• Title/Summary/Keyword: Partial Filter

Search Result 195, Processing Time 0.023 seconds

A transfer alignment algorithm using velocity and quaternion partial matching methods (속도및 쿼터니언 부분 정합방식에 의한 전달정렬 알고리즘)

  • Song, Ki-Won;Jeon, Chang-Bae;Lyou, Joon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.3 no.3
    • /
    • pp.238-243
    • /
    • 1997
  • A new transfer alignment algorithm using the velocity and the quaternion partial matching methods is proposed to reduce the effect of a ship's Y-axis flexure on the performance of azimuth error estimation of Kalman filter. The simulation results show that it can significantly reduce the effect of Y-axis flexure on error estimation by the transfer alignment algorithm. As its results, azimuth transfer alignment error is reached up to 3 mrad under proper roll and pitch attitude motion of the ship.

  • PDF

A New Hop-Timing Estimator with a Normalized Envelop Detector and an Early-Late Filter (정규화 포락선 검파기와 얼리-레이트 필터를 적용한 새로운 홉 타이밍 예측기)

  • Lee, Ju-Hyung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.4C
    • /
    • pp.355-361
    • /
    • 2007
  • In this paper, the hop-timing estimator, which NED and ELF are adopted to, has been proposed. The estimation performance of the proposed scheme and the conventional scheme is compared through computer simulations. The simulation results show that the new system has less hop-timing error than the conventional system in partial band noise jamming channel. The lover Eb/Nj and ratio of jamming bandwidth(rho) we, the bigger performance enhancement of the proposed system is.

Studies on Reforming Gas Assisted Regeneration of Multi-channel Catalyzed DPF (합성가스(Reforming gas)를 이용한 멀티채널 CDPF의 재생 특성 연구)

  • Choi, Kwang-Chun;Chung, Jin-Hwa;Song, Soon-Ho;Chun, Kwang-Min
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.3
    • /
    • pp.138-145
    • /
    • 2011
  • Diesel particulate filter (DPF) systems are being used to reduce the particulate matter emission of diesel vehicles. The DPF should be regenerated after certain driving hours or distance to eliminate soot in the filter. The most widely used method is active regeneration with oxygen at $550{\sim}650^{\circ}C$. Syngas (synthetic gas) can be used to lower the regeneration temperature of Catalyzed DPF (CDPF). The syngas is formed by fuel reforming process of CPOx (Catalytic Partial Oxidation) at specific engine condition (1500rpm, 2bar) using 1wt.% $Rh/CeO_2-ZrO_2$ catalyst. The oxidation characteristics of PM with syngas supplied to filter were studied using partial flow system that can control temperature and flow rate independently. The filter is coated with washcoat loading of $25g/ft^3$ $Pt/Al_2O_3-CeO_2$, and multi-channel CDPF (MC-CDPF) was used. The filter regeneration experiments were performed to investigate the effect of syngas exothermic reaction on soot oxidation in the filter. For this purpose, before oxidation experiment, PM was collected about 8g/L to the filter at engine condition of 1500rpm, bmep 8bar and flow temperature of $200^{\circ}C$ Various conditions of temperature and concentration of syngas were used for the tests. Regeneration of filter started at 2% $H_2$ and CO concentration respectively and inlet temperature of $260^{\circ}C$. Filter Regeneration occurs more actively as the syngas concentration becomes higher.

Detection of the Ultrasonic Signals due to Partial Discharges in a 154kV Transformer

  • Kweon, Dong-Jin;Chin, Sang-Bum;Kwak, Hee-Ro
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.297-303
    • /
    • 2002
  • We have developed an on-line ultrasonic detector to monitor partial discharge in an operating transformer. The ultrasonic sensor has 150[KHz] resonance frequency and contains a pre-amplifier with 60[㏈] gain. The on-line ultrasonic detector has 50~300[KHz] frequency band-pass filter to remove electrical and mechanical noises from the transformer. This detector has an ultrasonic signal discrimination algorithm which discriminates ultrasonic signals due to partial discharge in a transformer. A moving average method of ultrasonic signal number was employed to effectively monitor the increasing trend of the partial discharge. This paper describes an experience of partial discharge detection in a 154[㎸] operating transformer using an ultrasonic detector. With regards to gas analysis in oil, C2H2 gas was produced with a warning level in this transformer We detected ultrasonic signals on the transformer steel wall, and estimated the position of partial discharge. With further inspection, we found carbonized marks due to partial discharge on the supporting bolt which fastens the windings.

PM Reduction Characteristics of Partial Metal DPF with Screen Mesh Filter Structure (스크린 필터 구조 Partial Metal DPF의 PM 저감 특성)

  • Kim, Chunghui;Kim, Hyunchul;Lee, Geesoo;Choi, Jeonghwang;Chon, Munsoo;Shin, Suk Shin;Suh, Hyun Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.3
    • /
    • pp.82-87
    • /
    • 2013
  • In this work, the 1L grade integrated metal DOC/DPF filter that can install in engine manifold position was developed to investigate the effect of platinum-coating amount of filter on the improvement of filter activation temperature and reduction of particulate matter (PM). This filter was installed in 2.9L CI engine which meets the EURO-4 emission regulation. Tests for PM reduction efficiency of filter were conducted under ND-13 mode with full-load test condition. It was revealed that the time to reach the activation temperature of metal filter ($280^{\circ}C$) was shorter as the amount of platinum-coating increased. This short activation time can be helpful for the reduction of CO and HC emissions during cold start condition. At the same time, PM reduced as the coating amount increased. The reduction percentage of $DOC_{40}$, $DOC_{20}$, and $DOC_0$ were 96.7% (2.34 mg/kW'h), 95.1% (3.47 mg/kW'h), and 94.5% (3.69 mg/kW'h) compared to previous result (71.4 mg/kW'h), respectively.

Detection and parametric identification of structural nonlinear restoring forces from partial measurements of structural responses

  • Lei, Ying;Hua, Wei;Luo, Sujuan;He, Mingyu
    • Structural Engineering and Mechanics
    • /
    • v.54 no.2
    • /
    • pp.291-304
    • /
    • 2015
  • Compared with the identification of linear structures, it is more challenging to conduct identification of nonlinear structure systems, especially when the locations of structural nonlinearities are not clear in structural systems. Moreover, it is highly desirable to develop methods of parametric identification using partial measurements of structural responses for practical application. To cope with these issues, an identification method is proposed in this paper for the detection and parametric identification of structural nonlinear restoring forces using only partial measurements of structural responses. First, an equivalent linear structural system is proposed for a nonlinear structure and the locations of structural nonlinearities are detected. Then, the parameters of structural nonlinear restoring forces at the locations of identified structural nonlinearities together with the linear part structural parameters are identified by the extended Kalman filter. The proposed method simplifies the identification of nonlinear structures. Numerical examples of the identification of two nonlinear multi-story shear frames and a planar nonlinear truss with different nonlinear models and locations are used to validate the proposed method.

SoC Implementation of Deblocking Filter for Block-based Compressed Images and Videos (블록 기반 압축 이미지 및 비디오를 위한 디블로킹 필터의 SoC 구현)

  • Seo, Gwang-Seok;Lee, Joo-Heung
    • Journal of IKEEE
    • /
    • v.23 no.3
    • /
    • pp.925-933
    • /
    • 2019
  • In this paper, we implement ZYNQ SoC-based post-processing system that utilizes partial reconfiguration to remove blocking artifacts generated by compression algorithm. Hardware implementation of the deblocking filter in a Field Programmable Gate Array (FPGA) provides high computational capability and can be partially reconfigured to process 1080p images in real time. Partially reconfigurable areas in FPGA can be utilized to use hardware more efficiently in highly resource-constrained embedded systems. Experimental results of the proposed system show improvement of visual quality both objectively and subjectively with 0.6dB higher PSNR after deblocking filtering process. The measured power consumption of the deblocking filter during run-time is 68.33mW.

A Design of Low Power Digital Matched Filter using Rounding for IMT-2000 Communication Systems (IMT-2000 통신시스템에서의 라운딩을 이용한 저전력 디지털 정합필터의 설계)

  • Park, Ki-Hyun;Ha, Jin-Suk;Nam, Ki-Hun;Cha, Jae-Sang;Lee, Kwang-Youb
    • Journal of IKEEE
    • /
    • v.8 no.1 s.14
    • /
    • pp.145-151
    • /
    • 2004
  • For wide-band spread spectrum communication systems such as IMT-2000, a digital matched filter is a key device for rapid spreading code synchronization. Although a digital matched filter can be implemented easily, large power consumption at the higher chip rate and large summation delay of longer chip length are the bottleneck of practical use. In this paper, we propose a optimized partial correlation digital matched filter structure which can be constructed of the so-called generalized hierarchical Golay sequence. a partial correlation structure can reduce the number of correlators, but enlarge the size of flip-flops. In this paper, The proposed approach focuses on efficient circuit size, power dissipation, maintaining the operating throughput. A proposed digital matched filter reduce the size of flip-flops by rounding method. and it reduces about 45 percentages of power dissipation and chip area as compared with digital matched filter which is not rounded. rounding. The proposed architecture was verified by using Xilinx FPGA.

  • PDF

Infiltration characteristic of modified slurry and support efficiency of filter cake in silty sand strata

  • Sai Zhang;Jianwen Ding;Ning Jiao;Shuai Sun;Jinyu Liu
    • Geomechanics and Engineering
    • /
    • v.34 no.2
    • /
    • pp.125-138
    • /
    • 2023
  • To improve the understanding of infiltration characteristic of modified slurry and the support efficiency of filter cake in silty sand strata, the slurry infiltration (SI) and filter cake formation (FCF) were investigated in a laboratory apparatus. The water discharge and the excess pore pressure at different depths of silty sand strata were measured during SI. The relationship between permeability coefficient/thickness ratio of filter cake (kc/ΔL) and effective slurry pressure conversion rate of filter cake (η) were analyzed. Moreover, the SI and FCF process as well as the modification mechanism of CMC (carboxymethyl cellulose) were clarified. The experimental results indicate the formation of only external filter cake in the silty sand strata. The slurry particles obtain thicker water membrane after being modified by CMC, which blocks partial water path in filter cake and decreases the water discharge significantly. The silty sand excavated from tunnel face also contributes to the water discharge reduction. The kc of the external filter cake ranges from 3.83×10-8 cm/s to 7.44×10-8 cm/s. The η of the external filter cake is over 96%, which decreases with increasing kc/ΔL. A silty sand content within 10% is suggested during construction to ensure the uniformity of the filter cake.