• 제목/요약/키워드: Partial discharge(PD)

검색결과 502건 처리시간 0.028초

Partial Discharge Localization Based on Detailed Models of Transformer and Wavelet Transform Techniques

  • Hassan Hosseini, Seyed Mohammad;Rezaei Baravati, Peyman
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1093-1101
    • /
    • 2015
  • Partial Discharge (PD) is a physical phenomenon, which causes defects and damages to the insulation. This phenomenon is regarded as the most important source of fault and defect in power transformers. Therefore, methods of high speed and precision are considered of special importance for the maintenance of transformers in localization of the origin of partial discharge. In this paper, the transformer winding is first modeled in a transient state by using RLC ladder network and multiconductor transmission line (MTL) models. The parameters of the two models were calculated by Ansoft Maxwell software, and the simulations were performed by Matlab software. Then, the PD pulses were applied to the models with different widths of pulses. With regard to the fact that the signals received after the application of PD had a variable frequency nature over time, and based on the wavelet transform and signal energy, a new method was presented for the localization of PD. Ultimately; the mentioned method was implemented on a 20 kV winding distribution transformer. Then, the performances of the models used in this paper, including RLC and MTL models, were compared in different frequency bands for the correct distinction of partial discharge location.

배전급 CNC케이블의 결함 종류에 따른 부분방전 분포특성 (Partial Discharge Distribution Characteristics along Defect of CNC Cable)

  • 윤재훈;강성화;최한식;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.102-102
    • /
    • 2010
  • A purpose of this paper is to recognize partial discharge pattern for cable insulation. The classification of PD sources was widely studied for two decades. this research sought to use the partial discharge detection method, and to diagnose the interface of cable, which is deemed vulnerable of cable systems. A research abalyzed faults that can occur in the interface of cable joint as well as accident mechanisms, manufactured test 22.9kV CNC cable, invented artificial faults and carried out partial discharge detection experiments. As a result, various PD pattern along defect measured and distinguished.

  • PDF

GIS 부분방전 신호와 도착 시간차 분석을 통한 PD발생 위치 추적 (Partial Discharge Position Tracking Method using a GIS Partial Discharge Signal and Arrival Time Difference)

  • 최문규;차한주
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1297-1301
    • /
    • 2013
  • This paper analyzes of PD occurrence position through an analysis of the arrival time difference between the GIS partial discharge signal. Because of GIS (Gas Insulated Switchgear) is a facility very important power equipment and as part of the equipment that make up the power system, the stabilization of the power industry, which accounted for 88.5% share of GIS substation in the form of a substation is an important equipment for power supply. In the situation where we are gradually expanding the need for preventive diagnosis in order to improve the efficiency of equipment management and failure prevention for Preventive diagnosis. In this paper as a method for extracting pre-defect of failure of GIS Apply the average value method of calculating the 5 times each using a pulse of the first time of the second pulse (${\Delta}t$) with an oscilloscope generation position PD(Partial Discharge). the results of GIS internal inspection, the partial discharge of the actual the position of the partial discharge was confirmed with an accuracy of about 82% of positions. Arrival time difference in the most effective manner if the partial discharge of GIS internal occurs by applying the averaging method and TOA(Time of arrival) method, the partial discharge occurs you through the measurement and analysis of PD signal occurs was confirmed in the experiment are presented and diagnostic methods location tracking.

양수발전소 발전-전동기 운전중 감시 시스템의 개발 (Development of On-Line Monitoring System for Pumped Storage Generator/Motor)

  • 김희동;주영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권3호
    • /
    • pp.168-174
    • /
    • 2004
  • On-line monitoring system(OMS) has been developed for the pumped storage generator/motor The OMS is applied to diagnosis of the PD(partial discharge) activity of stator insulation, the shorted-turn of rotor winding and the variation of the air-gap between stator and rotor. The OMS consists of DAS(data acquisition system), main server system, gateway and display PC. The DAS measures the PD, the shorted-turn and air-gap from three sensors installed on the generator/motor. The gateway controls the data which sent by DAS. The main server system saves the data, analyzes the data and conducts the diagnostic algorithm. The display PC shows the diagnostic results of partial discharge, shorted-turn and air-gap. Field tests were conducted using PDA(partial discharge analyzer). The results of the OMS and PDA measurements can be directly correlated with normalized quantity number(NQN), PD magnitude(Qm) and PD pattern.

Partial Discharge Properties of PET Film with Carbon Black

  • Lee, Young-Hwan;Lee, Jong-Chan;Park, Yong-Sung;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.1-4
    • /
    • 2004
  • This paper presents an investigation of the phase-resolved partial discharge (PD) pattern of PET (Poly Ethylene Telephthalate) films with carbon black particles. The phase-resolved PD pattern and statistical parameter from PET samples according to the number of included semiconductor particles were measured. The measurement system consisted of a conventional PD detector using a digital signal processing technique. The partial discharge patterns of the PET films that include the semiconductor particles were investigated to simulate an actual situation that may exist in the cable. In addition, difference of PD patterns between semiconducting particles in PET films and artificial voids was studied. The relationship between the numbers of semiconductor particles in PET films was discussed through the difference of Ψ-q-n distribution and statistical analysis.

웨이브렛 변환을 이용한 GIS의 부분방전 검출 알고리즘에 관한 연구 (A Study on the Algorithm for Detection of Partial Discharge in G15 Using Wavelet Transform)

  • 강진수;김철환
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권1호
    • /
    • pp.25-34
    • /
    • 2003
  • Gas insulated switchgear(GIS) is an important equipment in a substation. It is highly desirable to measure a partial discharge(PD) in GIS which is a symptom before insulation breakdown occurs. The issue is that the PD signal is weak and sensitive to external noise. In this paper, the algorithm for detection of PD in GIS using wavelet transform is proposed. The wavelet transform provides a direct quantitative measure of spectral content, "dynamic spectrum", in the time-frequency domain. The recommended mother wavelet is 'Daubechies' wavelet. 'db4', the most commonly applied mother wavelet in the power quality analysis, can be used most properly in disturbance phenomena which occurs rapidly for a short time. Through the procedure of wavelet transform, noise extraction and reconstruction, the signal is Analyzed to determine the magnitude of PD in GIS. In experimental results, we can know that partial discharge is exactly detected in combination of Dl and D2 using wavelet transform.transform.

저밀도 폴리에틸렌에서 전기트리에 수반되는 부분방전의 특성 (Properties of Partial Discharge accompanying with Electrical Tree in LDPE)

  • 이광우;박영국;강성화;장동욱;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.234-238
    • /
    • 1999
  • The correlation between shape of electrical trees and partial discharge(PD) pulses in low density polyethylene(LDPE) were discussed. We observed growth feature of electrical tree by using optical microscope. On the basis of experimental results of measurements of trees occurring in the needle-plane arrangement with needle shape void and without needle shape void , statistical quantities are derived, which are relevant to PD pulse amplitude and phase. The PD quantities detected by partial discharge detector. we were analyzed q-n distribution pattern and $\psi$ -q-n distribution pattern. In this experiment, electrical trees in the needle-plane arrangement with needle shape void propagated branch type tree and in the needle-plane arrangement without needle shape void propagated bush type tree

  • PDF

가스절연모선(GIB)에서 전자파 방전신호의 모드별 군속도 차이를 이용한 방전위치 산정기법 (Partial Discharge Location Method using Group Velocity Difference of Modes in a Electromagnetic Partial Discharge Signal in Gas Insulated Bus)

  • 구선근;주형준;박기준;한기선;윤진열
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2184-2188
    • /
    • 2007
  • We developed a novel method of partial discharge(PD) location based on the fact that the waveform of PD signal propagate along the GIB (Gas Insulated Bus) is composed of several modes of electromagnetic wave with different group velocities and cut-off frequencies. From the PD waveform, measured at a broadband PD sensor attached on the GIB, we could derive arrival time and frequency components of different modes using the short term Fourier transform or etc. After the group velocities of different modes are calculated, the location of the PD source could be estimated. To show the effectiveness of this new locating method in a real on site application, we used this method to locate the position of a PD source at a 76 m long 345 kV GIB substation. The estimated location of the PD source using the method proposed above was in good agreement with the actual location found from the inspection result of internal component in the GIB with 2.4% of the estimation error.

이종 비유전율에서 TDR을 이용한 PD발생 위치 추적방법 (Using the TDR in Dielectric for Partial Discharge Signals Detection Method)

  • 최문규;차한주
    • 전기학회논문지
    • /
    • 제64권9호
    • /
    • pp.1374-1379
    • /
    • 2015
  • Time Domain Reflectometry(TDR) using microwave bands, including broadband spectrum that occurs at the range of rates that start between partial discharge position it easier to make the techniques that could be measured. Partial discharge in the Gas Insulated Switchgear(GIS), the dielectric constant in the band more than GHz different the insulating material if you want to organize, and the insulating material regardless of how partial discharge position in the SF6 gas Partial Discharge by applying the heritability estimated its position, but the position error occurred about 23 percent of the existing way, correct in not suitable location tracking the outbreak PD. This technique the rate of other dielectric that make up the power apparatus heterology is measured at the function to slow the progression of the electromagnetic waves apart by calculating the partial discharge as the location, A simple way to track. Dielectric using other methods proposed new structure can calculate the speed of heritability PD is occurring can measure.

고압전동기 운전중 부분방전 감시 시스템 개발 (Development of On-Line Partial Discharge Monitoring System in High Voltage Motors)

  • 김희동;공태식;주영호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1175-1178
    • /
    • 2004
  • On-line partial discharge(PD) monitoring system has been developed to monitor in operating large motor stator insulations. This system makes use of remote diagnosis techniques for the evaluation of PD activity in the control center of thermal power plant. This system can be remotely accessed via a modem to build database, analyze status and interpret the pattern of PD activity. A personnel computer is generally connected to ten motors to continuous measurement of the PD activity. The test data can be easily interpreted by a maintenance staff. For assessing the condition of stator winding in motors, this system ensures a reliable measurement and accurate estimation. Capacitive couplers used for on-line PD measurement have been 80pF. The maximum PD magnitude(Qmax), PD pattern and normalized quantity number(NQN) were performed by this system.

  • PDF