• Title/Summary/Keyword: Parameter imaging

Search Result 261, Processing Time 0.026 seconds

Analysis of Contrast Medium Dilution Rate for changes in Tube Current and SOD, which are Parameters of Lower Limb Angiography Examination (하지 혈관조영검사 시 매개변수인 관전류와 SOD에 변화에 대한 조영제 희석률 분석)

  • Kong, Chang gi;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.603-612
    • /
    • 2020
  • This study has a purpose to look into the effect of the relationship between the Tube current (mA) and SOD(Source to Object Distance), which is a parameter of lower limb angiography examination, and the dilution rate of the contrast medium concentration (300, 320, 350) on the image. To that end, using 3 mm vessel model water phantom, a vessel model custom made in the size of peripheral vessel diameter, this study measured relationships between change of parameters, such as tube current (mA), SOD and varying concentrations (300, 320, 350) of contrast medium dilution into SNR and CNR values while analyzing the coefficients of variance(cv<10). The software used to measure SNR and CNR values was Image J 1.50i from NIH (National Institutes of Health, USA). MPV (mean pixel value) and SD (standard deviation) were used after verifying numerically the image signal for region of interest (ROI) and background on phantom from the DICOM (digital imaging and communications in medicine) 3.0 file transmitted to PACS. As to contrast medium dilution by the change of tube current, when 146 mA and 102 mA were compared, For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 22.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As to contrast medium dilution by concentration for SOD change, when SOD's (32.5 cm and 12.5 cm) were compared,For both SNR and CNR, the coefficient of variation value was less than 10 until the section of CM: N/S dilution (100% ~ 30% : 70%) but CM: N/S dilution rate (20%: 80% ~ 10% : 90%) the coefficient of variation was 10 or more. As a result, set a low tube current value in other tests or procedures including peripheral angiography of the lower extremities in the intervention, and make the table as close as possible to the image receiver, and adjust the contrast agent concentration (300) to CM: N/S dilution (30%: 70%). ) Is suggested as the most efficient way to obtain images with an appropriate concentration while simultaneously reducing the burden on the kidney and the burden on exposure.

Sensitivity Analysis of Meteorology-based Wildfire Risk Indices and Satellite-based Surface Dryness Indices against Wildfire Cases in South Korea (기상기반 산불위험지수와 위성기반 지면건조지수의 우리나라 산불발생에 대한 민감도분석)

  • Kong, Inhak;Kim, Kwangjin;Lee, Yangwon
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.2
    • /
    • pp.107-120
    • /
    • 2017
  • There are many wildfire risk indices worldwide, but objective comparisons between such various wildfire risk indices and surface dryness indices have not been conducted for the wildfire cases in Korea. This paper describes a sensitivity analysis on the wildfire risk indices and surface dryness indices for Korea using LDAPS(Local Analysis and Prediction System) meteorological dataset on a 1.5-km grid and MODIS(Moderate-resolution Imaging Spectroradiometer) satellite images on a 1-km grid. We analyzed the meteorology-based wildfire risk indices such as the Australian FFDI(forest fire danger index), the Canadian FFMC(fine fuel moisture code), the American HI(Haines index), and the academically presented MNI(modified Nesterov index). Also we examined the satellite-based surface dryness indices such as NDDI(normalized difference drought index) and TVDI(temperature vegetation dryness index). As a result of the comparisons between the six indices regarding 120 wildfire cases with the area damaged over 1ha during the period between January 2013 and May 2017, we found that the FFDI and FFMC showed a good predictability for most wildfire cases but the MNI and TVDI were not suitable for Korea. The NDDI can be used as a proxy parameter for wildfire risk because its average CDF(cumulative distribution function) scores were stably high irrespective of fire size. The indices tested in this paper should be carefully chosen and used in an integrated way so that they can contribute to wildfire forecasting in Korea.

A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner (X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구)

  • Jung, Jae-Yong;Lee, Choong-Il;Min, Jeong-Hwan;Kim, Yon-Lae;Lee, Seong-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, we evaluated the dose response of MAGAT (Methacrylic Acid Gelatin gel and THPC) normoxic polymer gel dosimeters based on the X-ray CT scanner. To perform this study, we determined the proper ratio of the gel composition and acquired X-ray scan parameters. MAGAT gel dosimeters were manufactured using MAA (MethacrylicAcid) and gelatin of various concentration, irradiated up to 20 Gy. We obtained the 20 CT images from the irradiated gel dosimeters by using on a Phillips Brilliance Big Bore CT scanner with the various scan parameters. This CT images were used to determine the $N_{CT}$-dose response, dose sensitivity and dose resolution As an amount of MAA and gelatin were increase, the slope and intercept were increase in each MAGAT gel dosimeter with various concentration of the $N_{CT}$-dose response curve. The dose sensitivity was $0.38{\pm}0.08$ to $0.859{\pm}0.1$ and increased were amount of the MAA was increased or the gelatin was decreased. However, the change of gelatin concentration was very small compare to MAA. The Dose resolution ($D_{\Delta}^{95%}$) varies considerably from 2.6 to 6 Gy, dependent on dose resolution and CT image noise. The slope and dose sensitivity was almost ident verywith the variation of the tube voltage, tube current and slice thickness in the dose response curve, but the noise (standard deviation of averamalg CT number) was decreased when the tube voltage, tube current and slice thickness are increase. The optimal MAGAT polymer gel dosimeter based on the CT were evaluated to determine the CT imaging scan parameters of the maximum tube voltage, tube current and slice thickness (commonly used in clinical) using the composition ratio of a 9% MAA, 8% gelatin and 83% water. This study could get proper composition ratio and scan parameter evaluating dose response of MAGAT normoxic polymer gel dosimeter using CT scanner.

Assessment of Quantitative Analysis Methods for Lung F-18-Fluorodeoxyglucose PET (폐 종양 FDG PET 영상의 다양한 추적자 역학 분석 방법 개발과 유용성 고찰)

  • Kim, Joon-Young;Choi, Yong;Choi, Joon-Young;Lee, Kyung-Han;Kim, Sang-Eun;Choe, Yearn-Seong;Kim, Yong-Jin;Kim, Byung-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.332-343
    • /
    • 1998
  • Purpose: The purpose of this study was to assess the diagnostic accuracy of various quantitation methods using F-18-fluorodeoxyglucose (FDG) in patients with malignant or benign lung lesion. Materials and Methods: 22 patients (13 malignant including 5 bronchoalverolar cell cancer; 9 benign lesions including 1 hamartoma and 8 active inflammation) were studied after overnight fasting. We performed dynamic PET imaging for 56 min after injection of 370 MBq (10 mCi) of FDG. Standardized uptake values normalized to patient's body weight and plasma glucose concentration (SUVglu) were calculated. The uptake rate constant of FDG and glucose metabolic rate were quantified using Patlak graphical analysis (Kpat and MRpat), three compartment-five parameter model (K5p, MR5p), and six parameter model taking into account heterogeneity of tumor tissue (K6p, MR6p). Areas under receiver operating characteristic curves (ROC) were calculated for each method. Results: There was no significant difference of rate constant or glucose metabolic rate measured by various quantitation methods between malignant and benign lesions. The area under ROC curve were 0.73 for SUVglu, 0.66 for Kpat, 0.77 for MRpat, 0.71 for K5p, 0.73 for MR5p, 0.70 for K6p, and 0.78 for MR6p. No significant difference of area under the ROC curve between these methods was observed except the area between Kpat vs. MRpat (p<0.05). Conclusion: Quantitative methods did not improve diagnostic accuracy in comparison with nonkinetic methods. However, the clinical utility of these methods needs to be evaluated further in patients with low pretest likelihood of active inflammation or bronchoalveolar cell carcinoma.

  • PDF

Evaluation of waterlogging tolerance using chlorophyll fluorescence reaction in the seedlings of Korean ginseng (Panax ginseng C. A. Meyer) accessions (엽록소 형광반응을 이용한 인삼 유전자원의 습해 스트레스 평가)

  • Jee, Moo Geun;Hong, Young Ki;Kim, Sun Ick;Park, Yong Chan;Lee, Ka Soon;Jang, Won Suk;Kwon, A Reum;Seong, Bong Jae;Kim, Me-Sun;Cho, Yong-Gu
    • Journal of Plant Biotechnology
    • /
    • v.49 no.3
    • /
    • pp.240-249
    • /
    • 2022
  • Measuring chlorophyll fluorescence (CF) is a useful tool for assessing a plant's ability to tolerate abiotic stresses such as drought, waterlogging and high temperature. Korean ginseng is highly sensitive to water stress in paddy fields. To evaluate the possibility of non-destructively diagnosing waterlogging stress using chlorophyll fluorescence (CF) imaging techniques, we screened 57 ginseng accessions for waterlogging tolerance. To evaluate waterlogging tolerance among the 2-year-old Korean ginseng accessions, we treated ginseng plants with water stress for 25 days. The physiological disorder rate was characterized through visual assessment (an assigned score of 0-5). The physiological disorder rates of Geumjin, Geumsun and GS00-58 were lower than that of other accessions. In contrast, lines GS97-62, GS97-69 and GS98-1-5 were deemed susceptible. Root traits, chlorophyll content and the reduction rates decreased in most ginseng accessions. Further, these metrics were significantly lower in susceptible genotypes compared to resistant ones. All CF parameters showed a positive or negative response to waterlogging stress, and this response continuously increased over the treatment time among the genotypes. The CF parameter Fv/Fm was used to screen the 57 accessions, and the results showed clear differences in Fv/Fm between the susceptible and resistant genotypes. Susceptible genotypes had an especially low Fv/Fm value of less than 0.8, reflecting damage to the reaction center of photosystem II. It is concluded that Fv/Fm can be used as a CF parameter index for screening waterlogging stress tolerance in ginseng genotypes.

Effectiveness Assessment on Jaw-Tracking in Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Esophageal Cancer (식도암 세기조절방사선치료와 용적세기조절회전치료에 대한 Jaw-Tracking의 유용성 평가)

  • Oh, Hyeon Taek;Yoo, Soon Mi;Jeon, Soo Dong;Kim, Min Su;Song, Heung Kwon;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.33-41
    • /
    • 2019
  • Purpose : To evaluate the effectiveness of Jaw-tracking(JT) technique in Intensity-modulated radiation therapy(IMRT) and Volumetric-modulated arc therapy(VMAT) for radiation therapy of esophageal cancer by analyzing volume dose of perimetrical normal organs along with the low-dose volume regions. Materials and Method: A total of 27 patients were selected who received radiation therapy for esophageal cancer with using $VitalBeam^{TM}$(Varian Medical System, U.S.A) in our hospital. Using Eclipse system(Ver. 13.6 Varian, U.S.A), radiation treatment planning was set up with Jaw-tracking technique(JT) and Non-Jaw-tracking technique(NJT), and was conducted for the patients with T-shaped Planning target volume(PTV), including Supraclavicular lymph nodes(SCL). PTV was classified into whether celiac area was included or not to identify the influence on the radiation field. To compare the treatment plans, Organ at risk(OAR) was defined to bilateral lung, heart, and spinal cord and evaluated for Conformity index(CI) and Homogeneity index(HI). Portal dosimetry was performed to verify a clinical application using Electronic portal imaging device(EPID) and Gamma analysis was performed with establishing thresholds of radiation field as a parameter, with various range of 0 %, 5 %, and 10 %. Results: All treatment plans were established on gamma pass rates of 95 % with 3 mm/3 % criteria. For a threshold of 10 %, both JT and NJT passed with rate of more than 95 % and both gamma passing rate decreased more than 1 % in IMRT as the low dose threshold decreased to 5 % and 0 %. For the case of JT in IMRT on PTV without celiac area, $V_5$ and $V_{10}$ of both lung showed a decrease by respectively 8.5 % and 5.3 % in average and up to 14.7 %. A $D_{mean}$ decreased by $72.3{\pm}51cGy$, while there was an increase in radiation dose reduction in PTV including celiac area. A $D_{mean}$ of heart decreased by $68.9{\pm}38.5cGy$ and that of spinal cord decreased by $39.7{\pm}30cGy$. For the case of JT in VMAT, $V_5$ decreased by 2.5 % in average in lungs, and also a little amount in heart and spinal cord. Radiation dose reduction of JT showed an increase when PTV includes celiac area in VMAT. Conclusion: In the radiation treatment planning for esophageal cancer, IMRT showed a significant decrease in $V_5$, and $V_{10}$ of both lungs when applying JT, and dose reduction was greater when the irradiated area in low-dose field is larger. Therefore, IMRT is more advantageous in applying JT than VMAT for radiation therapy of esophageal cancer and can protect the normal organs from MLC leakage and transmitted doses in low-dose field.

$^{17}O$ NMR Study On Water Excharge Rate of Paramagnetic Contrast Agents ($^{17}O$ NMR 기법을 이용한 상자성 자기공명조영제의 물분자 교환에 관한 연구)

  • Yongmin Chang;Sung Wook Hong;Moon Jung Hwang;Il Soo Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 2001
  • Purpose : The water exchange rate between bulk water and bound water is an important parameter in deciding the efficiency of paramagnetic contrast agents. In this study, we evaluated the water exchange rates of various Gd-chelates using oxygen-17 NMR technique. Material and Methods : The samples (Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, Gd-EOB-DTPA) were prepared by mixing 5% $^{17}O-enriched$ water (Isotech, USA). The pH of the samples was adjusted to physiological value [pH=7.0] by buffer solution. The variable temperature $^{17}O-NMR$ measurements were performed using Bruker-600 (14.1 T, 81.3 MHz) spectrometer. Bruker VT-1000 temperature control units were used to stabilize the temperature. The $^{17}O$ spin-spin relaxation times (T2) were measured using Carr-Purcell-Meiboom-Gill (CPMG)I pulse sequence with 24 echo trains. The variable temperature T2 relaxation data were then fitted into Solomon-Bloembergen equations using least square fit algorithm to estimate the water exchange times. Results : From the measured $^{17}O-NMR$ relaxation rates, the determined water exchange rates at 300K are $0.42{\;}{\mu}s$ for Gd-DTPA, $1.99{\;}{\mu}s$ for Gd-DTPA-BMA, $0.27{\;}{\mu}s$ for Gd-DOTA, and $0.11{\;}{\mu}s$ for Gd-EOB-DTPA. The Gd-DTPA-BMA showed slowest exchange whereas Gd-EOB-DTPA had fastest water exchange rate. In addition, it was found that the water exchange rates (${\tau}_m$) of all samples had exponential temperature dependence with different decay constant. Conclusion : $^{17}O-NMR$ relaxation rate measurements, when combined with variable temperature technique, provide a solid tool for studying water exchange rate, which is very important in investigating the detailed mechanism of relaxation enhancement effect of the paramagnetic contrast agents.

  • PDF

Diagnostic Performance of Combined Single Photon Emission Computed Tomographic Scintimammography and Ultrasonography Based on Computer-Aided Diagnosis for Breast Cancer (유방 SPECT 및 초음파 컴퓨터진단시스템 결합의 유방암 진단성능)

  • Hwang, Kyung-Hoon;Lee, Jun-Gu;Kim, Jong-Hyo;Lee, Hyung-Ji;Om, Kyong-Sik;Lee, Byeong-Il;Choi, Duck-Joo;Choe, Won-Sick
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.3
    • /
    • pp.201-208
    • /
    • 2007
  • Purpose: We investigated whether the diagnostic performance of SPECT scintimammography (SMM) can be improved by adding computer-aided diagnosis (CAD) of ultrasonography (US). Materials and methods: We reviewed breast SPECT SMM images and corresponding US images from 40 patients with breast masses (21 malignant and 19 benign tumors). The quantitative data of SPECT SMM were obtained as the uptake ratio of lesion to contralateral normal breast. The morphologic features of the breast lesions on US were extracted and quantitated using the automated CAD software program. The diagnostic performance of SPECT SMM and CAD of US alone was determined using receiver operating characteristic (ROC) curve analysis. The best discriminating parameter (D-value) combining SPECT SMM and the CAD of US was created. The sensitivity, specificity and accuracy of combined two diagnostic modalities were compared to those of a single one. Results: Both SPECT SMM and CAD of US showed a relatively good diagnostic performance (area under curve = 0.846 and 0.831, respectively). Combining the results of SPECT SMM and CAD of US resulted in improved diagnostic performance (area under curve =0.860), but there was no statistical differerence in sensitivity, specificity and accuracy between the combined method and a single modality. Conclusion: It seems that combining the results of SPECT SMM and CAD of breast US do not significantly improve the diagnostic performance for diagnosis of breast cancer, compared with that of SPECT SMM alone. However, SPECT SMM and CAD of US may complement each other in differential diagnosis of breast cancer.

Assessment of Metabolic Impairment in Alzheimer's Disease with [$^{18}F$]FDG PET: Validity and Role of Simplified Tissue Radioactivity Ratio Analysis (알쯔하이머병에서 양전자방출단층촬영을 이용한 국소뇌포도당대사의 변화에 관한 연구)

  • Kim, Sang-Eun;Na Duk-Lyul;Lee, Jeong-Rim;Choi, Yong;Lee, Kyung-Han;Choe Yearn-Seong;Kim, Doh-Kwan;Kim, Byung-Tae;Lee, Kwang-Ho;Kim, Seung-Tai P.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.299-314
    • /
    • 1996
  • The purpose of the present study was to validate the use of tissue radioactivity ratios instead of regional metabolic rates for the assessment of regional metabolic changes in Alzheimer's disease(AD) with [$^{18}F$]FDG PET and to examine the correlation of ratio indices with the severity of cognitive impairment in AD. Thirty-seven AD Patients(age $68{\pm}9 yrs$, $mean{\pm}s.d.$; 36 probable and 1 definite AD), 28 patients with dementia of non-Alzheimer type(age $66{\pm}7 yrs$), and 17 healthy controls(age $66{\pm}4 yrs$) underwent [$^{18}F$]FDG PET imaging. Two simplified radioactivity ratio indices were calculated from 37-66 min image: region-to-cerebellar radioactivity ratio(RCR) and a composite radioactivity ratio(a ratio of radioactivity in the most typically affected regions over the least typically affected regions: CRR). Local cerebral metabolic rate for glucose(LCMRglu) was also measured using a three-compartment, five-parameter tracer kinetic model. The ratio indices were significantly lower in AD patients than in controls(RCR in temporoparietal cortex, $0.949{\pm}0.136$ vs. $1.238{\pm}0.129$, p=0.0004; RCR in frontal cortex, $1.027{\pm}0.128$ vs. $1.361{\pm}0.151$, p<0.0001; CRR, $0.886{\pm}0.096$ vs. $1.032{\pm}0.042$. p=0.0024). On the RCR analysis, 86% of AD patients showed a pattern of bilateral temporoparietal hypometabolism with or without frontal involvement; hypometabolism was unilateral in 11% of the patients. When bilateral temporoparietal hypometabolism was considered to be suggestive of AD, the sensitivity and specificity of the RCR analysis for the differential diagnosis of AD were 86% and 73%, respectively. The RCR was correlated significantly with the macroparameter K [$K_1k_3/(k_2+k_3)$] (r=0.775, p<0.0001) and LCMRglu(r=0.633, p=0.0002) measured using the kinetic model. In patients with AD, both average RCR of cortical association areas and CRR were correlated with Mini-Mental Status Examination(r=0.565, p=0.0145; r=0.642, p=0.0031, respectively), Clinical Dementia Rating(r=-0.576, p=0.0124; r=-0.591, p=0.0077), and total score of Mattis Dementia Rating Scale (r=0.574, p=0.0648; r=0.737, p=0.0096). There were also significant correlations between memory and language impairments and corresponding regional RCRs. The results suggest that the [$^{18}F$]FDG PET ratio indices, RCR and CRR, reflect global and regional metabolic rates and correlate with the severity of cognitive impairment in AD. The simplified ratio analysis may be clinically useful for the differential diagnosis and serial monitoring of the disease.

  • PDF

Selection of TI for Suppression Fat Tissue of SPAIR and Comparative Study of SPAIR and STIR of Brain Fast SE T2 Weighted Imaging (뇌의 고속스핀에코 T2강조영상에서 지방조직 억제를 위한 SPAIR의 반전시간(TI) 결정 및 STIR 영상과의 비교 연구)

  • Lee, Hoo-Min;Kim, Ham-Gyum;Kong, Seok-Kyo
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.95-99
    • /
    • 2009
  • The purpose of this research is to seek SPAIR's reversal time (TI) which satisfies two conditions ; maintaining the suppression ability of fat tissue and simultaneously minimizing the inhomogeneity of fat tissue in T2 high-speed spin echo 3.0T magnetic resonance image (MRI) of the brain, and to compare SPAIR with STIR which is fat-suppression technique. The reversal times (TI) of SPAIR protocol are set to 1/2, 1/3, 1/6 and 1/12 of SPAIR TR (420 msec), namely 210 msec (8 people), 140 msec (26 people), 70 msec (26 people) and 35 msec (18 people) and STIR TI is set with 250 msec (26 people). With these parameter sets, we acquired the axis direction 104 images of the brain. In ROI ($50\;mm^2$) of output image, signal intensities of the fatty tissue, the muscular tissue, and the background were measured and the CNRs of fatty tissue and the muscular tissue were calculated. The inhomogeneity of the fatty tissue is SD/mean, where SD is the standard deviation and 'mean' is a average fatty tissue signal. Consequently, SPAIR TI is determined on either 1/3 or 1/6 of TR (420 ms) ; 140 ms or 70 ms. Because the difference of statistics in fat-suppression ability and inhomogeneity of fatty tissue is very small (p < 0.001), Selecting 140 ms seems to be better choice for the image quality. Meanwhile, Comparing SPAIR (TI : 140 ms) with STIR, the fat-suppression is not able to be considered statistically (p < 0.252), but the image quality is able to be considered statistically (p < 0.01). In conclusion, SPAIR is better than STIR in the image quality.

  • PDF