• 제목/요약/키워드: Partial insulation

검색결과 462건 처리시간 0.032초

Mica/Epoxy 복합 절연계통의 부분방전 특성과 열화 관계에 관한 연구(I) (A Study on the Relationship between Aging and Partial Discharge Characteristics of the Mica/Epoxy Composite Insulation Systems (l))

  • 강동식;이우영;박정후;곽영순;김길용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.976-979
    • /
    • 1992
  • There are lots of problem which are delaminations and partial discharge of insulation materials in high-voltage rotating machines caused by mechanical, electrical and thermal aging. Several experiments have been aiming at finding the useful diagnostic parameters from the partial discharge characteristics by applying a new measurement techniques. This paper deals with the partial discharge characteristics (pulse height, pulse angle, pulse frequency spectrum and time interval), which may be a useful diagnostic concept in predicting insulation condition of mica/epoxy composite insulation materials, by using several measurement equipments (frequency spectrum analyzer. multichannel analyzer and time interval analyzer).

  • PDF

유중 부분방전의 위치 추정 (Positioning of Partial Discharge in Insulation Oil)

  • 길경석;박대원;장운용;서동환;박희철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1861-1867
    • /
    • 2010
  • This paper described the positioning algorithm of partial discharge in insulation oil by acoustic method for the application of an on-line diagnosis in oil-immersed transformers. In the experiment, five AE sensors having the resonant frequency of 150 kHz were used, and a signal conditioner was fabricated. A needle-plane electrode system which is composed of a needle with a curvature radius of $10{\mu}m$ and a plane electrode with a diameter of 60 mm was installed to simulate partial discharges in insulation oil. From the time difference of arrival (TOA) of acoustic signal, we calculated the location of partial discharge in insulation oil. In the experiment, an algorithm of positioning of PD occurrence by the time difference of arrival was proposed. From the experimental results, the positioning error of PD calculated by three AE sensors was within 4%.

  • PDF

에폭시/고무 계면에서의 결함에 따른 부분방전 특성 (Chracteristics of Partial Discharge Patterns Subjected to Different Defects at the Epoxy/Rubber Interface)

  • 김동욱;김정년;백주흠
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권5호
    • /
    • pp.199-204
    • /
    • 2002
  • In order to recognize the deterioration of insulation system by partial discharge (PD), the characteristics of PD patterns which are occurring at the interface between epoxy and rubber materials in extra high voltage cable joints, have been investigated. The artificial defects such as voids, metal particles, insulation fiber and water impregnated insulation fiber are planted between the interfaces. A high frequency partial discharge detection system was used for measuring PD signals. An analysis of the PD patterns is focused on the shape of PD pattern, phase, width and time-dependence for each artificial defect. The PD Patterns in each defect show the different behaviors and it is suggested that the precise discrimination of PD patterns could be used for the diagnosis of deterioration in the insulation systems.

통계처리와 패턴 인식 기법에 의한 부분방전 해석 (Analysis of Partial Discharge Signals Using Statistical and Pattern Recognition Technique)

  • 변두균;홍진웅
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1231-1234
    • /
    • 2006
  • In this study, we detected electromagnetic waves generated in an enclosed switchgear and applied various statistical methods for detecting signals. We calculated the various statistical factors via the appropriate statistical methods. Further, we used these statistics to recognize the characteristics for each pattern by identifying the partial discharge in each case for normal, proceeding and abnormal states. The characteristics of electromagnetic wave patterns occurred in various states at electric power facilities and were used as an output variable for more efficient diagnosis. In this paper, we confirmed that the pattern of partial discharge signal can be used as one of the factors used to analyze the insulation state and to consider while estimating diagnosis of insulation states by recognizing the signal pattern to intelligence. We will utilize the proposed diagnosis method to determine insulation degradation states.

발전기 고정자 권선의 운전중 부분방전 측정에 의한 절연진단 시스템 개발 (Development of Insulation Diagnosis System by On-Line Partial Discharge Measurement of Generator Stator Windings)

  • 신병철;황돈하;김용주;김정우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1025-1027
    • /
    • 1999
  • Recently, many researches on a diagnosis of stator winding insulation of large generators are reported. They mostly utilize a trend analysis of Partial Discharge (PD). In this paper, a novel on-line monitoring system for an insulation diagnosis is proposed. This system obtains the parameters such as Maximum Partial Discharge Magnitude (QM), Normalized Quantity Number (NQN) and Dynamic Stagnation Voltage (DSV) by continuous on-line monitoring of winding insulation. It is capable of diagnosing the insulation condition by analyzing the trend of PD and utilizing the database built by the system.

  • PDF

고온초전도 케이블의 절연설계를 위한 적층효과 (Multi-layered Effect for the Insulation Design of a HTS Cable)

  • 곽동순;천현권;김해종;조전욱;정순용;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.950-955
    • /
    • 2005
  • For the insulation design of a high temperature superconducting(HTS) cable, three kinds of design method were proposed, which used AC and impulse withstand voltage and partial discharge inception strength. However, the designed insulation thickness by AC and impulse could not be applied to cable fabrication process due to much low electrical breakdown strength. The effect of the multi-layered insulation paper was not considered on the previous insulation design and the insulation thickness by partial discharge inception strength could be applied only. In this paper, the electrical breakdown characteristic, which considered the effect of multi-layered of LPP, was investigated to design the insulation thickness.

Effect of Conductor Radius of Polyesterimide- Polyamideimide Enameled Round Wire on Insulation Breakdown Voltage and Insulation Lifetime

  • Park, Jae-Jun;Shin, Seong-Sik;Lee, Jae-Young;Han, Se-Won;Kang, Dong-Pil
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권3호
    • /
    • pp.146-150
    • /
    • 2015
  • Insulation breakdown voltage and insulation lifetime were investigated in straight lines or twisted pairs with polyesterimide-polyamideimide enameled round wires (EI/AIW ). The enamel thickness was 50 μm and the conducting copper radius was 0.50, 0.75, 1.09, and 1.50 mm, respectively. There were many air gaps in a twisted pair therefore, when voltage was applied to the twisted pair, enamel erosion took place in the air gap area because of partial discharge according to Paschen's law. Insulation breakdown voltage and insulation lifetime were highest in the sample of 0.75 mm conductor radius, which was higher than those values for 0.50 mm or 1.09 and 1.55 mm.

고정자권선의 절연열화 특성분석 (Analysis of the Insulation aging for the stator winding)

  • 오봉근;최교남;한창동;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 전기설비
    • /
    • pp.23-24
    • /
    • 2006
  • Stator winding of hydro generator is gradually deteriorated by multi-stress and steady degradation of insulation results in insulation breakdown. The region where insulation breakdown occurs in stator winding is part where the multi-stress causes the defect of insulation material and electrical stress has been concentrated. Therefore, we judged locations of insulation breakdown to be varied according to various stress factors in service. In this paper, we drew the stator winding of hydro generators which has run for a long time and separated it into 3 parts(central part, end winding part, drawing part) according to the positions laid on the core. We performed electrical and thermal stress on these specimens for 1000 hrs under the same condition, measured the condition regularlyand analyzed the insulation status of each winding by performing partial discharge test. In addition, we analyzed the trend of partial discharge concerning specimens that caused the insulation breakdown during aging.

  • PDF

Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil

  • Park, Dae-Won;Jo, Hyang-Eun;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1468-1473
    • /
    • 2013
  • This paper dealt with the propagation characteristics of acoustic signals produced by partial discharges and the positioning of PD origin in insulation oil to develop insulation diagnostic techniques of oil-immerged transformers. Electrode systems such as needle to plane, plane to plane, and particle electrodes were fabricated to simulate some defects of power transformers. In addition, the frequency spectrum and propagation characteristics of acoustic signals with partial discharge (PD) in insulation oil were analyzed. Although there were differences based on the type of defect, the frequency spectra of the acoustic signals measured by wide and narrow band acoustic emission (AE) sensors were distributed in the range of 50 kHz-400 kHz. Therefore, a narrowband AE sensor is suitable for the diagnosis of oil-immersed power transformers. We could find the position of the PD source with an error margin of 10% in the experiments by calculating the position of the PD occurrence using the time difference of arrival measured by five AE sensors.

절연유-절연지에서 이중 임피던스에 의해 부분방전측정 (Partial Discharge Measurement of Oil-Paper Insulation by Dual Measuring Impeadance)

  • 김광화;류희석;선종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1778-1780
    • /
    • 1996
  • In this paper, we describe the partial discharge measurement with measuring impedance to have two wide frequency band transformers(filters) in the oil-paper and air insulation. The measuring impedance consists of high and low limiting frequency transformers. This measuring impedance could be measured the partial discharge current wave. We have the results that the amplitude partial discharge pulse ratio of low limiting frequency tranformer to high limiting frequency one is varied in the condition(in oil-paper insulation and air) to generate partial discharge.

  • PDF