Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

Retrieval of Fire Radiative Power from Himawari-8 Satellite Data Using the Mid-Infrared Radiance Method (히마와리 위성자료를 이용한 산불방사열에너지 산출)

  • Kim, Dae Sun;Lee, Yang Won
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.4
    • /
    • pp.105-113
    • /
    • 2016
  • Fire radiative power(FRP), which means the power radiated from wildfire, is used to estimate fire emissions. Currently, the geostationary satellites of East Asia do not provide official FRP products yet, whereas the American and European geostationary satellites are providing near-real-time FRP products for Europe, Africa and America. This paper describes the first retrieval of Himawari-8 FRP using the mid-infrared radiance method and shows the comparisons with MODIS FRP for Sumatra, Indonesia. Land surface emissivity, an essential parameter for mid-infrared radiance method, was calculated using NDVI(normalized difference vegetation index) and FVC(fraction of vegetation coverage) according to land cover types. Also, the sensor coefficient for Himawari-8(a = 3.11) was derived through optimization experiments. The mean absolute percentage difference was about 20%, which can be interpreted as a favourable performance similar to the validation statistics of the American and European satellites. The retrieval accuracies of Himawari FRP were rarely influenced by land cover types or solar zenith angle, but parts of the pixels showed somewhat low accuracies according to the fire size and viewing zenith angle. This study will contribute to estimation of wildfire emissions and can be a reference for the FRP retrieval of current and forthcoming geostationary satellites in East Asia.

Classification of Fall in Sick Times of Liver Cirrhosis using Magnetic Resonance Image (자기공명영상을 이용한 간경변 단계별 분류에 관한 연구)

  • Park, Byung-Rae;Jeon, Gye-Rok
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.71-82
    • /
    • 2003
  • In this paper, I proposed a classifier of liver cirrhotic step using T1-weighted MRI(magnetic resonance imaging) and hierarchical neural network. The data sets for classification of each stage, which were normal, 1type, 2type and 3type, were obtained in Pusan National University Hospital from June 2001 to december 2001. And the number of data was 46. We extracted liver region and nodule region from T1-weighted MR liver image. Then objective interpretation classifier of liver cirrhotic steps in T1-weighted MR liver images. Liver cirrhosis classifier implemented using hierarchical neural network which gray-level analysis and texture feature descriptors to distinguish normal liver and 3 types of liver cirrhosis. Then proposed Neural network classifier teamed through error back-propagation algorithm. A classifying result shows that recognition rate of normal is 100%, 1type is 82.3%, 2type is 86.7%, 3type is 83.7%. The recognition ratio very high, when compared between the result of obtained quantified data to that of doctors decision data and neural network classifier value. If enough data is offered and other parameter is considered, this paper according to we expected that neural network as well as human experts and could be useful as clinical decision support tool for liver cirrhosis patients.

  • PDF

Analysis of fMRI Signal Using Independent Component Analysis (Independent Component Analysis를 이용한 fMRI신호 분석)

  • 문찬홍;나동규;박현욱;유재욱;이은정;변홍식
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.2
    • /
    • pp.188-195
    • /
    • 1999
  • The fMRI signals are composed of many various signals. It is very difficult to find the accurate parameter for the model of fMRI signal containing only neural activity, though we may estimating the signal patterns by the modeling of several signal components. Besides the nose by the physiologic motion, the motion of object and noise of MR instruments make it more difficult to analyze signals of fMRI. Therefore, it is not easy to select an accurate reference data that can accurately reflect neural activity, and the method of an analysis of various signal patterns containing the information of neural activity is an issue of the post-processing methods for fMRI. In the present study, fMRI data was analyzed with the Independent Component Analysis(ICA) method that doesn't need a priori-knowledge or reference data. ICA can be more effective over the analytic method using cross-correlation analysis and can separate the signal patterns of the signals with delayed response or motion related components. The Principal component Analysis (PCA) threshold, wavelet spatial filtering and analysis of a part of whole images can be used for the reduction of the freedom of data before ICA analysis, and these preceding analyses may be useful for a more effective analysis. As a result, ICA method will be effective for the degree of freedom of the data.

  • PDF

Evaluation of the Cause of Internal Jugular Vein Obstruction on Head and Neck Contrast Enhanced 3D MR Angiography Using Contrast Enhanced Computed Tomography (조영증강 전산화단층촬영술을 이용한 두경부 조영증강 삼차원 자기공명혈관촬영술에서 내경정맥 폐쇄의 원인 평가)

  • Gweon, Hye-Mi;Chung, Tae-Sub;Suh, Sang-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.41-47
    • /
    • 2011
  • Purpose : To evaluate the cause of internal jugular vein (IJV) obstruction on contrast enhanced 3D MR angiography (CE-MRA) using contrast enhanced computed tomography (CE-CT). Materials and Methods : A total number of 30 patients were enrolled, who underwent both head and neck CE-MRA and CE-CT from 2005 to 2008. We defined obstruction group which had IJV obstruction and control group which had no IJV obstruction on CE-MRA. The following parameters were measured from axial images of CE-CT: 1) diameter of IJV; 2) distance between the styloid process and ipsilateral lateral mass of the atlas; 3) maximum area of lateral mass of the atlas. Each parameter was compared between obstruction group and control group. Results : The diameter of IJV and distance between the styloid process and lateral mass of the atlas at IJV obstruction side in obstruction group were $1.6{\pm}1.0\;mm$ and $4.1{\pm}2.1\;mm$ respectively, which resulted in statistical significance (p<0.01). The maximum area of lateral mass of the atlas at IJV obstruction side in obstruction group was $103.4{\pm}25.3\;mm^2$ which is significantly larger than in control group (p<0.05). Conclusion : We found that the cause of IJV obstruction on CE-MRA could be narrow space between the styloid process and the lateral mass of the atlas, which was related with asymmetric larger area of lateral mass of atlas.

Image Registration for PET/CT and CT Images with Particle Swarm Optimization (Particle Swarm Optimization을 이용한 PET/CT와 CT영상의 정합)

  • Lee, Hak-Jae;Kim, Yong-Kwon;Lee, Ki-Sung;Moon, Guk-Hyun;Joo, Sung-Kwan;Kim, Kyeong-Min;Cheon, Gi-Jeong;Choi, Jong-Hak;Kim, Chang-Kyun
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.195-203
    • /
    • 2009
  • Image registration is a fundamental task in image processing used to match two or more images. It gives new information to the radiologists by matching images from different modalities. The objective of this study is to develop 2D image registration algorithm for PET/CT and CT images acquired by different systems at different times. We matched two CT images first (one from standalone CT and the other from PET/CT) that contain affluent anatomical information. Then, we geometrically transformed PET image according to the results of transformation parameters calculated by the previous step. We have used Affine transform to match the target and reference images. For the similarity measure, mutual information was explored. Use of particle swarm algorithm optimized the performance by finding the best matched parameter set within a reasonable amount of time. The results show good agreements of the images between PET/CT and CT. We expect the proposed algorithm can be used not only for PET/CT and CT image registration but also for different multi-modality imaging systems such as SPECT/CT, MRI/PET and so on.

  • PDF

Intravenous contrast media application using cone-beam computed tomography in a rabbit model

  • Kim, Min-Sung;Kim, Bok-Yeol;Choi, Hwa-Young;Choi, Yoon-Joo;Oh, Song-Hee;Kang, Ju-Hee;Lee, Sae-Rom;Kang, Ju-Han;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.31-39
    • /
    • 2015
  • Purpose: This study was performed to evaluate the feasibility of visualizing soft tissue lesions and vascular structures using contrast-enhanced cone-beam computed tomography (CE-CBCT) after the intravenous administration of a contrast medium in an animal model. Materials and Methods: CBCT was performed on six rabbits after a contrast medium was administered using an injection dose of 2 mL/kg body weight and an injection rate of 1 mL/s via the ear vein or femoral vein under general anesthesia. Artificial soft tissue lesions were created through the transplantation of autologous fatty tissue into the salivary gland. Volume rendering reconstruction, maximum intensity projection, and multiplanar reconstruction images were reconstructed and evaluated in order to visualize soft tissue contrast and vascular structures. Results: The contrast enhancement of soft tissue was possible using all contrast medium injection parameters. An adequate contrast medium injection parameter for facilitating effective CE-CBCT was a 5-mL injection before exposure combined with a continuous 5-mL injection during scanning. Artificial soft tissue lesions were successfully created in the animals. The CE-CBCT images demonstrated adequate opacification of the soft tissues and vascular structures. Conclusion: Despite limited soft tissue resolution, the opacification of vascular structures was observed and artificial soft tissue lesions were visualized with sufficient contrast to the surrounding structures. The vascular structures and soft tissue lesions appeared well delineated in the CE-CBCT images, which was probably due to the superior spatial resolution of CE-CBCT compared to other techniques, such as multislice computed tomography.

Serum interleukin-6, tumor necrosis factor-α and adiponectin levels in Kawasaki disease (가와사키병 환자의 혈청 interleukin-6, tumor necrosis factor-α, Adiponectin 치에 대한 연구)

  • An, Jung;Kim, Han Gyu;Sohn, Sejung;Hong, Young Mi
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.1
    • /
    • pp.41-47
    • /
    • 2010
  • Purpose : Adiponectin is an endogenous modulator of vascular remodeling that suppresses vascular inflammation. However, the role of adiponectin in Kawasaki disease (KD) has not been elucidated. The purpose of this study is to investigate the correlation between serum adiponectin level and several parameters, such as interleukin (IL)-6, tumor necrosis factor $(TNF)-{\alpha}$, lipid profile, and C reactive protein (CRP), and to clarify the association between adiponectin and cardiac function. Methods : Twenty-two KD patients (22 patients in acute phase and 20 patients in subacute phase) were enrolled in the study group. The control group consisted of 31 subjects (13 febrile patients and 18 healthy children). Both groups underwent blood sampling and tissue Doppler imaging (TDI). Results : CRP was significantly increased in the KD group compared with the control group. There were no significant differences in serum $TNF-{\alpha}$, IL-6, and adiponectin levels between groups. However, a negative correlation was found between adiponectin level and CRP level or platelet count. Systolic myocardial velocity and A myocardial velocity measured by TDI were decreased significantly in the acute KD group compared with the subacute KD group and control group. Positive correlations were found between adiponectin level and systolic myocardial velocity or A myocardial velocity. Conclusion : In acute KD patients, low adiponectin level was related to severe inflammatory reactions and decreased left ventricular functions.

The Effect of Acoustic Velocity of Ultrasonographic Equipment Using an N-365 Multipurpose Phantom (N-365 다목적팬텀에서 초음파진단장치의 음속변화 효과)

  • Kim, Yon-Min;Shim, Jae-Goo;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.4
    • /
    • pp.221-225
    • /
    • 2017
  • To evaluate the performance of ultrasound imaging system, we investigated the change of spatial resolution according to changing sonic velocity change parameter provided by ultrasound equipment. Ultrasound phantom images were obtained using a 3.0 ~ 5.0 MHz convex transducer in an ultrasound diagnostic device used at a medical institution located at Iksan. N-365 multi-purpose ultrasound phantom was used to measure longitudinal distance measurement accuracy and longitudinal and transverse resolution. In the same manner, the sonic velocity of the ultrasound equipment was changed from 1580 m/sec to 1400 m/sec in six steps, and the full width at half maximum(FWHM) was measured using the image J program to determine whether the measured values were different. As a result, lateral resolution was measured from 1.91 mm to 5.3 mm according to the speed change, and the smallest FWHM was 1.91 mm at 1420 m/sec. The axial resolution was measured from 1.03 mm to 1.14 mm according to the speed change, and the smallest FWHM was 1.03 mm at 1400 m/sec. The slower the sound velocity of the ultrasound equipment, the shorter the length of longitudinal measurement.

A study on image registration and fusion of MRI and SPECT/PET (뇌의 단일 광자 방출 전산화 단층촬영 영상, 양전자 방출 단층 촬영 영상 그리고 핵자기공명 영상의 융합과 등록에 관한 연구)

  • Joo, Ra-Hyung;Choi, Yong;Kwon, Soo-Il;Heo, Soo-Jin
    • Progress in Medical Physics
    • /
    • v.9 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • Nuclear Medicine Images have comparatively poor spatial resolution, making it difficult to relate the functional information which they contain to precise anatomical structures. Anatomical structures useful in the interpretation of SPECT /PET Images were radiolabelled. PET/SPECT Images Provide functional information, whereas MRI mainly demonstrate morphology and anatomical. Fusion or Image Registration improves the information obtained by correlating images from various modalities. Brain Scan were studied on one or more occations using MRI and SPECT. The data were aligned using a point pair methods and surface matching. SPECT and MR Images was tested using a three dimensional water fillable Hoffman Brain Phantom with small marker and PET and MR Image was tested using a patient data. Registration of SPECT and MR Images is feasible and allows more accurate anatomic assessment of sites of abnormal uptake in radiolabeled studies. Point based registration was accurate and easily implemented three dimensional registration of multimodality data set for fusion of clinical anatomic and functional imaging modalities. Accuracy of a surface matching algorithm and homologous feature pair matching for three dimensional image registration of Single Photon Emission Computed Tomography Emission Computed Tomography (SPECT), Positron Emission Tomography (PET) and Magnetic Resonance Images(MRD was tested using a three dimensional water fill able brain phantom and Patients data. Transformation parameter for translation and scaling were determined by homologous feature point pair to match each SPECT and PET scan with MR images.

  • PDF