• 제목/요약/키워드: Partial Filter

검색결과 195건 처리시간 0.031초

전력선 통신을 위한 저압변압기에서 발생되는 EMI 노이즈 제거 필터 관한 연구 (Study on EMI filter for Eliminating Noise from Pole Transformer for PLC)

  • 김용성;정중일;김재철;조성민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.533-534
    • /
    • 2007
  • This paper investigates impulsive noise from a pole transformer in low voltage distribution system for power line communication. EMI noise from the pole transformer is indicated from the experiment. The noise has certain characteristics because it is caused by partial discharge. The noise level is above -35dBm without a filter. Therefore, the filter which is made of ferrite is used in order to eliminate the noise. the noise filters should be applied to both the phase line and the neutral line. Otherwise, It is likely to have little overall impact on elimination of noises. the performance of filter is verified with various experiments. In conclusion, the equivalent circuit of power line communication including noise source is described as a lumped circuit.

  • PDF

부분방전신호로부터 노이즈의 제거를 위한 웨이블렛필터링 기법의 적용 (Application of wavelet filtering for Suppression of noise from PD signals)

  • 이강원;박철현;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1845-1848
    • /
    • 2003
  • PD(Partial Discharge) signal have the range from several kHz to several GHz. External noises don't give any interference to discerning PD signals with high frequency bandwidth between several hundreds MHz to several GHz but, in the range between several decades kHz to several MHz, are big obstacles to prevent from discriminating PD signals. Therefore, selecting appropriate filter to decrease the influence of noise is important problem. PD signals have the characteristics both short duration and non-continuous pulse train. For separating PD signals from External noises, some different filtering methods different from conventional ones are needed and wavelet filtering method was convinced to be suitable filtering method in various investigations. This paper has simulated PD signal and various noises and investigated the influences for the performance of wavelet filter by varying the components relative to designing of wavelet filter and constructed suitable one. For the purpose of convincing the performance of wavelet filter, real PDs were produced in needle to plane electrode structure. This small PD signal was mixed with external noises and filtered with wavelet filter. We have obtained apparent PD signals and noises are well suppressed by wavelet filter.

  • PDF

저궤도 인공위성의 센서 및 구동기 통합 고장검출 및 분리 기법 (An Integrated Fault Detection and Isolation Method for Sensors and Actuators of LEO Satellite)

  • 임준규;이준한;박찬국
    • 제어로봇시스템학회논문지
    • /
    • 제17권11호
    • /
    • pp.1117-1124
    • /
    • 2011
  • An integrated fault detection and isolation method is proposed in this paper. The main objective of this paper is development fault detection, isolation and diagnosis algorithm based on the DKF (Decentralized Kalman Filter) and the bank of IMM (Interacting Multiple Model) filters using penalty scalar for both partial and total faults and the outlier detection algorithm for preventing false alarm also included. The proposed FDI (Fault Detection and Isolation) scheme is developed in four phases. In the first phase, the outlier detection filter is designed to prevent false alarm as a pre-filter. In the second phases, two local filters and master filter are designed to detect sensor faults. In the third phases, the proposed FDI scheme checks sensor residual to isolate sensor faults and 11 EKFs actuator fault models are designed to detect wherever actuator faults occur. In the last phases, four filters are designed to identify the fault type which is either the total fault or partial fault. The developed scheme can deal with not only sensor and actuator faults, but also preventing false alarm. An important feature of the proposed FDI scheme can decreases fault isolation time and figure out not only fault detection and isolation but also fault type identification. To verify the proposed FDI algorithm performance, the Simulator is also developed under the Matlab/Simulink environment.

이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구 (A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique)

  • 박재준;전병훈;김진승;전현구;백관현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

전력기기 열화 진단을 위한 부분방전 모의 및 측정 알고리즘 개발연구 (Investigation of Simulation and Measuring Algorithm of Partial Discharge for Diagnosis of Electric Machinery Deterioration)

  • 장형택;곽선근;신판석;김창업;정교범
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.30-38
    • /
    • 2011
  • This paper proposes a new intelligent diagnosis equipment for the partial discharge, which keeps deteriorating the insulating materials inside electric machineries, ultimately leading to electrical breakdown. In order to simulate experimentally the partial discharge inside the electric machinery, the tip-to-plate, the sphere-to-plate, the sphere-to-sphere and the plate-to-plate electrodes are used respectively, of which the gaps are 1[mm], 3[mm] or 5[mm] and the applied voltages are 3[kV], 5[kV] or 7[kV]. Ceramic coupler sensor and FIR digital filter are used to measure the partial discharge and the artificial neural network is used for the deterioration diagnosis of the electric machinery. The microprocessor of PD diagnosis equipment is DSP (TMS320C6713) with FPGA (Cyclone II). The results of the real-time and on-line experiments performed with the developed equipment are also explained.

지능형 IIR 필터 기반 다중 채널 ANC 시스템 (Intelligent IIR Filter based Multiple-Channel ANC Systems)

  • 조현철;여대연;이영진;이권순
    • 제어로봇시스템학회논문지
    • /
    • 제16권12호
    • /
    • pp.1220-1225
    • /
    • 2010
  • This paper proposes a novel active noise control (ANC) approach that uses an IIR filter and neural network techniques to effectively reduce interior noise. We construct a multiple-channel IIR filter module which is a linearly augmented framework with a generic IIR model to generate a primary control signal. A three-layer perceptron neural network is employed for establishing a secondary-path model to represent air channels among noise fields. Since the IIR module and neural network are connected in series, the output of an IIR filter is transferred forward to the neural model to generate a final ANC signal. A gradient descent optimization based learning algorithm is analytically derived for the optimal selection of the ANC parameter vectors. Moreover, re-estimation of partial parameter vectors in the ANC system is proposed for online learning. Lastly, we present the results of a numerical study to test our ANC methodology with realistic interior noise measurement obtained from Korean railway trains.

Improved Kalman filter with unknown inputs based on data fusion of partial acceleration and displacement measurements

  • Liu, Lijun;Zhu, Jiajia;Su, Ying;Lei, Ying
    • Smart Structures and Systems
    • /
    • 제17권6호
    • /
    • pp.903-915
    • /
    • 2016
  • The classical Kalman filter (KF) provides a practical and efficient state estimation approach for structural identification and vibration control. However, the classical KF approach is applicable only when external inputs are assumed known. Over the years, some approaches based on Kalman filter with unknown inputs (KF-UI) have been presented. However, these approaches based solely on acceleration measurements are inherently unstable which leads poor tracking and so-called drifts in the estimated unknown inputs and structural displacement in the presence of measurement noises. Either on-line regularization schemes or post signal processing is required to treat the drifts in the identification results, which prohibits the real-time identification of joint structural state and unknown inputs. In this paper, it is aimed to extend the classical KF approach to circumvent the above limitation for real time joint estimation of structural states and the unknown inputs. Based on the scheme of the classical KF, analytical recursive solutions of an improved Kalman filter with unknown excitations (KF-UI) are derived and presented. Moreover, data fusion of partially measured displacement and acceleration responses is used to prevent in real time the so-called drifts in the estimated structural state vector and unknown external inputs. The effectiveness and performance of the proposed approach are demonstrated by some numerical examples.

RF front-end Module for On-Line UHF Partial-discharge Monitoring System

  • Lee June Young;Kim Bok Ki
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2004년도 학술대회지
    • /
    • pp.776-779
    • /
    • 2004
  • A RF front-end module is designed for GIS(Gas Insulated Substation) which is employed for effective and efficient very high voltage transmission. Major advantage of the unit is improved PO detection sensitivity through minimizing the effect of surrounding interference signals, which is achieved by controlling the gain and the selection of the frequency band, for the precise detection of any UHF PO (Partial Discharge) disturbance occurred in the GIS due to some unwanted problems. For the development of the module, various switches for providing selected signal paths, wideband LNA, 3 BPF for selecting detection frequency band, and video detector are designed, fabricated and measured on 1 mm FR4 substrate with various RF components. The detection sensitivity of the unit was <-60 dBm that is sufficient to detect UHF PO signals as low as 1 pC. It is believed that the value is enough to detect the signal occurred in GIS.

  • PDF

측정치 시간지연과 선체의 유연성을 고려한 전달정렬 기법 (A Transfer Alignment Considering Measurement Time-Delay and Ship Body Flexure)

  • 임유철;유준
    • 한국군사과학기술학회지
    • /
    • 제4권1호
    • /
    • pp.225-233
    • /
    • 2001
  • This paper deals with the transfer alignment problem of SDINS(StrapDown Inertial Navigation System) subjected to roll and pitch motions of the ship. Specifically, to reduce alignment errors induced by measurement time-delay and ship body flexure, an error compensation method is suggested based on delay state augmentation and DCM(Direction Cosine Matrix) partial matching. A linearized error model for the velocity and attitude matching transfer alignment system is first derived by linearizing the nonlinear measurement equation with respect to its time delay and augmenting the delay state into the conventional linear state equations. And then DCM partial matching is properly combined to reduce effects of a ship's Y axis flexure. The simulation results show that the suggested method is effective enough resulting in considerably less azimuth alignment errors.

  • PDF

고압전동기 고정자 권선에서 부분방전 펄스의 전송 (Propagation of Partial Discharge Pulse in High Voltage Motor Stator Windings)

  • 김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권11호
    • /
    • pp.512-515
    • /
    • 2003
  • This paper is to investigate how partial discharge pulse signal can flow in 6.6㎸ motor stator windings. Pulse propagation is experimentally analyzed in stator windings using a variety of frequency-domain techniques. The experiments were performed on two stator windings in the laboratory. Spectrum analyzer(9KHz to 3㎓) with tracking generator(100kHz to 3㎓) was used. Sweep time of the tracking generator was looms. The frequency spectrum of the response signal was detected by active FET probe(1㎓). The active FET probe has a flat amplitude response up to 1㎓ without high frequency attenuation. The stator winding acts as a low-pass filter below 600KHz, the high-frequency components being highly declined. The resonance peaks show about 1.1MHz and 2MHz in low frequency of No. 1 and No. 2 stator windings, respectively. This low-frequency range indicates that attenuation is low. The peaks of partial discharge magnitude show about 900MHz, 1.6MHz in No. 1 stator winding and about 800KHz, 1.4MHz in No. 2 stator winding.