• Title/Summary/Keyword: Parameter Extraction

Search Result 492, Processing Time 0.035 seconds

Target Length Estimation of Target by Scattering Center Number Estimation Methods (산란점 수 추정방법에 따른 표적의 길이 추정)

  • Lee, Jae-In;Yoo, Jong-Won;Kim, Nammoon;Jung, Kwangyong;Seo, Dong-Wook
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.38 no.6
    • /
    • pp.543-551
    • /
    • 2020
  • In this paper, we introduce a method to improve the accuracy of the length estimation of targets using a radar. The HRRP (High Resolution Range Profile) obtained from a received radar signal represents the one-dimensional scattering characteristics of a target, and peaks of the HRRP means the scattering centers that strongly scatter electromagnetic waves. By using the extracted scattering centers, the downrange length of the target, which is the length in the RLOS (Radar Line of Sight), can be estimated, and the real length of the target should be estimated considering the angle between the target and the RLOS. In order to improve the accuracy of the length estimation, parametric estimation methods, which extract scattering centers more exactly than the method using the HRRP, can be used. The parametric estimation method is applied after the number of scattering centers is determined, and is thus greatly affected by the accuracy of the number of scattering centers. In this paper, in order to improve the accuracy of target length estimation, the number of scattering centers is estimated by using AIC (Akaike Information Criteria), MDL (Minimum Descriptive Length), and GLE (Gerschgorin Likelihood Estimators), which are the source number estimation methods based on information theoretic criteria. Using the ESPRIT algorithm as a parameter estimation method, a length estimation simulation was performed for simple target CAD models, and the GLE method represented excellent performance in estimating the number of scattering centers and estimating the target length.

Characteristics of KOMPSAT-3A Key Image Quality Parameters During Normal Operation Phase (정상운영기간동안의 KOMPSAT-3A호 주요 영상 품질 인자별 특성)

  • Seo, DooChun;Kim, Hyun-Ho;Jung, JaeHun;Lee, DongHan
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_2
    • /
    • pp.1493-1507
    • /
    • 2020
  • The LEOP Cal/Val (Launch and Early Operation Phase Calibration/Validation) was carried out during 6 months after KOMPSAT-3A (KOMPSAT-3A Korea Multi-Purpose Satellite-3A) was launched in March 2015. After LEOP Cal/Val was successfully completed, high resolution KOMPSAT-3A has been successfully distributing to users over the past 8 years. The sub-meter high-resolution satellite image data obtained from KOMPSAT-3A is used as basic data for qualitative and quantitative information extraction in various fields such as mapping, GIS (Geographic Information System), and national land management, etc. The KARI (Korea Aerospace Research Institute) periodically checks and manages the quality of KOMPSAT-3A's product and the characteristics of satellite hardware to ensure the accuracy and reliability of information extracted from satellite data of KOMPSAT-3A. To minimize the deterioration of image quality due to aging of satellite hardware, payload and attitude sensors of KOMPSAT-3A, continuous improvement of image quality has been carried out. In this paper, the Cal/Val work-flow defined in the KOMPSAT-3A development phase was illustrated for the period of before and after the launch. The MTF, SNR, and location accuracy are the key parameters to estimate image quality and the methods of the measurements of each parameter are also described in this work. On the basis of defined quality parameters, the performance was evaluated and measured during the period of after LEOP Cal/Val. The current status and characteristics of MTF, SNR, and location accuracy of KOMPSAT-3A from 2016 to May 2020 were described as well.

Application of peak based-Bayesian statistical method for isotope identification and categorization of depleted, natural and low enriched uranium measured by LaBr3:Ce scintillation detector

  • Haluk Yucel;Selin Saatci Tuzuner;Charles Massey
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3913-3923
    • /
    • 2023
  • Todays, medium energy resolution detectors are preferably used in radioisotope identification devices(RID) in nuclear and radioactive material categorization. However, there is still a need to develop or enhance « automated identifiers » for the useful RID algorithms. To decide whether any material is SNM or NORM, a key parameter is the better energy resolution of the detector. Although masking, shielding and gain shift/stabilization and other affecting parameters on site are also important for successful operations, the suitability of the RID algorithm is also a critical point to enhance the identification reliability while extracting the features from the spectral analysis. In this study, a RID algorithm based on Bayesian statistical method has been modified for medium energy resolution detectors and applied to the uranium gamma-ray spectra taken by a LaBr3:Ce detector. The present Bayesian RID algorithm covers up to 2000 keV energy range. It uses the peak centroids, the peak areas from the measured gamma-ray spectra. The extraction features are derived from the peak-based Bayesian classifiers to estimate a posterior probability for each isotope in the ANSI library. The program operations were tested under a MATLAB platform. The present peak based Bayesian RID algorithm was validated by using single isotopes(241Am, 57Co, 137Cs, 54Mn, 60Co), and then applied to five standard nuclear materials(0.32-4.51% at.235U), as well as natural U- and Th-ores. The ID performance of the RID algorithm was quantified in terms of F-score for each isotope. The posterior probability is calculated to be 54.5-74.4% for 238U and 4.7-10.5% for 235U in EC-NRM171 uranium materials. For the case of the more complex gamma-ray spectra from CRMs, the total scoring (ST) method was preferred for its ID performance evaluation. It was shown that the present peak based Bayesian RID algorithm can be applied to identify 235U and 238U isotopes in LEU or natural U-Th samples if a medium energy resolution detector is was in the measurements.

Quantifying Uncertainty of Vitamin C Determination in Infant Formula by Indophenol Titration Method (인도페놀 적정법에 의한 성장기용조제식 중 비타민 C 함량분석의 측정불확도 산정)

  • Jun, Jang-Young;Kwak, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • Uncertainty involved during determination of vitamin C content in infant formula was quantified by indophenol titration method. Uncertainty sources in measurand, such as purity, weight, final volume of standard, volume of standard solution used for titration, sample weight, final volume of sample, extraction solution used for titration, titration of extraction solution and standard solution by indophenol solution were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement (GUM) and Draft EURACHEM/CITAC Guide. Uncertainty parameters of each source in measurand were identified as resolution, reproducibility and stability of chemical balance, standard material purity, repeatability, reproducibility, end point of titration, 1 mL pipet, 5 mL autopipet, and 100 mL mass flask. Each uncertainty component was evaluated by types A and B and included to calculate combined uncertainty. Analytical test result for traceability under laboratorial conditions using Certified Reference Material (CRM) test was certified as $108.4{\pm}1.7mg/100g$, which was within CRM certification range of $114.6{\pm}6.6mg/100g$. Uncertainty test result of vitamin C content of 5 g sampling was $56.7{\pm}2.44mg/100g$. Uncertainty could be reduced by identification of uncertainty sources and components related with vitamin C determination by indophenol titration method and by decreasing uncertainty sources and components.

Soil Testing for Potassium in Upland Soils -Review on the Methodologies- (밭토양(土壤)에 대(對)한 가리(加里) 검정(檢定))

  • Hong, Chong Woon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.10 no.3
    • /
    • pp.153-170
    • /
    • 1977
  • Considering the ways for the possible improvement of soil test for upland crops, various methods for the evaluation of K supplying power and testing of available soil K were reviewed in terms of theoretical principles and practical usefulness of the each method. The review was also made on the characteristics of upland crops in K requirement and on the chemical properties of major korean upland and lowland rice soils in terms of K availability. Following is the few remarks drawn from the review. 1. Quite large number of methods have been known for the evaluation of K supplying power and testing for available soil K. In nature, they can be divided into two categories; capacity-based methods and intensity-based methcds. The capacity-based methods usually measure the exchangeable and some portion of nonexchangeable K, while the intensity-based methods suggest to consider the ractivity ratios of major cations in soil solution and the energy requirement for the replacement of exchangeable soil K into soil solution. 2. As methodology for extraction of interested part of soil K, chemical extraction, electrodialysis and ion exchange methods have been known. Among these, chemical extract ion is favorable because of its simplicity. However, recently suggested Electro-Ultra-Filtration method seems to merit further study for wider use for not only K but also other nutrient availability of soils. 3. The intensity-based methods, although they are more theoretical, because of their complexity, in methods may not be adapted for practical soil tests. 4. The exchangeable K which is rather simple to measure and which well reflects the status of K reserve as nonexchangeable and is immediate pool of water soluble K may be good, if not best, criterion of soil K availability to plant in common soil testing. 5. Because there are evidences that the abundance of available K alone may not be good inclication for availability of K to plant, it is recommendable to interprete the exchangeable K data as percent saturation of exchangeable K to total C. E. C. of soil for the recommend ation of K fertilizer based on soil tests. 6. Some pot and field trial results showed the trends that percent potassium saturation to total C. E. C. better serve as the parameter for K fertilizer recommendation.

  • PDF

Design of a Bit-Serial Divider in GF(2$^{m}$ ) for Elliptic Curve Cryptosystem (타원곡선 암호시스템을 위한 GF(2$^{m}$ )상의 비트-시리얼 나눗셈기 설계)

  • 김창훈;홍춘표;김남식;권순학
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.12C
    • /
    • pp.1288-1298
    • /
    • 2002
  • To implement elliptic curve cryptosystem in GF(2$\^$m/) at high speed, a fast divider is required. Although bit-parallel architecture is well suited for high speed division operations, elliptic curve cryptosystem requires large m(at least 163) to support a sufficient security. In other words, since the bit-parallel architecture has an area complexity of 0(m$\^$m/), it is not suited for this application. In this paper, we propose a new serial-in serial-out systolic array for computing division operations in GF(2$\^$m/) using the standard basis representation. Based on a modified version of tile binary extended greatest common divisor algorithm, we obtain a new data dependence graph and design an efficient bit-serial systolic divider. The proposed divider has 0(m) time complexity and 0(m) area complexity. If input data come in continuously, the proposed divider can produce division results at a rate of one per m clock cycles, after an initial delay of 5m-2 cycles. Analysis shows that the proposed divider provides a significant reduction in both chip area and computational delay time compared to previously proposed systolic dividers with the same I/O format. Since the proposed divider can perform division operations at high speed with the reduced chip area, it is well suited for division circuit of elliptic curve cryptosystem. Furthermore, since the proposed architecture does not restrict the choice of irreducible polynomial, and has a unidirectional data flow and regularity, it provides a high flexibility and scalability with respect to the field size m.

Effects of Drying Conditions on the Profile of Volatile Terpenoid and Colour of Schizandra Fruit(Schizandra Chinensis fructus) (건조 조건이 오미자의 휘발성 terpene류 및 색도에 미치는 영향)

  • Kim, Yun-Je;Lee, Young-Guen;Choi, Young-Whan;Kim, Yong-Chul
    • Journal of Life Science
    • /
    • v.18 no.8
    • /
    • pp.1066-1071
    • /
    • 2008
  • Schizandra fruit (Schizandra chinensis fructus) were dried by three processes, $50^{\circ}C$ (50HAD), $70^{\circ}C$ hot air (70HAD) and freeze drying process (FRD). Terpenoid were collected by SDE(Simultaneous Steam Distillation-Extraction) and followed by GC-MSD analysis. Also colour profile of each dried samples were measured by Hunter colorimeter. From fresh schizandra fruit, were detected 15 kinds of monoterpene, 28 kinds of sesquiterpene and 7 kinds of terpene alcohol. Myrcene(56.97 ${\mu}g/g$) and ${\gamma}$-terpinene(58.49 ${\mu}g/g$) were the major monoterpenes, ${\beta}$-elemene(120.16 ${\mu}g/g$), ${\alpha}$-bergamotene (103.45 ${\mu}g/g$), ${\gamma}$-selinene (75.97 ${\mu}g/g$), ${\beta}$-cubebene(66.69 ${\mu}g/g$), aristolene (51.25 ${\mu}g/g$) and ${\alpha}$-ylangene(28.06 ${\mu}g/g$) were the sesquiterpenes, and T-muurolol (96.45 ${\mu}g/g$) and terpinen-4-ol(46.02 ${\mu}g/g$) were the terpene alcohols. The dried samples lost more than half of terpenoid content of fresh schizandra fruit during early stage of drying process, and then the level of terpenoid content was not significantly changed. The content of sesquiterpenes appeared to increase until 6 day of FRD. The amount of residual terpene alcohols contained in schizandra fruit dried by FRD was more than those remained after drying by other processes, and schizandra fruit dried by 70HAD exhibited the least residual terpene alcohols. Brightness parameter $L^{\ast}$ decreased with the rise in the level of drying temperature, to which redness parameter $a^{\ast}$ and yellowness $b^{\ast}$ appeared to be similar.

Utility of $^{99m}Tc$-MAG3 Perfusion Indices in the Evaluation of Renal Transplant Function During Early Post-transplantation Period (이식 초기 이식신 기능 평가에서 $^{99m}Tc$-MAG3 신관류 지표의 유용성)

  • Kim, Sung-Hoon;Chung, Soo-Kyo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.497-507
    • /
    • 2000
  • Purpose: We have examined the utility of $^{99m}Tc$-MAG3 perfusion indices for assessing renal graft function in early post-transplantation period. Materials and Methods: Our study included 80 renal transplant recipients (48 men and 32 women, mean age: 40.3 years). Diagnosis was based on biopsy, laboratory data and clinical course. Renal scintigraphy (RS) was obtained using 100 MBq of $^{99m}Tc$-MAG3 from 11 days to 23 days of kidney transplantation. We measured 5 indices in whole-kidney (WK) and cortical (C) renograms; Hilson's perfusion index (PI), transplant perfusion index (TP) and transplant function index (TF) as perfusion parameter, and the time to peak activity (Tmax) and the ratio of renal counts at 20 min to that at 3 min (K20/3) as functional parameter. Results: The diagnoses at the day of RS were normal graft (NG) in 44, acute rejection (AR) in 14, acute tubular necrosis (ATN) in 10, and Cyclosporine A nephrotoxicity (CsA) in 12. TP and TF were significantly decreased in AR, ATN and CsA, compared to those in NG. K20/3 of AR and ATN wore significantly greater than that of NG. WK-Tmax of AR was significantly longer than that of NG. K20/3 of AR and C-K20/3 of ATN were significantly prolonged relative to those of CsA. There were no statistically significant perfusion indices among complication groups. Conclusion: TP and TF reflecting microperfusion and initial tubular extraction are reliable in assessing graft function. However, it is required to correlate perfusion indices with functional indices and clinical course in differentiating from one another among complication groups.

  • PDF

A Study on the Hydraulic Characteristics of Rashig Super-Ring Random Packing in a Counter-Current Packed Tower (역류식 충전탑에서 Raschig Super-ring Random Packing의 수력학적 특성에 대한 연구)

  • Kang, Sung Jin;Lim, Dong-Ha
    • Clean Technology
    • /
    • v.26 no.2
    • /
    • pp.102-108
    • /
    • 2020
  • In recent years, packed column has been widely used in separation processes, such as absorption, desorption, distillation, and extraction, in the petrochemical, fine chemistry, and environmental industries. Packed column is used as a contacting facility for gas-liquid and liquid-liquid systems filled with random packed materials in the column. Packed column has various advantages such as low pressure drop, economical efficiency, thermally sensitive liquids, easy repairing restoration, and noxious gas treatment. The performance of a packed column is highly dependent on the maintenance of good gas and liquid distribution throughout a packed bed; thus, this is an important consideration in a design of packed column. In this study, hydraulic pressure drop, hold-up as a function of liquid load, and mass transfer in the air, air/water, and air-NH3/water systems were studied to find the geometrical characteristic for raschig super-ring experiment dry pressure drop. Based on the results, design factors and operating conditions to handle noxious gases were obtained. The dry pressure drop of the random packing raschig super-ring was linearly increased as a function of gas capacity factor with various liquid loads in the Air/Water system. This result is lower than that of 35 mm Pall-ring, which is most commonly used in the industrial field. Also, it can be found that the hydraulic pressure drop of raschig super-ring is consistently increased by gas capacity factor with various liquid loads. When gas capacity factor with various liquid loads is increased from 1.855 to 2.323 kg-1/2 m-1/2 S-1, hydraulic pressure drop increases around 17%. Finally, the liquid hold-up related to packing volume, which is a parameter of specific liquid load depending on gas capacity factor, shows consistent increase by around 3.84 kg-1/2 m-1/2 S-1 of the gas capacity factor. However, liquid hold-up significantly increases above it.

Antimicrobial and Antioxidant Activity of Grapefruit and Seed Extract on Fishery Products (수산물에 대한 Grapefruit 종자추출물의 항균 및 항산화효과)

  • CHO Sung-Hwan;SEO Il-Won;CHOI Jong-Duck;JOO In-Saeng
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.23 no.4
    • /
    • pp.289-296
    • /
    • 1990
  • The antimicrobial and antioxidant activities of grapefruit seed extract(GFSE), which was extracted with glycerine in the special schematic extraction apparatus, were investigated for handling and processing of fishery products. The effectivity of GFSE has been tried on sardine, mackerel and shrimp divided into six lots for each fishery product: control(no treatment) and five GFSE-treated samples. Samples were inoculated with Salmenella typhi, incubated for 24hrs at $30^{\circ}C$ in dextrose-tryptone broth medium and prepared for microbiological 8f chemical analysis and organoleptic assessment. The bacteriological analytical results with GFSE(250ppm) showed the reduction of $1.8\times10^6\to2.0\times10^4,\;1.9\times10^6\to1.8\times10^4$ and $1.6\times10^6\to2.7\times10^3$ in total bacterial count for sardine, mackerel and shrimp, respectively. The test results with GFSE(500ppm) showed a $100\%$ reduction of bacterial mackerel treated with GFSE(500ppm) was reduced to $1.1\times10^4$ and $9.0\times10^3$ respectively. Antioxidant effect of treatment with GFSE at 500ppm level for three products was significant. LSD test results on organoleptic parameter for the samples treated with various showed a significant influence on the appearance, odor and texture in which at concentration 500ppm level give the excellent scours compared to each control.

  • PDF