• Title/Summary/Keyword: Part-load

Search Result 2,121, Processing Time 0.026 seconds

Signal Processing of Capacitive Load and Gap Measurement with High Precision Using Surface Acoustic Wave Device (표면 탄성파 장치를 이용한 용량성 부하의 신호처리 및 이를 이용한 초정밀 간극 측정)

  • Kim, Jae-Geun;Lee, Taek-Joo;Lim, Soo-Cheol;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.376-380
    • /
    • 2009
  • Surface acoustic wave (SAW) device is widely used as a bandpass filter, a chemical or physical sensor, and an actuator. In this paper, we propose the capacitive gap measurement system with high precision through the signal processing using SAW device. The research process is mainly composed of theoretical part and experimental part. In theoretical part, equivalent circuit model was used to simulate the SAW response by the change of capacitance. In experimental part, commercialized capacitor was used to see the SAW response by the change of load capacitance. After that, gap adjustment system was made physically and the SAW response by the change of gap which caused the capacitance change was measured. And resolution and stroke was decided comparing the signal change and basic measurement noise level.

  • PDF

Strength and Fatigue Analysis of Universal Joint (유니버설조인트의 강도 및 피로 해석)

  • Cho, Jae-Ung;Han, Moon-Sik
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.4
    • /
    • pp.427-433
    • /
    • 2011
  • Chassis part in automotive body is affected by fatigue load at driving on the ground. Universal joint on this part is influenced extremely by the fatigue load. Fatigue life, damage and natural frequency are analyzed at universal joint under nonuniform fatigue load. The york part at universal joint is shown with the maximum equivalent stress and displacement of 60.755 MPa and 0.21086 mm as strength analysis. The possible life in use in case of 'SAE bracket' is the shortest among the fatigue loading lives of 'SAE bracket', 'SAE transmission' and 'Sine Wave'. The damage at loading life of 'SAE transmission' is the least among 3 types. The frequency of damage in case of 'Sine Wave' is 0.7 with the least among 3 fatigue loading life types but this case brings the most possible damage as 80% at the average stress of 0. Natural vibration at this model is analyzed with the orders of 1'st to 5'th and maximum frequency is shown as 701.73 Hz at 5'th order. As the result of this study is applied by the universal joint on chassis part, the prevention on fatigue damage in automotive body and its durability are predicted.

A Study on the Vibration Characteristics of Collecting Plate in the Electrostatic Precipitator Using Holograpy (홀로그래피를 이용한 정전집진기 집진판의 진동 특성 연구)

  • 나종문;이기백;양장식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.56-66
    • /
    • 1996
  • In this study, the characteristics of generation and propagarion of transient wave induced in the assembly of four collecting plate upon the propagation of waves are analyzed. Also double exposure holographic inteferometry using ruby pulse laser is built in order to investigate the propagation of transient waves generated by impact load. When impact load was applied at edge of connecting band, the vibration of collecting plates was generated from the contact points between collecting plate and band which connects four collecting plates. Waves generated from the lower part and those reflected from the upper part were mixed as time went on and then formed very complex shapes. Also, when impact load was aplied at center of collecting plate, the waves propagating across the convexo-concave plane were reflected partly at curved section. Therefore the vibration amplitude was decreased as the transiet waves were propagated through the convexo-concave plane.

  • PDF

치과용 생체세라믹스의 강화

  • Gong, Yeong-Min
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2010.05a
    • /
    • pp.5.2-5.2
    • /
    • 2010
  • 인체 경조직인 뼈와 치아는 콜라겐 단백질과 인산칼슘 무기질 성분으로 구성된 최적의 복합체라 볼 수 있다. 이러한 인산칼슘 무기질 성분은 결정학적, 화학적으로 hydroxyapatite (HA, Ca10(PO4)6(OH)2)와 거의 유사하여 높은 생체활성과 골전도성을 보이는 것으로 알려져 있다. 또한, hydroxyapatite의 고온 분해 산물로 볼 수 있는 tricalcuim phosphate(TCP, Ca3(PO4)2)는 체내에 이식시 체액에 용해되어 신생골을 유도하는 생체흡수성 세라믹스로 알려져있다. 이러한 HA와 TCP는 우수한 생체친화성에도 불구하고 기계적 특성이 낮아, non-load bearing 부위에 적용이 되어 다공질의 골수복재 용도로 활용되거나, load-bearing부위의 적용을 위한 금속 implant 등의 생체친화성 보완을 위한 표면 코팅재로 사용되고 있는 실정이다. 본 발표에서는 생체특성이 매우 우수한 인산칼슘 생체세라믹스의 load-bearing part 적용을 위하여 강도 및 파괴인성의 기계적 특성을 증진시킨 사례를 살펴보고, non-load bearing part에 실제 사용되는 인산칼슘 생체세라믹스의 다공질(porous) 골수복재(bone graft)의 역학 특성 증진을 위한 아이디어와 함께, 역학 특성이 매우 뛰어난 지르코니아 생체세라믹스의 강화-소결법에 대하여 소개하고자 한다.

  • PDF

System Development for the estimation of Pollutant Loads on Reservoir

  • Shim, Soon-Bo;Lee, Yo-Sang;Koh, Deuk-Koo
    • Korean Journal of Hydrosciences
    • /
    • v.10
    • /
    • pp.35-46
    • /
    • 1999
  • An integrated system of GIS and water quality model was suggested including the pollutant loads from the watershed. The developed system consits of two parts. First part is the information on landuse and several surface factors concerning the overland flow processes of water and pollutants. Second part is the modeling modules which include storm event pollutant load model(SEPLM), non-storm event pollutant load model(NSPLM), and river water quality simulation model(RWQSM). Models can calculate the pollutant load from the study area. The databases and models are linked through the interface modules resided in the overall system, which incorporate the graphical display modules and the operating scheme for the optimal use of the system. The developed system was applied to the Chungju multi-purpose reservoir to estimate the pollutant load during the four selected rainfall events between 1991 and 1993, based upon monthly basis and seasonal basis in drought flow, low flow, normal flow and wet flow.

  • PDF

Deformation Mechanism of the Roller Hemming Process with the Finite Element Analysis (유한요소해석을 이용한 롤러헤밍 공정의 변형기구 분석)

  • Rho, J.D.;Kwak, J.H.;Kim, S.H.;Ju, Y.H.;Kim, J.H.;Shin, H.S.
    • Transactions of Materials Processing
    • /
    • v.25 no.5
    • /
    • pp.325-331
    • /
    • 2016
  • In this paper, a three-dimensional part model is constructed for the finite element analysis of hemming models where hemming defects frequently occur. The roller path is modeled as the boundary condition with the one-dimensional beam element and the revolute joint model. With the constructed part model and the roller movement, a finite element analysis has been pursued in order to identify the hemming load and hemming defects such as wrinkling in the flange region. The analysis result shows that the maximum hemming load occurs in the intake situation while oscillatory behavior of the load is found especially when hemming the curved model because of wrinkle generation. This paper compares the amplitude and the period of wrinkle between the analysis result and the experiment, which shows good agreement with each other.

Dynamic Analysis of Single-Effect/Double-Lift Libr-Water Absorption System using Low-Temperature Hot Water (저온수를 이용하는 일중효용/이단승온 리튬브로마이드-물 흡수식 시스템의 동적 해석)

  • Kim, Byong-Joo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.695-702
    • /
    • 2009
  • Dynamic behavior of Libr-water absorption system using low-temperature hot water was investigated numerically. Thermal-hydraulic model of single-effect/double-lift 100 RT chiller was developed by applying transient conservation equations of total mass, Libr mass, energy and momentum to each component. Transient variations of system properties and transport variables were analysed during start-up operation. Numerical analysis were performed to quantify the effects of bulk concentration and part-load operation on the system performance in terms of cooling capacity, coefficient of performance, and time constant of system. For an absorption chiller considered in the present study, optimum bulk concentration was found to exist, which resulted in the minimum time constant with stable cooling capacity. COP and time constant increased as the load decreased down to 40%, below which the time constant increased abruptly and COP decreased as the load decreased further.

Stress Analysis Acting on Electric Pole using Strain Gauge from Full Scale Pull-Out Test (실물인장실험시 변형률계를 이용한 전주에 작용하는 응력분석)

  • Ahn, Tae-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.49-55
    • /
    • 2010
  • Many electric poles in the softground have been collapsed due to external load. In this study, 10 types of tests were performed with variation of location, numbers and depths of anchor blocks as well as depth of poles to find stresses acting on concrete electric poles. The stresses of concrete poles are relaxed at 600~700[kg] of tensile load, and stresses are concentrated at top of pole, and spread to lower part of pole. In the concrete pole collapse test, tensile load at failure was approximately 1,400[kg], which is twice of design load. As passive zone in the soil increases, the stresses acting on concrete pole are concentrated at lower part of pole based on moment arm earth pressure distribution.

Investigation on the failure type of tower segments under equivalent static wind loads

  • Li, Yue;Xie, Qiang;Yang, Zheng
    • Wind and Structures
    • /
    • v.34 no.2
    • /
    • pp.161-171
    • /
    • 2022
  • This paper presents a failure type assessment curve method to judge the failure type of transmission tower segments. This novel method considers the equivalent static wind load characteristics and the transmission tower members' load-bearing capacities based on numerical simulations. This method can help judge the failure types according to the relative positions between the actual state points and the assessment curves of transmission tower segments. If the extended line of the actual state point intersects with the horizontal part's assessment curve, the segment would lose load-bearing capacity due to the diagonal members' failure. Another scenario occurs when the intersection point is in the oblique part, indicating that the broken main members have caused the tower segment to fail. The proposed method is verified by practical engineering case studies and static tests on the scaled tower segments.

Energy efficiency improvements in part load for a marine auxiliary diesel engine (선박발전기용 디젤엔진의 부분부하에서 에너지 효율 개선에 관한연구)

  • Jung, Kyun-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.7
    • /
    • pp.877-882
    • /
    • 2014
  • The reduction of CO2 emission has been discussed in the Marine Environment Protection committee in the International Maritime Organization as the biggest causes of GHG for the purpose of indexing CO2 amounts released into the atmosphere from ships. Accordingly, various methods including the change in the hull design to improve energy efficiency, the coating development to reduce friction resistances, the additives development for improving thermal efficiency in an engine, the low-speed operation to reduce fuel consumptions, and etc. have been applied. The main engine of a ship is an electronic engine for improving the efficiency of the whole load area. However, marine generator engines still use mechanical drive engines in intake, exhaust, and fuel injection valve drive cams. In addition, most of marine generator engines in ships apply a part-load operation of less then 80% due to an overload protection system. Therefore, marine auxiliary diesel engine set at 100% load is necessary to readjust in order to efficient operation because of part-load operation. The objective of this study is to report the results of the part-load fuel consumption improvement by injection timing readjust to identifying the operational characteristics of a marine generator engine currently operated in a ship.