• Title/Summary/Keyword: Partial discharge energy

Search Result 52, Processing Time 0.028 seconds

Measurement of Energy bands of the MgO Layer in AC-PDPs

  • Jeoung, S.J.;Lee, H.J.;Son, C.G.;Kim, J.H.;Park, E.Y.;Hong, Y.J.;You, N.L.;Lee, S.B.;Han, Y.G.;Jeoung, S.H.;Song, K.B.;Moon, M.W.;Oh, P.Y.;Choi, E.H.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.906-909
    • /
    • 2006
  • The secondary electron emission coefficient $({\gamma})$ of the cathode is an important factor for improving the discharge characteristics of AC-PDPs because of its close relationship to discharge voltage. In AC-PDPs, MgO is most widely used as a surface protective layer. In this experimental, we have investigated the electronic structure of the energy band structure of the MgO layer responsible for the high ${\gamma}$. The MgO layers have been deposited by electron beam evaporation method, where the $O_2$ partial pressures have been varied as 0, $5.2{\times}10^{-5}$ torr, $1.0{\times}10^{-4}$ torr, and $4.1{\times}10^{-4}$ torr, in this experiment. It is noted that work function that is energy gap between surface and first defect level of MgO layer has the lowest value for the highest O2 partial pressure of $4.1^{\ast}10^{-4}$ Torr.

  • PDF

Production of Hydrogen from Methane Using a 3 Phase AC Glidarc Discharge (3상 교류 부채꼴 방전을 이용한 메탄으로부터 수소 생산)

  • Kim, Seong-Cheon;Chun, Young-Nam
    • Journal of Hydrogen and New Energy
    • /
    • v.18 no.2
    • /
    • pp.132-139
    • /
    • 2007
  • Popular techniques for producing synthesis gas by converting methane include steam reforming and catalyst reforming. However, these are high temperature and high pressure processes limited by equipment, cost and difficulty of operation. Low temperature plasma is projected to be a technique that can be used to produce high concentration hydrogen from methane. It is suitable for miniaturization and for application in other technologies. In this research, the effect of changing each of the following variables was studied using an AC Glidarc system that was conceived by the research team: the gas components ratio, the gas flow rate, the catalyst reactor temperature and voltage. Glidarc plasma reformer was consisted of 3 electrodes and an AC power source. And air was added for the partial oxidation reaction of methane. The result showed that as the gas flow rate, the catalyst reactor temperature and the electric power increased, the methane conversion rate and the hydrogen concentration also increased. With $O_2/C$ ratio of 0.45, input flow rate of 4.9 l/min and power supply of 1 kW as the reference condition, the methane conversion rate, the high hydrogen selectivity and the reformer energy density were 69.2%, 36.2% and 35.2% respectively.

The Flashover Characteristics by the Margins on Metalized Polypropylene Films in Air (금속증착 폴리프로필렌 필름의 마진에 따른 기중 연면방전 특성)

  • Ryu, Sung-Sic;Kim, Young-Chan;Jung, Yong-Ki;Jung, Jong-Wook;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2386-2388
    • /
    • 1999
  • This paper describes the surface discharge characteristics which can be used as data to determine the optimumal length in margin which plays an important role in improving the energy density and the life-time of high voltage capacitors. In this experiment, the margin of metalized polypropylene films(MPPFs) is varied in length in order to measure and analyze flashover voltages and partial discharge inception voltages (PDIVS). As a result, the flashover voltage and the PDIV are increased with margin and tracking was observed.

  • PDF

Lubrication Characteristics Between the Vane and the Rolling Piston in a Rotary Compressor Used for Refrigeration and Air-Conditioning Systems

  • Jung, Jae-Youn;Oh, Seok-Hyung;Cho, Ihn-Sung
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.562-568
    • /
    • 2001
  • The rolling piston type-rotary compressor has been widely used for refrigeration and air-conditioning systems due to its compactness and high-speed operation. The present analysis is part of a research program directed toward maximizing the advantages of refrigerant compressors. The study of lubrication characteristics in critical sliding components is essential for the design of refrigerant compressors. Therefore, theoretical investigation of the lubrication characteristics of a rotary compressor used for refrigeration and air-conditioning systems was studied. The Newton-Raphson method was used for the partial elastohydrodynamic lubrication analysis between the vane and the rolling piston of a rotary compressor. The results showed that the rotational speed of a shaft and the discharge pressure significantly influence the friction force and the energy loss between the vane and the rolling piston.

  • PDF

Evaluation of Plasma Characteristics for Hg-Ar Using LIF (LIF를 이용한 Hg-Ar 플라즈마 특성 평가)

  • Moon, Jong-Dae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.2
    • /
    • pp.79-83
    • /
    • 2008
  • In this paper, we introduced a LIF measurement method and summarized the theoretical side. When an altered wavelength of laser and electric power, lamp applied electric power, we measured the relative density of the metastable state in mercury after observing a laser induced fluorescence signal of 404.8nm and 546.2nm, and confirmed the horizontal distribution of plasma density in the discharge lamp. Due to this generation, the extinction of atoms in a metastable state occurred through collision, ionization, and excitation between plasma particles. The density and distribution of the metastable state depended on the energy and density of plasma particles, intensely. This highlights the importance of measuring density distribution in plasma electric discharge mechanism study. The results confirmed the resonance phenomenon regarding the energy level of atoms along a wavelength. change, and also confirmed that the largest fluorescent signal in 436nm, and that the density of atoms in 546.2nm ($6^3S_1{\to}6^3P_2$) were larger than 404.8nm ($6^3S_1{\to}6^3P_2$). According to the increase of lamp applied electric power, plasma density increased, too. When increased with laser electric power, the LIF signal reached a saturation state in more than 2.6mJ. When partial plasma density distribution along a horizontal axis was measured using the laser induced fluorescence method, the density decreased by recombination away from the center.

Measurement of Ion Energy Distribution using QMS & Ionization Enhancement by usign Magnetic Field in Triod BARE (자장을 이용한 이온화율 증대형 삼극형 BARE에서 이온화율의 증대경향과 QMS를 이용한 이온의 에너지 분포 측정)

  • 김익현;주정훈;한봉희
    • Journal of Surface Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.119-124
    • /
    • 1991
  • Recently, the trend of research in hard coating is concentrate on developing the process of ionization rate under low operating pressure, to get the thin film with high adhesion and dense microstructures. In this study ionization rate enhancement type PVD process using permanent magnet is developed, which enhances the ionization rate by confining the plasma suppressing the wall loss of electron. By the result to investigate the characteristic of glow discharge, the ionization rate of this process is enhanced about twice as high as that of triod BARE process (about 26%), and more dense TiN microstructures are obtained in this process. Cylindrical ion energy analyzer is made and attached in front of a quadrupole mass filter for the analysis of the energy distribution of reactive gas and activated gas ions from the plasma zone. To analyze the operation mechanism of ion energy analyzer, computer simulation is performed by calculation the electric field environment using finite element method. By these analyses of ion energy distribution of outcoming ions from the plasma zone, it is found that magnetic field enhances ion kinetic energy as well as ionization rate. The other results of this study is that the foundation of feed-back system is constructed, which automatically control the partial pressure of reactive gas. In can be possible by recording the data of mass spectrum and ion energy analysis using A-D converter.

  • PDF

Modification of DC Flashover Voltage at High Altitude on the Basis of Molecular Gas Dynamics

  • Liu, Dong-Ming;Guo, Fu-Sheng;Sima, Wen-Xia
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.625-633
    • /
    • 2015
  • The effect of altitude on thermal conduction, surface temperature, and thermal radiation of partial arc was investigated on the basis of molecular gas dynamics to facilitate a deep understanding of the pollution surface discharge mechanism. The DC flashover model was consequently modified at high altitude. The validity of the modified DC flashover model proposed in this paper was proven through a comparison with the results of high-altitude simulation experiments and earlier models. Moreover, the modified model was found to be better than the earlier modified models in terms of forecasting the flashover voltage. Findings indicated that both the thermal conduction coefficient and the surface thermodynamics temperature of partial arc had a linear decrease tendency with the altitude increasing from 0 m to 3000 m, both of which dropped by approximately 30% and 3.6%, respectively. Meanwhile, the heat conduction and the heat radiation of partial arc both had a similar linear decrease of approximately 15%. The maximum error of DC pollution flashover voltage between the calculation value according to the modified model and the experimental value was within 6.6%, and the pollution flashover voltage exhibited a parabola downtrend with increasing of pollution.

A Study on the Electrochemical and Thermodynamic Properties of Hydrogen Absorbing Alloys (수소저장합금의 전기화학 및 열역학적 특성에 관한 연구)

  • Park, Chan-Kyo;Cho, Tae-Hwan
    • Journal of Hydrogen and New Energy
    • /
    • v.5 no.2
    • /
    • pp.65-71
    • /
    • 1994
  • Electrochemical and thermodynamic properties of $MmNi_5$ and the related alloys for nickel-metal hydride battery(Ni-MH) were studied in terms of the equilibrium hydrogen pressure. $MmNi_5$ alloy with high equilibrium hydrogen pressure(10~20atm at room temperature), which is usually difficult to charge, was substituted for Al in part. Partial substitution of Al made not only the equilibrium pressure to be reduced remarkably, but also the enthalpy change depending on the formation of metal hydride to be agreed to the value in gas phase reaction and electrochemical reaction. Besides the composition of Al which can be given the maximum discharge capacity was turned out to be between the 0.5~1.0 atoms of Al.

  • PDF

The study of partial discharge diagnostic in oil type transformer using the hybrid sensors (하이브리드센서를 이용한 유입식변압기 대한 고장진단 사례연구)

  • Oh, Seung-Chan;Lee, Nam-Ho;Lee, Ho-Heung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2083-2084
    • /
    • 2011
  • 본 논문에서는 유입식변압기에 대한 부분방전진단방법에 있어 초음파센서 및 HFCT(High Frequency Current Transducer)센서의 동시측정방법 이용하여 유입식변압기 내부에서 발생한 부분방전신호의 위치추적 및 현장잡음에서의 유효한 부분방전 위치추적을 위한 하이브리드 센서적용방법을 제안하고 국내외 부분방전진단시험을 통하여 제안한 진단방법을 이용한 부분방전위치추적에 대한 고장진단사례를 소개하고자 한다.

  • PDF

The degradation of insulation oil in power transformers by the evolution of gases, Tan $\delta$, moisture and total acid number (가스량, Tan $\delta$, 수분량, 전산가에 의한 유침 전력 변압기의 열화현상에 관한 연구)

  • Choi, Jong-Kab;Han, Min-Koo;Kwon, Tae-Won;Yun, Yong-Bum
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.159-163
    • /
    • 1989
  • The various degradation phenomena, such as the evolution of gases, tan $\delta$, moisture content and total acid number in power transformer insulation oil, have been measured and analyzed. Mineral oil has been degraded at laboratory by the forced thermal stress of $60^{\circ}C$ and $90^{\circ}C$ respectively. Thermal aging oil has been degraded about 17, 34, 72 days. Also, we extracted insulation oil from working transformers. We measured gases dissolved in samples, tan $\delta$, moisture content, total acid number. Activation energy and resistivity is calculated from them. It is found that gases and tan $\delta$ increases as partial discharge and total acid number increases and that conductivity of the sample increases as activation energy increases.

  • PDF