deformations influence needless of any correction coefficient. The nano-size beam is exposed to uniformly-type dynamical loads having partial length. The two parameters elastic substrate is consist of linear springs as well as shear coefficient. Gradation of each material property for nano-size beam has been defined in the context of Mori-Tanaka scheme. Governing equations for embedded refined FG nano-size beams exposed to dynamical load have been achieved by utilizing Eringen's nonlocal differential law and Hamilton's rule. Derived equations have solved via DQM based on simply supported-simply supported edge condition. It will be shown that forced vibrations properties and resonance frequency of embedded FG nano-size beam are prominently affected by material gradation, nonlocal field, substrate coefficients and load factors.