• Title/Summary/Keyword: Park Movement

검색결과 2,791건 처리시간 0.03초

지지면 간격변화에 따른 푸시업(Push-up) 굽힘동작과 푸시업 플러스(Push-up plus) 동작시 상지 근육의활성도 비교 (Comparative Studies of Muscle Activity on Upper Extremity Between Push-up bend and Push-up plus Movement According to change of supporting base interval)

  • 김은영;박흥기;안병헌
    • 대한물리치료과학회지
    • /
    • 제15권3호
    • /
    • pp.31-41
    • /
    • 2008
  • Purpose : The purpose of this study is to examine the muscle activity of shoulder stabilization according to change of supporting base interval between push-up bend and push-up plus position and is to prevent or treat a shoulder injury by the most effective exercise for rehabilitation. Methods : This study analyzed the muscle activity according to change of supporting base interval between push-up bend and push-up plus movement. The participants without neuromuscular disease were 25 students - 12 males and 13 females - all twenty or over and the surface electrode of EMG attached on pectoralis major, triceps long head, middle trapezius, lower trapezius, serratus anterior and latissimus dorsi. The process has practiced 3 sessions of supporting base interval - narrowing interval, two shoulder interval, broad interval - by push-up bend and push-up plus movement. Result : 1. The muscle activity of pectoralis major was significantly increased according to narrow interval of supporting base on push-up plus movement and was significant difference(p<.05). 2. The muscle activity of biceps was significantly increased according to narrow interval of supporting base on push-up bend movement(p<.05). 3. The muscle activity of middle or lower trapezius was a difference according to change of supporting base on push-up bend and push-up plus movement but was not significant difference. 4. The muscle activity of serratus anterior was significantly increased according to broad interval of supporting base on push-up bend movement(p<.05). 5. The muscle activity of latissimus dorsi was significantly increased according to broad interval of supporting base on push-up bend movement(p<.05). Conclusion : These results lead us to the conclusion that push-up bend exercise have the effect of muscle strength of biceps on narrowing interval, of serratus anterior or latissimus dorsi on broad interval and push-up plus exercise have the effect of muscle strength of pectoralis major on narrowing interval of support base.

  • PDF

스마트폰 기반의 사용자 이동상태 판별 알고리즘 (Smart-Phone based User Movement State Identification Algorithm)

  • 하동수;박성준
    • 한국컴퓨터정보학회논문지
    • /
    • 제16권3호
    • /
    • pp.167-174
    • /
    • 2011
  • 본 논문에서는 스마트폰 기반의 사용자 이동 상태 판별 알고리즘에 대해 제안한다. 제안된 알고리즘은 스마트 폰의 자체 내장된 방향 센서와 GPS센서의 데이터 정보를 기반으로 하여 현재 사용자의 이동 수단 및 위치를 판단한다. GPS 센서를 이용해 위치와 이동속도를 계산하여 이동수단을 판별하고, 방향 센서의 데이터를 분석하여 세부적인 이동형태를 판별한다. 본 논문에서는 스마트폰의 두 가지 응용 센서를 이용하여 사용자 이동상태 판별 알고리즘을 구현하고 테스트를 수행하였다. 실험 내용은 GPS를 통해 받은 데이터를 이용하여 이동속도를 계산하고 방향 센서의 변화 폭을 측정 이동형태를 판별할 수 있는 속도와 방향센서의 임계 값를 실험 데이터를 바탕으로 정의하였다. 실험결과 본 논문에서 제안하는 사용자 이동상태 판별 알고리즘을 이용하여 사용자의 이동 상태를 판별 할 수 있었다.

주기성 사지운동증의 운동간격이 수면구조에 미치는 영향 (Effects of Movement Intervals on Sleep Architecture in Subjects with Periodic Limb Movements during Sleep)

  • 손창호;이명희;박두흠;정도언
    • 수면정신생리
    • /
    • 제4권2호
    • /
    • pp.191-200
    • /
    • 1997
  • Objectives : Periodic limb movements during sleep (PLMS) may cause arousals that may lead to non-restorative sleep. PLMS is characterized by long sleep latency, sleep fragmentation, frequent stage shifts, and rarity of stages 3/4 NREM sleep on polysomnography. However, controversies have existed and it still remains to be elaborated whether PLMS actually causes insomnia, since normal persons happen to have PLMS. Clinically, it would be crucial to know factors which might disturb sleep in PLMS. We became interested in Coleman's theory(1980) that invariant periodic movements disturb patients' sleep less. Though, Coleman's study seems to have been confounded by including PLMS patients with various co-morbid sleep disorders. Therefore, we attempted to study in patients only with PLMS the effects of movement patterns on sleep architecture. Methods : In 27 patients diagnosed as having PLMS only with clinical interview and nocturnal polysomnography, we studied the relationship between the movement patterns such as mean duration and variability of periodic limb movement's interval and the sleep architecture variables. Results : The shorter and the more regular the limb movement intervals were, the fewer arousals followed. The movement intervals of the older patients were shorter and more regular than the younger patients. The probability of the accompanying arousal with each limb movement increased as the duration and variance of the movement intervals increased. It decreased as the age and the frequency of limb movements increased. Among these factors the most significant one was the mean duration of the movement intervals. In other words, the shorter the movement intervals were, the less disturbed sleep was. Conclusion : PLMS frequency increases with aging but the probability of the accompanying arousal with each movement decreases with aging. Sleep-disturbing effects of PLMS depends more on the duration and variability of movement intervals than the PLMS frequency.

  • PDF

관성측정장치를 이용한 동태손상증후군의 평가 가능성에 관한 고찰 (Feasibility on Evaluation of Movement System Impairment Syndromes by MEMS-IMU)

  • 김현호;김정균;서재호;박영재;박영배
    • 대한한의진단학회지
    • /
    • 제15권3호
    • /
    • pp.223-234
    • /
    • 2011
  • Objectives: This study shows feasibility and suitability of a microelectromechanical system inertial measurement unit(MEMS-IMU) as a helpful measurement device for evaluating movement system impairment syndrome. Methods: We reviewed articles of two fields in this study. First, we reviewed articles about movement system impairment syndrome(MSIS) as a brand new viewpoint of diagnosing and treating musculoskeletal pain. Second, we reviewed articles about conventional motion analysis system and inertial measurement unit(IMU) to show the superiority of IMU in analyzing the human movement. All papers were searched by SciVerse, world largest search engine and database about many academic fields including engineering and medicine. Results: Some physical quantities of human motions can be useful to the diagnosis of MSIS, and those data can be obtained by the MEMS-IMU without the weak points of the conventional motion analysis systems. Conclusions: Using MEMS-IMU as a measurement unit for diagnosing and evaluating MSIS is feasible and can be extended to many further studies.

방사선 치료시 배경분리알고리즘을 이용한 비젼모니터링 시스템에 대한 연구 (Studies of vision monitoring system using a background separation algorithm during radiotherapy)

  • 박기용;최재현;박제원
    • 한국정보통신학회논문지
    • /
    • 제20권2호
    • /
    • pp.359-366
    • /
    • 2016
  • 방사선 치료에 있어서 정상 조직에는 방사선을 최소화 하고 종양 부위에 정확한 방사선을 집중해서 조사하여 국소 종양 제어율(Local Tumor Rate)을 극대화 하는 것이 가장 중요하다. 이를 위해서 초기에는 치료사들이 직접 환자의 움직임을 감지했으나 정확도가 떨어지고 치료사들의 피로가 가중되는 문제점들이 있었다. 또한 웹카메라를 이용하여 기준영상과 갱신되는 영상의 차분값을 계산하여 그 결과가 기준값을 초과하면 움직임이 발생한 것으로 판단하는 시스템을 사용하였다. 그러나 이 시스템은 환자의 움직임을 정량적으로 분석할 수 없고 토모치료기의 치료베드 이동시 변화되는 배경을 환자와 가려낼 수 없었다. 이에 본 논문에서는 이러한 한계점을 해결하고자 지수가중치(${\alpha}$) 필터를 이용하여 환자의 움직임을 정량화 하고 환자와 치료환경의 배경이미지를 분리하여 치료중 환자의 움직임만을 감지하여 환자의 움직임으로 인한 문제를 줄일 수 있었다.

Discontinuity in GNSS Coordinate Time Series due to Equipment Replacement

  • Sohn, Dong-Hyo;Choi, Byung-Kyu;Kim, Hyunho;Yoon, Hasu;Park, Sul Gee;Park, Sang-Hyun
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권4호
    • /
    • pp.287-295
    • /
    • 2022
  • The GNSS coordinate time series is used as important data for geophysical analysis such as terrestrial reference frame establishment, crustal deformation, Earth orientation parameter estimation, etc. However, various factors may cause discontinuity in the coordinate time series, which may lead to errors in the interpretation. In this paper, we describe the discontinuity in the coordinate time series due to the equipment replacement for domestic GNSS stations and discuss the change in movement magnitude and velocity vector difference in each direction before and after discontinuity correction. To do this, we used three years (2017-2019) of data from 40 GNSS stations. The average magnitude of the velocity vector in the north-south, east-west, and vertical directions before correction is -12.9±1.5, 28.0±1.9, and 4.2±7.6 mm/yr, respectively. After correction, the average moving speed in each direction was -13.0±1.0, 28.2±0.8, and 0.7±2.1 mm/yr, respectively. The average magnitudes of the horizontal GNSS velocity vectors before and after discontinuous correction was similar, but the deviation in movement size of stations decreased after correction. After equipment replacement, the change in the vertical movement occurred more than the horizontal movement variation. Moreover, the change in the magnitude of movement in each direction may also cause a change in the velocity vector, which may lead to errors in geophysical analysis.

복합운동 기능장애로 인한 요통의 수정된 SNAGs (Modified Sustained Natural Apophyseal Glides of Back Pain due to Combined Movement Dysfunction)

  • 박지환
    • 대한정형도수물리치료학회지
    • /
    • 제8권1호
    • /
    • pp.25-30
    • /
    • 2002
  • The main purpose of this article is to suggest a modified SNAGs manual method in based of Mulligan techniques. And this study aimed to resolve the back pain which has combined movement dysfunction in lumbar spine, in addition to upgrade of manual therapy technique in clinical field. The results of this study were as following; 1. The first introduction of SNAGs in Korea is the 'International Mulligan Concepts and Techniques Seminar' by Prof. Russell M. Woodman(Quinnipiac college, USA), 1998. SNAGs is defined a mobilization with movement manual therapy that facet joints of the lesion mobilized to anterior-superior direction according to the treatment plane in apophyseal joint of hypomobility. 2. A treatment mechanism of the SNAGs is, Mulligan say, HIVD which is the result of posterior disk bulging from a increased between intervertebral pressure due to hypo-mobile of facet joints in abnormal spine, so therapist should be necessary mobilization of zygophyseal joints especially in disk lesion. 3. Because Mulligan does not yet mentioned SNAGs techniques about a back pain with combined movements dysfunction, so we suggest a modified SNAGs method for manual therapy of back pain patients due to combined movement dysfunction at lumbar.

  • PDF

안구운동 분석을 통한 의복의 시각적 평가의 객관화 (Methodology Development of Clothing Appearance by Eye Movement Analysis)

  • 박혜준
    • 한국의류학회지
    • /
    • 제30권6호
    • /
    • pp.992-1000
    • /
    • 2006
  • The main purpose of this research is to develop the methodology of objective evaluation of clothing appearance by eye movement analysis. The visual clothing items used in this study were skirt, one-piece, pants and shirt with the style variation of silhouette and details. By observing eye movement during visual evaluation of clothing, we can achieve the basic fixation data of eye movement. Moreover, we developed the Matlab program to extract the fixation coordinate and number of eye fixation on each part of the clothing item. As results, there were differences in the duration of fixation time for each item and the fixation time was not different by styles within a clothing item. However, we could find differences in the fixation time within a style, in other words, we could select the important parts of the clothing by observing the fixation time in a certain clothing item. It is also noted that time required in visual information processing differs depending on the item, and there was a region which contain more information independent with styles in the same item. By developing the objective method of visual evaluation that correspond to human's visual information processing, the results are expected to be applied in the retrieval program in internet shopping mall or in the development of contents for advertisement of clothing.

인체의 동작의도 판별을 위한 퍼지 C-평균 클러스터링 기반의 근전도 신호처리 알고리즘 (Movement Intention Detection of Human Body Based on Electromyographic Signal Analysis Using Fuzzy C-Means Clustering Algorithm)

  • 박기원;황건용
    • 한국멀티미디어학회논문지
    • /
    • 제19권1호
    • /
    • pp.68-79
    • /
    • 2016
  • Electromyographic (EMG) signals have been widely used as motion commands of prosthetic arms. Although EMG signals contain meaningful information including the movement intentions of human body, it is difficult to predict the subject's motion by analyzing EMG signals in real-time due to the difficulties in extracting motion information from the signals including a lot of noises inherently. In this paper, four Ag/AgCl electrodes are placed on the surface of the subject's major muscles which are in charge of four upper arm movements (wrist flexion, wrist extension, ulnar deviation, finger flexion) to measure EMG signals corresponding to the movements. The measured signals are sampled using DAQ module and clustered sequentially. The Fuzzy C-Means (FCMs) method calculates the center values of the clustered data group. The fuzzy system designed to detect the upper arm movement intention utilizing the center values as input signals shows about 90% success in classifying the movement intentions.

Constraint Operator for the Kinematic Calibration of a Parallel Mechanism

  • Lee, Min-Ki;Kim, Tae-Sung;Park, Kun-Woo;Kwon, Sung-Ha
    • Journal of Mechanical Science and Technology
    • /
    • 제17권1호
    • /
    • pp.23-31
    • /
    • 2003
  • This paper introduces a constraint operator for the kinematic calibration of a parallel mechanism. By adopting the concept of a constraint operator, the movement between two poses is constrained. When the constrained movements are satisfied, the active joint displacements are taken and inputted into the kinematic model to compute the theoretical movements. A cost function is derived by the errors between the theoretical movement and the actual movement. The parameters that minimize the cost function are estimated and substituted into the kinematic model for a kinematic calibration. A single constraint plane is employed as a mechanical fixture to constrain the movement, and three digital indicators are used as the sensing devices to determine whether the constrained movement is satisfied. This calibration system represents an effective, low cost and feasible technique for a parallel mechanism. A calibration algorithm is developed with a constraint operator and implemented on a parallel manipulator constructed for a machining center tool.