• 제목/요약/키워드: Park Se-Mu

검색결과 416건 처리시간 0.036초

Black-spotted porcupine fish에서의 Proteus vulgaris 감염증 (Infectious of Proteus vulgaris in Black-spotted Porcupine Fish)

  • 김지형;백근욱;김경연;오태엽;데니스 고메즈;박세창
    • 한국임상수의학회지
    • /
    • 제24권1호
    • /
    • pp.42-45
    • /
    • 2007
  • The genus Proteus has been rarely isolated from cultured fish. In this study, we reported Proteus vulgaris isolated from fish skin lesion of Black-spotted porcupine fish (Diodon hystrix). Identification of f vulgaris was performed by general biological test, including API 20E and API ZYM. The sensitivity of isolated strains to different groups of antibiotics was evaluated using the disc diffusion method. It showed that the isolate is sensitive to ciprofloxacin $(5{\mu}g)$, norfloxacin $(10{\mu}g)$, enrofloxacin $(5{\mu}g)$, cefotaxime $(30{\mu}g)$.

ZnSe 박막 성장을 위한 Molecular Beam Epitaxy 성장 조건의 결정

  • 정명훈;박승환;김광희;정미나;양민;안형수;장지호;김홍승;송준석
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 춘계종합학술대회
    • /
    • pp.990-994
    • /
    • 2005
  • II-VI족 화합물 반도체를 성장하기 위한 MBE 성장 조건으로서 성장 온도, flux 율, 성장률에 대해 연구하였다. 성장 온도, flux 율, 성장률은 각각 290 $^{\circ}C$, 2, 0.6 ${\mu}m$/hr로 조절되었다. 위와 같이 설정된 성장 조건에서 단결정 성장을 확인하기 위하여 ZnSe 박막을 성장하였다. 성장된 박막의 AFM 측정 결과, 박막의 표면은 비교적 거칠었으며 (RMS ${\sim}$ 2.9 nm) 이는 낮은 성장 온도, 빠른 성장률로 인한 것임을 알 수 있었다. 그리고 XRD 측정 결과는 박막의 두께가 임계 두께를 넘어서 격자 정수의 부정합이 완화되었음을 보여주었다. XRD를 이용한 비파괴 방법으로 전위 밀도를 구하기 위해 (002), (004), (115), (006) 면에 대해 XRD를 측정하여 박막 내 전위밀도를 구하였다. XRD 측정 결과를 이용하여 계산한 결과 전위 밀도는 8.30${\times}10^8$ dis/cm$^2$로 종래의 연구와 비슷한 수준의 박막이 구현되었음을 알 수 있었다.

  • PDF

다양한 유산균이 존재하는 발효식품으로 부터 Bifidobacteria의 선별 및 계수 (Selection and Enumeration of Bifidobacteria in Fermented Foods with Various Lactic Bacteria)

  • 이시경;박동기;오훈일;박종현
    • 한국식품과학회지
    • /
    • 제31권3호
    • /
    • pp.751-756
    • /
    • 1999
  • Bifidobacteria를 다양한 유산균이 함께 공존하는 발효식품에 첨가시 이들을 분리할 수 있는 선택배지를 제조하기 위해 다양한 항생제의 생육저해 효과를 조사하였다. Gentamycin과 ripampicin은 $100\;{\mu}g/mL$의 농도에서 일반 유산균의 생육을 심하게 억제하였으나, bifidobacteria의 생육은 억제하지 않았다. ampicillin은 $50\;{\mu}g/mL$의 농도에서 일반 유산균은 거의 생육하지 못하였으나, bifidobacteria의 생육도 억제되었다. fosfomycin은 $100\;{\mu}g/mL$이상의 농도에서 일반 유산균보다 bifidobacteria의 생육이 더 억제되었다. Neomycin $80\;{\mu}g/mL$, gentamycin $50\;{\mu}g/mL$, ripampicin $50\;{\mu}g/mL$, nalidixic acid $15\;{\mu}g/mL$, $LiCl_2$ $3\;{\mu}g/mL$의 항생제가 함유된 MRS배지를 이용하였을 때 김치나 치즈에 존재하는 다양한 유산균의 생육을 억제시키지만 bifidobacteria의 생육을 억제시키지 않아 이를 선택적으로 분리할 수 있었다.

  • PDF

비정질 셀레늄을 이용한 직접방식의 디지털 방사선 검출기와 X-ray film과의 MTF측정을 통한 영상 질(quality) 비교평가에 관한 연구 (Comparison Study of the Modulation Transfer Function of a Prototype a-Se based Flat Panel Detector with Conventional Speed Class 400 Film/screen System)

  • Park, Jang-Yong;Park, Ji-Koon;Kang, Sang-Sik;Moon, Chi-Woong;Lee, Hyung-Won;Nam, Sang-Hee
    • 전자공학회논문지SC
    • /
    • 제40권3호
    • /
    • pp.163-171
    • /
    • 2003
  • 디지털 방사선 검출기의 성능을 측정하기 위해 변조전달할수(Modulation Transfer Function)을 측정하여 기존 방사선 영상 시스템인 필름/스크린과 비교하였다. 제작된 디지털 방사선 검출기는 TFT 패널위에 진공 증착법을 통해 비정질 셀레늄이 코팅되었다. 비교 측정물이 감도 400의 필름/스크린은 아날로그 방식의 방사선 검출기로서 현재 임상에서 이용되고 있는 필름이다. Square wave & slit 측정법을 통해 두 시스템의 변조전달함수를 측정하였다. 필름/스핀린의 반치폭(FWHM)은 357㎛(1.4 lp/mm at 50% spatial frequency)으로 측정되었으며, 디지털 방사선 검출 시스템은 200㎛(2.5 lp/mm at 50%)였다. 영상의 표현성능 평가의 결과 디지털 방사선 시스템은 필름 시스템보다 높은 것으로 나타났다.

삭제기구가 자가 산부식 접착제의 미세누출에 미치는 영향 (EFFECT OF MICROLEAKAGE OF A SELF-ETCHING PRIMER ADHESIVE ACCORDING TO TYPES OF CUTTING INSTRUMENTS)

  • 김용희;박재구;조영곤
    • Restorative Dentistry and Endodontics
    • /
    • 제32권4호
    • /
    • pp.327-334
    • /
    • 2007
  • 이 연구는 서로 다른 카바이드 버와 다이아몬드 버로 5급 와동을 형성 한 후 SE primer 접착 시스템인 Clearfil SE Bond를 이용한 복합레진 수복 시 버의 종류에 따른 법랑질과 상아질 변연에서의 미세누출 차이를 상호 비교하기 위하여 시행하였다. 4종의 삭제기구를 이용하여 각각 10개의 발거된 대구치의 협면 치경부에 5급 와동을 형성하였다. 1군은 plain-cut carbide fissure bur (no. 245)를 사용한 군, 2군은 cross-cut carbide fissure bur (no. 557)를 사용한 군, 3군은 fine diamond bur (TF-21F: 입자크기 $53\;-\;63\;{\mu}m$)를 사용한 군, 4군은 standard diamond bur (EX-41: 입자크기 $106\;-\;205\;{\mu}m$)를 사용한 군으로 분류하였다. 형성된 와동에 Clearfil SE Bond의 Primer와 Bond를 적용하고 Clearfil AP-X 복합레진을 충전하여 광중합한 후, Sof-Lex disc를 이용하여 마무리와 연마를 시행하였다. 수복된 치아를 2% methylene blue 용액에 24시간 동안 침적시킨 후 각 군의 치아를 협설로 절단하여 광학 입체현미경 하에서 법랑질과 상아질 변연에서의 미세누출 점수를 평가하여 다음과 같은 결과를 얻었다. Clearfil SE Bond와 복합레진을 이용한 5급 와동 수복 시 거친 다이아몬드 버의 사용은 카바이드 버나 미세한 다이아몬드 버에 비해 법랑질과 상아질 변연 모두에서 높은 미세누출을 나타내었다.

형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성 (Characterization of the a-Se Film for Phosphor based X-ray light Modulator)

  • 강상식;박지군;조성호;차병열;신정욱;이건환;문치웅;남상희
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Silicon-micromachined Microneedle for Suction and Injection of Bio Samples

  • Paik, Seung-Joon;Kim, Jong-Pal;Kim, Se-Tae;Park, Sang-Jun;Chung, Seok;Chang, Jun-Keum;Chun, Kuk-Jin;Cho, Dong-Il
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.178.6-178
    • /
    • 2001
  • Silicon-micromachined microneedle for a biofluid diagnosis system is developed. To fabricate microneedles, two sets of processes are used. One is making buried microchannels in silicon wafer using silicon isotropic etch with a SF6 plasma and then trench-refilling. The other is releasing the body of the microneedle by deep silicon etch. The microneedle has a 4 mm-length and about 12 $\mu\textrm{m}$ diameter buried microchannel, a 1.5 mm$\times$l.5 mm-area reservoir, and about 180 $\mu\textrm{m}$thickness body. Preliminary results indicate that microneedles are capable of flowing fluidic samples. The microneedle with a buried microchannel is expected to be integrated with in vitro diagnosis systems and microfluidic devices.

  • PDF

$Pr^{3+}$ 첨가 찰코할라이드 유리의 광학적 특성 (Optical Properties of $Pr^{3+}$-Doped Chalcohalide Glasses)

  • 최용규;강봉훈;송재혁;정운진;허종;박봉제;서홍석;안준태
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2007년도 동계학술발표회 논문집
    • /
    • pp.143-144
    • /
    • 2007
  • 낮은 포논 에너지를 가지는 대표적인 비정질 광소재인 Ge-Ga-Sb-Se 조성의 셀레나이드 유리에 CsI를 첨가한 찰코할라이드 유리 샘플을 제작하고 CsI 함량에 따른 소재의 광 특성 및 첨가된 $Pr^{3+}$ 이온의 광 특성 변화를 조사하였다. 안정한 비정질 상태를 유지하는 CsI의 함량은 약 7.5 몰%로 제한되었으며, 첨가량에 비례하여 단파장 흡수단 파장이 짧아지는 경향을 보였으나 weak absorption tail이 증가 하였다. $Pr^{3+}$ 이온으로부터 발생하는 1.6 ${\mu}m$대역 형광의 제반특성은 CsI의 첨가와 비교적 무관한 것으로 밝혀졌으며 1.06 ${\mu}m$장에서 측정한 비선형 흡수 계수 역시 CsI의 첨가에 영향을 거의 받지 않는 것으로 판명되었다.

  • PDF

Analysis of the Influence of the Address Electrode Width on High-speed Addressing Using the Vt Close Curve and Dynamic Vdata Margin

  • Kim, Yong-Duk;Park, Se-Kwang
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제5C권5호
    • /
    • pp.183-190
    • /
    • 2005
  • In order to drive the high-density plasma displays, a high-speed driving technology must be researched. In this experiment, the relationship between the width of the address electrode and high-speed driving is analyzed using the Vt close curve and the panel structure for high-speed driving is proposed. In addition we show that the wider the width of the address electrode is, the narrower the width of the scan pulse becomes. Therefore, we could achieve the minimum data voltage of 50.1V at a scan pulse width of $1.0/{\mu}s$ and a ramp voltage of 210V at an address electrode width of $180/{\mu}m$ for the high-speed driving 4-inch test PDP.

부분 정보에 기반한 효과적인 음악 무드 분류 방법 (Effective Mood Classification Method based on Music Segments)

  • 박근한;박상용;강석중
    • 한국멀티미디어학회논문지
    • /
    • 제10권3호
    • /
    • pp.391-400
    • /
    • 2007
  • 기술의 발전으로 인하여, 대용량의 음악 데이터들을 저장하고 검색하는 것이 중요하게 되었다. 그러나 음악데이터들을 손쉽게 분류하고 검색하기 위한 방법론에 대한 집중적인 연구는 이루어 지지 않고 있다. 본 논문에서는 내용기반의 음악 분류/검색에 대한 새로운 방법론을 제안한다. 기존의 분류화 (classification) 방법들이 음악파일 전체에 대해서 수행하는데 비해 음악파일의 부분만을 분석하여 비슷한 성능을 낼 수 있다는 것을 보여 주었고, 소리의 톤(tone) 표현에 기반한 새로운 피쳐를 제안하여 기존의 피쳐들에 비해 효과적으로 분류를 할 수 있다는 것을 보여주었다. 또한 속도향상을 위한 여러가지 방법론들을 적용하여 실 제품 적용 시 보다 효과적인 방법론이 될 수 있음을 보여주었다. 제안한 방법론을 MuSE (Music Search/Classification Engine)엔진으로 구현함으로써 PC와 PDA상에서 잘 동작함을 보여주었다.

  • PDF