• 제목/요약/키워드: Partial contact

검색결과 224건 처리시간 0.029초

On the Contact of Partial Rotor Rub with Experimental Observations

  • Park, Yeon-Sun
    • Journal of Mechanical Science and Technology
    • /
    • 제15권12호
    • /
    • pp.1630-1638
    • /
    • 2001
  • Partial rotor rub occurs when an obstacle on the stator of a rotating machinery disturbs the free whirling motion of the rotor, which is more common than full annular rub among the cases of rubbing in rotating machinery. The intermittent contacts and friction during partial rotor rub makes the phenomenon complex. The several nonlinear phenomena of superharmonics, subharmonics, and jump phenomenon are demonstrated for the partial rub using an experimental apparatus in this study. The orbit patterns are also measured experimentally. In order to explain the phenomena of partial rotor rub, the analytical model for the contact between the rotor and stator should be chosen carefully. In this respect, a piecewise-linear model and a rebound model using the coefficient of restitution are investigated on the basis of the experimental observations. Also, Numerical simulations for the two models of contact are done for the various system parameters of clearance, contact stiffness, and friction coefficient. The results show that the piecewise-linear model for partial rotor rub is more plausible to explain the experimental observgations.

  • PDF

부분회전마멸에서의 접촉모델 (Contact Model of Partial Rotor Rub)

  • 최연선;배철용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.277-282
    • /
    • 2001
  • Partial rotor rub occurs when an obstacle on the stator of a rotating machinery disturbs the free whirling motion of a rotor, which is more common than full annular rub for the cases of rubbing in rotating machinery. The nonlinearity due to the intermittent contacts and friction during partial rotor rub makes the phenomenon complex. The several nonlinear phenomena of superharmonics, subharmonics, and jump phenomenon are demonstrated for the partial rub using an experimental apparatus in this study. A piecewise-linear model and a rebound model using the coefficient of restitution are investigated on the basis of experimental observations in order to adopt as an analytical model of the contact between the rotor and stator during whirling motion. The contact stiffness, coefficient of restitution, and friction coefficient for the contact during partial rub are calculated from the comparison between the numerical simulation and the experimental results. Also, the numerical simulations for the model of partial rub are done for the various system parameters of clearance, contact stiffness, and friction coefficient in order to find the nonlinear behavior of partial rotor rub.

  • PDF

배선에서의 반단선 및 접촉불량에 대한 열적 전조 DB구축 (Development of Thermal Precursor DB for Partial Disconnection and Poor Contact on Electrical Wire)

  • 김두현;김성철;이종호;강동규
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.30-36
    • /
    • 2009
  • This paper aims at the precursor analysis and DB development of electrical fires based on thermal and current signals for partial disconnection and poor contact on electric wires through experiments and simulations. Also, DB system required for developing the precursor DB with these data was studied and designed. Firstly, in case of partial disconnection, characteristics were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF and IV electric wires. Based on the characteristics, About 351 partial disconnection precursor patterns were generated by the thermal analysis for electric wire according to deterioration time under normal state and 200% overload state of rated current. Secondly, in order to develop poor contact precursor patterns, temperature value and the current signal were considered. In simulating the poor contact situation on connector area of MCCB, connection torque was changed. Through the experimental analysis, about 251 poor contact precursor patterns were generated. Finally, Using thermal precursor patterns obtained by partial disconnection and poor contact, electrical fire thermal precursor DB was developed.

Study on vibration energy characteristics of vehicle-track-viaduct coupling system considering partial contact loss beneath track slab

  • Liu, Linya;Zuo, Zhiyuan;Zhou, Qinyue;Qin, Jialiang;Liu, Quanmin
    • Structural Engineering and Mechanics
    • /
    • 제75권4호
    • /
    • pp.497-506
    • /
    • 2020
  • CA mortar layer disengagement will give rise to the overall structural changes of the track and variation in the vibration form of the ballastless track. By establishing a vehicle-track-viaduct coupling analysis and calculation model, it is possible to analyze the CRTS-I type track structure vibration response while the track slab is disengaging with the power flow evaluation method, to compare the two disengaging types, namely partial contact loss at one edge beneath track slab and partial contact loss at midpoint beneath track slab. It can also study how the length of disengaging influences the track structures vibration power. It is showed that when the partial contact loss beneath track slab, and the relative vibration energy level between the rail and the track slab increases significantly within [10, 200]Hz with the same disengaging length, the partial contact loss at one edge beneath track slab has more prominent influence on the vibration power than the partial contact loss at midpoint beneath track slab. With the increase of disengaging length, the relative vibration energy level of the track slab grows sharply, but it will change significantly when it reaches 1.56 m. Little effect will be caused by the relative vibration energy level of the viaduct. The partial contact loss beneath the track slab will cause more power distribution and transmission between the trail and track slab, and will then affect the service life of the rail and track slab.

친환경 가스 중 전극과 고체절연체의 불량접촉에 관한 절연진단연구 (Study on Insulation Diagnosis of Poor Contact between Electrode and Solid Insulator in Eco-Gas)

  • 임동영;최은혁;배성우;최상태;이광식;최병주
    • 조명전기설비학회논문지
    • /
    • 제29권10호
    • /
    • pp.97-103
    • /
    • 2015
  • This paper presents the characteristics of partial discharge and radiated electromagnetic waves in the existence of a poor contact for the insulation diagnosis of eco-friendly power equipment. AC surface discharge experiment was conducted to simulate the poor contact between a hive voltage electrode (anode) and a solid insulator in $N_2/O_2$ mixture gas under a non-uniform field. The partial discharge voltage to be measured at 0.3MPa increased with the increase of the poor contact gap and was saturated with the gap. In addition to the partial discharge characteristics, it was verified that the defect of the poor contact can be diagnosed using the radiated electromagnetic waves due to the partial discharge, which measured by a biconical EMC antenna and a spectrum analyzer.

임플란트 국소의치 금나사의 3차원 유한요소법 접촉응력 분석 (3D Dimensional Finite Element Analysis of Contact Stress of Gold Screws in Implant Partial Denture)

  • 이명곤
    • 대한치과기공학회지
    • /
    • 제35권4호
    • /
    • pp.303-312
    • /
    • 2013
  • Purpose: In this research, non-linear three dimensional finite element models with contact elements were constructed. For the investigations of the distributions of contact stresses, 3 units fixed partial dentures model were studied, especially on the interface of the gold screw and cylinder, abutment screw. Methods: 3 types of models were constructed ; the basic fixed partial denture in molar region with 3 units and 3 implants, the intermediate pontic fixed partial denture model with 3 units and 2 implants, and the extension pontic fixed partial denture model with 3 units and 2 implants. For all types, the external loading due to chewing was simulated by applying $45^{\circ}$ linguo-buccal loading of 300 N to the medial crown. For the simulation of the clamping force which clinically occurs due to the torque, thermal expansion was provided to the cylinder as a preload. Results: Under 300 N concentrated loading to the medial crown, the maximum contact stress between abutment screw and gold screw was 86.85~175.86MPa without preload, while the maximum contact stress on the same area was 25.59~57.84MPa with preload. Conclusion: The preloading affected the outcomes of the finite element stress analysis. Reflecting the clinical conditions, the preloading conditions should be considered for other practical study utilizing FEA. For the study of the contact stresses and related motions, various conditions, such as frictional coefficient changes, gap between contact surfaces, were also varied and analyzed.

원통 프런지 연삭공정의 감시/제어 시스템 (Monitoring/Control System for Cylindrical Plunge Grinding)

  • 김선호;정병철;안중환
    • 한국정밀공학회지
    • /
    • 제12권9호
    • /
    • pp.66-73
    • /
    • 1995
  • This paper presents monitoring and control system to decrease non-production time such as air grinding and partial contact in cylindrical plunge grindings. The 4-stage model of the plunge grinding process is proposed according to the state of contact between grinding wheel and workpiece; air grinding, partial contact, entire contact and spark out. Experimentally it is seen that the AE sensor and ultrasonic sensor are very effective to detect the grinding states. Monitoring and control algorithm using recognized grinding process was introduced and a experiment were conducted to verify the developed system.

  • PDF

The Influence of Contact Shape on the Slip Regime in Contact-induced Failure

  • Kim, Hyung-Kyu;Kang, Heung-Seok;Song, Kee-Nam
    • KSTLE International Journal
    • /
    • 제2권2호
    • /
    • pp.85-92
    • /
    • 2001
  • The variation of contact traction induced by different contact shapes is studied experimentally and theoretically. Considerations fer the contact shape are rounded, truncated and truncated with rounding punches. A fretting wear experiment is conducted with the contact configuration of the strip on the tube specimens. The strip specimen is pressed to form the end profile of a rounded and truncated with rounding punches shape. Wear on the tube is investigated, which is regarded as the slip region of the contact surface. Taken into consideration is the general solution of the normal traction in the case of the indentation by a punch with its end profile of the combination of parabolas. Then, partial slip solution is obtained numerically, which is compared with the wear on the tube. The radius of the rounding and the obliquity of the edge truncation affect the tractions considerably. It is found that the proper choice of the end profile can restrain the contact-induced failure such aswear.

  • PDF

지르칼로이-4 튜브 및 지지부의 접촉조건과 미끄럼 상태의 천이 (Contact Condition of Zircaloy-4 Tube and Support and Transition of Slip Regime)

  • 김형규;강흥석;윤경호;송기남
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2001년도 제33회 춘계학술대회 개최
    • /
    • pp.81-88
    • /
    • 2001
  • To study the influence of the shape of contacting bodies (especially the end profile) on slip regime, wear test is conducted in the case of the contact between tube and support. Two different end profiles of the support are used such as truncated wedge and rounded punch. During the test, 10, 30 and 50 N are applied as normal force and slip displacement varies between 10-200 $\mu\textrm{m}$. The tube and the support specimens are made of Zircaloy-4 and a specially designed wear tester is used. Tests are carried out in air at room temperature. Wear on the tube is examined by measuring microscope. Partial and gross slip regimes are classified from the observed wear shape. Surface roughness tester is also used to measure the wear depth and contour, from which wear volume is evaluated. The transition from partial to gross slip is also investigated by investigating the considerable increase of wear volume. From the result, the boundary between the partial and the gross slip is newly determined in the conventional fretting map for the present specific contact configuration. Since the transition is related with the amount of energy dissipation from the contact surface so is wear, it is regarded that wear can be restrained by designing a proper shape of support.

  • PDF

자연치열자와 가철성 국소의치 장착자의 저작효율과 근활성도에 관한 비교 연구 (A STUDY ON MASTICATORY PERFORMANCE AND MUSCLE ACTIVITY IN REMOVABLE PARTIAL DENTURE WEARERS)

  • 백진;박남수
    • 대한치과보철학회지
    • /
    • 제36권1호
    • /
    • pp.81-103
    • /
    • 1998
  • The purpose of this study was to compare and evaluate the differences in masticatory performance, muscle activity, and patterns of occlusal contact between persons with natural dentition and removable partial denture wearers. Twenty healthy adult subjects with more than 28 teeth and thirteen removable partial denture wearers that classified Kennedy classification I was selected. The degree of pulverized rice and peanut was measured and analyzed by means of sieving method to compare the masticatory performance. For the muscle activity, EMG was recorded in selected muscles(Temporalis and masseter muscle) during mastication and resting state. The occlusal record in maximal intercuspation was taken with a silicone occlusal bite registration material for analysis of the patterns of occlusal contact. The obtained results were as follows: 1. When chewed peanuts, masticatory performance ratio at 10-sieve size was 81.31% in natural dentition group. In removable partial denture wearer, 27.01% without RPD and 69.09% with RPD. When chewed rice, 42.04%, 11.87%, and 21.58%, respectively. The differences of masticatory performance ratio between groups were statistically significant at the 0.05 level. 2. The mean EMG value in resting state was $1.06{\mu}V$ on temporal muscle, $0.98{\mu}V$ on masseter muscle in natural dentition group. In removable partial denture wearers, $1.13{\mu}V$ on temporal muscle, $1.05{\mu}V$ on masseter muscle without RPD and $1.11{\mu}V$ on temporal muscle, $1.04{\mu}V$ on masseter muscle with RPD. 3. The mean EMG value during mastication was $45.64{\mu}V$ in natural dentition group, and in removable partial denture wearers, $22.06{\mu}V$ without RPD and $31.01{\mu}V$ with RPD when chewed peanuts. When chewed rice, $45.24{\mu}V,\;25.53{\mu}V\;and\;32.14{\mu}V$, respectively. The differences of mean masticatory EMG value between groups were statistically significant at the 0.05 level. 4. The number of posterior occlusal contact point was 20.15 in natural dentition group and 11.92 in removable partial denture wearers. The area of perforated surface was $16.50mm^2$ in natural dentition group and $6.06mm^2$ in removable partial denture wearers. The area of contact surface was $78.93mm^2,\;51.52mm^2$, respectively. 5. The area of contact surface was effective to masticatory performance ratio in natural dentition group and removable partial denture wearers (p<0.05). From these results, it is concluded that in partially edentulous patient, masticatory efficiency can be improved by removable partial denture wearing, and for efficient mastication, tight occlusal contact surface shoud be maintained by maximum support that is provided from mucosa.

  • PDF