• Title/Summary/Keyword: Park Construction Cost

Search Result 1,018, Processing Time 0.026 seconds

A Study on the Limits of Manufacturing Innovation and Policy Direction of SMEs in the 4th Industrial Revolution : Focusing on the Limitations and Examples of Pohang SME's Smart Factory Introduction (4차 산업혁명시대 지역 중소기업의 제조혁신 한계와 스마트공장 정책 방향성 연구: 포항지역 중소기업의 스마트공장 조사를 중심으로)

  • Kim, Eunyoung;Park, Munsu
    • Journal of Science and Technology Studies
    • /
    • v.18 no.2
    • /
    • pp.269-306
    • /
    • 2018
  • Through this study, it is aimed to derive the policy direction considering the characteristics of the present Smart Factory, the industrial condition of Pohang area, and the promotion field. Secondly, the questionnaire data of the regional enterprises will prepare for the improvement of the industrial structure and the implications for efficiency, and preparation for regional preparation and industrial changes in preparation for the next generation of production revolution. The construction of Smart Factory in Pohang can be divided into two major directions. First, it is analyzed that smart factory pilot projects are highly needed, focusing on competitive medical precision manufacturing field among the SMEs in the region, primary metal and nonmetal manufacturing industries, and other machinery fields. In addition, local SMEs are willing to introduce smart factories for reasons of quality improvement and cost reduction, and it is confirmed that they will actively promote employee training and expertise if they can upgrade continuously.

A Study on Optimal Capacity Design of Renewable Combined Power System for Energy Self-Sufficient Island (에너지 자립섬을 위한 신재생복합발전시스템의 최적용량 설계에 관한 연구)

  • Chang, Bong-Chul;Moon, Chae-Joo;Chang, Young-Hak;Park, Tae-Sik;Jeong, Moon-Seon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.11
    • /
    • pp.1271-1276
    • /
    • 2015
  • The recent trend is that diesel power generation on islands where its prime cost for power generation is high is replaced by new and renewable energy. Therefore, south Jeolla province is progressing the construction project of self-sufficient islands for the areas where power is supplied by depending on diesel generators, which is the project that power is supplied through eco-friendly energy source using sunlight, wind power and energy storage device etc. However, it is difficult to construct new and renewable energy source with the capacity to respond to the load perfectly due to its environmental and geographical conditions regarding capacity design of new and renewable energy. Besides, Microgrid design considering appropriate capacity design of the system components and efficient operation is required through the analysis of climate conditions and load patterns from the design stage for optimal composition of a hybrid system with economic feasibility. Therefore, this study is aimed to conduct a research on optimal combination, capacity calculation and economic feasibility by comprising a hybrid power generation system which will replace 40% of power generation by diesel as new and renewable energy source for Geomun Island where has more than 300 households and requires expansion of the facility among islands located in southwest coast.

Research for Network on Medical Association and International Medical Tourism - Based on Centum Medical Partners - (의료협력과 국제 의료관광 네트워크에 관한 연구 - 센텀 메디컬 파트너스를 중심으로 -)

  • Park, Ki-Soo;Bae, Jong-Cheol;Choi, Bong-Joon
    • Journal of Korean Clinical Health Science
    • /
    • v.2 no.1
    • /
    • pp.59-71
    • /
    • 2014
  • Purpose. Medical tourism is recently becoming a new industry with great growth potential. The South Korean government is shifting medical tourism from simple cultural tourism to a high value-added industry with a new paradigm. Methods. The government has been providing positive support and marketing policies since the introduction of the article concerning foreign patient attraction to the medical law in 2009, and various types of medical institutions around the country has participated actively in medical tourism by themselves or in cooperation of government bodies and made increasingly greater performance. Results. This study obtained the following results. The medical institutions in Korea have been making efforts to see more development and profitability in diverse ways, including medical tourism for foreign patients and the advance of the Korean medical institutions into foreign markets. However, many local governing bodies and medical institutions participating in medical tourism around the country have primarily focused on examination and treatment on the basis of foreign patients' visit to South Korea and rarely built a medical network with other countries directly for medical tourism. This study presents a case of building a local medical network and a network for international medical tourism successfully on the basis of the local medical association, CMP, which has been formed naturally in Busan. The success factors for CMP included 1) enthusiasm of the official in charge; 2) the medical level, the service level, and open-mindedness of participant medical institutions; 3) cost efficiency due to executive office management with no costs, no conflicts, and constant partnership; 4) security of non-competitive expertise for participants; 5) local factors of CMP; 6) participation of good agencies; 7) reinforcement of participation networks; and 8) post facto management and local doctor management. Conclusions. Its positive effects included patient introduction and greater profitability on an internal basis as well as construction of the collaboration system with the institutions related to medical tourism and confidence. However, there are some limitations: it is still difficult to predict performance due to the short period of their activities, and it is necessary to continue to observe their constant activities since a single medical association was involved.

Priority Analysis for Infrastructure Recovery from Volcanic Disaster (사회기반시설의 화산재해 복구 우선순위 산정)

  • Park, Hyung Keun;Kang, Kyo Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.989-998
    • /
    • 2014
  • Recently volcanic eruptions and activities occurring in many parts of world have become a common global concern to many countries. The severity of these Volcanic disasters, such as of Mt. Eyjafjallajokull in Iceland and Mt. Merapi in Indonesia, have caused damages and causalities reaching astronomical levels. The infrastructure is categorized into 18sections that appropriately reflecting the survey data collected from various government agents, current inhabitant and engineers to accumulate a database on the priorities and preferences of restoring and reconstructing many kinds of infrastructure and facilities. The survey data was collect by using the "Likert 5 Scale Method" which emphasized the importance and priority of reconstruction and restoration for the specific facilities and infrastructures. The data was corrugated, organized and used in plotting and planning a strategic recovery agenda. The survey results were analyzed and verified to ensure the validity and reliability of the data by using chi-square test. This paper presents that recovery period and recovery cost to the total damage of infrastructure and facilities were used to make a recovery network with implemented construction management method. The research is expected that a more efficient and prompt recovery protocol and recovery plan can be executed and can be use as a reference and database.

The consideration about the shielding effect of LEDITE (LEDITE를 이용한 방사선 차폐시설에 관한 고찰)

  • Min Je-soon;Lee Je-hee;Park heung-deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.15 no.1
    • /
    • pp.11-18
    • /
    • 2003
  • The concrete is usually used to build a radiation therapy facility and the enough concrete thickness for high energy x-ray beam is about 1 meter. But if the space is not enough to build a radiation therapy facility with concrete, the substitute for concrete is needed, and the Ledite can be a good substitute for concrete. In this study, we compared the Ledite with the concrete. The comparing list are the needed shielding thickness, the period of construction and the cost.

  • PDF

A Study on Mechanical Characteristics of Fiber Modified Emulsified Asphalt Mixture as Environmentally-Friend Paving Material (섬유보강 친환경 상온아스팔트 혼합물의 역학적 특성에 관한 연구)

  • Rhee Suk-Keun;Park Kyung-Won
    • International Journal of Highway Engineering
    • /
    • v.8 no.2 s.28
    • /
    • pp.23-30
    • /
    • 2006
  • Emulsified Asphalt Mixture(EAM) is more environmentally-friendly and cost-effective than typical Hot Mix Asphalt (HMA) because EAM does not produce carcinogenic substances, e.g., naphtha, kerosene, during the both of manufacturing and roadway construction process. Also, it does not require heating the aggregates and asphalt binder. However, EAM has some disadvantages. Generally EAM has a less load bearing capacity and more moisture susceptibility than conventional HMA. The study evaluated a Fiber modified EAM (FEAM) to increase load bearing capacity and to decrease moisture susceptibility of EAM. Modified Marshall mix design was developed to find Optimum Emulsion Contents (OEC), Optimum Water Contents (OWC), and Optimum Fiber Contents (OFC). A series of test were performed on the fabricated specimen with OBC, OWC, and OFC. Tests include Marshall Stability, Indirect Tensile Strength, and Resilient modulus test. Comparison analyses were performed among EAM, Fiber modified EAM (FEAM), and typical HMA to verify the applicability of EAM and FEAM in the field. Test results indicated that both of EAM and FEAM have an enough capability to resist medium traffic volume based on the Marshall mix design criteria. Also the study found that fiber modification is effective to increase the load bearing capacity and moisture damage resistance of EAM.

  • PDF

An Experimental Study on the Fire Monitoring System for Tunnel Using SMA and Fiber Optic Cable (형상기억합금과 광케이블을 이용한 터널의 화재감지 시스템 개발에 관한 실험적 연구)

  • Hwang, Ji-Hyun;Park, Ki-Tae;Lee, Kyu-Wan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.128-134
    • /
    • 2014
  • Recently, design and construction of street tunnels tend to focus on cost reduction and preservation of nature. Accordingly, research is actively being carried out to quickly detect fires when they occur in tunnels, which have partially closed structures. Among such research, fire detection methods using optical fiber sensors have a wide bandwidth and fast transmission speed, while using light as a medium. Therefore, it does not receive electrical interference and there is almost no loss of information during transmission, while also having little noise as well. In relation to this, a fire monitoring system that can accurately detect the location of fires in real time using shape memory alloy and optical cables was developed in this study. In order to verify the developed method, light loss measurement test was conducted according to indoor temperature changes, while also conducting fire simulation tests by installing test beds in common underground zones with different external environments of temperature and distance. Upon carrying out experiments, the fire monitoring system developed in this study was found to be able to detect fires in long distance sections in real time.

Prediction of Ultimate Strength and Strain of Concrete Columns Retrofitted by FRP Using Adaptive Neuro-Fuzzy Inference System (FRP로 보강된 콘크리트 부재의 압축응력-변형률 예측을 위한 뉴로퍼지모델의 적용)

  • Park, Tae-Won;Na, Ung-Jin;Kwon, Sung-Jun
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.1
    • /
    • pp.19-27
    • /
    • 2010
  • Aging and severe environments are major causes of damage in reinforced concrete (RC) structures such as buildings and bridges. Deterioration such as concrete cracks, corrosion of steel, and deformation of structural members can significantly degrade the structural performance and safety. Therefore, effective and easy-to-use methods are desired for repairing and strengthening such concrete structures. Various methods for strengthening and rehabilitation of RC structures have been developed in the past several decades. Recently, FRP composite materials have emerged as a cost-effective alternative to the conventional materials for repairing, strengthening, and retrofitting deteriorating/deficient concrete structures, by externally bonding FRP laminates to concrete structural members. The main purpose of this study is to investigate the effectiveness of adaptive neuro-fuzzy inference system (ANFIS) in predicting behavior of circular type concrete column retrofitted with FRP. To construct training and testing dataset, experiment results for the specimens which have different retrofit profile are used. Retrofit ratio, strength of existing concrete, thickness, number of layer, stiffness, ultimate strength of fiber and size of specimens are selected as input parameters to predict strength, strain, and stiffness of post-yielding modulus. These proposed ANFIS models show reliable increased accuracy in predicting constitutive properties of concrete retrofitted by FRP, compared to the constitutive models suggested by other researchers.

Surface Properties of Color Concrete Using Acid Stained Agent (표면 착색용 산화제를 사용한 컬러 콘크리트의 표면 특성)

  • Kim, Jin-Man;Jeong, Ji-Yong;Park, Hyo-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.265-272
    • /
    • 2011
  • Even though concrete is the most important material for building structures, its intrinsic gray color degrades urban esthetics. In order to improve this problem, coloring methods of mixing pigment in concrete batch and painting the surface of concrete surface have been tried. However, applications of the coloring methods in construction field are difficult due to high cost and low durability. Recently, acid stain agent is emerging as a new coloring method for concrete. It is able to apply a remarkably thin colored layer on a concrete surface from chemical reaction between acid and alkaline solutions. This study has examined the changes and variations of the surface layer of mortar specimen from chemical reaction of acid stained agents. The colors were changed into natural irregular stains according to aging. After the staining, no shape change was found from visible inspections. Microstructure of the colored surface applied with acid stained agent was much rougher than that of original mortar. When the colored layer was compared to original surface, crystals of hydrate such as $Ca(OH)_2$ and C-S-H gel were observed. Surface hardness was same or slightly higher in the colored layer. The value of pH was reduced by approximately 10%, weight contents of elements such as Ca, Si, and Al were low. In the chemical composition of the colored layer, the non-cement based elements of Mn, Cr, and Cu increased. Also, Fe and alkali elements of K and Na increased.

A Study on the boiler efficiency with selecting the uppermost burners in the 870MW opposite wall fired boiler (870MW 대향류 보일러에서 최상부층 버너 선택운전에 따른 보일러 효율변화 고찰)

  • Woo, Gwang-Yoon;Kim, Soo-Seok;Park, In-Chan;Ham, Young-Jun;Lee, Eung-Yoon
    • Plant Journal
    • /
    • v.13 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • In this study, the boiler efficiency and the change of boiler combustion state with the burner operation of the uppermost layer of 870MW opposite fired coal boiler were measured. Test results showed that the boiler efficiency was high in the order of the uppermost layer simultaneous operation of the front and rear burners, the front burner, and the rear burner operation. When the front and rear burners were operated simultaneously, the heat absorption rate of water walls in the boiler furnace was uniform at four side, and the temperature deviation of the left and right steam on the convection front surface decreased. As the heat absorption rate of the boiler improved, the loss of boiler exhaust gas decreased and the coal supply amount decreased by 8 tons/hour compared to the operation of the rear burner. This will contribute not only to the reduction of fuel cost but also to the reduction of greenhouse gas emissions.

  • PDF