• Title/Summary/Keyword: Parallel-series feed

Search Result 15, Processing Time 0.019 seconds

Bit Error Rate measurement of an RSFQ switch by using an automatic error counter (자동 Error counter를 이용한 RSFQ switch 소자의 Bit Error Rate 측정)

  • Kim Se Hoon;Kim Jin Young;Baek Seung Hun;Jung Ku Rak;Hahn Taek Sang;Kang Joon Hee
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.21-24
    • /
    • 2005
  • The problem of fluctuation-induced digital errors in a rapid single flux quantum (RSFQ) circuit has been very important issue. So in this experiment, we calculated error rate of RSFQ switch in superconductiyity ALU, The RSFQ switch should have a very low error rate in the optimal bias. We prepared two circuits Placed in parallel. One was a 10 Josephson transmission lines (JTLs) connected in series, and the other was the same circuit but with an RSFQ switch placed in the middle of the 10 JTLs. We used a splitter to feed the same input signal to the both circuits. The outputs of the two circuits were compared with an RSFQ XOR to measure the error rate of the RSFQ switch. By using a computerized bit error rate test setup, we measured the bit error rate of 2.18$\times$$10^{12}$ when the bias to the RSFQ switch was 0.398mh that was quite off from the optimum bias of 0.6mA.

Study of the Switching Errors in an RSFQ Switch by Using a Computerized Test Setup (자동측정장치를 사용한 RSFQ switch의 Switching error에 관한 연구)

  • Kim, Se-Hoon;Baek, Seung-Hun;Yang, Jung-Kuk;Kim, Jun-Ho;Kang, Joon-Hee
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.36-40
    • /
    • 2005
  • The problem of fluctuation-induced digital errors in a rapid single flux quantum (RSFQ) circuit has been a very important issue. In this work, we calculated the bit error rate of an RSFQ switch used in superconductive arithmetic logic unit (ALU). RSFQ switch should have a very low error rate in the optimal bias. Theoretical estimates of the RSFQ error rate are on the order of $10^{-50}$ per bit operation. In this experiment, we prepared two identical circuits placed in parallel. Each circuit was composed of 10 Josephson transmission lines (JTLs) connected in series with an RSFQ switch placed in the middle of the 10 JTLs. We used a splitter to feed the same input signal to both circuits. The outputs of the two circuits were compared with an RSFQ exclusive OR (XOR) to measure the bit error rate of the RSFQ switch. By using a computerized bit-error-rate test setup, we measured the bit error rate of $2.18{\times}10^{-12}$ when the bias to the RSFQ switch was 0.398 mA that was quite off from the optimum bias of 0.6 mA.

  • PDF

Wideband Array Antenna Design for Ku-Band Satellite Communications Using Mixed Patches (혼합 패치를 이용한 Ku 대역 위성통신용 광대역 배열 안테나 설계)

  • Seong-hun Kim;Ji-hwan Ko
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.3
    • /
    • pp.281-286
    • /
    • 2023
  • This paper proposes a design of a wideband array antenna involving the downlink bands of fixed satellite service (FSS) and broadcasting satellite service (BSS) by applying two mixed patch sets. The proposed antenna is implemented on FR4 substrate by arranging rectangular patches in 6 by 2. To design a wideband antenna (10.7~12.75 GHz) covering both FSS downlink bands (10.7~10.95 GHz, 11.2~11.45 GHz) and BSS downlink bands (11.7~12.5 GHz, 12.2~12.75 GHz, 11.7~12.2 GHz), rectangular patches working at 11.5 GHz and 12.5 GHz are arranged alternately, and thus the proposed antenna can obtain a wide bandwidth equivalent to 30.8% of the center frequency. The proposed antenna was fabricated and measured, and the results are well matched with the simulated ones. From the performances, the proposed antenna can be applied to the receiving antenna for FSS and BSS downlinks.

Design of Three-stacked Microstrip Patch Array Antenna Having Tx/Rx Feeds For Satellite Communication (위성통신을 위한 송수신 겸용 삼중 적층 마이크로스트립 패치 배열 안테나 설계)

  • Park, Ung-Hee;Noh, Haeng-Sook
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.11 no.5
    • /
    • pp.853-859
    • /
    • 2007
  • This paper presents a microstrip patch array antenna having transmission feed and reception feed for satellite communication in the Ku band. In this paper, the element of the patch array antenna is a three-stacked structure consisting of one radiation patch and two parasitic patches for high gain and wide bandwidth characteristics. To obtain higher gain, the unit elements are expanded into a $1{\times}8$ may using a mixture of series and parallel feeds. The proposed antenna has horizontal polarization for the Rx band and vertical polarization for the Tx band. To verify the practicality of this antenna, we fabricated a three-stacked patch array antenna and measured its performance. The gain of the array antenna in the Rx and Tx bands exceeds 17 and 18 dBi, respectively. The impedance bandwidth is over 10 % in both bands. The cross-polarization level is below -25 dB, and the sidelobe level is below -9.4 dB.

Multi-stage Process Study of PEI-PDMS Hollow Fiber Composite Membrane Modules for $H_2/CO_2$ Mixed Gas Separation ($H_2/CO_2$ 혼합기체의 분리를 위한 PEI-PDMS 중공사 복합막 모듈의 다단 공정 연구)

  • Lee, Chung Seop;Cho, Eun Hye;Ha, Seong Yong;Chung, Jong Tae;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 2013
  • Poly(ether imide) (PEI)-poly(dimethylsioxane) (PDMS) composite membranes and their modules were prepared, which are capable of selective $CO_2$ separation from the mixture gas. The gas flow rate, concentration, recovery ratio of $H_2$ and removal ratio of $CO_2$ outflowing by stage-cut were characterized at $25^{\circ}C$ and the constant pressure. In addition, to increase the recovery ratio of $H_2$, one stage, two stage series connection, and three stages series + parallel connection tests were carried out. When the stage-cut was 0.32 for the three stages connection operation, the concentration $H_2$ of the produced gas and the recovery ratio of $H_2$ was 97% and 85%, respectively. And also the removal ratio of $CO_2$ was 90% was obtained and the recycled gas concentration was similar with that of the feed gases.