• Title/Summary/Keyword: Park Disk

Search Result 1,035, Processing Time 0.036 seconds

Head Slider Design Using Approximation Method For Load/Unload Applications (근사화 기법을 이용한 Load/Unload 용 헤드 슬라이더 최적설계)

  • Son, Seok-Ho;Yoon, Sang-Joon;Park, No-Cheol;Park, Young-Pil;Choi, Dong-Hoon
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.3
    • /
    • pp.169-177
    • /
    • 2006
  • In this study, we present the optimization of a head slider using kriging method in order to reduce lift-off force during unloading process with satisfying reliable flying attitude in steady state. To perform an optimization process efficiently, a simplified lift-off force model, which is a function of air bearing suction force and flying attitudes, is created by kriging method. The EMDIOS, which is the process integration and design optimization software developed by iDOT, is used to automatically wrap the analysis with the optimization and efficiently implements the repetitive works between analyzer and optimizer. An optimization problem is formulated to reduce the lift-off force during unloading process while satisfying the flying attitude in reliable range over the entire recording band and reducing the probability of contact between slider and disk. The simulation result shows that the amplitude of lift-off force of optimized L/UL slider is reduced about 62%, compared with that of initial slider model. It is demonstrated by the dynamics L/UL simulation that the optimum slider incorporated with the suspension is not only smoothly loaded onto disk but also properly unloaded onto the ramp.

  • PDF

Design Variables of Chemical-Mechanical Polishing Conditioning System to Improve Pad Wear Uniformity (패드 마모 균일성 향상을 위한 CMP 컨디셔닝 시스템 설계 변수 연구)

  • Park, Byeonghun;Park, Boumyoung;Jeon, Unchan;Lee, Hyunseop
    • Tribology and Lubricants
    • /
    • v.38 no.1
    • /
    • pp.1-7
    • /
    • 2022
  • Chemical-mechanical polishing (CMP) process is a semiconductor process that planarizes a wafer surface using mechanical friction between a polishing pad and a substrate surface during a specific chemical reaction. During the CMP process, polishing pad conditioning is applied to prevent the rapid degradation of the polishing quality caused by polishing pad glazing through repeated material removal processes. However, during the conditioning process, uneven wear on the polishing pad is inevitable because the disk on which diamond particles are electrodeposited is used. Therefore, the abrasion of the polishing pad should be considered not only for the variables during the conditioning process but also when designing the CMP conditioning system. In this study, three design variables of the conditioning system were analyzed, and the effect on the pad wear profile during conditioning was investigated. The three design variables considered in this study were the length of the conditioner arm, diameter of the conditioner disk, and distance between centers. The Taguchi method was used for the experimental design. The effect of the three design variables on pad wear and uniformity was assessed, and new variables used in conditioning system design were proposed.

Evaluation of 226Ra analysis methods using a gamma-ray spectrometer and a liquid scintillation counter (감마선분광분석기와 액체섬광계수기를 이용한 226Ra 분석법 비교 연구)

  • Ju, Byoung Kyu;Kim, Moon Su;Kim, Hyun Koo;Kim, Dong Su;Cho, Sung Jin;Yang, Jae Ha;Park, Sun Hwa;Kim, Hyoung Seop;Kwon, Oh Sang;Kim, Tae Seung
    • Analytical Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.228-235
    • /
    • 2015
  • The efficiency and applicability of the solid phase extraction disk method in a 226Ra analysis were examined by the gamma ray spectrometer (GRS) method using a Marinelli beaker and the liquid scintillation counter (LSC) method for groundwater. The recovered 226Ra, which was filtered by the solid phase extraction disk, was analyzed using gamma ray spectrometer The disks, which were pretreated for caulking the daughter nuclide, were sealed with polyethylene film. Distilled water was used for the blank value of the 226Ra activity. The recovery values of 214Bi and 214Pb in the solid phase extraction disk, which used 226Ra standard material, were 80% (295.21 Kev) and 104% (351.92 Kev), respectively, which were higher than 75% determined by the LSC. The injection of nitrogen gas into the measuring chamber reduced the interference values by about 10%. The detection limits of the 226Ra activity in a blank sample of 5 L were 0.17~0.40 pCi/L after 80,000 seconds of measuring time. The relationship of the 226Ra activity in the solid phase extraction disk method and in the LSC method in seven groundwater samples showed a correlation coefficient value 0.987, which implies the applicability of the solid phase extraction disk method. The results showed that 226Ra activity in groundwater using the solid phase extraction disk method has the following benefits: simple pretreatment, time saving, high recovery values, a low detection limit, and so on. Compared with the LSC method and the GRS method using the Marinelli beaker for the 226Ra analysis, the solid phase extraction disk method could be useful in groundwater samples with low levels of activities of radionuclides because the method is not restricted by the volume of the sample.

Performance of a Group Candle Filter in a Hot Bench Unit

  • Park, Joo-Hong;Park, Gyung-Won
    • Journal of Energy Engineering
    • /
    • v.8 no.1
    • /
    • pp.143-149
    • /
    • 1999
  • The mounting technology of ceramic candle elements utilizing disk spring was tested in a hot bench unit. Seven SiC candle elements were fixed in three groups by 2, 2, and 3 elements per group. And its performance was investigated in a hot gas stream using oil burned-exhaust gas. The experimental results showed that this mounting method gave a good performance enough to be useful for the particulate removal in the integrated gasification combined cycle (IGCC). Some operational characteristics of the groupfilter were observed.

  • PDF

Analysis of Characteristics of Optical Pickup Actuator for Tilt Control (틸트제어를 위한 광픽업 구동기의 특성 분석에 관한 연구)

  • Kim, Chul-Jin;Lee, Kyung-Taek;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.11a
    • /
    • pp.377.2-377
    • /
    • 2002
  • In optical disk drives (ODD), the demands of high data density and high speed have been increasing rapidly to achieve high data capacity and data transfer rate The use of short wavelength laser and high track following performance are needed to raise data density and data rate. For high-performance actuator, the improvement of linearity and acceleration become more important. (omitted)

  • PDF

Design and Implementation of Unified Index for Moving Objects Databases (이동체 데이타베이스를 위한 통합 색인의 설계 및 구현)

  • Park Jae-Kwan;An Kyung-Hwan;Jung Ji-Won;Hong Bong-Hee
    • Journal of KIISE:Databases
    • /
    • v.33 no.3
    • /
    • pp.271-281
    • /
    • 2006
  • Recently the need for Location-Based Service (LBS) has increased due to the development and widespread use of the mobile devices (e.g., PDAs, cellular phones, labtop computers, GPS, and RFID etc). The core technology of LBS is a moving-objects database that stores and manages the positions of moving objects. To search for information quickly, the database needs to contain an index that supports both real-time position tracking and management of large numbers of updates. As a result, the index requires a structure operating in the main memory for real-time processing and requires a technique to migrate part of the index from the main memory to disk storage (or from disk storage to the main memory) to manage large volumes of data. To satisfy these requirements, this paper suggests a unified index scheme unifying the main memory and the disk as well as migration policies for migrating part of the index from the memory to the disk during a restriction in memory space. Migration policy determines a group of nodes, called the migration subtree, and migrates the group as a unit to reduce disk I/O. This method takes advantage of bulk operations and dynamic clustering. The unified index is created by applying various migration policies. This paper measures and compares the performance of the migration policies using experimental evaluation.

The Pad Recovery as a function of Diamond Shape on Diamond Disk for Metal CMP (Metal CMP 용 컨디셔너 디스크 표면에 존재하는 다이아몬드의 형상이 미치는 패드 회복력 변화)

  • Kim, Kyu-Chae;Kang, Young-Jae;Yu, Young-Sam;Park, Jin-Goo;Won, Young-Man;Oh, Kwang-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.3 s.40
    • /
    • pp.47-51
    • /
    • 2006
  • Recently, CMP (Chemical Mechanical Polishing) is one of very important processing in semiconductor technology because of large integration and application of design role. CMP is a planarization process of wafer surface using the chemical and mechanical reactions. One of the most important components of the CMP system is the polishing pad. During the CMP process, the pad itself becomes smoother and glazing. Therefore it is necessary to have a pad conditioning process to refresh the pad surface, to remove slurry debris and to supply the fresh slurry on the surface. A conditioning disk is used during the pad conditioning. There are diamonds on the surface of diamond disk to remove slurry debris and to polish pad surface slightly, so density, shape and size of diamond are very important factors. In this study, we characterized diamond disk with 9 kinds of sample.

  • PDF

The Acclerated Life Test of Hard Disk In The Environment of PACS (PACS 환경에서 하드디스크의 가속 수명시험)

  • Cho, Euy-Hyun;Park, Jeong-Kyu;Chae, Jong-Gyu
    • Journal of Digital Contents Society
    • /
    • v.16 no.1
    • /
    • pp.63-70
    • /
    • 2015
  • In this paper, we estimate the life cycle from acceleration life test about the hard disk of disk array of image storage of PACS. Webuil distribution was selected by the Anderson-Darling goodness-of-fit test with data of down time at $50^{\circ}C$ and $60^{\circ}C$. The equality test of shape parameter and scale parameter was conducted, so that the probability distribution estimated from data of down time at $50^{\circ}C$ and $60^{\circ}C$ was not statistically significant. The shape parameter was 1.0409, The characteristic life was 24603.5 hours at normal user condition($30^{\circ}C$) by the analysis of weibull-arrhenius modeling which included the acceleration factor of temperature, and The activation energy was 0.5011 eV through arrhenius modeling. The failure analysis of the failure samples of acceleration test and the samples of market return was conducted, so that the share percentage of failure mode was detail difference but the rank of share percentage was almost same. This study suggest the test procedure of acceleration test of hard disk drive in PACS using environment, and help the life estimation at manufacture and use.

The Effect of Erythrosine-mediated Photodynamic Therapy on Intraorally Formed Biofilm on Titanium Surface

  • Park, Se-Hwan;Lee, Si-Young;Chang, Beom-Seok;Um, Heung-Sik;Lee, Jae-Kwan
    • International Journal of Oral Biology
    • /
    • v.37 no.3
    • /
    • pp.103-108
    • /
    • 2012
  • The purpose of this study was to assess the efficacy of photodynamic therapy (PDT) using erythrosine and a halogen light source to treat a biofilm formed on a machined surface titanium disk in vivo. Ten volunteers carried an acrylic appliance containing six machined surface titanium disks on the upper jaw over a period of five days. After the five days of biofilm formation period, the disks were removed. PDT using 20 ${\mu}M$ erythrosine and halogen light was then applied to the biofilms formed on the disks. Experimental samples were divided into a negative control group (no erythrosine and no irradiation), E0 group (erythrosine 60s + no irradiation), E30 group (erythrosine 60s + halogen light 30s), and E60 group (erythrosine 60s + halogen light 60s). Following PDT, the bacteria in the biofilm were found to be detached from each disk. Each suspension with detached bacteria were diluted and cultivated on a blood-agar plate for five days under anaerobic conditions. The cultivated bacterial counts in the E60 group were significantly lower than the control group (86.4%) or E0 group (76.7%). In the experimental groups also, the light exposure time and bacterial counts showed a negative correlation. In conclusion, PDT using erythrosine and halogen light has bactericidal effects on biofilms formed on a titanium disk in vivo. Notably, applying 20 ${\mu}M$ erythrosine and 60 seconds of halogen light irradiation had a significantly potent effect.

Numerical Modeling of Injection/Compression Molding for Center-gated Center-gated Disk (Part I) (Center-gated 디스크에 대한 사출/압축 성형공정의 수치적 모델링-압축성을 고려한 점탄성유체 모델의 사출성형-)

  • Kim, Ilhwan;Park, Seong-Jin;Chung, Seong-Taek;Kwon, Tai-Hun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.22 no.2
    • /
    • pp.289-301
    • /
    • 1998
  • The present study attempted to numerically simulate the process in detail by developing an appropriate physical modeling and the corresponding numerical analysis for precision injection and injection/compression molding process of center-gated disk. In part I, a physical modeling and associated numerical analysis of injection molding with a compressible viscoelastic fluid model are presented. In the distribution of birefringence, the packing procedure results in the inner peaks in addition to the outer peaks near the mold surface, and values of the inner peaks increase with the packing time. Also, values of the density in the core region increase with the packing time. From the numerical results, we also found that birefringence becomes smaller as the melt temperature gets higher and that it is insignificantly affected by the flow rate and the mold temperature. As far as the density distribution is concerned, mold temperature affected the distribution of density especially near the wall. But it was not significantly affected by flow rate and melt temperature. Numerical results of birefringence coincided with experimental data qualitatively but didn't quantitatively.