A Dosimetric Evaluation of Large Pendulous Breast Irradiation in Prone Position (Large Pendulous Breast 환자의 방사선 치료에 있어서 엎드린 자세의 유용성 평가)

  • Hong, Chae-Seon;Ju, Sang-Gyu;Park, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.37-43
    • /
    • 2008
  • Purpose: To evaluate dosimetry results of three different techniques for whole breast irradiation after conservative surgery of large pendulous breast patient. Materials and Methods: Planning computed tomography (CT) scans for three techniques were performed on a GE Hi-speed advantage CT scanner in the supine (SP), supine with breast supporting Device (SD) and prone position on a custom prone mattress (PP). Computed tomography images were acquired at 5 mm thickness. The clinical target volumes (CTV), ipsilateral lung and heart were delineated to evaluate the dose statistic, and all techniques were planned with the tangential photon beams (Pinnacle$^3$, Philips Medical System, USA). The prescribed dose was 50 Gy delivered in 25 fractions. To evaluate the dose coverage for CTV, we analysed percent volume of CTV receiving minimum of 95%, 100%, 105%, and 110% of prescription dose ($V_{95}$, $V_{100}$, $V_{105}$, and $V_{110}$) and minimal dose covering 95% ($D_{95}$) of CTV. The dosimetric comparison for heart and ipsilateral lung was analysed using the minimal dose covering 5% of each organs ($D_5$) and the volume that received >18 Gy for the heart and >20 Gy for the ipsilateral lung. Results: Target volume coverage ($V_{95}$ and $V_{100}$) was not significantly different for all technique. The V105 was lower for PP (1.2% vs. 4.4% for SP, 11.1% for SD). Minimal dose covering 95% ($D_{95}$) of target was 47.5 Gy, 47.7 Gy and 48 Gy for SP, SD and PP. The volume of ipsilateral lung received >20 Gy was 21.7%, 11.6% and 4.9% for SP, SD and PP. The volume of heart received >18 Gy was 17.0%, 16.1% and 9.8% for SP, SD and PP. Conclusion: Prone positioning of patient for large pendulous breast irradiation enables improving dose uniformity with minimal heart and lung doses.

  • PDF

Evaluation of useful treatment which uses dual-energy when curing lung-cancer patient with stereotactic body radiation therapy (폐암 환자의 정위적방사선 치료 시 이중 에너지를 이용한 치료 방법의 유용성 평가)

  • Jang, Hyeong Jun;Lee, Yeong Gyu;Kim, Yeong Jae;Park, Yeong Gyu
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.87-99
    • /
    • 2016
  • Purpose : This study will evaluate the clinical utility by applying clinical schematic that uses monoenergy or dual energy as according to the location of tumors to the stereotactic radiotherapy to compare the change in actual dose given to the real tumor and the dose that locates adjacent to the tumor. Materials and Methods : CT images from a total of 10 patients were obtained and the clinical planning were planned based on the volumetric modulated arc therapy on monoenergy and dual energy. To analyze the change factor in the tumor, Comformity Index(CI) and Homogeneity Index(HI) and maximum dose quantity were each calculated and comparing the dose distribution on normal tissues, $V_{10}$ and $V_5$, first ~ fourth ribs closest to the tumor ($1^{st}{\sim}4^{th}$ Rib), Spinal Cord, Esophagus and Trachea were selected. Also, in order to confirm the accuracy on which the planned dose distribution is really measured, the 2-dimensional ion chamber array was used to measure the dose distribution. Results : As of the tumor factor, CI and HI showed a number close to 1 when the two energies were used. As of the maximum dose, the front chest wall showed 2% and the dorsal tumor showed equivalent value. As of normal tissue, the front chest wall tumors were reduced by 4%, 5% when both energies were used in the adjacent rib and as of trachea, reduced by 11%, 17%. As of the dose in the lung, as of $V_{10}$, it reduced by 1.5%, $V_5$ by 1%. As of the rear chest wall, when both energies were used, the ribs adjacent to the tumors showed 6%, 1%, 4%, 12% reduction, and in the lung dose distribution, $V_{10}$ reduced by 3%, and $V_5$ reduced by 3.1%. The dose measurement in all energies were in accordance to the results of Gamma Index 3mm/3%. Conclusion : It is considered that rather than using monoenergy, utilizing double energy in the clinical setting can be more effectively applied to the superficial tumors.

  • PDF

The feasibility evaluation of Respiratory Gated radiation therapy simulation according to the Respiratory Training with lung cancer (폐암 환자의 호흡훈련에 의한 호흡동조 방사선치료계획의 유용성 평가)

  • Hong, mi ran;Kim, cheol jong;Park, soo yeon;Choi, jae won;Pyo, hong ryeol
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.2
    • /
    • pp.149-159
    • /
    • 2016
  • Purpose : To evaluate the usefulness of the breathing exercise,we analyzed the change in the RPM signal and the diaphragm imagebefore 4D respiratory gated radiation therapy planning of lung cancer patients. Materials and Methods : The breathing training was enforced on 11 patients getting the 4D respiratory gated radiation therapy from April, 2016 until August. At the same time, RPM signal and diaphragm image was obtained respiration training total three steps in step 1 signal acquisition of free-breathing state, 2 steps respiratory signal acquisition through the guide of the respiratory signal, 3 steps, won the regular respiration signal to the description and repeat training. And then, acquired the minimum value, maximum value, average value, and a standard deviation of the inspiration and expiration in RPM signal and diaphragm image in each steps. Were normalized by the value of the step 1, to convert the 2,3 steps to the other distribution ratio (%), by evaluating the change in the interior of the respiratory motion of the patient, it was evaluated breathing exercise usefulness of each patient. Results : The mean value and the standard deviation of each step were obtained with the procedure 1 of the RPM signal and the diaphragm amplitude as a 100% reference. In the RPM signal, the amplitudes and standard deviations of four patients (36.4%, eleven) decreased by 18.1%, 27.6% on average in 3 steps, and 2 patients (18.2%, 11 people) had standard deviation, It decreased by an average of 36.5%. Meanwhile, the other four patients (36.4%, eleven) decreased by an average of only amplitude 13.1%. In Step 3, the amplitude of the diaphragm image decreased by 30% on average of 9 patients (81.8%, 11 people), and the average of 2 patients (18.2%, 11 people) increased by 7.3%. However, the amplitudes of RPM signals and diaphragm image in 3steps were reduced by 52.6% and 42.1% on average from all patients, respectively, compared to the 2 steps. Relationship between RPM signal and diaphragm image amplitude difference was consistent with patterns of movement 1, 2 and 3steps, respectively, except for No. 2 No. 10 patients. Conclusion : It is possible to induce an optimized respiratory cycle when respiratory training is done. By conducting respiratory training before treatment, it was possible to expect the effect of predicting the movement of the lung which could control the patient's respiration. Ultimately, it can be said that breathing exercises are useful because it is possible to minimize the systematic error of radiotherapy, expect more accurate treatment. In this study, it is limited to research analyzed based on data on respiratory training before treatment, and it will be necessary to verify with the actual CT plan and the data acquired during treatment in the future.

  • PDF

Analysis of characteristics affecting the score-groups by supervisor and subordinate rating (하향평가와 상향평가 결과에 영향을 미치는 특성 분석)

  • Shin Ki Soo;Cho Woo Hyun;Park Young Yo;Jung Sang Huyk;Lee Hye Jean
    • Health Policy and Management
    • /
    • v.15 no.1
    • /
    • pp.97-117
    • /
    • 2005
  • This study was designed to compare the differences m results of supervisor and subordinate rating. Data was collected from personnel evaluation and subordinate rating results for middle managers(n=68) in hospital from 3rd January to 20th March in 2004. Supervisor rating consisted of performance, ability and attitude evaluation. Subordinate rating consisted of leadership, ability and attitude evaluation. Collected data included sociodemographic characteristics, work department, work level, years of work, years at present level and whether working in a patient serving department. The difference of standardized supervisor and subordinate rating score was used to define groups as 'higher in supervisor rating group'. Groups were defined in total score, ability score and attitude score. Main results were as follows: 1. In total score, sectional chiefs were apt to be 'higher in subordinate rating group' while chief clerks were apt to be 'similar group' or 'higher in supervisor rating group'. Staffs in patient serving department were likely to be 'higher in supervisor rating group' and staffs in non-patient serving department were likely to be 'higher in subordinate rating group'. All these results were statistically significant. 2. In ability score, there were no statistically significant differences in age, sex, years of education, work department, work level, years of work and whether working in a patient serving department among 'higher in supervisor rating group', 'similar group' and 'higher in subordinate rating group'. 3. In attitude score, staffs in the department of medical affairs and the department of administration were apt to be 'higher in subordinate rating group'. Staffs in the department of nursing were apt to be 'higher in supervisor rating group'. Staffs in a patient serving department were likely to be 'higher in supervisor rating group' and staffs in a non-patient serving department were likely to be 'higher in subordinate rating group'. All these results were statistically significant. 4. Logistic analysis about total score showed that sectional chiefs had higher Odds Ratio(OR) to be in 'higher in subordinate rating group'. Staffs in a non-patient serving department had higher OR to be in 'higher in subordinate rating group'. Both these results were statistically significant. 5. Logistic analysis about ability score showed that sectional chiefs had higher OR to be in 'higher in subordinate rating group'. Staffs in a non-patient serving department had higher OR to be in 'higher in subordinate rating group'. These results were not statistically significant. 6. Logistic analysis about total score showed that sectional chiefs had higher OR to be in 'higher in subordinate rating group', but the difference was not statistically significant. Staffs in a non-patient serving department had significantly higher OR to be in 'higher in subordinate rating group'. In conclusion, there is no clear superiority between supervisor and subordinate rating in personnel evaluation. It would be better to use a mixed model. It's also suggested to use an intervening rate of application or scores considering work levels and work department in personnel evaluation. These results would be helpful for hospitals planning a supervisor and subordinate rating system for personnel evaluation.

Review on Usefulness of EPID (Electronic Portal Imaging Device) (EPID (Electronic Portal Imaging Device)의 유용성에 관한 고찰)

  • Lee, Choong Won;Park, Do Keun;Choi, A Hyun;Ahn, Jong Ho;Song, Ki Weon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Purpose: Replacing the film which used to be used for checking the set-up of the patient and dosimetry during radiation therapy, more and more EPID equipped devices are in use at present. Accordingly, this article tried to evaluated the accuracy of the position check-up and the usefulness of dosimetry during the use of an electronic portal imaging device. Materials and Methods: On 50 materials acquired with the search of Korea Society Radiotherapeutic Technology, The Korean Society for Radiation Oncology, and Pubmed using "EPID", "Portal dosimetry", "Portal image", "Dose verification", "Quality control", "Cine mode", "Quality - assurance", and "In vivo dosimetry" as indexes, the usefulness of EPID was analyzed by classifying them as history of EPID and dosimetry, set-up verification and characteristics of EPID. Results: EPID is developed from the first generation of Liquid-filled ionization chamber, through the second generation of Camera-based fluoroscopy, and to the third generation of Amorphous-silicon EPID imaging modes can be divided into EPID mode, Cine mode and Integrated mode. When evaluating absolute dose accuracy of films and EPID, it was found that EPID showed within 1% and EDR2 film showed within 3% errors. It was confirmed that EPID is better in error measurement accuracy than film. When gamma analyzing the dose distribution of the base exposure plane which was calculated from therapy planning system, and planes calculated by EDR2 film and EPID, both film and EPID showed less than 2% of pixels which exceeded 1 at gamma values (r%>1) with in the thresholds such as 3%/3 mm and 2%/2 mm respectively. For the time needed for full course QA in IMRT to compare loads, EDR2 film recorded approximately 110 minutes, and EPID recorded approximately 55 minutes. Conclusion: EPID could easily replace conventional complicated and troublesome film and ionization chamber which used to be used for dosimetry and set-up verification, and it was proved to be very efficient and accurate dosimetry device in quality assurance of IMRT (intensity modulated radiation therapy). As cine mode imaging using EPID allows locating tumors in real-time without additional dose in lung and liver which are mobile according to movements of diaphragm and in rectal cancer patients who have unstable position, it may help to implement the most optimal radiotherapy for patients.

  • PDF

Scalp Dose Evaluation According Radiation Therapy Technique of Whole Brain Radiation Therapy (전뇌 방사선치료 시 치료방법에 따른 두피선량평가)

  • Jang, Joon-Yung;Park, Soo-Yun;Kim, Jong-Sik;Choi, Byeong-Gi;Song, Gi-Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.23 no.2
    • /
    • pp.103-108
    • /
    • 2011
  • Purpose: Opposing portal irradiation with helmet field shape that has been given to a patient with brain metastasis can cause excess dose in patient's scalp, resulting in hair loss. For this reason, this study is to quantitatively analyze scalp dose for effective prevention of hair loss by comparing opposing portal irradiation with scalp-shielding shape and tomotherapy designed to protect patient's scalp with conventional radiation therapy. Materials and Methods: Scalp dose was measured by using three therapies (HELMET, MLC, TOMO) after five thermo-luminescence dosimeters were positioned along center line of frontal lobe by using RANDO Phantom. Scalp dose and change in dose distribution were compared and analyzed with DVH after radiation therapy plan was made by using Radiation Treatment Planning System (Pinnacle3, Philips Medical System, USA) and 6 MV X-ray (Clinac 6EX, VARIAN, USA). Results: When surface dose of scalp by using thermo-luminescence dosimeters was measured, it was revealed that scalp dose decreased by average 87.44% at each point in MLC technique and that scalp dose decreased by average 88.03% at each point in TOMO compared with HELMET field therapy. In addition, when percentage of volume (V95%, V100%, V105% of prescribed dose) was calculated by using Dose Volume Histogram (DVH) in order to evaluate the existence or nonexistence of hotspot in scalp as to three therapies (HELMET, MLC, TOMO), it was revealed that MLC technique and TOMO plan had good dose coverage and did not have hot spot. Conclusion: Reducing hair loss of a patient who receives whole brain radiotherapy treatment can make a contribution to improve life quality of the patient. It is expected that making good use of opposing portal irradiation with scalp-shielding shape and tomotherapy to protect scalp of a patient based on this study will reduce hair loss of a patient.

  • PDF

A Study on the Compatibility of Korean Temperature Guidelines for Stockpile Material Environmental Test (저장물자 환경시험을 위한 한국적 온도기준 적합성 연구)

  • Lee, Il Ro;Byun, Kisik;Cho, Sung-Yong;Kim, Kyung Pil;Park, Jae Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.8
    • /
    • pp.187-194
    • /
    • 2020
  • The T&E (Test and Evaluation) results were applied for a judgment basis to decide the developmental process of system engineering for efficient weapon system R&D (Research and Development). During the OT&E (Operational Test and Evaluation) and DT&E (Development Test and Evaluation), an environmental test is essential for weapon system development owing to their highly exposed operational conditions. Based on the MIL-STD-810, MIL-HDBK-310, and AECTP 200, the ROK armed forces recommended operating temperatures for the ROK weapon system and applied this to the DT&E and OT&E. This study examined the compatibility of Korean temperature guidelines for stockpile material considering recent climate change. Moreover, this study analyzed the data from hourly measured temperatures on 101 observatories during 60 years, from 1960 to 2020, and percentage (0.5%, 1%, 5%, and 10%) and the 𝜎 (3𝜎, 2𝜎, and 1𝜎) frequency of occurrence on rigorous hot (August) and cold (January) periods, respectively. The results indicate that the highest temperature was 41℃, and the 0.5% frequency of occurrence was 37.0℃. In the case of the cold period, the lowest temperature was -32.6℃ and the 0.5% frequency of occurrence was -21.1℃. By considering the previously recommended operating temperature range for a general ground system, -30 ~ 40℃, regional operation probability is recognized 99.999%. Despite the recent abnormal climate change from global warming, the Korean temperature guidelines are compatible with the stockpile material environmental test.

EEPERF(Experiential Education PERFormance): An Instrument for Measuring Service Quality in Experiential Education (체험형 교육 서비스 품질 측정 항목에 관한 연구: 창의적 체험활동을 중심으로)

  • Park, Ky-Yoon;Kim, Hyun-Sik
    • Journal of Distribution Science
    • /
    • v.10 no.2
    • /
    • pp.43-52
    • /
    • 2012
  • As experiential education services are growing, the need for proper management is increasing. Considering that adequate measures are an essential factor for achieving success in managing something, it is important for managers to use a proper system of metrics to measure the performance of experiential education services. However, in spite of this need, little research has been done to develop a valid and reliable set of metrics for assessing the quality of experiential education services. The current study aims to develop a multi-item instrument for assessing the service quality of experiential education. The specific procedure is as follows. First, we generated a pool of possible metrics based on diverse literature on service quality. We elicited possiblemetric items not only from general service quality metrics such as SERVQUAL and SERVPERF but also from educational service quality metrics such as HEdPERF and PESPERF. Second, specialist teachers in the experiential education area screened the initial metrics to boost face validity. Third, we proceeded with multiple rounds of empirical validation of those metrics. Based on this processes, we refined the metrics to determine the final metrics to be used. Fourth, we examined predictive validity by checking the well-established positive relationship between each dimension of metrics and customer satisfaction. In sum, starting with the initial pool of scale items elicited from the previous literature and purifying them empirically through the surveying method, we developed a four-dimensional systemized scale to measure the superiority of experiential education and named it "Experiential Education PERFormance" (EEPERF). Our findings indicate that students (consumers) perceive the superiority of the experiential education (EE) service in the following four dimensions: EE-empathy, EE-reliability, EE-outcome, and EE-landscape. EE-empathy is a judgment in response to the question, "How empathetically does the experiential educational service provider interact with me?" Principal measures are "How well does the service provider understand my needs?," and "How well does the service provider listen to my voice?" Next, EE-reliability is a judgment in response to the question, "How reliably does the experiential educational service provider interact with me?" Major measures are "How reliable is the schedule here?," and "How credible is the service provider?" EE-outcome is a judgmentin response to the question, "What results could I get from this experiential educational service encounter?" Representative measures are "How good is the information that I will acquire form this service encounter?," and "How useful is this service encounter in helping me develop creativity?" Finally, EE-landscape is a judgment about the physical environment. Essential measures are "How convenient is the access to the service encounter?,"and "How well managed are the facilities?" We showed the reliability and validity of the system of metrics. All four dimensions influence customer satisfaction significantly. Practitioners may use the results in planning experiential educational service programs and evaluating each service encounter. The current study isexpected to act as a stepping-stone for future scale improvement. In this case, researchers may use the experience quality paradigm that has recently arisen.

  • PDF

Evaluation of Usefulness on In-vivo Diode Dosimetry for Measuring the Tumor Dose of Oral Cancer Patient (구강암 환자의 종양 선량 측정을 위한 In-vivo Diode Dosimetry의 유용성 평가)

  • Na Kyung-Su;Lee Je-Hee;Park Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.133-140
    • /
    • 2005
  • Purpose : This test is designed to identify the validity of treatment plan by implementing real-time dosimetry by means of dose that is absorbed into PTV and OAR when preparing doses of 3D and POP plans. Materials and Methods : In treatment. error can be calculated be comparing Exp. Dose with the actual dose, which has been converted from 'the reading value obtained by placing diode detector on the area to be measured'. Same test can be repeated using Alderson-Rando phantom. Results : Errors were found: A patient(POP plan): 197.6/199=-1.2%, B patient(3D-plan): 199.9/198.7=+0.6%, C patient: 196/200=-1.5%. In addition, considering the resulted value of measuring OAR besides target-dose for C patient showed 96/200, representing does of 47%, the purpose of protection was judged to be duly accomplished. Also it was acknowledged the resulted value of -3.7% met the targeted dose within the range of ${\pm}5%$. Conclusion : Aimed for identifying the usefulness of pre-treatment dose measurement using diode detector, this test was useful to evaluate the validity of curing because it resulted in the identification of category to be protected as well as t dose. Moreover, it is thought to have great advantage in ascertaining the dose of target, dose of which is not calculated yet. Similar to L-gram before treatment, this test is thought to be very effective so that it can bring great advantages in the aspects such as validity of curing method and post-treatment plan as well.

  • PDF

Ultrasonographic Assessment for Rotator Cuff Repair According to the Tear Sizes and the Repair Method (회전근 개 파열의 크기 및 봉합 방법에 따른 초음파를 이용한 추적검사의 유용성)

  • Choi, Chang-Hyuk;Park, Jae-Hyun;Shin, Dong-Young;Lee, Jae-Kun
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.2 no.2
    • /
    • pp.53-61
    • /
    • 2009
  • Purpose: This study was designed to evaluate the clinical usefulness of serial ultrasonography (USG) after arthroscopic rotator cuff repair and to assess the re-tear rate and the re-tear time according to the tear sizes and the repair method. Materials and Methods: Between January 2008 and June 2008, 52 patients were treated with arthroscopic rotator cuff repair, Of the 52 patients, 29 patients that had undergone more than six months follow-up underwent preoperative USG examinations and subsequent arthroscopic examinations. MRI and USG findings were compared with intraoperative results of arthroscopic examinations. The postoperative integrity of the rotator cuff was observed using serial USG examination performed postoperatively at two weeks, six weeks, three months, and six months. Results: Small to medium rotator cuff tear were identified in 10 patients where the double pulley suture bridge (DPSB) technique was performed; the re-tear rate was 20%. For 19 patients with large to massive rotator cuff tears, the re-tear rates was 100% for six patients who had undergone tendon to tendon (TT) repair, the re-tear rate was 50% for two patients who had undergone tendon to tendon and bone to tendon (TTBT) repair and the re-tear rate was 55% for11 patients where the DPSB technique was performed. Re-tear rates according to follow-up periods were 7% from two to six weeks, 66% from six weeks to three months and 27% from three to six months postoperatively. Conclusion: Serial USG examinations after arthroscopic rotator cuff repair were useful to assess the re-tear rate and the re-tear time. In addition, USG examination were useful for treatment planning during postoperative rehabilitation.

  • PDF