A Study on the Dielectric Degradation Using Partial Discharge System (부분방전 시스템을 이용한 절연 열화에 관한 연구)

  • 김성홍;이우상;정재용
    • Journal of the Korean Institute of Telematics and Electronics T
    • /
    • v.35T no.1
    • /
    • pp.1-6
    • /
    • 1998
  • Our studies diagnose insulation degradation using the method of PD system. In analysis method of degradation, we make use of degradation information that analyzed the phase angle - PD pulse amplitude - degradation time( $\Phi$- PDA - t) pattern and phase angle- PD pulse number - degradation time( $\Phi$- PDN - t) pattern using statistical operators such as skewness(S), kurtosis(K). Secondly using statically operator such as the center of gravity (G), the gradient of the discharge distribution(C), we have analyzed for the prediction of life which we can be obtained the time, occurred of many pulse of small discharge amplitude.

  • PDF

Location of Partial Discharge in Oil Transformer by means of Ultrasonic measurement (초음파 측정에 의한 변압기내 부분방전 위치측정)

  • Kwak, H.R.;Jeon, H.J.;Kim, J.C.;Hwang, S.J.;Yoon, Y.H.;Kwon, T.W.;Yoon, Y.B.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.415-418
    • /
    • 1991
  • This paper described an instrument for the detection and geometric location of partial discharge(PD) sources in oil transformer. This instrument measures electric current pulse and ultrasonic pulse simultaneously in order to determine the geometric location of PD in transformer. Laboratory experiment systems are made for detection and location of PD in oil transformer. It was observed that there are effects of the barrier, such as insulation papers, silicon steel plate and actual transformer with location and detection of PD in model transformer. Through the laboratory actual test, it was clarified that this measurement device could be used satisfactorily for location of pd in oil transformer.

  • PDF

Recognition of PD Sources in Air by STFT and Stochastic Parameters (STFT 및 통계적 처리에 의한 공기 중 부분방전원 식별)

  • 이강원;박성희;강성화;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.1
    • /
    • pp.101-106
    • /
    • 2004
  • The phenomenon of PD(Partial Discharge) is accompanied by electromagnetic wave which can be detected by UHF(Ultra High Frequency) antenna. The signals obtaining from UHF antenna are very high rapid pulse and have wide band frequency responses. The distribution of PRPD(Phase Resolved Partial Discharge) which consisted of those pulse train can show distinct characteristics of PD sources. But it is not sufficient to discriminate among PD sources. This paper suggests that the stochastic parameters formed by preprocessing of STFT(Short Time Fourier Transform) are good tools for differentiate from PD sources. The stochastic parameters are CC(Cross Correlation) mean value, CC standard deviation, CC skewness, CC kurtosis.

Analysis of Electrical and AE Signals by Treeing Breakdown (트리잉 파괴에 따른 전기 및 AE신호의 분석)

  • Lee, Sang-Woo;Kim, Seung-Gyu;Kim, In-Sik;Lee, Kwang-Sik;Lee, Dong-In
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2335-2337
    • /
    • 1999
  • In this paper, using AE (Acoustic Emission) sensor the electrical and emitted-sound signals are measured by treeing breakdown in the epoxy resin, and the corresponding frequency spectrum of the AE signals are analyzed. We also examined the relationship between partial discharge magnitude and pulse number of AE signals to diagnose the deterioration of the electrical insulation due to treeing breakdown. From these results, a frequency band of AE signals through treeing breakdown was set to about 230 [kHz], and it appeared that pulse number of AE signal was proportional to partial discharge magnitude.

  • PDF

Analysis of Partial Discharge Signal Propagation Characteristics in GIS Using FEM/EMTP (FEM/EMTP를 이용한 GIS내 부분방전 펄스의 감쇠특성 해석)

  • Lee, D.H.;Lee, H.D.;Sin, Y.S.;Lee, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.255-257
    • /
    • 2004
  • This paper was studied electromagnetic field distribution and damping of PD(Partial Discharge) signal in GIS(Gas Insulated Switchgear). Cut-off frequency of electromagnetic wave propagation modes were computed, electromagnetic field distribution of propagation modes in GIS by FEM(Finite Element Method) were simulated and simulated damping characteristic of electromagnetic waves in GIS by EMTP(Electromagnetic Transient Program) when generated PD pulse. Frequency band of $TE_{mn}/TM_{mn}$ modes were determinated by simulation results of electromagnetic field distribution and were discussed optimal position of UHF sensor from this results. Equivalent circuit was used to simulate signal damping of PD pulse in GIS by EMTP and compared with measured results in laboratory of KERI.

  • PDF

Analysis of Partial Discharge Pulse Damping Characteristics in GIS Using EMTP (EMTP를 이용한 GIS내 부분방전 펄스의 감쇠특성 해석)

  • 이도훈;김재철;송승엽;신중은;노광현;김광화
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.103-105
    • /
    • 2003
  • The principle of the ultra-high frequency (UHF) method to detect partial discharge(PD) in GIS is to measure the UHF electromagnetic waves excited by PD pulses. Such electromagnetic waves propagate along the GIS busbar in the TEM-mode, TE-mode, TM-mode. And the coaxial busbar of the GIS acts as a waveguide in which the UHF electromagnetic waves travel. This paper was studied the analysis on damping characteristic of electromagnetic waves excited by PD in GIS and presented the method to yield the cutoff frequency for determine the minimum band of sensor that detect the PD pulse.

  • PDF

Propagation Characteristics of Acoustic Signals Produced by Partial Discharges in an Insulation Oil (유중 부분방전 음향신호의 전달특성)

  • Park, Dae-Won;Cha, Sang-Wook;Cho, Hyang-Eun;Kim, Dong-Geon;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.188-188
    • /
    • 2011
  • This paper describes the propagation characteristics of acoustic signals as a function of distance from the location of partial discharge(PD) occurrence to analyze correlation between discharge magnitude and acoustic signal in insulation oil. We fabricated a decoupler and an amplifier to measure acoustic signals produced by PD. The amplifier has the gain of 40 dB and the frequency bandwidth of 1.6 kHz~1.6 MHz. After a comparative calibration by a standard pulse generator and a coupling capacitor, we analyzed the propagation characteristics of acoustic signals in insulation oil as a function of distance.

  • PDF

Detection and Location of Partial Discharge in Transformers (변압기내 부분방전 탐지 및 위치검출)

  • 곽희노;김재철;황선주;권태원;윤용범
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.6 no.4
    • /
    • pp.53-59
    • /
    • 1992
  • This paper describes an instrument for the detection and geometric location of partial discharge (PD) source in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulses and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used for detecting and locating PD in the transformer.

  • PDF

A Novel Sensitivity Verification Method for the UHF Partial Discharge Detection System in Gas Insulated Switchgear (GIS) (가스절연개폐장치용 UHF 부분방전검출장치의 새로운 감도 측정방법)

  • Gu, Seon-Geun;Park, Gi-Jun;Yun, Jin-Yeol
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.9
    • /
    • pp.450-455
    • /
    • 2001
  • We proposed a new sensitivity verification method for the UHF partial discharge(PD) detection system. Initially, we measure the UHF power induced by 5 pC PD which takes place near UHF sensor. Subsequently, we inject the swept UHF signal from a network analyzer into the GIS and measure the attenuation of the signal along the 71S Both the UHF power by 5 pC PD and the attenuation make it possible to verify the sensitivity and spatial coverage of the PD detection system. This method doesn\`t require the calibration of injected pulse type UHF signal into the GIS and makes us precisely measure the attenuation in frequency domain.

  • PDF

Partial Discharge Measuring System of Mold Transformer (몰드변압기의 부분방전 측정 시스템)

  • Kang, Dong-Sik;Sun, Jong-Ho;Lim, Tae-Hoon;Hwang, Don-Ha;Kim, Yong-Joo;Kweon, Dong-Jin;Oeu, Soo-Young
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1891-1893
    • /
    • 2003
  • In order to development of diagnosis system for mold transformer, partial discharge measurement technique is recommended the best effective method for the evaluation of insulation condition. However, this technique was not applied to mold transformer yet. The purpose of this paper is to describe the method of partial discharge measurement for mold transformer. As we reviewed on-line test technique, sensor, transducer of pulse signal processing, set-up of test circuit for loading back device and now testing.

  • PDF