• 제목/요약/키워드: Parallel transformer

검색결과 224건 처리시간 0.037초

신재생에너지용 연계형 인버터의 고효율 승압에 관한 연구 (Study on High Efficiency Boosting-up Circuit for Renewable Energy Application)

  • 정태욱;김주용;최세권;조준석;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.336-339
    • /
    • 2009
  • In this paper, such as battery power or solar energy and fuel cells generated from Renewable energy sources, high voltage to low voltage DC-DC Converter for converting the design of the study. System consists of low voltage ($24{\sim}28$ [VDC]) and Boosts the voltage (270 [VDC]) for a 3 [kW] DC-DC converter and control circuit is configured as, Power switch the ST Tomson's Automotive low voltage high current MOSFET switches STE250NS10S (temperature 250A) was applied to the two parallel. Also, Controller's processor used ATMEGA128, and Gate Drive applies and composed Photo Coupler TLP250. development. Input voltage (24V) and output voltage (270V) for Conversion in the H-bridge converter topology of the circuit output side power and voltage to control the implementation of the Phase shift angle control applied. And, 3kW of power to pass appropriate specification of the secondary side as interpreted by the high frequency transformer, and the experimental production and analysis of the experiment

  • PDF

Efficiency Optimization with a Novel Magnetic-Circuit Model for Inductive Power Transfer in EVs

  • Tang, Yunyu;Zhu, Fan;Ma, Hao
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.309-322
    • /
    • 2018
  • The technology of inductive power transfer has been proved to be a promising solution in many applications especially in electric vehicle (EV) charging systems, due to its features of safety and convenience. However, loosely coupled transformers lead to the system efficiency not coming up to the expectation at the present time. Therefore, at first, the magnetic core losses are calculated with a novel magnetic-circuit model instead of the commonly used finite-element-method (FEM) simulations. The parameters in the model can be obtained with a one-time FEM simulation, which makes the calculation process expeditious. When compared with traditional methods, the model proposed in the paper is much less time-consuming and relatively accurate. These merits have been verified by experimental results. Furthermore, with the proposed loss calculation model, the system is optimized by parameter sweeping, such as the operating frequency and winding turns. Specifically, rather than a predesigned switching frequency, a more efficiency-optimized frequency for the series-parallel (SP) compensation topology is detected and a detailed investigation has been presented accordingly. The optimized system is capable of an efficiency that is greater than 93% at a coil separation distance of 200mm and coil dimensions of $600mm{\times}400mm$.

차량용 유도전력 집전 장치의 특성해석 (The Modeling of inductive power collector for vehicle)

  • 한경희;이병송;김도원;백수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1610-1612
    • /
    • 2005
  • In this paper, the inductive power collector using electromagnetic induction for vehicle such as the PRT(Personal Rapid Transit) system is suggested and some ideas for power collector design to improve the power transfer performance are presented. The proposed the inductive power collector is used for the PRT system, which has a large air-gap and demands a large electrical power capability. But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. Also, a model of power collector and parallel winding structure and a model of concentration/decentralization winding are presented, in addition, the performance of inductive power collector to alignment condition between the primary power line and the inductive power transformer was verified by computer simulation of 2kW model.

  • PDF

철도 급전시스템에서의 고조파 해석 및 대책 연구 (A Study on the Countermeasures to Suppress Harmonics in the Traction Power Supply System)

  • 오광해;이장무;창상훈;한문섭;김길상
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1999년도 추계학술대회 논문집
    • /
    • pp.318-325
    • /
    • 1999
  • Modern AC electric car has PWM(Pulse Width Modulation)-controlled converters, which give rise to higher harmonics. The current harmonics injected from AC electric car is propagated through power feeding circuit, As the feeding circuit is a distributed constant circuit composed of RLC, the capacitance of the feeding circuit and the inductance on the side of power system cause a parallel resonance and a magnification of current harmonics at a specific frequency. The magnified current harmonics usually brings about various problems. That is, the current harmonics makes interference in the adjacent lines of communications and the railway signalling system. Furthermore, in case it flows on the side of power system, not only overheating and vibration at the power capacitors but also wrong operation at the protective devices can occur. Therefore, the exact assessment of the harmonic current flow must be undertaken at design and planning stage for the electric traction systems. From these point of view, this study presents an approach to model and to analyse traction power feeding system focused on the amplification of harmonic current The proposed algorithm is applied to a standard AT(Auto-transformer)-fed test system in which electric car with PWM-controlled converters is running.

  • PDF

Analysis and Implementation of LC Series Resonant Converter with Secondary Side Clamp Diodes under DCM Operation for High Step-Up Applications

  • Jia, Pengyu;Yuan, Yiqin
    • Journal of Power Electronics
    • /
    • 제19권2호
    • /
    • pp.363-379
    • /
    • 2019
  • Resonant converters have attracted a lot of attention because of their high efficiency due to the soft-switching performance. An isolated high step-up converter with secondary-side resonant loops is proposed and analyzed in this paper. By placing the resonant loops on the secondary side, the current stress for the resonant capacitors is greatly reduced. The power loss caused by the equivalent series resistance of the resonant capacitor is also decreased. Clamp diodes in parallel with the resonant capacitors ensure a unique discontinuous current mode in the converter. Under this mode, the active switches can realize soft-switching during both turn-on and turn-off transitions. Meanwhile, the reverse-recovery problems of diodes are also alleviated by the leakage inductor. The converter is essentially a step-up converter. Therefore, it is helpful for decreasing the transformer turn-ratio when it is applied as a high step-up converter. The steady-state operation principle is analyzed in detail and design considerations are presented in this paper. Theoretical conclusions are verified by experimental results obtained from a 500W prototype with a 35V-42V input and a 400V output.

30kW 고주파 용접 전원용 Full-Bridge 컨버터의 분산설계에 관한 연구 (Research for Distributed Design for 30kW Full-Bridge Converter for in High Frequency Welding Machine)

  • 김민우;최승원;이일운;이준영;정계수;이토 에이지
    • 전력전자학회논문지
    • /
    • 제25권6호
    • /
    • pp.469-476
    • /
    • 2020
  • This study presents the results of the research on power supplies for welding machine using MOSFET switches in high frequency switching for ease of design and use a 100 kHz switching frequency for high power density. The topology of the proposed power supplies for welding machine is ZVS-PWM full-bridge converter. The proposed converter is designed on a distributed transformer for ease of design and be used in a 100 kHz switching frequency for high power density. The problem of power imbalance of transformers occurring in parallel operation of transformers can be improved by applying common mode coupled inductor and the corresponding contents are experimented and verified in this paper to present conclusions.

다중 어댑터를 이용한 교차 언어 및 스타일 기반의 제목 생성 (Cross-Lingual Style-Based Title Generation Using Multiple Adapters)

  • 박요한;최용석;이공주
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제12권8호
    • /
    • pp.341-354
    • /
    • 2023
  • 문서의 제목은 문서의 내용을 가장 효율적으로 요약하여 제공해 준다. 이때 독자들이 선호하는 스타일과 언어에 따라 문서의 제목을 다르게 제공해 준다면, 독자들은 문서의 내용을 좀 더 쉽게 예측할 수 있다. 본 연구에서는 문서가 주어졌을 때 언어와 스타일에 따라 제목을 자동 생성하는'교차 언어 및 스타일 기반의 제목 생성 모델을 제안한다. 모델을 학습하기 위해서는 같은 내용을 다른 언어와 다른 스타일로 작성한 병렬데이터가 필요하다. 그러나 이러한 종류의 병렬데이터는 구축하기 매우 어렵다. 반면, 단일 언어와 단일 스타일로 구축된 제목 생성 데이터는 많으므로 본 연구에서는 제로샷(zero-shot) 학습으로 제목 생성을 수행하고자 한다. 교차 언어 및 스타일 기반의 제목 생성을 학습하기 위해 다중 언어로 사전 학습된 트랜스포머 모델에 각 언어, 스타일, 기계번역을 위한 어댑터를 추가하였다. 기계 번역용 병렬데이터를 이용하여 기계번역을 먼저 학습한 후, 동일 스타일의 제목 생성을 학습하였다. 이때, 필요한 어댑터만을 학습하고 다른 부분의 파라미터는 모두 고정시킨다. 교차 언어 및 스타일 기반의 제목을 생성할 때에는 목적 언어와 목적 스타일에 해당하는 어댑터만을 활성화시킨다. 실험 결과로는 각 모델을 따로 학습시켜 파이프라인으로 연결시킨 베이스라인에 비해 본 연구에서 제안한 제로샷 제목 생성의 성능이 크게 떨어지지 않았다. 최근 대규모 언어 모델의 등장으로 인한 자연어 생성에서의 많은 변화가 있다. 그러나 제한된 자원과 제한된 데이터만을 이용하여 자연어 생성의 성능을 개선하는 연구는 계속되어야 하며, 그런 점에서 본 연구의 의의를 모색한다.

LCD 백라이트용 외부전극 형광램프의 인버터 회로 해석 (Analysis of Inverter Circuit with External Electrode Fluorescent Lamps for LCD Backlight)

  • 정종문;신명주;이미란;김가을;김정현;김상진;이민규;강미조;신상초;안상현;길도현;유동근;구제환
    • 한국진공학회지
    • /
    • 제15권6호
    • /
    • pp.587-593
    • /
    • 2006
  • 외부전극 형광램프를 광원으로 하는 백라이트의 저항$(R_L)$과 전기용량(C), 그리고 인버터의 트랜스포머 인덕턴스(L)로 구성된 회로를 분석하였다. 램프의 저항과 전기용량은 램프에 흐르는 전류와 전압의 위상차 및 Q-V 그래프에서 결정된다. 32인치용 EEFL 램프 하나의 저항 값은 $66\;k\Omega$이고 전기용량은 21.61 pF이다. 20 개의 EEFL을 병렬 연결한 백라이트의 저항은 $3.3\;k\Omega$이고 전기용량은 402.1 pF이다. 램프 및 트랜스포머 회로에서 임피던스 매칭 주파수는 2 차 코일의 인덕턴스 $L_2$와 결합계수 k로 나타내며, $\omega_M=1/\sqrt{L_2C(1-k^2)}$ 이다. 램프 시스템의 전류와 전압은 임피던스 매칭 주파수에서 최대값을 갖는다. 이러한 해석 해의 결과는 실험 결과와 잘 일치한다.

실시간 전력계통 시뮬레이터를 이용한 보호계전모델 개발 (Implementation and Verification of Distance Relay Models for Real Time Digital Simulator)

  • 이주훈;윤용범;차승태;이진;최종웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권7호
    • /
    • pp.393-400
    • /
    • 2003
  • This paper discusses how to implement and verify a software model of the digital relay that can be added to real time digital simulator(RTDS) model library and is then subjected to the same outputs as the actual relay. The software model is stand-alone and can be used with real relays. It is also possible to conduct interactive real-time tests when the system effects of the relay action need to be investigated. The characteristics of mho type and the quadrilateral type, which is commonly used in recently developed relays, are modeled in this paper. Single circuit line and double circuit line system are used for model verification. The transmission lines are each 100 km in length and are modeled as distributed parameter lines but not frequency dependent. The transmission lines in the single circuit system are modeled as ideally transposed line. The mutual coupling data with the parallel line was taken account in the transmission lines for the double circuit system. The main CTs and PTs are included and operated in their linear region during the tests. For the purpose of testing the relay model accuracy the faults have been applied at various points on the protected line. Its accuracy is assessed against theoretical values.

스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발 (Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator)

  • 이종훤
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.