• Title/Summary/Keyword: Partial Test

Search Result 1,787, Processing Time 0.029 seconds

Evaluation of Electrical and Leakage Current Characteristics of Polymer Arrester(42kV 10kA Class3) for Railroad Line (전차선로용 폴리머 피뢰기(42kV 10kA Class3)의 전기적 특성 및 누설전류 특성 평가)

  • Kim, Seok-Sou;Choi, Ike-Sun;Park, Choon-Hyun;Cho, I-Gon;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1171-1174
    • /
    • 2004
  • Leakage current of the polymer arrester(42kV, 10kA, Class3) for railroad line applied actually field was observed and electrical characteristics of arrester before and after applied actually field were investigated. During applied actually field, leakage current of arresters were $610{\sim}647{\mu}A$ in AN SAN line and $500{\mu}A$ in YUNG DONG line. After applied actually field, electrical characteristics of arrester, such as insulation test, reference voltage test, leakage current test and partial discharge current test, wasn't variation as before applied actually field.

  • PDF

Performance verification and improvement of the frequency analysis unit for GIS Preventive & Diagnostic Monitoring System (GIS 예방진단시스템 주파수 분석장치 성능개선 및 검증)

  • Kim, Won-Gyu;Kim, Min-Soo;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.485-491
    • /
    • 2015
  • This paper shows the design improvement and test model of FAU (Frequency Analysis Unit) in PDD (Partial Discharge Diagnosis system) for 800kV GIS (Gas Insulated Switchgear). We found some problems during operation of previous FAU, such as the aging of fiber-optic converter that can cause communication error, the malfunction of signal analysis circuit etc. And then we solved those problems by design improvement and verified the performance through type test. To monitor partial discharge, the performance of UHF sensor is important but the performance of frequency analysis unit is also very important. So we solved communication error, the malfunction of signal analysis circuit and then increased the operation reliability of FAU by improving fiber-optic converter and signal analysis circuit. Accredited testing laboratory carried out the performance verification test according to performance test criteria and procedure of reliability test standards, IEC-60225, 61000 and 60068 etc. We confirmed the test results which correspond with the performance test criteria.

A Study on the New Evaluation Method on Insulation of Electronic Components (전자부품의 새로운 절연평가기법 연구)

  • Kil, Gyung-Suk;Snog, Jae-Yong;Moon, Seung-Bo;Cha, Myung-Soo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.503-504
    • /
    • 2006
  • This paper describes a low-level partial discharge(PD) testing that has been accepted as a non-destructive test method on insulation performance of electronic components. A comparative PD analysis combined with the Withstand Voltage Test (WVT) specified in IEC standards is carried out on high frequency switching transformers. The analysis shows that insulation degradation of the transformers under test progresses during the WVT. To avoid insulation degradation of the specimen, PD test has to be carried out at as low voltage as possible. In this study, the PD test on the transformers is performed in ranges from 50% to 70% of the test voltage specified in the WVT by measuring apparent charges below 1 pC. From the experimental results, it is expects that the low-level PD test is applicable for electronic components as a replacement of the WVT.

  • PDF

What are Valuable Positive Signs of Supraspinatus Test for Diagnosis of Torn Rotator Cuff? - Comparison of Pain and Weakness in "Empty Can Test" and "Full Can Test" - (회전근 개 파열의 진단을 위한 극상근 검사에서 유용한 양성 징후는 무엇인가? - "Empty can test"와 full can test"에서 통증과 근력 약화의 비교 -)

  • Shin, Hun-Kyu;Kim, Eu-Gene;Jeong, Hwa-Jae;Kim, Jong-Min;Choi, Jae-Yol;Lee, Yong-Taek
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.1
    • /
    • pp.27-32
    • /
    • 2007
  • Purpose: To investigate the validity of positive signs of supraspinatus test. Materials and Methods: The empty can test and full can test were performed on 200 shoulders which were diagnosed with magnetic resonance imaging or surgical findings as full thickness tear, partial thickness tear and no tear. Presence of pain, weakness, pain or weakness, and both pain and weakness were recorded as positive signs separately. The two tests with positive signs were compared and analyzed. Results: Pain and weakness were severity-dependent, and the empty-can test had a higher incidence of pain. The sensitivities of the two supraspinatus tests in all positive signs were higher when including partial-thickness tears in the tear group; however, their specificities were higher when excluding partial-thickness tears. The sensitivities of an empty-can test in 'pain', 'pain or weakness', 'both pain and weakness' were higher than those of the full-can test, otherwise, the specificity of the full-can test for 'pain' and 'pain or weakness' were higher. Concordance rate between 'pain or weakness' and 'pain' was the highest in all categorization. Conclusion: Both empty can and full can test were valuable for detecting torn rotator cuff.

Study on the Soldering of Off-eutectic Pb-Sn Solders in Partial Melting State

  • Park, Jae-Yong;Ha, Jun-Seok;Kang, Choon-Sik;Shin, Kyu-Sik;Kim, Moon-Il;Jung, Jae-Pil
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.2
    • /
    • pp.63-68
    • /
    • 2000
  • This paper introduces the partial melting process for solder application and characterization of its possibility using off-eutectic Pb-Sn alloy. In order to show that the liquid phase in the semi-liquid state maintains the wettability as the single-phase liquid, the wetting balance test are conducted with varying temperatures and compositions. The results are then compared with the surface tension of liquid, both measured and calculated, to examine the correlation. The results from this investigation indicate that the partial melting can yield satisfactory solder joints as long as the liquid phase acquires sufficient chemical activity. At a condition where the partial melting is effective, a direct correlation between the wettability and the surface tension is found to exist. All alloys are found to show a reasonable wettability in semi-liquid state.

  • PDF

Classification Technique of Kaolin Contaminants Degree for Polymer Insulator using Electromagnetic Wave (방사전자파를 이용한 고분자애자의 오손량 분류기법)

  • Park Jae-Jun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.2
    • /
    • pp.162-168
    • /
    • 2006
  • Recently, diagnosis techniques have been investigated to detect a Partial Discharge associated with a dielectric material defect in a high voltage electrical apparatus, However, the properties of detection technique of Partial Discharge aren't completely understood because the physical process of Partial Discharge. Therefore, this paper analyzes the process on surface discharge of polymer insulator using wavelet transform. Wavelet transform provides a direct quantitative measure of spectral content in the time~frequency domain. As it is important to develop a non-contact method for detecting the kaolin contamination degree, this research analyzes the electromagnetic waves emitted from Partial Discharge using wavelet transform. This result experimentally shows the process of Partial Discharge as a two-dimensional distribution in the time-frequency domain. Feature extraction parameter namely, maximum and average of wavelet coefficients values, wavelet coefficients value at the point of $95\%$ in a histogram and number of maximum wavelet coefficient have used electromagnetic wave signals as input signals in the preprocessing process of neural networks in order to identify kaolin contamination rates. As result, root sum square error was produced by the test with a learning of neural networks obtained 0.00828.

The Fault Detection of an Air-Conditioning System by Using a Residual Input RBF Neural Network (잔차입력 RBF 신경망을 사용한 냉방기 고장검출 알고리즘)

  • Han, Do-Young;Ryoo, Byoung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.8
    • /
    • pp.780-788
    • /
    • 2005
  • Two different types of algorithms were developed and applied to detect the partial faults of a multi-type air conditioning system. Partial faults include the compressor valve leakage, the refrigerant pipe partial blockage, the condenser fouling, and the evaporator fouling. The first algorithm was developed by using mathematical models and parity relations, and the second algorithm was developed by using mathematical models and a RBF neural network. Test results showed that the second algorithm was better than the first algorithm in detecting various partial faults of the system. Therefore, the algorithm developed by using mathematical models and a RBF neural network may be used for the detection of partial faults of an air-conditioning system.

Diagnosis of Medium Voltage Cables for Nuclear Power Plant

  • Ha, Che-Wung;Lee, Do Hwan
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.4
    • /
    • pp.1369-1374
    • /
    • 2014
  • Most accidents of medium-voltage cables installed in nuclear power plants result from the initial defect of internal insulators or the initial failure due to poor construction. However, as the service years of plants increase, the possibility of cable accidents is also rapidly increases. This is primarily caused by electric, mechanical, thermal, and radiation stresses. Recently, much attention is paid to the study of cable diagnoses. To date, partial discharge and Tan${\delta}$ measurements are known as reliable methods to diagnose the aging of medium-voltage cables. High frequency partial discharge measurement techniques have been widely used to diagnose cables in transmission and distribution systems. However, the on-line high frequency partial discharge technique has not been used in the nuclear power plants because of the plant shutdown risk, degraded measurement sensitivity, and application problems. In this paper, the partial discharge measurement with a portable device was tried to evaluate the integrity of the 4.16kV and 13.8kV cable lines. The test results show that the high detection sensitivity can be achieved by the high frequency partial discharge technique. The present technique is highly attractive to diagnose medium voltage cables in nuclear power plants.

Design and Analysis of a Wrist Rotation Module Prototype for Partial Hand Amputees: Effects on Upper Limb Movement (부분 손 절단자를 위한 프로토 타입의 손목 회전 모듈 디자인 제안과 상지 움직임의 영향 분석)

  • Seoyoung Choi;Wonwoo Cho;Keehoon Kim
    • The Journal of Korea Robotics Society
    • /
    • v.18 no.4
    • /
    • pp.367-375
    • /
    • 2023
  • Most partial hand amputees experience limited wrist movement, which hinders the efficient functioning of upper limb, affecting hand-to-use coordination and the usability of the prosthetic hand. This limitation can lead to secondary musculoskeletal issues due to repetitive compensatory movement patterns. However, current partial hand prosthetic lack rotational wrist movement due to challenges in accommodating various hand shapes and limited space. In our study, we proposed a prosthetic hand with a wrist rotation module for partial hand amputees, aiming to reduce compensatory movement. To validate the proposed wrist rotation module, we conducted motion analysis during reach-to-grasp task. Furthermore, during the Jebsen-Taylor hand function test, we evaluated both the effect on upper limb movement and the usability of the prosthetic hand, comparing configurations with and without the wrist rotation module. The results showed that the prosthetic hand equipped with rotational wrist movements reduces compensatory movements and promotes efficient upper limb movement patterns. This finding highlights the value of incorporating a wrist rotation module in prosthetic hands to improve upper limb movement for partial hand amputees.

Treatment of Partial Thickness Burn Wounds with Cultured Epidermal Homografts (동종 배양표피를 이용한 부분층 2도 화상의 치료)

  • Choi, Joong Ho;Ko, Jang Hyu;Seo, Dong Kook;Lee, Jong Wook;Jeon, Saewha;Oh, Suk Joon;Jang, Young Chul
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.587-591
    • /
    • 2006
  • Purpose: Since Rheinwald and Green laid the foundation of epidermal cell culture technology in 1975, many clinicians and scientists have attempted to prove the effectiveness of cultured epidermal autologous(CEA) or homogenetic(CEH) grafts in the wound healing process. In contrast to CEA which cultured from a patient's skin on demand, Cultured Epidermal Homograft(CEH) can be readily available to use on cleaned wounds. In this study, we conducted a controlled clinical trial in order to confirm the effectiveness of CEH in treating partial-thickness 2nd degree burn wounds. Methods: From July 2003 to January 2004 at Hangang Sacred Heart Hospital, we performed a clinical trial in which 35 patients who suffered from 2nd degree burns were enrolled. Wounds were randomly divided into two parts, control and test sites. Test sites were treated with allogeneic keratinocyte sheets ($Kaloderm^{(R)}$, Tegoscience Inc.), a CEH commercialized in Korea. Results: All wounds healed completely without any major complication. The complete healing took $8.3{\pm}2.8$($mean{\pm}S.D.$) days in the test sites as opposed to $11.7{\pm}3.3days$ in the control sites. Conclusion: Based on these results, we concluded that CEH accelerates re-epithelialization of partial thickness burn wounds and CEH can be an safe alternative to skin grafts for 2nd degree burns.