• 제목/요약/키워드: Park Kyung-ni

Search Result 188, Processing Time 0.023 seconds

A STUDY ON SURFACE ROUGHNESS OF METALS ACCORDING TO FINISHING AND POLISHING PROCEDURES - AN ATOMIC FORCE MICROSCOPE ANALYSIS - (연마방법에 따른 금속의 활택도에 관한 연구 - Atomic Force Microscope를 이용한 -)

  • Park Won-Kyu;Woo Yi-Hyung;Choi Boo-Byung;Lee Sung-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.1
    • /
    • pp.1-19
    • /
    • 2003
  • The surface of metals should be as smooth as possible for optimum comfort, oral hygiene, low plaque retention, and resistance to corrosion. In this study five specimens of each precious metal(type III gold alloy, ceramic gold alloy, and Ag-Pd alloy) were divided into five groups according to finishing and polishing procedures : group 1(sandblaster), group 2(group 1+stone), group 3(group 2+brown rubber), group 4(group 3+green rubber), and group 5(group 4+rouge). Six specimens of each non-precious metal(Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy) were divided into six groups: group 1(sandblaster), group 2(group 1+hard stone), group 3(group 2+electrolytic polisher), group 4(group 3+brown hard rubber point), group 5(group 4+green hard rubber point), and group 6(group 5+rouge). Considering factors affecting the rate of abrasion, the same dentist applied each finishing and polishing procedure. In addition, the surface roughness of enamel, resin, and porcelain was evaluated. The effect of finishing and polishing procedures on surface roughness of precious and non-precious metals, enamel, resin, and porcelain was evaluated by means of Atomic Force Microscope(AutoProbe CP. Park Scientific Instruments, U.S.A.) that can image the three dimensional surface profile and measure average surface roughness values of each sample at the same time. The obtained results were as follows : 1. According to finishing and polishing procedures, the surface roughness of type III gold alloy, ceramic gold alloy, and Ag-Pd alloy was decreased in the order of group 1, 2, 3, 4, and 5 (P<0.01). 2. According to finishing and polishing procedures. the surface roughness of Co-Cr alloy, Ni-Cr alloy, and Co-Cr-Ti alloy was decreased in the order of group 1, 2, 3, 4, 5, and 6 (p<0.01). 3. There was not statistically significant difference in the surface roughness among three metals of precious metals in group 1 but was significant difference in group 2, 3, 4, and 5 (P<0.05). 4. There was not statistically significant difference in the surface roughness among three metals of non-precious metals in all groups. 5. When the surface roughness of the smoothest surface of each metal, enamel. porcelain, and resin was compared, porcelain was the smoothest and the surface roughness was decreased in the order of Ni-Cr alloy. Co-Cr alloy. Co-Cr-Ti alloy, resin. Ag-Pd alloy, ceramic gold alloy type III gold alloy, and enamel (P<0.01). The results of this study indicate that the finishing and polishing procedures should be carried out in a logical, systematic sequence of steps and the harder non-precious metals may be less resistance to abrasion than are the softer precious metals.

Evaluation of Texture and Mechanical Property on Annealing Condition of Ni-Plated Hybrid Cu Sheet (어닐링처리에 따른 니켈 도금한 하이브리드 동판의 집합조직 및 기계적 특성평가)

  • Lee, Jung-Il;Lee, Joo-Ho;Cho, Kyung-Won;Kim, Kun-Nam;Kim, Gang-Beom;Jang, Tae-Soon;Park, No-Jin
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.21 no.3
    • /
    • pp.144-149
    • /
    • 2008
  • It has been reported that copper and copper alloys have a large anisotropy of functional properties such as electrical, thermal and mechanical properties, which means that the texture of polycrystalline alloy should be considered to achieve better properties. In this study, the determination of grain growth orientation and texture formation in the cold-rolled, heat-treated and Ni-plated hybrid copper sheets was investigated. Grain growth direction and texture formation were analyzed by the X-ray pole figure. The influence of texture on the mechanical properties could be quantitatively confirmed by the results from the orientation distribution function and the tensile test. The heat-treated texture in the cold-rolled hybrid copper sheet is also investigated and discussed.

Fabrication and characteristic of metal insertedteflon diaphragm piezoeletric device module using quartz crystal oscillator (수정진동자를 이용한 메탈 삽입 테프론 다이어프램 압전소자모듈의제조 및 특성)

  • Kim, Kyung-Min;Park, Sung-Hyun;Kim, Sung-Woo;Son, Won-Geon;Shin, Byoung-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.149-154
    • /
    • 2010
  • Top of the alumina body which is made according to plan has been printed using a screen printer equipment in order to print an electrode pattern. The electrode is connected with the quartz crystal oscillator of the piezoelectricity method which has a piezoelectric characteristic. The pressure contact department has been experimented using three type of the teflon. The teflon is good for pressure delivery vector but it is bad restitution. So we devised the structure which inserts the metal in the teflon. Bottom of the module is connected with the signal processing department which is planned in advance and then has investigated to characteristic. Therefore we have got the best output-voltage and frequency characteristic follows in the pressure.

Volumetric Thermal Analysis of Hydrogen Desorption from Mg-13.5wt%Ni Hydride (Mg-13.5wt%Ni 합금 수소화합물의 수소방출에 대한 부피법에 의한 열분석)

  • HAN, JEONG SEB;PARK, KYUNG DUCK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.26 no.4
    • /
    • pp.308-317
    • /
    • 2015
  • To investigate the effect of microstructure on the formation of the desorption peak, the volumetric thermal analysis technique (VTA) was applied to the Mg-13.5 wt% Ni hydride system. The sample made by the HCS (hydriding combustion synthesis) process had two kinds of Mg microstructures. Linear heating was started with various constant heating rates. Only one peak was appeared in the case of the small initial hydrogen wt% (0.83 wt%). Yet, two peaks were appeared with increasing initial hydrogen wt% (1.85 and 3.73 wt%) when only Mg was hydrogenated. The first peak was formed through the evolution of hydrogen from $MgH_2$, made by eutectic Mg. The second peak was formed through the evolution of hydrogen from $MgH_2$, made by primary Mg. Therefore, this result shows that the microstructure also has a considerable effect on forming the desorption peak. We have also derived the hydrogen desorption equations by VTA to get apparent activation energy when the rate-controlling step for the desorption of the hydrided system is the diffusion of hydrogen through the ${\alpha}$ phase and the chemical reaction ${\beta}{\rightarrow}{\alpha}$.

LIFETIME AND FRACTURE PATTERNS OF NITI ROTARY FILES IN MOLARS (대구치에서 회전식 NiTi file의 수명과 파절양상)

  • Kim, Jin-Woo;Ahn, Byung-Doo;Park, Se-Hee;Shin, Hye-Jin;Cho, Kyung-Mo
    • Restorative Dentistry and Endodontics
    • /
    • v.30 no.3
    • /
    • pp.184-192
    • /
    • 2005
  • Intracanal separation of the rotary files is a serious concern in modern endodontic practice. The objective of this study was to compare the life span and fracture patterns of three NiTi rotary files in molar teeth Mesiobuccal roots of upper molar (n = 150) and mesial roots of lower molar (n = 150) were divided into three groups and each group was prepared with Profile, ProTaper, and K3 respectively. Every file was used until separation and/or deterioration of the cutting blade was happened, and then the number of canals to separation and/or unwinding were recorded. Radiographs and Scanning electon microscope (SEM) photographs were taken to evaluate the patterns of separation. The results were as follows: 1. There were no significant differences in numbers of canals to separation and/or unwinding among the groups. 2. Comparing between flaring files, K3 showed significant lower numbers of canals to separation and/or unwinding (p < 0.05), and there was no significant difference between shaping files 3. Separations of instruments were occurred at the midpoint of curvatures within the canals 4. In SEM observations, ductile fractures were seen in most of cases, characterized by shallow dimples. Additional researches is needed to provide a new guideline that informs the appropriate number of times to use NiTi files.

Efficacy of retreatment NiTi files for root canals filled with calcium silicate-based sealer (칼슘실리케이트 계열 실러로 충전한 근관에서 재치료용 NiTi 파일의 효율성)

  • Jae-Yun, Hyun;Kyung-Mo, Cho;Se-Hee, Park;Yoon, Lee;Yoon-Joo, Lee;Jin-Woo, Kim
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.4
    • /
    • pp.213-221
    • /
    • 2022
  • Purpose: The efficacy of the amount of sealer in the root canal and two retreatment NiTi file systems in removing filling materials. Materials and Methods: Extracted premolars with a single root canal were selected for this study. After access opening and root canal preparation up to size #40/.06, the specimens were randomly divided into four groups. Gutta percha (GP) tapers of .06 or .04 were used for each group and filled using a single-cone filling technique with CeraSeal, a calcium silicate-based sealer. Each group was retreated either using the ProTaper Universal Retreatment System (PTUR) or the Hyflex Remover (HR). The time taken to remove the filling material, the amounts of apically extruded debris, and canal cleanliness were measured and compared. Results: The amount of sealer did not affect the efficiency when removing the filling materials. However, the filling material was removed faster in the HR group than in the PTUR group. Two types of NiTi files showed similar retreatment effects in the amounts of apically extruded debris and in the degree of canal cleanliness. Conclusion: The amount of sealer in canal filling had no significant effect on retreatability. Retreatment with HR removed filling materials is faster than PTUR. There was no difference in other removal efficiencies according to the type of retreatment NiTi file.

Evaluations of corrosion resistance of Ni-Cr plated and Zn-plated Fe Substrates Using an Electrolytic Corrosion Test (전해부식시험을 이용한 니켈-크롬도금강판 및 아연도금강판의 내식성 비교평가시험)

  • Lee, Jae-Bong;Kim, Kyung-Wook;Park, Min-Woo;Song, Tae-Jun;Lee, Chae-Seung;Lee, Eui-Jong;Kim, Sang-Yeol
    • Corrosion Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.56-64
    • /
    • 2013
  • An Eectrolytic Corrosion(EC) test method was evaluated by the comparison with Copper Accelerated Acetic Salt Spray(CASS) and Neutral Salt Spray(SS) tests. Those methods were applied in order to evaluate corrosion resistance of Ni-Cr plated and Zn-plated Fe substrates. The correlations between results obtained by different test methods were investigated. Results showed that the electrochemical method such as the EC test method was superior to the conventional methods such as CASS and SS, in terms of the quantitative accuracy and the test-time span. Furthermore, the EC test method provided the useful means to estimate the initiation of corrosion of each layer by monitoring the rest potentials of the coated layers such as Ni, Cr, and Zn on Fe substrate. With regard to test time spans, the EC test provided the 78 times and 182 times faster results than the CASS test in cases of $Fe+5{\mu}m$ $Ni+0.5{\mu}m$ Cr and $Fe+20{\mu}m$ $Ni+0.5{\mu}m$ Cr respectively, while the EC test was 85 times faster results than the Salt Spray test in the case of $Fe+20g/m^2$ Zn. Therefore, the EC test can be the better method to evaluate the resistance to corrosion of coated layers than the conventional methods such as the SS test and the CASS.

A Study on the Preparation of Rare Earth Oxide Powder for Rare Earth Precipitates Recovered from Spent Ni-MH Batteries (폐니켈수소전지로부터 회수된 희토류 침전물의 희토류 산화물 분말 제조에 대한 연구)

  • Kim, Dae-Weon;Ahn, Nak-Kyoon;Shim, Hyun-Woo;Park, Kyung-Soo;Choi, Hee-Lack
    • Journal of Powder Materials
    • /
    • v.25 no.3
    • /
    • pp.213-219
    • /
    • 2018
  • We report a method for preparing rare earth oxides ($Re_xO_y$) from the recycling process for spent Ni-metal hydride (Ni-MH) batteries. This process first involves a leaching of spent Ni-MH powders with sulfuric acid at $90^{\circ}C$, resulting in rare earth precipitates (i.e., $NaRE(SO_4)_2{\cdot}H_2O$, RE = La, Ce, Nd), which are converted into rare earth oxides via two different approaches: i) simple heat treatment in air, and ii) metathesis reaction with NaOH at $70^{\circ}C$. Not only the morphological features but also the crystallographic structures of all products are systematically investigated using field-emission scanning electron microscopy (FESEM) and X-ray diffraction (XRD); their thermal behaviors are also analyzed. In particular, XRD results show that some of the rare earth precipitates are converted into oxide form (such as $La_2O_3$, $Ce_2O_3$, and $Nd_2O_3$) with heat treatment at $1200^{\circ}C$; however, secondary peaks are also observed. On the other hand, rare earth oxides, RExOy can be successfully obtained after metathesis of rare earth precipitates, followed by heat treatment at $1000^{\circ}C$ in air, along with a change of crystallographic structures, i.e., $NaRE(SO_4)_2{\cdot}H_2O{\rightarrow}RE(OH)_3{\rightarrow}RE_xO_y$.

The Efficiency of the Ni-Ti Rotary Files in Curved Simulated Canals Shaped by Novice Operators (만곡모형근관에서 초심자가 근관형성시 Ni-Ti 전동파일의 효용성)

  • Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.2
    • /
    • pp.146-155
    • /
    • 2003
  • 여러 가지 장점으로 인해 Ni-Ti 전동 파일을 근관성형에 사용하는 빈도가 점차 증가되는 추세이지만, 초심자를 대상으로 한 연구는 부족한 실정이다. 이에 본 연구에서는 초심자에서 Ni-Ti 전동 파일을 사용할 때 근관 형성의 효용성을 평가하고, 어떤 방법이 초심자에게 적절한지를 알아보고자 하였다. 근관형태가 재현된 레진 블록을 이용하여 12명의 초심자와 4명의 숙련자가 근관 형성을 시행하였다. 각 술자는 ProFile, ProTaper, Hybrid (ProFile+ProTaper)를 이용하여 각각의 레진 블록을 세 개씩 근관형성하고, 각 파일 별의 근관 형성 시간을 기록하였다. 근관 형성 전과 후의 digital 이미지를 중첩하여 치근단으로부터 1, 2, 3, 4, 5, 6, 7mm level에서 근관단면의 총길이 변화량, 만곡 외측의 길이 변화량, 만곡 내측의 길이 변화량, 중심이동량, 중심이동율과 치근단에서의 apical transportation을 구하고, 초심자와 숙련자 사이의 차이를 비교 평가하였다. 실험결과 ProFile군의 1, 3, 5, 6, 7mm level과 ProTaper군의 6mm level, Hybrid군의 3mm level에서 초심자의 근관단면의 총길이 변화량이 숙련자보다 많았다. 모든 군에서 치근단으로부터 4, 5, 6, 7mm level에서는 근관 중심이 만곡내측으로 이동하였고, 1 2, 3mm level 에서는 만곡외측으로 이동하였으나, 숙련자가 시행한 Hybrid군의 3mm level과 비숙련자가 시행한 ProTaper 군의 3mm level에서는 만곡내측으로 이동하였다. 모든 군의 3mm level과 ProFile 군의 5mm level에서 초심자의 중심이동율이 숙련자에 비해 컸으며, 초심자가 ProTaper를 사용시 더 큰 apical trans portation을 보였고, 모든 군에서 초심자가 근관형성시 더 많은 시간이 걸렸다. ProFile과 ProTaper를 이용한 Hybrid technique이 초심자에게 추천되며, 초심자들도 충분히 교육받는다면 만곡된 근관의 근관형성에 있어서 Ni-Ti rotary file의 이용이 가능하리라고 사료된다.

Evaluation on Thermal Shock Damage of Smart Composite using Nondestructive Technique (비파괴 기법을 이용한 스마트 복합재료의 열충격손상평가)

  • Lee, Jin-Kyung;Park, Young-Chul;Lee, Kyu-Chang;Lee, Joon-Hyun
    • Composites Research
    • /
    • v.20 no.3
    • /
    • pp.37-42
    • /
    • 2007
  • Tensile residual stress is occurred by difference of coefficients of thermal expansion between fiber and matrix is one of the serious problems in metal matrix composite(MMC). TiNi alloy fiber was used to solve the problem of the tensile residual stress as the reinforced material. TiNi alloy fiber improves the tensile strength of composite with occurring of compressive residual stress in the matrix by its shape memory effect. A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding effect of the matrix and the reinforcement within the SMA composite by the hot press method was strengthened by cold rolling. In addition, acoustic emission technique was used to quantify the microscopic damage behavior of cold rolled TiNi/A16061 shape memory alloy composite at low temperature. The damage degree for the specimen that underwent thermal shock cycles was also discussed.