• Title/Summary/Keyword: Park planning

Search Result 4,350, Processing Time 0.038 seconds

Comparison of Carbon Storage Based on Alternative Action by Land Use Planning (토지이용에 따른 대안별 탄소 저장량 비교)

  • Seulki Koo;Youngsoo Lee;Sangdon Lee
    • Journal of Environmental Impact Assessment
    • /
    • v.32 no.6
    • /
    • pp.377-388
    • /
    • 2023
  • Carbon management is emerging as an important factor for global warming control, and land use change is considered one of the causes. To quantify the changes in carbon stocks due to development, this study attempted to calculate carbon storage by borrowing the formula of the InVEST Carbon Storage and Sequestration Model (InVEST Model). Before analyzing carbon stocks, a carbon pool was compiled based on previous studies in Korea. Then, we estimated the change in carbon stocks according to the development of Osong National Industrial Park (ONIP) and the application of alternatives. The analysis shows that 16,789.5 MgC will be emitted under Alternative 1 and 16,305.3 MgC under Alternative 2. These emissions account for 44.4% and 43.1% of the pre-project carbon stock, respectively, and shows that choosing Alternative 2 is advantageous for reducing carbon emissions. The difference is likely due to the difference in grassland area between Alternatives 1 and 2. Even if Alternative 2 is selected, efforts are needed to increase the carbon storage effect by managing the appropriate level of green cover in the grassland, creating multi-layered vegetation, and installing low-energy facilities. In addition, it is suggested to conserve wetlands that can be lost during the stream improvement process or to create artificial wetlands to increase carbon storage. The assessment of carbon storage using carbon pools by land cover can improve the objectivity of comparison and evaluation analysis results for land use plans in Environmental Impact Assessment and Strategic Environmental Impact Assessment. In addition, the carbon pool generated in this study is expected to be used as a basis for improving the accuracy of such analyses.

A Study Concerning Health Needs in Rural Korea (농촌(農村) 주민(住民)들의 의료필요도(醫療必要度)에 관(關)한 연구(硏究))

  • Lee, Sung-Kwan;Kim, Doo-Hie;Jung, Jong-Hak;Chunge, Keuk-Soo;Park, Sang-Bin;Choy, Chung-Hun;Heng, Sun-Ho;Rah, Jin-Hoon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.7 no.1
    • /
    • pp.29-94
    • /
    • 1974
  • Today most developed countries provide modern medical care for most of the population. The rural area is the more neglected area in the medical and health field. In public health, the philosophy is that medical care for in maintenance of health is a basic right of man; it should not be discriminated against racial, environmental or financial situations. The deficiency of the medical care system, cultural bias, economic development, and ignorance of the residents about health care brought about the shortage of medical personnel and facilities on the rural areas. Moreover, medical students and physicians have been taught less about rural health care than about urban health care. Medical care, therefore, is insufficient in terms of health care personnel/and facilities in rural areas. Under such a situation, there is growing concern about the health problems among the rural population. The findings presented in this report are useful measures of the major health problems and even more important, as a guide to planning for improved medical care systems. It is hoped that findings from this study will be useful to those responsible for improving the delivery of health service for the rural population. Objectives: -to determine the health status of the residents in the rural areas. -to assess the rural population's needs in terms of health and medical care. -to make recommendations concerning improvement in the delivery of health and medical care for the rural population. Procedures: For the sampling design, the ideal would be to sample according to the proportion of the composition age-groups. As the health problems would be different by group, the sample was divided into 10 different age-groups. If the sample were allocated by proportion of composition of each age group, some age groups would be too small to estimate the health problem. The sample size of each age-group population was 100 people/age-groups. Personal interviews were conducted by specially trained medical students. The interviews dealt at length with current health status, medical care problems, utilization of medical services, medical cost paid for medical care and attitudes toward health. In addition, more information was gained from the public health field, including environmental sanitation, maternal and child health, family planning, tuberculosis control, and dental health. The sample Sample size was one fourth of total population: 1,438 The aged 10-14 years showed the largest number of 254 and the aged under one year was the smallest number of 81. Participation in examination Examination sessions usually were held in the morning every Tuesday, Wenesday, and Thursday for 3 hours at each session at the Namchun Health station. In general, the rate of participation in medical examination was low especially in ages between 10-19 years old. The highest rate of participation among are groups was the under one year age-group by 100 percent. The lowest use rate as low as 3% of those in the age-groups 10-19 years who are attending junior and senior high school in Taegu city so the time was not convenient for them to recieve examinations. Among the over 20 years old group, the rate of participation of female was higher than that of males. The results are as follows: A. Publie health problems Population: The number of pre-school age group who required child health was 724, among them infants numbered 96. Number of eligible women aged 15-44 years was 1,279, and women with husband who need maternal health numbered 700. The age-group of 65 years or older was 201 needed more health care and 65 of them had disabilities. (Table 2). Environmental sanitation: Seventy-nine percent of the residents relied upon well water as a primary source of dringking water. Ninety-three percent of the drinking water supply was rated as unfited quality for drinking. More than 90% of latrines were unhygienic, in structure design and sanitation (Table 15). Maternal and child health: Maternal health Average number of pregnancies of eligible women was 4 times. There was almost no pre- and post-natal care. Pregnancy wastage Still births was 33 per 1,000 live births. Spontaneous abortion was 156 per 1,000 live births. Induced abortion was 137 per 1,000 live births. Delivery condition More than 90 percent of deliveries were conducted at home. Attendants at last delivery were laymen by 76% and delivery without attendants was 14%. The rate of non-sterilized scissors as an instrument used to cut the umbilical cord was as high as 54% and of sickles was 14%. The rate of difficult delivery counted for 3%. Maternal death rate estimates about 35 per 10,000 live births. Child health Consultation rate for child health was almost non existant. In general, vaccination rate of children was low; vaccination rates for children aged 0-5 years with BCG and small pox were 34 and 28 percent respectively. The rate of vaccination with DPT and Polio were 23 and 25% respectively but the rate of the complete three injections were as low as 5 and 3% respectively. The number of dead children was 280 per 1,000 living children. Infants death rate was 45 per 1,000 live births (Table 16), Family planning: Approval rate of married women for family planning was as high as 86%. The rate of experiences of contraception in the past was 51%. The current rate of contraception was 37%. Willingness to use contraception in the future was as high as 86% (Table 17). Tuberculosis control: Number of registration patients at the health center currently was 25. The number indicates one eighth of estimate number of tuberculosis in the area. Number of discharged cases in the past accounted for 79 which showed 50% of active cases when discharged time. Rate of complete treatment among reasons of discharge in the past as low as 28%. There needs to be a follow up observation of the discharged cases (Table 18). Dental problems: More than 50% of the total population have at least one or more dental problems. (Table 19) B. Medical care problems Incidence rate: 1. In one month Incidence rate of medical care problems during one month was 19.6 percent. Among these health problems which required rest at home were 11.8 percent. The estimated number of patients in the total population is 1,206. The health problems reported most frequently in interviews during one month are: GI trouble, respiratory disease, neuralgia, skin disease, and communicable disease-in that order, The rate of health problems by age groups was highest in the 1-4 age group and in the 60 years or over age group, the lowest rate was the 10-14 year age group. In general, 0-29 year age group except the 1-4 year age group was low incidence rate. After 30 years old the rate of health problems increases gradually with aging. Eighty-three percent of health problems that occured during one month were solved by primary medical care procedures. Seventeen percent of health problems needed secondary care. Days rested at home because of illness during one month were 0.7 days per interviewee and 8days per patient and it accounts for 2,161 days for the total productive population in the area. (Table 20) 2. In a year The incidence rate of medical care problems during a year was 74.8%, among them health problems which required rest at home was 37 percent. Estimated number of patients in the total population during a year was 4,600. The health problems that occured most frequently among the interviewees during a year were: Cold (30%), GI trouble (18), respiratory disease (11), anemia (10), diarrhea (10), neuralgia (10), parasite disease (9), ENT (7), skin (7), headache (7), trauma (4), communicable disease (3), and circulatory disease (3) -in that order. The rate of health problems by age groups was highest in the infants group, thereafter the rate decreased gradually until the age 15-19 year age group which showed the lowest, and then the rate increased gradually with aging. Eighty-seven percent of health problems during a year were solved by primary medical care. Thirteen percent of them needed secondary medical care procedures. Days rested at home because of illness during a year were 16 days per interviewee and 44 days per patient and it accounted for 57,335 days lost among productive age group in the area (Table 21). Among those given medical examination, the conditions observed most frequently were respiratory disease, GI trouble, parasite disease, neuralgia, skin disease, trauma, tuberculosis, anemia, chronic obstructive lung disease, eye disorders-in that order (Table 22). The main health problems required secondary medical care are as fellows: (previous page). Utilization of medical care (treatment) The rate of treatment by various medical facilities for all health problems during one month was 73 percent. The rate of receiving of medical care of those who have health problems which required rest at home was 52% while the rate of those who have health problems which did not required rest was 61 percent (Table 23). The rate of receiving of medical care for all health problems during a year was 67 percent. The rate of receiving of medical care of those who have health problems which required rest at home was 82 percent while the rate of those who have health problems which did not required rest was as low as 53 percent (Table 24). Types of medical facilitied used were as follows: Hospital and clinics: 32-35% Herb clinics: 9-10% Drugstore: 53-58% Hospitalization Rate of hospitalization was 1.7% and the estimate number of hospitalizations among the total population during a year will be 107 persons (Table 25). Medical cost: Average medical cost per person during one month and a year were 171 and 2,800 won respectively. Average medical cost per patient during one month and a year were 1,109 and 3,740 won respectively. Average cost per household during a year was 15,800 won (Table 26, 27). Solution measures for health and medical care problems in rural area: A. Health problems which could be solved by paramedical workers such as nurses, midwives and aid nurses etc. are as follows: 1. Improvement of environmental sanitation 2. MCH except medical care problems 3. Family planning except surgical intervention 4. Tuberculosis control except diagnosis and prescription 5. Dental care except operational intervention 6. Health education for residents for improvement of utilization of medical facilities and early diagnosis etc. B. Medical care problems 1. Eighty-five percent of health problems could be solved by primary care procedures by general practitioners. 2. Fifteen percent of health problems need secondary medical procedures by a specialist. C. Medical cost Concidering the economic situation in rural area the amount of 2,062 won per residents during a year will be burdensome, so financial assistance is needed gorvernment to solve health and medical care problems for rural people.

  • PDF

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

Moderating Effect of Lifestyle on Consumer Behavior of Loungewear with Korean Traditional Fashion Design Elements (소비자대함유한국전통시상설계원소적편복적소비행위지우생활방식적조절작용(消费者对含有韩国传统时尚设计元素的便服的消费行为之于生活方式的调节作用))

  • Ko, Eun-Ju;Lee, Jee-Hyun;Kim, Angella Ji-Young;Burns, Leslie Davis
    • Journal of Global Scholars of Marketing Science
    • /
    • v.20 no.1
    • /
    • pp.15-26
    • /
    • 2010
  • Due to the globalization across various industries and cultural trade among many countries, oriental concepts have been attracting world’s attentions. In fashion industry, one's traditional culture is often developed as fashion theme for designers' creation and became strong strategies to stand out among competitors. Because of the increase of preferences for oriental images, opportunities abound to introduce traditional fashion goods and expand culture based business to global fashion markets. However, global fashion brands that include Korean traditional culture are yet to be developed. In order to develop a global fashion brand with Korean taste, it is very important for native citizen to accept their own culture in domestic apparel market prior to expansion into foreign market. Loungewear is evaluated to be appropriate for adopting Korean traditional details into clothing since this wardrobe category embraces various purposes which will easily lead to natural adaptation and wide spread use. Also, this market is seeing an increased demand for multipurpose wardrobes and fashionable underwear (Park et al. 2009). Despite rapid growth in the loungewear market, specific studies of loungewear is rare; and among research on developing modernized-traditional clothing, fashion items and brands do not always include the loungewear category. Therefore, this study investigated the Korean loungewear market and studied consumer evaluation toward loungewear with Korean traditional fashion design elements. Relationship among antecedents of purchase intention for Korean traditional fashion design elements were analyzed and compared between lifestyle groups for consumer targeting purposes. Product quality, retail service quality, perceived value, and preference on loungewear with Korean traditional design elements were chosen as antecedents of purchase intention and a structural equation model was designed to examine their relationship as well as their influence on purchase intention. Product quality and retail service quality among marketing mixes were employed as factors affecting preference and perceived value of loungewear with Korean traditional fashion design elements. Also effects of preference and perceived value on purchase intention were examined through the same model. A total of 357 self-administered questionnaires were completed by female consumers via web survey system. A questionnaire was developed to measure samples' lifestyle, product and retail service quality as purchasing criteria, perceived value, preference and purchase intention of loungewear with Korean traditional fashion design elements. Also, loungewear purchasing and usage behavior were asked as well in order to examine Korean loungewear market status. Data was analyzed through descriptive analysis, factor analysis, cluster analysis, ANOVA and structural equation model was tested via AMOS 7.0. As for the result of Korean loungewear market status investigation, loungewear was purchased by most of the consumers in our sample. Loungewear is currently recognized as clothes that are worn at home and consumers are showing comparably low involvement toward loungewear. Most of consumers in this study purchase loungewear only two to three times a year and they spend less than US$10. A total of 12 items and four factors of loungewear consumer lifestyle were found: traditional value oriented lifestyle, brand-affected lifestyle, pursuit of leisure lifestyle, and health oriented lifestyle. Drawing on lifestyle factors, loungewear consumers were classified into two groups; Well-being and Conservative. Relationships among constructs of purchasing behavior related to loungewear with Korean traditional fashion design elements were estimated. Preference and perceived value of loungewear were affected by both product quality and retail service quality. This study proved that high qualities in product and retail service develop positive preference toward loungewear. Perceived value and preference of loungewear positively influenced purchase intention. The results indicated that high preference and perceived value of loungewear with Korean traditional fashion design elements strengthen purchase intention and proved importance of developing preference and elevate perceived value in order to make sales. In a model comparison between two lifestyle groups: Well-being and Conservative lifestyle groups, results showed that product quality and retail service quality had positive influences on both preference and perceived value in case of Well-being group. However, for Conservative group, only retail service quality had a positive effect on preference and its influence to purchase intention. Since Well-being group showed more significant influence on purchase intention, loungewear brands with Korean traditional fashion design elements may want to focus on characteristics of Well-being group. However, Conservative group's relationship between preference and purchase intention of loungewear with Korean traditional fashion design elements was stronger, so that loungewear brands with Korean traditional fashion design elements should focus on creating conservative consumers' positive preference toward loungewear. The results offered information on Korean loungewear consumers' lifestyle and provided useful information for fashion brands that are planning to enter Korean loungewear market, particularly targeting female consumers similar to the sample of the present study. This study offers strategic and marketing insight for loungewear brands and also for fashion brands that are planning to create highly value-added fashion brands with Korean traditional fashion design elements. Considering different types of lifestyle groups that are associated with loungewear or traditional fashion goods, brand managers and marketers can use the results of this paper as a reference to positioning, targeting and marketing strategy buildings.

Efficacy and Accuracy of Patient Specific Customize Bolus Using a 3-Dimensional Printer for Electron Beam Therapy (전자선 빔 치료 시 삼차원프린터를 이용하여 제작한 환자맞춤형 볼루스의 유용성 및 선량 정확도 평가)

  • Choi, Woo Keun;Chun, Jun Chul;Ju, Sang Gyu;Min, Byung Jun;Park, Su Yeon;Nam, Hee Rim;Hong, Chae-Seon;Kim, MinKyu;Koo, Bum Yong;Lim, Do Hoon
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.64-71
    • /
    • 2016
  • We develop a manufacture procedure for the production of a patient specific customized bolus (PSCB) using a 3D printer (3DP). The dosimetric accuracy of the 3D-PSCB is evaluated for electron beam therapy. In order to cover the required planning target volume (PTV), we select the proper electron beam energy and the field size through initial dose calculation using a treatment planning system. The PSCB is delineated based on the initial dose distribution. The dose calculation is repeated after applying the PSCB. We iteratively fine-tune the PSCB shape until the plan quality is sufficient to meet the required clinical criteria. Then the contour data of the PSCB is transferred to an in-house conversion software through the DICOMRT protocol. This contour data is converted into the 3DP data format, STereoLithography data format and then printed using a 3DP. Two virtual patients, having concave and convex shapes, were generated with a virtual PTV and an organ at risk (OAR). Then, two corresponding electron treatment plans with and without a PSCB were generated to evaluate the dosimetric effect of the PSCB. The dosimetric characteristics and dose volume histograms for the PTV and OAR are compared in both plans. Film dosimetry is performed to verify the dosimetric accuracy of the 3D-PSCB. The calculated planar dose distribution is compared to that measured using film dosimetry taken from the beam central axis. We compare the percent depth dose curve and gamma analysis (the dose difference is 3%, and the distance to agreement is 3 mm) results. No significant difference in the PTV dose is observed in the plan with the PSCB compared to that without the PSCB. The maximum, minimum, and mean doses of the OAR in the plan with the PSCB were significantly reduced by 9.7%, 36.6%, and 28.3%, respectively, compared to those in the plan without the PSCB. By applying the PSCB, the OAR volumes receiving 90% and 80% of the prescribed dose were reduced from $14.40cm^3$ to $0.1cm^3$ and from $42.6cm^3$ to $3.7cm^3$, respectively, in comparison to that without using the PSCB. The gamma pass rates of the concave and convex plans were 95% and 98%, respectively. A new procedure of the fabrication of a PSCB is developed using a 3DP. We confirm the usefulness and dosimetric accuracy of the 3D-PSCB for the clinical use. Thus, rapidly advancing 3DP technology is able to ease and expand clinical implementation of the PSCB.

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Evaluation of usefulness of the Gated Cone-beam CT in Respiratory Gated SBRT (호흡동조 정위체부방사선치료에서 Gated Cone-beam CT의 유용성 평가)

  • Hong sung yun;Lee chung hwan;Park je wan;Song heung kwon;Yoon in ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.61-72
    • /
    • 2022
  • Purpose: Conventional CBCT(Cone-beam Computed-tomography) caused an error in the target volume due to organ movement in the area affected by respiratory movement. The purpose of this paper is to evaluate the usefulness of accuracy and time spent using the Gated CBCT function, which reduces errors when performing RGRT(respiratory gated radiation therapy), and to examine the appropriateness of phase. Materials and methods: To evaluate the usefulness of Gated CBCT, the QUASARTM respiratory motion phantom was used in the Truebeam STxTM. Using lead marker inserts, Gated CBCT was scaned 5 times for every 20~80% phase, 30~70% phase, and 40~60% phase to measure the blurring length of the lead marker, and the distance the lead marker moves from the top phase to the end of the phase was measured 5 times. Using Cedar Solid Tumor Inserts, 4DCT was scanned for every phase, 20-80%, 30-70%, and 40-60%, and the target volume was contoured and the length was measured five times in the axial direction (S-I direction). Result: In Gated CBCT scaned using lead marker inserts, the axial moving distance of the lead marker on average was measured to be 4.46cm in the full phase, 3.11cm in the 20-80% phase, 1.94cm in the 30-70% phase, 0.90cm in the 40-60% phase. In Fluoroscopy, the axial moving distance of the lead marker on average was 4.38cm and the distance on average from the top phase to the beam off phase was 3.342cm in the 20-80% phase, 3.342cm in the 30-70% phase, and 0.84cm in the 40-60% phase. Comparing the results, the difference in the full phase was 0.08cm, the 20~80% phase was 0.23cm, the 30~70% phase was 0.10cm, and the 40~60% phase was 0.07cm. The axial lengths of ITV(Internal Target Volume) and PTV(Planning Target Volume) contoured by 4DCT taken using cedar solid tumor inserts were measured to be 6.40cm and 7.40cm in the full phase, 4.96cm and 5.96cm in the 20~80% phase, 4.42cm and 5.42cm in the 30~70% phase, and 2.95cm and 3.95cm in the 40~60% phase. In the Gated CBCT, the axial lengths on average was measured to be 6.35 cm in the full phase, 5.25 cm in the 20-80% phase, 4.04 cm in the 30-70% phase, and 3.08 cm in the 40-60% phase. Comparing the results, it was confirmed that the error was within ±8.5% of ITV Conclusion: Conventional CBCT had a problem that errors occurred due to organ movement in areas affected by respiratory movement, but through this study, obtained an image similar to the target volume of the setting phase using Gated CBCT and verified its usefulness. However, as the setting phase decreases, the scan time was increases. Therefore, considering the scan time and the error in setting phase, It is recommended to apply it to patients with respiratory coordinated stereotactic radiation therapy using a wide phase of 30-70% or more.

Verification of skin dose according to the location of tumor in Tomotherapy (토모테라피 시 종양의 위치에 따른 피부선량 검증)

  • Yoon, Bo Reum;Park, Su Yeon;Park, Byoung Suk;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.273-280
    • /
    • 2014
  • Purpose : To verify the skin dose in Tomotherapy-based radiation treatment according to the change in tumor locations, skin dose was measured by using Gafchromic EBT3 film and compared with the planned doses to find out the gap between them. Materials and Methods : In this study, to measure the skin dose, I'm RT Phantom(IBA Dosimetry, Germany) was utilized. After obtaining the 2.5mm CT images, tumor locations and skin dose measuring points were set by using Pinnacle(ver 9.2, Philips Medical System, USA). The tumor location was decided to be 5mm and 10mm away from surface of the phantom and center. Considering the attenuation of a Tomo-couch, we ensured a symmetric placement between the ceiling and floor directions of the phantom. The measuring point of skin doses was set to have 3mm and 5mm thickness from the surface. Measurement was done 3 times. By employing TomoHD(TomoHD treatment system, Tomotherapy Inc., Madison, Wisconsin, USA), we devised Tomotherapy plans, measured 3 times by inserting Gafchromic EBT3 film into the phantom and compared the measurement with the skin dose treatment plans. Results : The skin doses in the upper part of the phantom, when the tumor was located in the center, were found to be 7.53 cGy and 7.25 cGy in 5mm and 3mm respectively. If placed 5mm away from the skin in the ceiling direction, doses were 18.06 cGy and 16.89 cGy; if 10mm away, 20.37 cGy and 18.27 cGy, respectively. The skin doses in the lower part of the phantom, when the tumor was located in the center, recorded 8.82 cGy and 8.29 cGy in 5mm and 3mm, each; if located 5mm away from the lower part skin, 21.69 cGy and 19.78 cGy were respectively recorded; and if 10mm away, 20.48 cGy and 19.57 cGy were recorded. If the tumor was placed in the center, skin doses were found to increase by 3.2~17.1% whereas if the tumor is 5mm away from the ceiling part, the figure decreased to 2.8~9.0%. To the Tomo-couch direction, skin doses showed an average increase of 11% or over, compared to the planned treatment. Conclusion : This study found gaps between planned skin doses and actual doses in the Tomotherapy treatment planning. Especially to the Tomo-cocuh direction, skin doses were found to be larger than the planned doses. Thus, during the treatment of tumors near the Tomo-couch, doses will need to be more accurately calculated and more efforts to verify skin doses will be required as well.

Comparison of Dose Distribution in Spine Radiosurgery Plans: Simultaneously Integrated Boost and RTOG 0631 Protocol (척추뼈전이암 환자의 체부정위방사선치료계획 비교: 동시통합추가치료법 대 RTOG 0631 프로토콜)

  • Park, Su Yeon;Oh, Dongryul;Park, Hee Chul;Kim, Jin Sung;Kim, Jong Sik;Shin, Eun Hyuk;Kim, Hye Young;Jung, Sang Hoon;Han, Youngyih
    • Progress in Medical Physics
    • /
    • v.25 no.3
    • /
    • pp.176-184
    • /
    • 2014
  • In this study, we compared dose distributions from simultaneously integrated boost (SIB) method versus the RTOG 0631 protocol for spine radiosurgery. Spine radiosurgery plans were performed in five patients with localized spinal metastases from hepatocellular carcinoma. The computed tomography (CT) and T1- and T2-weighted magnetic resonance imaging (MRI) were fused for delineating of GTV and spinal cord. In SIB plan, the clinical target volume (CTV1) was included the whole compartments of the involved spine, while RTOG 0631 protocol defines the CTV2 as the involved vertebral body and both left and right pedicles. The CTV2 includes transverse process and posterior element according to the extent of GTV. The doses were prescribed 18 Gy to GTV and 10 Gy to CTV1 in SIB plan, while the prescription of RTOG 0631 protocol was applied 18 Gy to CTV2. The results of dose-volume histogram (DVH) showed that there were competitive in target coverage, while the doses of spinal cord and other normal organs were lower in SIB method than in RTOG 0631 protocol. The 85% irradiated volume of VB in RTOG 0631 protocol was similar to that in the SIB plan. However, the dose to normal organs in RTOG 0631 had a tendency to higher than that in SIB plan. The SIB plan might be an alternative method in case of predictive serious complications of surrounded normal organs. In conclusion, although both approaches of SIB or RTOG 0631 showed competitive planning results, tumor control probability (TCP) and normal tissue complication probability (NTCP) through diverse clinical researches should be analyzed in the future.