• Title/Summary/Keyword: Parametric Curve

Search Result 233, Processing Time 0.025 seconds

Investigation of Safety and Design of Mooring Lines for Floating Wave Energy Conversion (부유식 파력발전장치용 계류선의 설계 및 안전성 검토에 관한 연구)

  • Jung, Dong-Ho;Nam, Bo-Woo;Shin, Seung-Ho;Kim, Hyeon-Ju;Lee, Ho-Saeng;Moon, Deok-Soo;Song, Je-Ha
    • Journal of Ocean Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.77-85
    • /
    • 2012
  • A study was performed on the design of a mooring line to maintain the position of a floating WEC (wave energy conversion) system. The procedure to design a mooring line is set up and the safety of the designed mooring system is evaluated using commercial software, Orcaflex. The characteristics curve for one line is analyzed to determine the properties and pretension of a mooring line. While considering the ocean environmental condition and importance of a floating WEC system, a multi-line layout is determined. A 4-point mooring system with 4 lines shows the instability in the yaw motion of the floating WEC system under a designed ocean environmental condition. The redesigned 4-point mooring system with 8 lines is found to be safe on the condition of a harsh ocean environment. The floating WEC system with the redesigned mooring system also shows stable motion in surge and pitch under operating conditions. From a parametric study on the mooring line length, the extreme value of the mooring line tension is found to be very sensitive to the pretension and length of mooring line. The results of this study can contribute to the establishment of a design procedure for mooring lines.

Time-Varying Income Elasticity of CO2 emission Using Non-Linear Cointegration (비선형 공적분모형을 이용한 이산화탄소 배출량의 소득탄력성 추정)

  • Lee, Sungro;Kim, Hyo-Sun
    • Environmental and Resource Economics Review
    • /
    • v.23 no.3
    • /
    • pp.473-496
    • /
    • 2014
  • This paper intends to test the non-linear relationship between $CO_2$ emissions and income by employing cointegration model of the time-varying income elasticity. We select France, UK, Italy, Japan, US, China, India, Mexico and Korea and use non-parametric time series analysis on each country in order to estimate its own effect of income on $CO_2$ emission. The main results indicate that the $CO_2$ emission-income elasticities vary over time and the income elasticities of the Annex I countries tend to be higher in absolute terms than those of developing countries. In addition, we find that emission-income elasticities decrease for Annex I countries over time, whereas those for developing countries increase.

Parametric Study on the Aerodynamic Drag of Ultra High-speed Train in Evacuated Tube - Part 1 (진공튜브 내 초고속열차의 공기저항 파라메타 연구 - 1)

  • Kwon, Hyeok-Bin;Kang, Bu-Byoung;Kim, Byeong-Yun;Lee, Du-Hwan;Jung, Hyun-Ju
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.1
    • /
    • pp.44-50
    • /
    • 2010
  • This study is devoted to understand the basic characteristics of the flowfield around a train in evacuated tube and to suggest an efficient numerical method to calculate the flowfield. To get steady-state solution in minimum calculation domain, various boundary condition have been tried for steady calculation and have been compared to the solution of unsteady calculation. At the train velocity of 300km/h, the aerodynamic drag results of both calculation method agreed very well. The drag ratio between on the open filed and in the tube from the calculation result by the suggested numerical method lied in the same fitting curve with that from the filed test of high-speed trains running in the line.

Three Dimensional Thermal Cycle Analysis of Mold in Repeated Forming Process of TV Glass (TV 유리의 반복 성형공정에서 3차원 금형 열사이클 해석)

  • Hwang, Jung-Hea;Choi, Joo-Ho;Kim, Jun-Bum
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.192-198
    • /
    • 2000
  • Three dimensional thermal cycle analysis of the plunger is carried out in repeated forming process of the TV glass, which is continued work of two dimensional analysis where an efficient method has been proposed. The plunger undergoes temperature fluctuation during a cycle due to the repeated contact and separation from the glass, which attains a cyclic steady state having same temperature history at every cycle. Straightforward analysis of this problem brings about more than 90 cycles to get reasonable solution. An exponential function fitting method is proposed, which finds exponential function to best approximate temperature values of 3 consecutive cycles, and new cycle is restarted with the fitted value at infinite time. Number of cases are analyzed using the proposed method and compared to the result of straightforward repetition, from which one finds that the method always reaches nearly convergent solution within $9{\sim}12$ cycles, but turns around afterwards without further convergence. Two step use is found most efficient, in which the exponential fitting is carried out fer the first 12 cycles, followed by simple repetition, which shows fast convergence expending only 6 additional cycles to get the accuracy within 2 error. This reduces the computation cycle remarkably from 90 to 18, which is 80% reduction. From the parametric studies, one reveals that the overall thermal behavior of the plunger in terms of cooling parameters and time is similar to that of 2 dimensional analysis.

  • PDF

A complete S-shape feed rate scheduling approach for NURBS interpolator

  • Du, Xu;Huang, Jie;Zhu, Li-Min
    • Journal of Computational Design and Engineering
    • /
    • v.2 no.4
    • /
    • pp.206-217
    • /
    • 2015
  • This paper presents a complete S-shape feed rate scheduling approach (CSFA) with confined jerk, acceleration and command feed rate for parametric tool path. For a Non-Uniform Rational B-Spline (NURBS) tool path, the critical points of the tool path where the radius of curvature reaches extreme values are found firstly. Then, the NURBS curve is split into several NURBS sub-curves or blocks by the critical points. A bidirectional scanning strategy with the limitations of chord error, normal/tangential acceleration/jerk and command feed rate is employed to make the feed rate at the junctions between different NURBS blocks continuous. To improve the efficiency of the feed rate scheduling, the NURBS block is classified into three types: short block, medium block and long block. The feed rate profile corresponding to each NURBS block is generated according to the start/end feed rates and the arc length of the block and the limitations of tangential acceleration/jerk. In addition, two compensation strategies are proposed to make the feed rate more continuous and the arc increment more precise. Once the feed rate profile is determined, a second-order Taylor's expansion interpolation method is applied to generate the position commands. Finally, experiments with two free-form NURBS curves are conducted to verify the applicability and accuracy of the proposed method.

Confinement models for high strength short square and rectangular concrete-filled steel tubular columns

  • Aslani, Farhad;Uy, Brian;Wang, Ziwen;Patel, Vipul
    • Steel and Composite Structures
    • /
    • v.22 no.5
    • /
    • pp.937-974
    • /
    • 2016
  • While extensive efforts have been made in the past to develop finite element models (FEMs) for concrete-filled steel tubular columns (CFSTCs), these models may not be suitable to be used in some cases, especially in view of the utilisation of high strength steel and high strength concrete. A method is presented herein to predict the complete stress-strain curve of concrete subjected to tri-axial compressive stresses caused by axial load coupled with lateral pressure due to the confinement action in square and rectangular CFSTCs with normal and high strength materials. To evaluate the lateral pressure exerted on the concrete in square and rectangular shaped columns, an accurately developed FEM which incorporates the effects of initial local imperfections and residual stresses using the commercial program ABAQUS is adopted. Subsequently, an extensive parametric study is conducted herein to propose an empirical equation for the maximum average lateral pressure, which depends on the material and geometric properties of the columns. The analysis parameters include the concrete compressive strength ($f^{\prime}_c=20-110N/mm^2$), steel yield strength ($f_y=220-850N/mm^2$), width-to-thickness (B/t) ratios in the range of 15-52, as well as the length-to-width (L/B) ratios in the range of 2-4. The predictions of the behaviour, ultimate axial strengths, and failure modes are compared with the available experimental results to verify the accuracy of the models developed. Furthermore, a design model is proposed for short square and rectangular CFSTCs. Additionally, comparisons with the prediction of axial load capacity by using the proposed design model, Australian Standard and Eurocode 4 code provisions for box composite columns are carried out.

The Diagnostic Assessment of Hand Elevation Test in Carpal Tunnel Syndrome

  • Ma, HyunJin;Kim, Insoo
    • Journal of Korean Neurosurgical Society
    • /
    • v.52 no.5
    • /
    • pp.472-475
    • /
    • 2012
  • Objective : The aim of this study is to establish the value of hand elevation test as a reproducible provocative test for the diagnosis of carpal tunnel syndrome (CTS). Methods : We had a prospective study of 45 hands of 38 patients diagnosed with CTS between April 2005 and February 2009. The diagnosis of CTS was based on the American Academy of Neurology clinical diagnostic criteria. Experimental and control group patients underwent Tinel's test, Phalen's test, carpal compression test and hand elevation test as provocative tests for CTS. Results : We used chi-square analysis to compare Tinel's test and Phalen's test, carpal compression test with hand elevation test. The sensitivity and specificity of the hand elevation test is 86.7% and 88.9% each. Tinel's test had 82.2% sensitivity and 88.9% specificity. Phalen's test had 84.4% sensitivity and 86.7% specificity. Carpal compression test had 84.4% sensitivity 82.2% specificity. Comparisons of sensitivity and specificity between hand elevation test and Tinel's test, Phalen's test, and carpal compression test had no statistically significant differences. To compare the diagnostic accuracies of four tests, the area under the non-parametric receiver operating character curve was applied. Conclusion : The hand elevation test has higher sensitivity and specificity than Tinel's test, Phalen's test, and carpal compression test. Chi-square statistical analysis confirms the hand elevation test is not ineffective campared with Tinel's test, Phalen's test, and carpal compression test.

Medical Parameter Extraction Using Time-Density Data in Contrast-Enhanced Ultrasound Image Sequence (조영증강 초음파영상에서 밀도변화 데이터를 이용한 진단 파라미터 추출 기법)

  • Lee, Jun-Yong;Jung, Joong-Eun;Kim, Ho-Joon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.7
    • /
    • pp.297-300
    • /
    • 2015
  • In medical ultrasonography, transit time and contrast enhancement patterns are considered as important parameters to analyze liver diseases. In many recent researches, time-intensity curves(TIC) have been used for calculating the transit time of the contrast agents. However, the intensity curve may include the variations which are caused by the micro-bubble effect of contrast agents. In this paper, we propose a complementary approach to diagnostic parameter extraction which utilizes a density information as well as the intensity data. The proposed technique improves the accuracy in extraction of the transit time and velocity of contrast agents for detection and characterization of focal liver lesions. Through the experiments using a set of clinical data, we show that the proposed methods can improve the reliability of the parametric image data.

Bioequivalence of Ramiprin® tablet to Tritace Protect® tablet (Ramipril 10 mg) (트리테이스프로텍트 ®정(라미프릴 10mg)에 대한 라미프린 ®정의 생물학적동등성)

  • Oh, Soo-Yeon;Cho, Jong-Tae;Kim, Hyung-Gun;Kim, Yoon-Gyoon
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.1
    • /
    • pp.73-78
    • /
    • 2008
  • To evaluate the bioequivalence of two ramipril formulations, a standard 2-way randomized cross-over study was conducted in twenty-six healthy male Korean volunteers. A single oral dose of 10 mg of test formulation $Ramiprin^{(R)}$ (tablet) or reference formulation Tritace $Protect^{(R)}$ (tablet) was administered with one-week washout period. Plasma concentrations of ramipril were assayed over a period of 12 hr with a well validated method using liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). The values of area under the plasma concentration-time curve, from time zero to last sampling time $(AUC_t)$ and from time zero to time infinity $(AUC_{inf})$ were $77.45{\pm}44.78\;and\;78.96{\pm}45.64$ for test, and $70.30{\pm}42.27\;and\;71.99{\pm}43.55ng\;hr/mL$ for reference formulation, respectively. Similarly, maximum concentration $(C_{max})$ and elimination half-life $(t_{1/2})$ were $65.61{\pm}19.96ng/mL$ and $2.15{\pm}0.75hr$ for test, and $63.63{\pm}25.50ng/mL$ and $2.16{\pm}0.73hr$ for reference formulations, respectively. Time to reach maximum concentration $(T_{max})$ for the test and the reference, were $0.51{\pm}0.22hr\;and\;0.52{\pm}0.18hr$, respectively. The parametric 90% confidence intervals on the mean of the differences between the two formulations (test-reference) of the log-transformed values of $AUC_t\;and\;C_{max}$ were 1.03 to 1.19 and 0.98 to 1.17, respectively. The overall results indicate that the two formulations are bioequivalent and can be prescribed interchangeably.

The Simulation and Experiment of Flexible Media with High Exit Velocity (고속의 출구속도를 가지는 유연매체의 거동해석 및 실험)

  • Hong, Sung-Kwon;Jee, Jung-Geun;Jang, Yong-Hoon;Park, No-Cheol;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.380-383
    • /
    • 2006
  • The media transport system is used in a printer, a ATM(Automated Tellor Machine), and so on. The media transport system has many problems through miniaturization and rapid transportation of these machines. In the paper feeding mechanism, it is important to feed the sheet without jamming under any conditions. To avoid sheet jamming, first we need to predict the behavior of the sheet exactly. In this paper, the analysis of media behavior is based on J. Stolte's studies. In all of OA machines, a flexible beam or plate is pushed from the channel. The motion may be constrained by guides. This leads to a transient and geometrically nonlinear problem. The behavior of paper is simulated by dynamic elastica theory. The shape of guide is represented by parametric cubic curve. But J. Stolte's studies did not considered contact condition between sheet and guide. So Klarbring's Model. will be applied. And the analysis of flexible media has to include aerodynamic effect for more exact behavior analysis, because the flexible media can be deformed drastically by a little force. Therefore aerodynamic force must be applied to the governing equation. Lastly, the simulation of this model is performed, and the experiment is performed for verification of this model. The experimental results of low exit velocity are consistent with the simulation results, however experimental results of high exit velocity do not agree well with analytical results. The reason is that there may be other effects like nip Phenomena

  • PDF