• Title/Summary/Keyword: Parallel-flow

Search Result 1,066, Processing Time 0.037 seconds

Performance Characteristics of Water-Chilling Heat Pump Using CO2 on the Variation of Secondary Fluid Conditions (2차 유체 조건 변화에 대한 CO2용 수냉식 열펌프의 성능 특성에 관한 연구)

  • Son, Chang-Hyo;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.5
    • /
    • pp.543-551
    • /
    • 2007
  • The performance characteristics of water-chilling heat pump using $CO_2$ with respect to variation of inlet temperature and mass flow rate of secondary fluid was investigated experimentally. An experimental apparatus is consisted of a compressor, a gas cooler, an expansion valve, an evaporator and a liquid receiver. All heat exchangers used in the test rig are counter-flow-type heat exchangers with concentric dual tubes, which ate made of copper. The gas cooler and the evaporator consist of 6 and 4 straight sections respectively arranged in parallel, each has 2.4 m length. The experimental results were summarized as the followings : As inlet temperature of secondary fluid in the gas cooler increases from $10^{\circ}C$ to $40^{\circ}C$, the compressor work, heating capacity and heating COP were varied to 37.8%, -13%, -35.9%, respectively. The heating capacity, compressor work, heating COP were turned into 23.3%, 6.42%, 13.1%, respectively when ass flow rate of secondary fluid in the evaporator increases from 70 g/s to 150 g/s. The above tendency is similar with performance variation with respect to temperature variation of secondary fluid in the conventional vapor compression cycle.

EFFECTS OF SHOWERHEAD DIAMETERS ON THE FLOWFIELDS IN A RF-PECVD REACTOR (CVD 반응기 내에서의 유동장에 대한 샤워헤드 지름의 영향에 대한 수치적 연구)

  • Kim, You-Jae;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1475-1480
    • /
    • 2004
  • Plasma Enhanced Chemical Vapor Deposition (PECVD) process uses unique property of plasma to modify surfaces and to achieve the high deposition rates. In this study, a vertical thermal RF-PECVD (Radio Frequency-PECVD) reactor is modeled to investigate thermal flow and the deposition rates with various shapes of the showerhead. The showerhead in the CVD reactor has the shape of a ring and gases are injected in parallel with the susceptor, which is a rotating disk. In order to achieve the high deposition rates, we have simulated the thermal flow fields in the reactor with several showerhead models. Especially the effects of the number of injection holes and the rotating speed of the susceptor are studied. Using a commercial code, CFDACE, which uses FVM (Finite Volume Method) and SIMPLE algorithm, governing equations have been solved for the pressure, mass-flow rates and temperature distributions in the CVD reactor. With the help of the Nusselt number and Sherwood number, the heat and mass transfers on the susceptor are investigated. In order to characteristics of measure the flatness of the layer, furthermore, the relative growth rate (RGR) is considered.

  • PDF

Development of an Cross Flow Air-Cooled Plate Heat Exchanger (직교류 공랭식 판형열교환기의 성능평가)

  • Kim, Min-Sung;Lee, Jae-Hoon;Park, Seong-Ryong;Ra, Ho-Sang;Jeong, Jae-Hoon;Lim, Hyug
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.235-240
    • /
    • 2007
  • Performance of an air-cooled plate heat exchanger (PHE) was evaluated in this study. The PHE was manufactured in two types of single-wave and double-wave plates in parallel assembly. The heat exchanger aims to substitute open-loop cooling towers with closed-loop water circulation, which guarantees cleanliness and compactness. In this study, prototype single-wave and double-wave PHEs were designed and tested in a laboratory scale experiments. From the tests, the double-wave PHE shows approximately 50% enhanced heat transfer performance compared to the single-wave PHE. However, the double-wave PHE costs 30% additional pressure drop. For the commercialization, a wide channel design for air flow would be essential for performance and reliability.

  • PDF

Numerical Analysis of High-Reynolds-Number Flow around Axisymmetric Body (축대칭체 주위 고 레이놀즈수 유동에 대한 수치해석)

  • Choi, Jung-Kyu;Kim, Hyoung-Tae
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.6
    • /
    • pp.631-636
    • /
    • 2008
  • In this paper, numerical analysis based on the RANS equation and the Realizable ${\kappa}-{\varepsilon}$ turbulence model is carried out for flows around an axisymmetric body at three Reynolds numbers($1.22{\times}10^7$, $1.0{\times}10^8$, $1.5{\times}10^8$) and the numerical results are compared with experiments data. Computed velocity distributions agree well with experiments as the Reynolds number increases. Pressure distributions agree well with the results of the potential flow except the tail region but differ from experiments for the parallel middle body as well as tail region. Pressure gradients show a good agreement with those of potential flow and experiment except the tail region. Friction coefficients show that the numerical results generally are lower than the experimental results estimated from the measured velocity. The difference of friction coefficients between the calculation and the experiment increases with growing of a boundary layer.

Merged-Packet based Effective Queuing Mechanism for Underwater Networks (결합패킷 활용기반 수중네트워크 전송 큐 관리 기법)

  • Shin, Soo Young;Park, Soo-Hyun;Namgung, Jung Il
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.2
    • /
    • pp.61-67
    • /
    • 2017
  • In this paper, an adaptive MAC technique for various underwater environment with narrow-bandwidth and low transmission speed was proposed. In previously published Underwater Packet Flow Control (UPFC) technique, three transmission types (normal, block and parallel transmission) had been proposed using the number of transmission and transmission time. In addition to the UPFC, the proposed technique is an improved version of UPFC having more effective queuing technique for merge transmission. A mathematical model of the proposed queuing theory was constructed and its increased efficiency per unit transmission number was also verified based on simulations.

A Study on the Performance of Centrifugal Blowers by Blades Characteristics (원심형 송풍기의 날개 특성에 따른 성능에 관한 연구)

  • Kim, J.W.;Ahn, E.Y.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.5 s.26
    • /
    • pp.13-19
    • /
    • 2004
  • Centrifugal blowers are widely used for air handling units in industry applications. The blower has a centrifugal impeller and a scroll casing including a driving component such as an electric motor. The impeller takes forward or backward blades to induce flows into the blower, Comprehensive investigation according to the two kinds of blades is systematically carried out for a guidance of design for this kind research. It is observed that flow rate of the blower with forward blades is larger than that of the system with backward blades. Otherwise, the system noise is more pronounced in the case of the blower with forward blades. The reason is due to larger velocity from the rotating forward blades that pose obtuse angle with the circumferential direction. The distinguished characteristics are validated by a parallel experiments with a wind tunnel and in an anechoic chamber. Numerical analysis for the system shows detail information inside the blades and the casing. A series of figures to show the flow details offer deep understanding of the performance of a centrifugal blower with different blades.

Analysis of Pulsating Flow in Elastic Parallel Plates and an Elastic Pipe Model Using Moving Boundary Algorithm (이동경계 수치해법을 이용한 탄성평판 및 탄성관 모델내의 맥동유동 해석)

  • Park Hyung Gyu;Kim Charn-Jung;Lee Chong-Sun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.4 s.235
    • /
    • pp.425-434
    • /
    • 2005
  • In order to analyze pulsating flows in elastic blood vessels, a method based on the ALE concept and finite volume method was reformed and modulated to include wall motion of elastic vessels and impedance phase angle(phase difference between wall motion and blood flow). Our study indicated wall shear rates(WSR) were significantly influenced by the wall motion and the impedance phase angle. For larger wall motion more than $5{\%},$ the computed WSR started to deviate from the results of the perturbation theory that assumed smaller wall motion. The study showed that oscillatory shear index increased as the impedance phase angle became more negative like $-70{\circ}\;or\;-80{\circ}$ due to reduced mean WSR and increased amplitude of WSR. This result indicated that hypertensive patients are more vulnerable to atherosclerosis than normal persons because of the role of more negative impedance phase angles usually observed in these patients.

Large Eddy Simulation of Turbulent Flows over Backward-facing Steps (후향 계단에서 난류 유동에 대한 대와동모사)

  • Hwang, Cheol-Hong;Kum, Sung-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.3
    • /
    • pp.507-514
    • /
    • 2009
  • Large eddy simulation code was developed to predict the turbulent flows over backward-facing steps including a recirculating flow phenomena. Localized dynamic ksgs-equation model was employed as a LES subgrid model and the LES solver was implemented on parallel computer consisting of 16 processors to reduce computational costs. The results of laminar flow showed qualitative and quantitative agreements between current simulations and experimental results availablein literatures. The simulation of the turbulent flows also yielded reasonable results. From these results, it can be expected that developed LES code will be very useful to analyze the combustion in stabilities and noise of a practical combustor in the future.

Effect on the Wake Flow according to Various length of Rectangular Cylinder in a Parallel Arrangement (병렬구조를 가진 장방형 실린더의 길이가 후류 유동에 미치는 영향)

  • Choe, Sang-Bom;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.6
    • /
    • pp.760-767
    • /
    • 2014
  • An experimental study is carried out to investigate the effect of jet stream in the gab of rectangular cylinders with different length in a parallel arrangement by using PIV method in a circulating water channel. The height(h) of the rectangular cylinder and the gap between the cylinder is 10mm, and the width(B) which is 300mm. The length of the model for flow direction was applied to 30mm, 60mm, 90mm & 120mm, The aspect ratio of a model on the basis of height(H=30mm) is 1, 2, 3 and 4. Reynolds number $Re=1.4{\times}10^4$, $Re=2.0{\times}10^4$, $Re=2.9{\times}10^4$ based on the height(H) of model for the distance of tidal distributions as of water depth have been applied during the whole experiments. The measurement area was set to 5H rear of the cylinder. As a result, Vortex size in the wake area were increased as velocity increased. and high aspect ratio increased through-flow velocity component in the near wake. Velocity deficit increased highly after near-wake area and low aspect ratio.

Analysis of the Contactless Power Transfer System Using Modeling and Analysis of the Contactless Transformer

  • Ryu Myung-Hyo;Kim Jong-Hyun;Baek Ju-Won;Cha Hon-Nyong
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.351-358
    • /
    • 2006
  • In this paper, the electrical characteristics of the contactless transformer is presented using the conventional coupled inductor theory. Compared with the conventional transformer, the contactless transformer has a large airgap, long primary wire and multi-secondary wire. As such, the contactless transformer has a large leakage inductance, small magnetizing inductance and poor coupling coefficient. Therefore, large magnetizing currents flow through the entire primary system due to small magnetizing inductance, resulting in low overall system efficiency. In high power applications, the contactless transformer is so bulky and heavy that it needs to be split by some light and small transformers. So, the contactless transformer needs several small transformer modules that are connected in series or parallel to transfer the primary power to the secondary one. This paper shows the analysis and measurement results of each contactless transformer module and comparison results between the series- and parallel-connection of the contactless transformer. The results are verified on the simulation based on the theoretical analysis and the 30kW experimental prototype.